0% found this document useful (0 votes)
4 views

D MegatronMT

The MegaTron MT touch screen controller is designed for controlling various parameters such as conductivity, pH, ORP, and chemical feeds in industrial applications. It features a customizable LCD display, internet communications, and multiple system capabilities, making it user-friendly and flexible. The unit supports various options for configuration and includes advanced relay logic for tailored system needs.

Uploaded by

nitantharani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views

D MegatronMT

The MegaTron MT touch screen controller is designed for controlling various parameters such as conductivity, pH, ORP, and chemical feeds in industrial applications. It features a customizable LCD display, internet communications, and multiple system capabilities, making it user-friendly and flexible. The unit supports various options for configuration and includes advanced relay logic for tailored system needs.

Uploaded by

nitantharani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Touch

Data Sheet

Touch Screen
Controller
Microprocessor
Control of:
 Conductivity
 pH
 ORP
 Chemical Feed
 Biocide Feed
Service Reports
4-20mA In & Outs

Key Features Application


• Customizable LCD Display MegaTron MT touch screen controller is the
• On Board History Graphs industry leader in user friendly capability and
• Multiple System Capability flexibility with a large color touch screen.
• Simple Touch Screen Menu Units can be configured to control a wide range
• Internet Communications Included of digital and analog inputs. Advanced relay
• Up to 20 Assignable Relays logic and customization lets you configure a
• Customizable Notepad unit to meet your specific system needs.
• Multi-Level Security Code
MT touch units can control single or
• Wi-Fi Capable
multiple tower, boiler, waste water and other
• Non-Volatile Memory
industrial applications and provide web
• E-mail Alarm Capable based communications and reporting with
• MODbus and BACnet Options WebAdvantage.
Build a Model Specifications
Units can be configured to control 1-4 systems. The Electrical
model number starts with MT followed by the code for • Input: 95-240 VAC, 50/60 Hz
each function needed for the first system (MTCPF3E). • Control: Equal to input voltage (95-240VAC)
If building a multi-system unit, put a - after the functions fused at 2.5A per relay
of a system and list the functions for the next system Prewired units are supplied with an 8’ (248.84 cm)
(MTCPF3E-B2F2). If systems are the same, just put a power cord and 8” (20.32 cm) output receptacles.
-X2,3 or 4 after a system (MTCPF3E-X2). After main
control functions have been selected, insert a - and list Operational
the desired common options (MTCPF3-CF3E-N4). • Display: 6.875” Diagonal LCD Touch Screen
Conductivity Control (1 per system max) • Conductivity Control: uS/cm, mS/Cm, PPM scales
B2 = BE-32 Standard Boiler probe with ranges up to 50,000 depending on sensor
C = TE-4A Standard Tower probe selection.
Make-up or Misc Conductivity (1 per system) Boiler sampling: continuous, timed or sample and hold.
M = DI-4A Standard make-up probe • pH: 0-14 scale
M9 = Floor drain conductivity alarm sensor • ORP: +/- 1000 millivolts scale
• Accuracy: +/- 1%
PH Control (1 per system)
P = TPE-21 Standard Tower probe • Feed Timers are all selectable from:
Pulse - Water meter activated w/accumulator.
ORP Control (1 per system) Percent - 1 - 100% of a cycle time.
R = TOE-21 Standard ORP probe Limit - Limits feed with bleed.
Temp (2 max/system – Each conductivity uses one) Post - 1-100% of post bleed or other time with limit.
T = TC-1 Standard temp probe 28 Day - Biocide timer.
Feed Timers (max of 5 per system) Recycle - Recycle timer.
F1 to F5 (F4 = Four feed timers)
Enclosure
Flow Switch
Heavy duty NEMA 4X style high impact
E = Flow Switch
thermoplastic with padlockable gasketed
OPTIONS Lexan cover.
A - Conduit connection
A3 - Liquid tights only with CE mark, 240 volt Environment
H15 - Dual networks w/ WebAdv via TCP/IP or Wifi
Ambient temperature: 0o to 125oF (-17 to 52oC)
& Modbus via TCP/IP
H25 - Dual networks w/ WebAdv via TCP/IP or Wifi Relative humidity: 0 to 100%
& BACnet via TCP/IP
H26 - Dual networks w/ WebAdv via TCP/IP or Wifi Electrodes
& BACnet read/write via TCP/IP Tower Standard electrodes are supplied in 3/4” (1.91 cm)
N - 4-20mA Inputs (N4, N8, N12, N16) SCH 80 PVC female slip tees with quick release nut.
O - 4-20MA Outputs (O4, O8) • Conductivity: TE-4A 150 psi (10.3 bar) / 140oF (60oC) Max
V4 - Additional 24 VDC power supply • pH: TPE-2 100 psi (6.8 bar) / 140oF (60oC) Max
W - 10 Auxiliary flow meter inputs • ORP: TOE-2 100 psi (6.8 bar) / 140oF (60oC) Max
Y - ETL Agency Listing • Temperature: TC-1 150 psi (10.3 bar) / 140oF (60oC) Max
Boiler Conductivity electrodes are supplied with 1”
NOTES:
1. Timers selectable (pulse, %, post bleed, limit, recycle (2.54 cm) MNPT SS threads.
or 28-day). Each system has 2 water meter inputs. • Conductivity: BE-32 250 psi @ 400°F / 350 psig @ 265°F
2. All expansion slots provided. PEEK core
3. Each system card comes with 5 digital inputs. Shipping Weight: Approximately 10 lbs. (4.536 kg)
4. Boiler conductivity should only be used on continuous
or surface lines; not bottom blowdown lines. Dimensions:
5. Contact the factory for a complete option list. W 13.5” (34.29 cm) x H 14.5” (36.83 cm) x D 7.125” (18.09 cm)

Get the Advantage


4700 Harold-Abitz Dr
Muskogee, OK 74403
800-743-7431 Phone
12/2023 888-686-6212 Fax
www.advantagecontrols.com