Manual and Semi-automatic Analysers: Gum - Rubber

Evaporation Bath
Linetronic Technologies SA

CH-6864 Arzo,Mendrisio, Switzerland


tel. +41 91 6300703, fax +41 91 6300719
www.lin-tech.ch – [email protected]
Via Onorio Longhi 2

LT/EB-241000/M

LT/EB-241400/M

ASTM D381 LT/EB-241000/M LT/EB-241400/M


DIN 51784 Gum Content in Fuels by Jet Evaporation Gum Content in Fuels by Jet Evaporation
IP 131 Air and Steam Air and Steam
IP 540 • Compact structure painted with anti-acid • Compact structure painted with anti-acid
ISO 6246 epoxidy products. epoxidy products.
• Rectangular aluminium metal block bath deeply • Circular aluminium metal block bath deeply
Gum Content in Fuels by Jet Evaporation. coated equipped with 8 × removable adapters. coated equipped with 4 × removable adapters.
This test method covers the determination • 2 × dedicated inlet lines: • 2 × dedicated inlet lines:
of the existent gum content of aviation fuels, . A ir inlet with in-line flowmeter for monitor . A ir inlet with in-line flowmeter for monitor
and the gum content of motor gasolines the instant air-flow and regulation ball valve; the instant air-flow and regulation ball valve;
or other volatile distillates in their finished form . S team inlet with distribution manifold . S team inlet with distribution manifold
(including those containing alcohol and ether and ball valve for regulating the flow; and ball valve for regulating the flow;
type oxygenates and deposit control additives) . S uper heater for steam heating. . S uper heater for steam heating.
at the time of test. • 8 × jets (one for each test place) fitted • 4 × jets (one for each test place) fitted
with its conical adapters with 500 with its conical adapters with 500
to 600-micron screens. to 600-micron screens.
• Temperature controlled by a digital • Temperature controlled by a digital
thermoregulator PID with overtemperature thermoregulator PID with overtemperature
alarm and probe PT100 A class with 0.1°C alarm and probe PT100 A class with 0.1°C
resolution and 0.5°C precision. resolution and 0.5°C precision.
• Safety manual thermostat for overheating • Safety manual thermostat for overheating
preventing with warning lamp. preventing with warning lamp.

Dimensions Dimensions
• 40 × 43 × 56 cm • 40 × 43 × 56 cm

Temperature Range Temperature Range


• Ambient to +246°C • Ambient to +246°C

Consumption Consumption
• 2200 Watt • 1800 Watt
• + 400 Watt superheater if optionally added • + 400 Watt superheater if optionally added

Power Supply Power Supply


• 220 Vac or 115 Vac 50/60Hz • 220 Vac or 115 Vac 50/60Hz


Manual and Semi-automatic Analysers: Gum - Rubber

Evaporation Bath

Linetronic Technologies SA

CH-6864 Arzo,Mendrisio, Switzerland


tel. +41 91 6300703, fax +41 91 6300719
www.lin-tech.ch – [email protected]
Via Onorio Longhi 2
LT/FA-247000/M

LT/EB-241500/M 5210

LT/EB-241500/M Factory options Steam Accessories


Gum Content in Fuels by Jet Evaporation for LT/EB-241400/M and LT/EB-241500/M • LAB-102-423/SG: steam generator
Air and Steam • D381-SH: Super-heater option · Steam supply: 19.5 Kg. / h
• Compact structure painted with anti-acid · Heating Power installed: 15-18 Kw
epoxidy products. Air Accessories · Steam temperature @ 3.5 bar: 152°C
• Circular aluminium metal block bath deeply • LT/FA-247000/M: flow apparatus · Power supply: 400V – 3ph - 50Hz
coated equipped with 5 × removable adapters. (for LT/EB-241400/M and LT/EB-241500/M) · Working Pressure: 5 bar / Max. working pressure:
• 2 × dedicated inlet lines: · Full die-cast aluminium construction 5,5 bar
. A ir inlet with in-line flowmeter for monitor ·N  o contact between rotating · Water: must be connected to a water line
the instant air-flow and regulation ball valve; and static components (boiler capacity 10 liters)
. S team inlet with distribution manifold · Motor power 2.20 kW • LAB-102-423: steam generator
and ball valve for regulating the flow; · Power supply 230 V 50/60 Hz or 115 Vac · Steam supply: 5.2 Kg. / h
. S uper heater for steam heating. · Designed flow rate 150 m³/h - 0 mbar · Power: 4KW
• 5 × jets (one for each test place) fitted · Noise level 66 dB(A) · Power supply: 230V – 1ph - 50Hz
with its conical adapters with 500 · Weight 27 Kg · Pressure: 4.5 bar
to 600-micron screens. • 5210: air filter for flow apparatus · Water: rear water tank of 20 liters
• Temperature controlled by a digital · K it composed by filter support with screwing
thermoregulator PID with overtemperature cover made in painted steel, filter element General Accessories
alarm and probe PT100 A class with 0.1°C with particle retain and adapter for connection • LAB-102-421: Pyrex® beaker
resolution and 0.5°C precision. to flow apparatus. • T-AS3C: thermometer ASTM 3C IP 73C
• Safety manual thermostat for overheating • 7084: filter element (spare). • 5550: tongs made in stainless steel with corks
preventing with warning lamp. • 3189: mass flow meter. protection, total length 250 mm
· Flow mass range from 1.2 to 60 nl/min.
Dimensions · Digital display readout. Spare Parts
• 40 × 43 × 56 cm · Connection joints ¼”. Only for LT/EB-241000/M
·P  ower supply, battery or micro-usb power • 3574: digital thermoregulator
Temperature Range supply. • 3114: heating cartridge 100 mm, pack of 2 pcs.
• Ambient to +246°C · Operating pressure 0.2 – 11 bar. • 7082: air jet complete, pack of 4 pcs.
· Made in anodized aluminium, Fkm seals. • 5476: spare metallic mesh, pack of 10 pcs.
Consumption · Repeatability ± 0.5% of full scale.
• 1800 Watt
• + 400 Watt superheater if optionally added

Power Supply
• 220 Vac or 115 Vac 50/60Hz