ACS880 Multidrives Catalog 3AUA0000115037 RevI EN
ACS880 Multidrives Catalog 3AUA0000115037 RevI EN
LOW VO LTAG E AC D R I V E S
—
Reliability, performance and safety.
ACS880 series.
3
—
Table of contents
10 Extended connectivity
11 Reliability
19 Technical data
20 – 23 ACS880 multidrives
30 – 31 Dimensions
38 – 39 Safety options
44 – 45 Sine filters
46 – 50 Brake options
51 – 52 Du/dt filters
—
The all-compatible ACS880 series
Reliability and flexibility
—
High quality
Automotive
Typical all protective functions.
—
Simplify your world
without limiting your possibilities
Built-to-order to meet customers’ needs, the ACS880 multidrives can meet
technical challenges through a wide selection of options that are all
mountable within the cabinet.
All-compatible user-interface
• All-compatible drives share the same easy-to-use
user interface.
See page 08
—
Up to IP54
Extended connectivity
• Communication with all major automation
networks
• Remote monitoring
• Integration tools for PLCs from ABB and
various other manufacturers
See page 10
—
9-year maintenance interval
Reliability
• Robust, long lifetime design for maximum reliability
• Removable memory unit
• Each drive factory tested at full load
• Nine-year service interval
See page 11
S I M P L I F Y YO U R W O R L D W I T H O U T L I M I T I N G YO U R P O S S I B I L I T I E S 7
—
ACS880 drives are designed for
maximum reliability
8 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
All-compatible user interface
—
Built to order for simplified installation
Choke
Safety functions
Extensive I/O
10 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Extended connectivity
Remote monitoring
With a built-in web server and standalone data
logger, the NETA-21 remote monitoring tool
enables secure worldwide access to your drives.
—
Better connectivity and
user experience
A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G 11
—
Reliability
—
Cost and time savings with
drive-based functional safety
Safety functions —
ACS880 drives have a safe torque off (STO)
function as a standard. Extended safety
Integrated safety simplifies
functions are provided by optional safety configuration
modules, which are easy to integrate inside the
drive. Integration with automation systems is
Easy configuration
quick and reliable using PROFIsafe connectivity.
Configuring the safety functions module is
Most safety functions achieve the SIL 3/PL e
easy thanks to the graphical user interface of
safety level.
the Drive composer pro PC tool.
—
Compatible with all kinds of
processes
Regeneration of energy
The ACS880 offers a number of solutions for
applications where electrical braking is needed.
As standard, ACS880 drives have a flux braking
feature that provides greater deceleration by
increasing the motor flux. If this is not sufficient,
optional brake unit can be used together with a
brake resistor.
—
Application- and industry-specific
solutions and programmability
Winches, +N5100
• Mooring
• Anchor control
• Accurate open loop speed & torque control
• Winch interface for multiple control stands
Winders, +N5000
• Roll diameter calculation
• Tension control
• Dancer and load cell control
• Inertia and friction compensation
Adaptive
programming
is an easy to use
dynamic programming
which allows flexible
adjustments to the Chemical industry
ACS880 software. • Direct torque control with sine filters
• Nine-year service interval
• Functionality that conforms with NAMUR requirements
IEC programming
based on IEC 61131
standard for full scale
PLC programmability
is available as
an option. Explosive atmospheres
• Type approval with ABB Ex motors
• ATEX-approved safe torque off, STO (+Q971) and thermistor
protection module (+L537)
Marine
• Type approval from various key classification bodies (+C132)
• Product certification process
• 440 V variant
16 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Standard interface and extensions
for plug-in connectivity
—
— ACS880 multidrives offer a wide range 01
01 Control unit ZCU
— of standard interfaces. In addition, the drive
02 Example of a control unit (ZCU/BCU) has three option slots
typical multidrives
input/output that can be used for extensions, including
connection diagram. fieldbus adapter modules, input/output
Variations maybe
possible. For further extension modules, feedback modules, and
information, please a safety functions module. For I/O extensions,
see the ACS880
user manual. see page 34.
—
02
Ready NO 13
250 V AC/30 V DC COM 12
2A NC 11
Running NO 23
250 V AC/30 V DC COM 22
2A NC 21
Faulted (-1) NO 33
250 V AC/30 V DC COM 32
2A Fault
NC 31
External power input XPOW
GND 2
24 V DC, 2 A
+24VI 1
Reference voltage and analog inputs J1, J2, XAI
AI1:U AI2:U
AI1/AI2 current/voltage selection
AI1:I AI2:I
By default not in use. AI2- 7
0(4) to 20 mA, R in = 100 ohm AI2+ 6
Speed reference AI1- 5
0(2) to 10 V, R in > 200 kohm AI1+ 4
Ground AGND 3
-10 V DC, R L 1 to 10 kohm -VREF 2
10 V DC, R L 1 to 10 kohm +VREF 1
Analog outputs XAO
Motor current 0 to 20 mA, AGND 4
R L < 500 ohm AO2 3
Motor speed rpm 0 to 20 mA, AGND 2
R L < 500 ohm AO1 1
Drive-to-drive link J3, XD2D
Drive-to-drive link termination ON OFF
Shield 4
Drive-to-drive link or built-in Modbus BGND 3
A 2
B 1
Safe torque off XSTO
IN2 4
IN1 3
Safe torque off. Both circuits must be closed for the drive to start.
SGND 2
OUT 1
Digital inputs XDI
By default not in use DI6 6
Constant speed 1 select (1 = on) DI5 5
Acceleration and deceleration select DI4 4
Reset DI3 3
Forward (0)/Reverse (1) DI2 2
Stop (0)/Start (1) DI1 1
Digital input/outputs XDIO
Output: Running DIO2 2
Output: Ready DIO1 1
Ground selection
Auxiliary voltage output, digital input interlock XD24
Digital input/output ground DIOGND 5
+24 V DC 200 mA +24VD 4
Digital input ground DICOM 3
+24 V DC 200 mA +24VD 2
Digital interlock DIIL 1
Safety functions module connection X12
Control panel/PC connection X13
Memory unit connection X205
18 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
How to select a drive
The right drive is extremely easy to select. The following instructions
show you how to order the right drive for your application.
1 —
select the related rating table. Or use ABB’s
Ratings, types and voltages
DriveSize dimensioning tool. Inverter units, UN = 400 V
UN = 400 V (range 380 to 415 V). The power ratings are valid at nominal voltage 400 V (1.5 to 2800 kW).
Drive type Frame Nominal ratings Light overload use Heavy-duty use Noise Heat Air
size level dissipation flow
IN I MAX PN I Ld PLd I Hd PHd
AC AC
(A) (A) (kW) (A) (kW) (A) (kW) (dB(A)) (kW) (m3/h)
Inverter units (INU), ACS880-107
2
ACS880-107-0014A-3 R2i 14 16.5 5.5 13 5.5 11 4 39 0.14 48
ACS880-107-0018A-3 R2i 18 21 7.5 16.8 7.5 14 5.5 39 0.17 48
ACS880-107-0025A-3 R3i 25 33 11 23 11 19 7.5 63 0.2 142
current ratings.
ACS880-107-0078A-3 R4i 78 100 37 74 37 69 30 70 0.6 290
ACS880-107-0094A-3 R4i 94 124 45 90 45 75 37 70 0.74 290
ACS880-107-0100A-3 R4i 104 125 55 100 55 78 37 70 0.75 290
ACS880-107-0140A-3 R6i 141 183 75 135 75 105 55 71 1.1 650
ACS880-107-0170A-3 R6i 169 220 90 162 90 126 55 71 1.4 650
ACS880-107-0210A-3 R6i 206 268 110 198 110 154 75 71 1.8 650
ACS880-107-0250A-3 R6i 246 320 132 236 132 184 90 71 2 650
ACS880-107-0300A-3 R7i 300 390 160 288 160 224 110 72 2.5 940
ACS880-107-0350A-3 R7i 350 455 200 336 160 262 132 72 3.1 940
ACS880-107-0470A-3 R8i 470 620 250 451 250 352 160 72 4.8 1300
ACS880-107-0640A-3 R8i 640 840 355 614 315 479 250 72 6.7 1300
ACS880-107-0760A-3 R8i 760 990 400 730 400 568 315 72 8 1300
ACS880-107-0900A-3 R8i 900 1080 500 864 450 673 355 72 10 1300
ACS880-107-1250A-3 2×R8i 1250 1630 710 1200 630 935 500 74 13 2600
ACS880-107-1480A-3 2×R8i 1480 1930 800 1421 800 1107 630 74 16 2600
ACS880-107-1760A-3 2×R8i 1760 2120 1000 1690 900 1316 710 74 20 2600
24 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G ACS880-107-2210A-3 3×R8i 2210 2880 1200 2122 1200 1653 900 76 23 3900
ACS880-107-2610A-3 3×R8i 2610 3140 1400 2506 1400 1952 1000 76 30 3900
ACS880-107-3450A-3 4×R8i 3450 4140 1800 3312 1800 2581 1400 76 40 5200
ACS880-107-4290A-3 5×R8i 4290 5150 2400 4118 2000 3209 1800 77 50 6500
— ACS880-107-5130A-3 6×R8i 5130 6160 2800 4925 2400 3837 2000 78 60 7800
2 3
Product series
Types and construction
Rating
Voltage
Options
A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G 19
—
Technical data
Mains connection Environmental limits
Voltage and 3-phase, U N3 380 to 415 V, +10%/-10% Ambient
power range 3-phase, U N5 380 to 500 V, +10%/-10% temperature
3-phase, U N7 525 to 690 V, +10%/-10% Transport -40 to +70 °C
Inverter unit (INU) 1.5 to 5600 kW Storage -40 to +70 °C
Diode supply unit (DSU) 50 to 5500 kVA Operation area 0 to +50 °C, no frost allowed
IGBT supply unit (ISU) 300 to 6100 kVA (air-cooled) +40 to 50 °C with derating of 1% / 1 °C
Regenerative rectifier unit (RRU) 400 to 6100 kVA Cooling method
Frequency 50/60 Hz ±5% Air-cooled Dry clean air
Power factor IGBT supply module (ISU): Altitude
cosϕ = 1 (fundamental) 0 to 1,000 m Without derating
cosϕ = 0.99 (total) 1,000 to 4,000 m With derating of 1% / 100 m 5)
Diode supply module (DSU) and Regenerative Relative humidity 5 to 95%, no condensation allowed
rectifier unit (RRU):
Degree of protection
cosϕ = 0.98 (fundamental)
IP22 Standard (IP20 cabinet doors open)
cosϕ = 0.93 to 0.95 (total)
IP42, IP54 Option
Efficiency 98% with DSU and RRU
(at nominal power) 97.5% with ISU Paint color RAL 9017, RAL 7035
Functional safety
Motor connection
Standard Safe torque off (STO according EN/IEC 61800-5-2)
Voltage 3-phase output voltage 0 to U N3 / U N5 / U N7 IEC 61508 ed2: SIL 3, IEC 61511: SIL 3,
Frequency 0 to ±598 Hz 1) 4) EN/IEC 62061: SIL CL 3, EN ISO 13849-1: PL e
Motor control Direct torque control (DTC) With internal safety Safe stop 1 (SS1), safely-limited speed (SLS),
Torque control Torque step rise time: functions module safe stop emergency (SSE), safe brake control
Open loop <5 ms with nominal torque (SBC) and safe maximum speed (SMS),
Closed loop <5 ms with nominal torque prevention of unexpected startup (POUS),
Non-linearity: Safe direction (SDI), Safe speed monitor (SSM)
Open loop ± 4% with nominal torque EN/IEC 61800-5-2, IEC 61508 ed2: SIL 3,
Closed loop ± 3% with nominal torque IEC 61511: SIL 3
Speed control Static accuracy: EN/IEC 62061: SIL CL 3, EN ISO 13849-1: PL e TÜV
Open loop 10% of motor slip Nord certified 2)
Closed loop 0.01% of nominal speed Safety functions are implemented in the
Dynamic accuracy: multidrives with the safety functions module
Open loop 0.3 to 0.4% seconds with 100% torque step
Closed loop 0.1 to 0.2% seconds with 100% torque step Fieldbus PROFIsafe over profinet, certified
communication
Product compliance
Contamination No conductive dust allowed
CE
levels
Low Voltage Directive 2014/35/EU
Machinery Directive 2006/42/EC Storage IEC 60721-3-1, Class 1C2 (chemical gases),
EMC Directive 2014/30/EU Class 1S2 (solid particles) *)
ATEX Directive 2014/34/EU Operation IEC 60721-3-3, Class 3C2 (chemical gases),
Quality assurance system ISO 9001 and Environmental system ISO Class 3S2 (solid particles) *)
14001 Transportation IEC 60721-3-2, Class 2C2 (chemical gases),
RoHS Class 2S2 (solid particles) *)
UL, EAC/GOST R 3) , cUL 508A or cUL 508C, CSA, RCM
Vibration IEC 60068-2-6, 10 to 57 Hz 0.075 mm
Functional safety: STO TÜV Nord certificate
displacement amplitude 57 to 150 Hz 1 g2
ATEX-certified Safe Disconnection Function, Ex II (2) GD 5)
Marine type approvals
Units with marine construction:
EMC according to EN 61800-3: 2004 + A1: 2012 Max. 1 mm (peak value 2 to 13.2 Hz)
1st environment, restricted distribution category C2, Max. 0.7 g (13.2 to 100 Hz) sinusoidal
as option 1000 A and up to 500 V *) C = Chemically active substances
2nd environment, unrestricted distribution category C3, as option *) S = Mechanically active substances
1)
Operation above 120 Hz might require type specific derating,
please contact your local ABB office
2)
Please check availability per drive type
3)
EAC has replaced GOST R
4)
For higher operational output frequencies please contact
your local ABB office
5)
Derating reduced by lower than 40 oC ambient temperature
20 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
ACS880 multidrives
Inverter
—
01
—
02
Filter
unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
24 VDC
115/230 V AC
Inverter unit
DSU/
RRU/
ISU
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
Inverter unit
AC
A C S 8 8 0 M U LT I D R I V E S 21
—
03 ACS880-104
inverters modules,
frame sizes R1i to R8i
—
03
Multidrives can be used wherever several motors In multimotor applications, for example in a
form part of a single process. With a compact paper machine, the individual inverter modules
module design and high power density, the single provide fast communication of torque and
supply and DC bus arrangement with multiple speed signals between the inverters for
inverters provides many advantages: controlling the tension in the paper web.
• Savings in cabling, installation and Also in cases where the shafts of the individual
maintenance costs motors are not tightly coupled, for example
• Reduced component count and footprint, in sugar centrifuges, each inverter module
as well as increased reliability can be programmed with a speed profile in
• Energy and cost savings. As the energy order to minimize overall energy consumption.
circulates over the common DC bus, all energy These two examples merely demonstrate
is not taken from the supply network. Energy the range of applications where multidrives
circulation can also be used for motor-to-motor offer substantial benefits over other types of
braking without the need for a braking drive constructions. High power units D7T,
chopper or regenerative supply unit. D8T, R6i, R7i and nxR8i have speed controlled
• Reduced line power and currents allowing cooling fans as a standard.
the supply unit to have smaller dimensions.
• The common supply of the multidrives enables
the implementation of overall safety and
control functions.
22 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
01
ACS880 multidrives
• Power ratings: • DC-DC converters (DDC):
-- Inverter units (INU): 1.5 to 5600 kW -- 305 to 1146 kW
-- Diode supply units (DSU): 50 to 5500 kVA • Voltage range:
-- IGBT supply units (ISU): 300 to 6100 kVA -- 380 to 690 V
• Regenerative rectifier units (RRU): • Enclosure classes:
-- 416 to 6100 kVA -- IP22 (as standard), IP42 and IP54
• Brake units:
-- 1-phase Pcont 54 to 714 kW
-- 3-phase Pcont.max 500 to 6500 kW
Multidrives have an extensive selection of built-in features and options. See page 58.
Higlights
• Compact design for easy cabinet assembly and • Device panel for optional switches and pilot
maintenance light
• High packing density, for example 16 units of • Cabinet light and heater option
frame size R2i inverters can be installed into a • Highly efficient thermal handling as heat loss
one meter wide cabinet of each inverter unit is guided to the back of
• Diode bridge that is highly reliable with high the cabinet. All cabinets are their own
power density compartments.
• Fast connectors for motor cables in the bottom • Long lifetime capacitors and high efficiency
part of the cabinet making installation easy cooling fan with speed or on-off control
• Degree of protection IP22, IP42 and IP54 for
different environments
24 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Ratings, types and voltages
Inverter units, UN = 400 V
UN = 400 V (range 380 to 415 V). The power ratings are valid at nominal voltage 400 V (1.5 to 2800 kW).
Drive type Frame Nominal ratings Light overload use Heavy-duty use Noise Heat Air
size level dissipation flow
IN I MAX PN I Ld PLd I Hd PHd
AC AC
(A) (A) (kW) (A) (kW) (A) (kW) (dB(A)) (kW) (m3/h)
Inverter units (INU), ACS880-107
ACS880-107-004A8-3 R1i 4.8 7 1.5 4.5 1.5 4 1.5 47 0.07 24
ACS880-107-006A0-3 R1i 6 8.8 2.2 5.5 2.2 5 1.5 47 0.08 24
ACS880-107-008A0-3 R1i 8 10.5 3 7.6 3 6 2.2 47 0.09 24
ACS880-107-0011A-3 R2i 10.5 13.5 4 9.7 4 9 3 39 0.11 48
ACS880-107-0014A-3 R2i 14 16.5 5.5 13 5.5 11 4 39 0.14 48
ACS880-107-0018A-3 R2i 18 21 7.5 16.8 7.5 14 5.5 39 0.17 48
ACS880-107-0025A-3 R3i 25 33 11 23 11 19 7.5 63 0.2 142
ACS880-107-0035A-3 R3i 35 44 15 32 15 29 11 63 0.3 142
ACS880-107-0044A-3 R3i 44 53 18.5 41 18.5 35 15 71 0.35 200
ACS880-107-0050A-3 R3i 50 66 22 46 22 44 22 71 0.41 200
ACS880-107-0061A-3 R4i 61 78 30 57 30 52 22 70 0.5 290
ACS880-107-0078A-3 R4i 78 100 37 74 37 69 30 70 0.6 290
ACS880-107-0094A-3 R4i 94 124 45 90 45 75 37 70 0.74 290
ACS880-107-0100A-3 R4i 104 125 55 100 55 78 37 70 0.75 290
ACS880-107-0140A-3 R6i 141 183 75 135 75 105 55 71 1.1 650
ACS880-107-0170A-3 R6i 169 220 90 162 90 126 55 71 1.4 650
ACS880-107-0210A-3 R6i 206 268 110 198 110 154 75 71 1.8 650
ACS880-107-0250A-3 R6i 246 320 132 236 132 184 90 71 2 650
ACS880-107-0300A-3 R7i 300 390 160 288 160 224 110 72 2.5 940
ACS880-107-0350A-3 R7i 350 455 200 336 160 262 132 72 3.1 940
ACS880-107-0470A-3 R8i 470 620 250 451 250 352 160 72 4.8 1300
ACS880-107-0640A-3 R8i 640 840 355 614 315 479 250 72 6.7 1300
ACS880-107-0760A-3 R8i 760 990 400 730 400 568 315 72 8 1300
ACS880-107-0900A-3 R8i 900 1080 500 864 450 673 355 72 10 1300
ACS880-107-1250A-3 2×R8i 1250 1630 710 1200 630 935 500 74 13 2600
ACS880-107-1480A-3 2×R8i 1480 1930 800 1421 800 1107 630 74 16 2600
ACS880-107-1760A-3 2×R8i 1760 2120 1000 1690 900 1316 710 74 20 2600
ACS880-107-2210A-3 3×R8i 2210 2880 1200 2122 1200 1653 900 76 23 3900
ACS880-107-2610A-3 3×R8i 2610 3140 1400 2506 1400 1952 1000 76 30 3900
ACS880-107-3450A-3 4×R8i 3450 4140 1800 3312 1800 2581 1400 76 40 5200
ACS880-107-4290A-3 5×R8i 4290 5150 2400 4118 2000 3209 1800 77 50 6500
ACS880-107-5130A-3 6×R8i 5130 6160 2800 4925 2400 3837 2000 78 60 7800
Nominal ratings
IN Rated current available continuously without overloadability at 40 °C.
SN Nominal apparent power.
PN Typical motor power in no-overload use.
Maximum output current
I max Maximum output current. Available for 10 seconds at start, then as long as allowed by drive temperature.
Light-overload use
I Ld Continuous current allowing 110% I Ld for 1 minute every 5 minutes at 40 °C.
P Ld Typical motor power in light-overload use.
Heavy-duty use
I Hd Continuous current allowing 150% I Hd for 1 minute every 5 minutes at 40 °C.
P Hd Typical motor power in heavy-duty use.
The ratings apply at 40 °C ambient temperature. At higher temperatures (up to 50 °C) the derating is 1%/1 °C.
The current ratings are the same regardless of the supply voltage within one voltage range. Dimensioning has to be checked by DriveSize.
R AT I N G S , T Y P E S A N D V O LTA G E S , 4 0 0 V 25
—
Ratings, types and voltages
Supply units, UN = 400 V
UN = 400 V (range 380 to 415 V)
Drive type Frame size Nominal ratings No Light Heavy-duty Noise Heat Air
overload overload use level dissi- flow
use use pation
IN IN I MAX SN PN I Ld PLd I Hd PHd
AC DC DC DC DC DC DC DC
(A) (A) (A) (kVA) (kW) (A) (kW) (A ) (kW) (dB(A)) (kW) (m3/h)
IGBT supply units (ISU), ACS880-207
ACS880-207-0420A-3 R8i+BLCL-13-5 423 513 667 293 290 492 279 384 217 72 9.2 2200
ACS880-207-0580A-3 R8i+BLCL-13-5 576 698 908 399 395 670 379 522 296 72 12 2200
ACS880-207-0810A-3 R8i+BLCL-15-5 810 982 1277 561 556 943 553 735 416 72 17.4 2200
ACS880-207-1130A-3 2×R8i+BLCL-24-5 1125 1364 1773 779 772 1309 741 1020 577 74 21.5 4100
ACS880-207-1330A-3 2×R8i+BLCL-24-5 1332 1615 2100 923 914 1550 877 1208 683 74 23.9 4100
ACS880-207-1580A-3 2×R8i+BLCL-25-5 1584 1921 2497 1097 1086 1844 1043 1437 813 74 31.7 4100
ACS880-207-2350A-3 3×R8i+2×BLCL-24-5 2349 2848 3703 1627 1611 2734 1547 2130 1205 76 47.1 6900
ACS880-207-3110A-3 4×R8i+2×BLCL-25-5 3105 3765 4894 2151 2130 3614 2045 2816 1593 76 63.1 8200
ACS880-207-4620A-3 6×R8i+3×BLCL-25-5 4617 5598 7278 3199 3167 5374 3040 4187 2369 78 94.5 12300
Regenerative rectifier units (RRU), ACS880-907
ACS880-907-0600A-3 1xR8i + BL-15-5 600 727 955 416 393 698 377 544 294 72 8.4 2200
ACS880-907-0900A-3 1xR8i + BL-15-5 900 1091 1433 624 589 1048 566 816 441 72 12.9 2200
ACS880-907-1180A-3 2xR8i + BL-25-5 1180 1431 1879 818 773 1374 742 1070 578 74 15.7 4100
ACS880-907-1770A-3 2xR8i + BL-25-5 1770 2146 2818 1226 1159 2060 1113 1605 867 74 25.2 4100
ACS880-907-2310A-3 4xR8i + 2xBL-25-5 2310 2801 3678 1600 1512 2689 1452 2095 1131 76 31.5 8200
ACS880-907-3460A-3 4xR8i + 2xBL-25-5 3460 4195 5509 2397 2265 4027 2175 3138 1695 76 50.4 8200
ACS880-907-5130A-3 6xR8i + 3xBL-25-5 5130 6220 8168 3554 3359 5971 3225 4653 2512 78 75.6 12300
Diode supply units (DSU), ACS880-307
6-pulse diode
ACS880-307-0080A-3+A003 D6D 1) 80 98 137 55 53 94 51 78 42 62 1.4 720
ACS880-307-0170A-3+A003 D6D 1) 173 212 297 120 114 203 110 170 92 62 2 720
ACS880-307-0330A-3+A003 D7D 1) 327 400 561 227 216 384 208 320 173 62 3 1070
ACS880-307-0490A-3+A003 D7D 1) 490 600 840 339 324 576 311 480 259 62 4.1 1070
ACS880-307-0650A-3+A003 D8D 1) 653 800 1120 452 432 768 415 640 345 65 5.8 1430
ACS880-307-0980A-3+A003 D8D 1) 980 1200 1680 679 648 1152 622 960 519 65 7.6 1430
ACS880-307-0650A-3+A018 D8T 2) 653 800 1120 452 432 768 415 598 323 72 4.6 1300
ACS880-307-0980A-3+A018 D8T 2) 980 1200 1680 679 648 1152 622 898 485 72 6.6 1300
ACS880-307-1210A-3+A018 2×D8T 2) 1215 1488 2083 842 804 1428 771 1113 601 74 9.2 2600
ACS880-307-1820A-3+A018 2×D8T 2) 1823 2232 3125 1263 1205 2143 1157 1670 902 74 13.3 2600
ACS880-307-2730A-3+A018 3×D8T 2) 2734 3348 4687 1894 1808 3214 1736 2504 1352 76 19.9 3900
ACS880-307-3640A-3+A018 4×D8T 2) 3645 4464 6250 2525 2411 4285 2314 3339 1803 76 26.6 5200
ACS880-307-4560A-3+A018 5×D8T 2) 4557 5580 7812 3157 3013 5357 2893 4174 2254 77 33.3 6500
ACS880-307-5470A-3+A018 6×D8T 2) 5468 6696 9374 3788 3616 6428 3471 5009 2705 78 40 7800
12-pulse diode
ACS880-307-0910A-3+A004+A018 2×D7T 3) 912 1116 1562 632 625 1071 600 835 467 74 8.4 1800
ACS880-307-1210A-3+A004+A018 2×D8T 3) 1215 1488 2083 842 833 1428 800 1113 623 74 9.2 2600
ACS880-307-1820A-3+A004+A018 2×D8T 3) 1823 2232 3125 1263 1250 2143 1200 1670 935 74 13.3 2600
ACS880-307-2430A-3+A004+A018 4×D8T 3) 2430 2976 4166 1684 1667 2857 1600 2226 1247 76 18.4 5200
ACS880-307-3640A-3+A004+A018 4×D8T 3) 3645 4464 6250 2525 2500 4285 2400 3339 1870 76 26.6 5200
ACS880-307-5470A-3+A004+A018 6×D8T 3) 5468 6696 9374 3788 3750 6428 3600 5009 2805 78 40 7800
1)
+A003 6-pulse, uncontrolled diode bridge
2)
+A018 6-pulse, half controlled diode bridge
3)
+A004 12-pulse, DSU
26 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Ratings, types and voltages
Inverter units, UN = 500 V
Inverter unit (INU), ACS880-107
UN = 500 V (range 380 to 500 V). The power ratings are valid at nominal voltage 500 V (1.5 to 3200 kW).
Drive type Frame Nominal ratings Light overload use Heavy-duty use Noise Heat Air
size level dissipation flow
IN I MAX PN I Ld PLd I Hd PHd
AC AC
(A) (A) (kW) (A) (kW) (A) (kW) (dB(A)) (kW) (m3/h)
ACS880-107-003A6-5 R1i 3.6 5.3 1.5 3.4 1.5 3 1.5 47 0.06 24
ACS880-107-004A8-5 R1i 4.8 7 2.2 4.5 2.2 4 1.5 47 0.07 24
ACS880-107-006A0-5 R1i 6 8.8 3 5.5 3 5 2.2 47 0.08 24
ACS880-107-008A0-5 R1i 8 10.5 4 7.6 4 6 3 47 0.09 24
ACS880-107-0011A-5 R2i 10.5 13.5 5.5 9.7 5.5 9 4 39 0.13 48
ACS880-107-0014A-5 R2i 14 16.5 7.5 13 7.5 11 5.5 39 0.15 48
ACS880-107-0018A-5 R2i 18 21 11 16.8 11 14 7.5 39 0.18 48
ACS880-107-0025A-5 R3i 25 33 15 23 15 19 11 63 0.23 142
ACS880-107-0030A-5 R3i 30 36 18.5 28 18.5 24 15 63 0.28 142
ACS880-107-0035A-5 R3i 35 44 22 32 22 29 18.5 63 0.32 142
ACS880-107-0050A-5 R3i 50 66 30 46 30 44 22 71 0.48 200
ACS880-107-0061A-5 R4i 61 78 37 57 37 52 30 70 0.55 290
ACS880-107-0078A-5 R4i 78 100 45 74 45 69 45 70 0.65 290
ACS880-107-0094A-5 R4i 94 124 55 90 55 75 45 70 0.8 290
ACS880-107-0110A-5 R6i 113 147 75 108 75 85 55 71 1 650
ACS880-107-0140A-5 R6i 136 177 90 131 90 102 55 71 1.2 650
ACS880-107-0170A-5 R6i 165 215 110 158 110 123 75 71 1.5 650
ACS880-107-0200A-5 R6i 197 256 132 189 132 147 90 71 1.8 650
ACS880-107-0240A-5 R6i 240 312 160 230 160 180 110 71 2 650
ACS880-107-0300A-5 R7i 302 393 200 290 200 226 132 72 2.7 940
ACS880-107-0340A-5 R7i 340 442 250 326 200 254 160 72 3.2 940
ACS880-107-0440A-5 1×R8i 440 580 250 422 250 329 200 72 4.7 1300
ACS880-107-0590A-5 1×R8i 590 770 400 566 355 441 250 72 6.3 1300
ACS880-107-0740A-5 1×R8i 740 970 500 710 450 554 355 72 8.1 1300
ACS880-107-0810A-5 1×R8i 810 1060 560 778 500 606 400 72 9.3 1300
ACS880-107-1150A-5 2×R8i 1150 1500 800 1104 710 860 560 74 12 2600
ACS880-107-1450A-5 2×R8i 1450 1890 1000 1392 900 1085 710 74 16 2600
ACS880-107-1580A-5 2×R8i 1580 2060 1100 1517 1000 1182 800 74 18 2600
ACS880-107-2150A-5 3×R8i 2150 2800 1500 2064 1400 1608 1100 76 24 3900
ACS880-107-2350A-5 3×R8i 2350 3060 1600 2256 1500 1758 1200 76 27 3900
ACS880-107-3110A-5 4×R8i 3110 4050 2000 2986 2000 2326 1600 76 36 5200
ACS880-107-3860A-5 5×R8i 3860 5020 2400 3706 2400 2887 2000 77 44 6500
ACS880-107-4610A-5 6×R8i 4610 6000 3200 4426 2800 3448 2400 78 53 7800
Nominal ratings
IN Rated current available continuously without overloadability at 40 °C.
SN Nominal apparent power.
PN Typical motor power in no-overload use.
Maximum output current
I max Maximum output current. Available for 10 seconds at start, then as long as allowed by drive temperature.
Light-overload use
I Ld Continuous current allowing 110% I Ld for 1 minute every 5 minutes at 40 °C.
P Ld Typical motor power in light-overload use.
Heavy-duty use
I Hd Continuous current allowing 150% I Hd for 1 minute every 5 minutes at 40 °C.
P Hd Typical motor power in heavy-duty use.
The ratings apply at 40 °C ambient temperature. At higher temperatures (up to 50 °C) the derating is 1%/1 °C.
The current ratings are the same regardless of the supply voltage within one voltage range. Dimensioning has to be checked by DriveSize.
R AT I N G S , T Y P E S A N D V O LTA G E S , 5 0 0 V 27
—
Ratings, types and voltages
Supply units, UN = 500 V
Supply unit
UN = 500 V (range 380 to 500 V)
Drive type Frame size Nominal ratings No Light Heavy-duty Noise Heat Air
overload overload use level dissi- flow
use use pation
IN IN I MAX SN PN I Ld PLd I Hd PHd
AC DC DC DC DC DC DC DC
(A) (A) (A) (kVA) (kW) (A) (kW) (A ) (kW) (dB(A)) (kW) (m3/h)
IGBT supply units (ISU), ACS880-207
ACS880-207-0400A-5 R8i+BLCL-13-5 396 480 624 343 340 461 326 359 254 72 9.2 2200
ACS880-207-0530A-5 R8i+BLCL-13-5 531 644 837 460 455 618 437 482 341 72 11.5 2200
ACS880-207-0730A-5 R8i+BLCL-15-5 729 884 1149 631 625 849 600 661 468 72 16.7 2200
ACS880-207-1040A-5 2×R8i+BLCL-24-5 1035 1255 1631 896 887 1205 852 939 664 74 20.7 4100
ACS880-207-1420A-5 2×R8i+BLCL-25-5 1422 1724 2241 1231 1219 1655 1170 1290 912 74 29.3 4100
ACS880-207-2120A-5 3×R8i+2×BLCL-24-5 2115 2564 3334 1832 1813 2462 1741 1918 1356 76 43.8 6900
ACS880-207-2800A-5 4×R8i+2×BLCL-25-5 2799 3394 4412 2424 2400 3258 2304 2539 1795 76 58.4 8200
ACS880-207-4150A-5 6×R8i+3×BLCL-25-5 4149 5031 6540 3593 3557 4829 3415 3763 2661 78 87.4 12300
UN = 500 V (range 230 to 525 V)
Regenerative rectifier units (RRU), ACS880-907
ACS880-907-0600A-5 1xR8i + BL-15-5 600 727 955 520 491 698 471 544 367 72 8.5 2200
ACS880-907-0900A-5 1xR8i + BL-15-5 900 1091 1433 779 737 1047 707 816 551 72 13 2200
ACS880-907-1180A-5 2xR8i + BL-25-5 1180 1431 1879 1022 966 1374 927 1 070 722 74 16.1 4100
ACS880-907-1770A-5 2xR8i + BL-25-5 1770 2146 2818 1533 1449 2060 1391 1 605 1084 74 25.6 4100
ACS880-907-2310A-5 4xR8i + 2xBL-25-5 2310 2801 3678 2001 1891 2689 1815 2 095 1414 76 32.2 8200
ACS880-907-3460A-5 4xR8i + 2xBL-25-5 3460 4195 5509 2996 2832 4027 2719 3 138 2118 76 51.1 8200
ACS880-907-5130A-5 6xR8i + 3xBL-25-5 5130 6220 8168 4443 4199 5971 4031 4 653 3141 78 76.7 12300
Diode supply units (DSU), ACS880-307
6-pulse diode
ACS880-307-0080A-5+A003 D6D 1) 80 98 137 69 66 94 63 78 53 62 1.4 720
ACS880-307-0170A-5+A003 D6D 1) 173 212 297 150 143 203 137 170 114 62 2 720
ACS880-307-0330A-5+A003 D7D 1) 327 400 561 283 270 384 260 320 216 62 3 1070
ACS880-307-0490A-5+A003 D7D 1) 490 600 840 424 405 576 389 480 324 62 4.1 1070
ACS880-307-0650A-5+A003 D8D 1)
653 800 1120 566 540 768 518 640 432 65 5.8 1430
ACS880-307-0980A-5+A003 D8D 1) 980 1200 1680 849 810 1152 778 960 648 65 7.6 1430
ACS880-307-0650A-5+A018 D8T 2) 653 800 1120 566 540 768 518 598 404 72 4.6 1300
ACS880-307-0980A-5+A018 D8T 2) 980 1200 1680 849 810 1152 778 898 606 72 6.6 1300
ACS880-307-1210A-5+A018 2×D8T 2) 1215 1488 2083 1052 1004 1428 964 1113 751 74 9.2 2600
ACS880-307-1820A-5+A018 2×D8T 2) 1823 2232 3125 1579 1507 2143 1446 1670 1127 74 13.3 2600
ACS880-307-2730A-5+A018 3×D8T 2) 2734 3348 4687 2368 2260 3214 2170 2504 1690 76 19.9 3900
ACS880-307-3640A-5+A018 4×D8T 2) 3645 4464 6250 3157 3013 4285 2893 3339 2254 76 26.6 5200
ACS880-307-4560A-5+A018 5×D8T 2) 4557 5580 7812 3946 3767 5357 3616 4174 2817 77 33.3 6500
ACS880-307-5470A-5+A018 6×D8T 2) 5468 6696 9374 4735 4520 6428 4339 5009 3381 78 40 7800
12-pulse diode
ACS880-307-0910A-5+A004+A018 2×D7T 3) 912 1116 1562 790 781 1071 750 835 584 74 8.4 1800
ACS880-307-1210A-5+A004+A018 2×D8T 3) 1215 1488 2083 1052 1042 1428 1000 1113 779 74 9.2 2600
ACS880-307-1820A-5+A004+A018 2×D8T 3) 1823 2232 3125 1579 1562 2143 1500 1670 1169 74 13.3 2600
ACS880-307-2430A-5+A004+A018 4×D8T 3) 2430 2976 4166 2104 2083 2857 2000 2226 1558 76 18.4 5200
ACS880-307-3640A-5+A004+A018 4×D8T 3) 3645 4464 6250 3157 3125 4285 3000 3339 2337 76 26.6 5200
ACS880-307-5470A-5+A004+A018 6×D8T 3) 5468 6696 9374 4735 4687 6428 4500 5009 3506 78 40 7800
1)
+A003 6-pulse, uncontrolled diode bridge
2)
+A018 6-pulse, half controlled diode bridge
3)
+A004 12-pulse, DSU
28 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Ratings, types and voltages
Inverter units, UN = 690 V
Inverter unit (INU), ACS880-107
UN = 690 V (range 525 to 690 V). The power ratings are valid at nominal voltage 690 V (4 to 5600 kW).
Drive type Frame Nominal ratings Light overload use Heavy-duty use Noise Heat Air
size level dissipation flow
IN I max PN I Ld PLd I Hd PHd
AC AC
(A) (A) (kW) (A) (kW) (A) (kW) (dB(A)) (kW) (m3/h)
ACS880-107-007A3-7 R5i 7.3 9.5 5.5 6.9 5.5 5.6 4 62 0.22 280
ACS880-107-009A8-7 R5i 9.8 12.7 7.5 9.3 7.5 7.3 5.5 62 0.28 280
ACS880-107-014A2-7 R5i 14.2 18.5 11 13.5 11 9.8 7.5 62 0.4 280
ACS880-107-0018A-7 R5i 18 23.4 15 17.1 15 14.2 11 62 0.49 280
ACS880-107-0022A-7 R5i 22 29 18.5 20.9 18.5 18 15 62 0.58 280
ACS880-107-0027A-7 R5i 27 35 22 25.7 22 22 18.5 62 0.66 280
ACS880-107-0035A-7 R5i 35 46 30 33.3 30 27 22 62 0.86 280
ACS880-107-0042A-7 R5i 42 55 37 39.9 37 35 30 62 1 280
ACS880-107-0052A-7 R5i 52 68 45 49.4 45 42 37 62 1.12 280
ACS880-107-0062A-7 R6i 62 81 55 60 55 46 45 71 0.8 650
ACS880-107-0082A-7 R6i 82 107 75 79 75 61 55 71 1.1 650
ACS880-107-0100A-7 R6i 99 129 90 95 90 74 75 71 1.3 650
ACS880-107-0130A-7 R6i 125 163 110 120 110 94 75 71 1.5 650
ACS880-107-0140A-7 R6i 144 187 132 138 132 108 90 71 1.8 650
ACS880-107-0190A-7 R6i 192 250 160 184 160 144 132 71 2.5 650
ACS880-107-0220A-7 R7i 217 282 200 208 200 162 160 72 2.8 940
ACS880-107-0270A-7 R7i 270 351 250 259 250 202 200 72 3.3 940
ACS880-107-0340A-7 R8i 340 510 315 326 250 254 200 72 5.2 1300
ACS880-107-0410A-7 R8i 410 620 400 394 355 307 250 72 6.1 1300
ACS880-107-0530A-7 R8i 530 800 500 509 450 396 355 72 7.9 1300
ACS880-107-0600A-7 R8i 600 900 560 576 560 449 400 72 9 1300
ACS880-107-0800A-7 2×R8i 800 1200 800 768 710 598 560 74 12 2600
ACS880-107-1030A-7 2×R8i 1030 1550 1000 989 900 770 710 74 15 2600
ACS880-107-1170A-7 2×R8i 1170 1760 1100 1123 1000 875 800 74 18 2600
ACS880-107-1540A-7 3×R8i 1540 2310 1400 1478 1400 1152 1100 76 23 3900
ACS880-107-1740A-7 3×R8i 1740 2610 1600 1670 1600 1302 1200 76 26 3900
ACS880-107-2300A-7 4×R8i 2300 3450 2000 2208 2000 1720 1600 76 35 5200
ACS880-107-2860A-7 5×R8i 2860 4290 2800 2746 2400 2139 2000 77 43 6500
ACS880-107-3420A-7 6×R8i 3420 5130 3200 3283 3200 2558 2400 78 52 7800
ACS880-107-3990A-7 7×R8i 3990 5990 3600 3830 3600 2985 2800 78 60 9100
ACS880-107-4560A-7 8×R8i 4560 6840 4400 4378 4000 3411 3200 79 69 10400
ACS880-107-5130A-7 9×R8i 5130 7700 4800 4925 4800 3837 3600 79 78 11700
ACS880-107-5700A-7 10×R8i 5700 8550 5600 5472 5200 4264 4000 79 86 13000
Nominal ratings
IN Rated current available continuously without overloadability at 40 °C.
SN Nominal apparent power.
PN Typical motor power in no-overload use.
Maximum output current
I max Maximum output current. Available for 10 seconds at start, then as long as allowed by drive temperature.
Light-overload use
I Ld Continuous current allowing 110% I Ld for 1 minute every 5 minutes at 40 °C.
P Ld Typical motor power in light-overload use.
Heavy-duty use
I Hd Continuous current allowing 150% I Hd for 1 minute every 5 minutes at 40 °C.
P Hd Typical motor power in heavy-duty use.
The ratings apply at 40 °C ambient temperature. At higher temperatures (up to 50 °C) the derating is 1%/1 °C.
The current ratings are the same regardless of the supply voltage within one voltage range. Dimensioning has to be checked by DriveSize.
R AT I N G S , T Y P E S A N D V O LTA G E S , 6 9 0 V 29
—
Ratings, types and voltages
Supply units, UN = 690 V
Supply unit
UN = 690 V (range 525 to 690 V)
Drive type Frame size Nominal ratings No Light Heavy-duty Noise Heat Air
overload overload use level dissi- flow
use use pation
IN IN I max SN PN I Ld PLd I Hd PHd
AC DC DC DC DC DC DC DC
(A) (A) (A) (kVA) (kW) (A) (kW) (A ) (kW) (dB(A)) (kW) (m3/h)
IGBT supply units (ISU), ACS880-207
ACS880-207-0310A-7 R8i+BLCL-13-7 306 371 557 366 362 356 348 278 271 72 11.7 2200
ACS880-207-0370A-7 R8i+BLCL-13-7 369 447 671 441 437 430 419 335 327 72 13.4 2200
ACS880-207-0540A-7 R8i+BLCL-15-7 540 655 982 645 639 629 613 490 478 72 17.6 2200
ACS880-207-0720A-7 2×R8i+BLCL-24-7 720 873 1309 860 852 838 818 653 637 74 23 4100
ACS880-207-1050A-7 2×R8i+BLCL-25-7 1053 1277 1915 1258 1246 1226 1196 955 932 74 31.5 4100
ACS880-207-1570A-7 3×R8i+2×BLCL-24-7 1566 1899 2848 1872 1853 1823 1779 1420 1386 76 49.4 6900
ACS880-207-2070A-7 4×R8i+2×BLCL-25-7 2070 2510 3765 2474 2449 2409 2351 1877 1832 76 62.7 8200
ACS880-207-3080A-7 6×R8i+3×BLCL-25-7 3078 3732 5598 3679 3642 3583 3496 2792 2724 78 94 12300
ACS880-207-4100A-7 8×R8i+4×BLCL-25-7 4104 4976 7464 4905 4856 4777 4661 3722 3632 79 125.3 16400
ACS880-207-5130A-7 10×R8i+5×BLCL-25-7 5130 6220 9330 6131 6070 5971 5827 4653 4540 79 155.5 20500
Regenerative rectifier units (RRU), ACS880-907
ACS880-907-0600A-7 1×R8i + BL-15-7 600 727 1102 717 678 698 651 544 507 72 9.8 2200
ACS880-907-0900A-7 1×R8i + BL-15-7 900 1 091 1653 1076 1016 1 048 976 816 760 72 14.3 2200
ACS880-907-1180A-7 2×R8i + BL-25-7 1180 1 431 2168 1410 1333 1 374 1 279 1 070 997 74 18.5 4100
ACS880-907-1770A-7 2×R8i + BL-25-7 1770 2 146 3252 2115 1999 2 060 1 919 1 605 1495 74 28.1 4100
ACS880-907-2310A-7 4×R8i + 2xBL-25-7 2310 2 801 4244 2761 2609 2 689 2 505 2 095 1952 76 37.1 8200
ACS880-907-3460A-7 4×R8i + 2xBL-25-7 3460 4 195 6356 4135 3908 4 027 3 752 3 138 2923 76 56.2 8200
ACS880-907-5130A-7 6×R8i + 3xBL-25-7 5130 6 220 9424 6131 5794 5 971 5562 4 653 4334 78 84.3 12300
Diode supply units (DSU), ACS880-307
6-pulse diode
ACS880-307-0570A-7+A018 D8T 1) 572 700 980 684 652 672 626 524 488 72 4.5 1300
ACS880-307-0820A-7+A018 D8T 1) 817 1000 1400 976 932 960 894 748 697 72 5.8 1300
ACS880-307-1060A-7+A018 2×D8T 1) 1064 1302 1823 1272 1213 1250 1164 974 907 74 9 2600
ACS880-307-1520A-7+A018 2×D8T 1) 1519 1860 2604 1815 1733 1786 1663 1391 1296 74 12.7 2600
ACS880-307-2280A-7+A018 3×D8T 1) 2279 2790 3906 2724 2599 2678 2495 2087 1944 76 19.1 3900
ACS880-307-3040A-7+A018 4×D8T 1) 3038 3720 5208 3631 3465 3571 3327 2783 2592 76 25.5 5200
ACS880-307-3800A-7+A018 5×D8T 1) 3797 4650 6510 4538 4331 4464 4158 3478 3240 77 32 6500
ACS880-307-4560A-7+A018 6×D8T 1) 4557 5580 7812 5446 5198 5357 4990 4174 3888 78 38.4 7800
12-pulse diode
ACS880-307-0760A-7+A004+A018 2×D7T 2) 760 930 1302 908 898 893 862 696 672 74 7.7 1800
ACS880-307-1060A-7+A004+A018 2×D8T 2) 1064 1302 1823 1272 1258 1250 1207 974 941 74 9 2600
ACS880-307-1520A-7+A004+A018 2×D8T 2) 1519 1860 2604 1815 1797 1786 1725 1391 1344 74 12.7 2600
ACS880-307-2130A-7+A004+A018 4×D8T 2)
2127 2604 3646 2542 2515 2500 2415 1948 1882 76 18.1 5200
ACS880-307-3040A-7+A004+A018 4×D8T 2) 3038 3720 5208 3631 3594 3571 3450 2783 2688 76 25.5 5200
ACS880-307-4560A-7+A004+A018 6×D8T 2) 4557 5580 7812 5446 5390 5357 5175 4174 4032 78 38.4 7800
1)
+A018 6-pulse, half controlled diode bridge
2)
+A004 12-pulse, DSU
30 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Dimensions
ACS880 multidrives
Supply units. Dimensions include ACU, ICU and ISU/RRU/DSU. Supply units. Dimensions include ACU, ICU and ISU/RRU/DSU.
Frame size Height Width Depth Weight Frame Height Width Depth Weight
(mm) (mm) (mm) (kg) size (mm) (mm) (mm) (kg)
ACS880-207 IGBT supply unit (ISU) ACS880-307 diode supply unit (DSU)
Limited 6-pulse diode
2145 1000 636 810
scope 1)
R8i+BLCL-13-5 D6D 2145 400 636 300
Standard
2145 1600 636 1300 D7D 2145 400 636 350
scope 1)
Limited D8D 2145 700 636 550
scope 1) 2145 1000 636 860 D8T 2145 1400 636 850
R8i+BLCL-15-5
Standard 1060A-7 2145 1400 636 1130
2145 1600 636 1300
scope 1)
2×D8T 1210A-3/5,
1040A-5 2145 1800 636 1600 1820A-3/5, 2145 1600 636 1130
2×R8i+BLCL-24-5 1130A-3, 1520A-7
2145 2000 636 1720
1330A-3 3×D8T 2145 2000 636 1560
2×R8i+BLCL-25-5 2145 2000 636 1720 690 V drives 2145 2400 636 1940
3×R8i+2xBLCL-24-5 2145 2600 636 2410 4×D8T 400/500 V
2145 2800 636 2140
4×R8i+2xBLCL-25-5 2145 2800 636 2820 drives
6×R8i+3xBLCL-25-5 2145 4000 636 3960 5×D8T 2145 3000 636 2420
R8i+BLCL-13-7 2145 1600 636 1300 6×D8T 2145 3200 636 2700
2×R8i+BLCL-24-7 2145 1800 636 1600 2×D7T 2145 1800 636 900
2×R8i+BLCL-25-7 2145 1800 636 1600 2×D8T 2145 1800 636 1180
2430A-3/5,
3×R8i+2×BLCL-25-7 2145 2600 636 2210 2145 2400 636 1840
2130A-7
4×R8i+2xBLCL-25-7 2145 2800 636 2820 4×D8T 3640A-3,
6×R8i+3xBLCL-25-7 2145 3600 636 3720 3650A-5 2145 3000 636 2040
8×R8i+4xBLCL-25-7 2145 5100 636 4860 3040A-7
10×R8i+5xBLCL-25-7 2145 5900 636 5760 6×D8T 2145 3400 636 2900
W
D
32 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Control panel options
— Bluetooth control panel, ACS-AP-W The Bluetooth connection enables the use of
01 Assistant control
panel with Bluetooth Commissioning and operation of the ACS880 is mobile apps like Drivetune. This app is available
— easy with the assistant control panel. The panel for free on the Google Play and the Apple App
02 Control panel
mounting platform has a multilingual graphical display, Bluetooth store. Drivetune features include: commissioning,
DPMP-01 connectivity and a USB interface for PC tool troubleshooting, monitoring and controlling the
connection. The panel can be used with all drives drive remotely. Drivetune also has full parameter
belonging to ABB’s all-compatible product access and backup and restore functionality.
portfolio.
Control panel mounting platform, DPMP-01
There is no need to know any drive parameters, The DPMP-01 mounting platform is for flush
as the control panel helps you set up the essential mountings.
settings quickly and get the drive into action.
— —
01 02
—
Control panel options
—
Connectivity to automation systems
— —
01 ACS880 is Fieldbus adapter modules Connectivity adapters
compatible with many
ACS880 industrial drives are compatible
fieldbus protocols
— with a wide range of fieldbus protocols. Option
02 Input/output code 2) Fieldbus protocol Adapter
The drive comes with a Modbus RTU fieldbus
extension modules +K451 DeviceNet™ FDNA-01
interface as standard.
+K454 PROFIBUS DP. DPV0/DPV1 FPBA-01
+K457 CANopen® FCAN-01
The ACS880 supports two different
+K458 Modbus RTU FSCA-01
fieldbus connections simultaneously and
+K462 ControlNet FCNA-01
offers the possibility for redundant fieldbus
communication. PROFIsafe (functional +K469 EtherCAT® FECA-01
— —
01 02
—
Input/output extension modules Analog and digital input/output extension modules
Standard input and output can be extended
by using optional analog and digital input/output Option code Description I/O module
extension modules. The modules are easily +L501 4×DI/O, 2×RO FIO-01
installed in the extension slots located on +L500 3×AI (mA/V), 1×AO (mA), FIO-11
2×DI/O
the drive.
+L515 2×F-type option FEA-03
extension slots
If there are not enough I/O extension slots in +L525 2×AI(mA/V), 2×AO(mA) FAIO-01
the drive, the FEA-03 module can increase the +L526 3×DI (up to 250 V DC or FDIO-01
number of slots. The FEA-03 has two option slots 230 V AC), 2×RO
for digital I/O extensions and speed feedback
interface modules. The connection to the control
unit is via an optical fiber link, and the adapter
can be mounted on a DIN rail (35 × 7.5 mm).
A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G 35
—
PC tool options
—
03 Drive composer pro PC tools
PC tool
The Drive composer pro PC tool offers fast and
harmonized setup, commissioning and
monitoring for ABB’s all-compatible drives.
The tool provides startup and maintenance
capabilities, and includes support for adaptive
programming. It also gathers all drive
information, such as parameter loggers, faults,
backups and event lists, into a support
diagnostics file.
—
PC tools
—
Remote monitoring options
— —
01 02
—
Additional interface options
— —
03 04
—
Safety options
— Integrated safety
01 FSO-12 safety
functions module Integrated safety reduces the need for external
safety components, simplifying configuration
and reducing installation space. The safety
functionality is a built-in feature of the ACS880,
with safe torque off (STO) as standard.
The STO function corresponds to an uncontrolled
stop in accordance with stop category 0 of
EN 60204-1. Additional safety functions can be
commissioned with the optional and compact
safety functions module. ACS880 drives offer
functional safety with or without encoder.
The drivesʼ functional safety is designed in
accordance with EN/IEC 61800-5-2 and complies
with the requirements of the European Union
Machinery Directive (2006/42/EC).
—
Safety function modules
—
EMC – electromagnetic compatibility
— Each ACS880 model can be equipped with a to EMC standards according to the table
01 Immunity and
emission compatibility built-in filter to reduce high-frequency emissions. on the next page.
Disturbance level
Immunity level
Immunity limit
Compatibility
margin
Emission limit
Emission level
—
Independent variable e.g. frequency
01
E M C – E L E C T R O M A G N E T I C C O M PAT I B I L I T Y 41
EMC standards
EMC according to EN 61800-3:2004 + EN 61800-3 EN 55011, product family EN 61000-6-4, generic EN 61000-6-3, generic
A1:2012 product standard product standard for industrial, emission standard for emission standard for
standard scientific and medical (ISM) industrial environments residential, commercial and
equipment light-industrial environment
1st environment, unrestricted distribution Category C1 Group 1. Class B Not applicable Applicable
1st environment, restricted distribution Category C2 Group 1. Class A Applicable Not applicable
2nd environment, unrestricted distribution Category C3 Group 2. Class A Not applicable Not applicable
2nd environment, restricted distribution Category C4 Not applicable Not applicable Not applicable
—
Choose the right motor
for your application
—
Losses
The idea is simple. Take a conventional, proven power losses. Because the footprints are
stator technology and a totally new, innovative identical, it is easy to replace an induction
rotor design. Then combine them with a drive motor with a SynRM motor.
loaded with new, application-specific software.
Finally, optimize the whole package for IE4 synchronous reluctance motors have
applications such as pumps, fans, compressors, very low winding temperatures, which
extruders, conveyors and mixers. increases the reliability and life of the winding.
More importantly, the cooler synchronous
Synchronous reluctance technology combines reluctance rotor means significantly lower
the performance of a permanent magnet motor bearing temperatures – an important factor,
with the simplicity and service-friendliness of because bearing failures cause about 70% of
an induction motor. The new rotor has neither unplanned motor outages.
magnets nor windings and suffers virtually no
Cost of
ownership
—
Sine filters
— Together with a sine filter, ACS880 drives The ACS880 inverter and sine filter solution can
01 For step-up
applications, e.g. where offer smooth motor operation. The sine filter be used together with a variety of requirements
medium voltage motor suppresses the high-frequency components for products and components:
needs to be driven
of the motors output voltage, creating almost • For motors without adequate insulation
a sinusoidal voltage wave form for the motor. for the role
The filter offers an optimized LC design that • Where the total motor cable length is long as
takes into account the switching frequency, a result of a number of parallel motors
voltage drop and filtering characteristics. • For step-up applications, e.g. where a
medium voltage motor needs to be driven
• For submersible pumps with long motor
cables, e.g. in the oil industry
• When the motor noise needs to be reduced
• When there are industry-specific requirements
for peak voltage level and voltage rise time
—
01
ACS880 Sine
filter 2 to 13.8 kV AC
2 to 13.8 kV AC
Step-down Step-down
transformer transformer
S I N E F I LT E R S 45
IN PN Noise level Inverter type Filter type Filter height Filter width Filter depth Filter weight Frame size
(A) (kW) (dB) (mm) (mm) (mm) (kg)
U N = 400 V (range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
470 250 80 ACS880-107-0470A-3 NSIN-0900-6 2145 1000 636 550 R8i
640 355 80 ACS880-107-0640A-3 NSIN-0900-6 2145 1000 636 550 R8i
760 400 80 ACS880-107-0760A-3 NSIN-0900-6 2145 1000 636 550 R8i
900 500 81 ACS880-107-0900A-3 NSIN-1380-6 2145 1000 636 750 R8i
1250 630 82 ACS880-107-1250A-3 2×NSIN-0900-6 2145 1000 636 1100 2×R8i
1480 800 82 ACS880-107-1480A-3 2×NSIN-0900-6 2145 2000 636 1100 2×R8i
1760 1000 82 ACS880-107-1760A-3 2×NSIN-1380-6 2145 2000 636 1500 2×R8i
2210 1200 82 ACS880-107-2210A-3 2×NSIN-1380-6 2145 2000 636 1500 3×R8i
2610 1400 83 ACS880-107-2610A-3 3×NSIN-1380-6 2145 3000 636 2250 3×R8i
3450 1800 83 ACS880-107-3450A-3 3×NSIN-1380-6 2145 3000 636 2250 4×R8i
4290 2400 84 ACS880-107-4290A-3 4×NSIN-1380-6 2145 4000 636 3000 5×R8i
5130 2800 85 ACS880-107-5130A-3 5×NSIN-1380-6 2145 5000 636 3750 6×R8i
U N = 500 V (range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
440 250 80 ACS880-107-0440A-5 NSIN-0485-6 2145 400 636 350 R8i
590 400 80 ACS880-107-0590A-5 NSIN-0900-6 2145 1000 636 550 R8i
740 500 80 ACS880-107-0740A-5 NSIN-0900-6 2145 1000 636 550 R8i
810 560 81 ACS880-107-0810A-5 NSIN-1380-6 2145 1000 636 750 R8i
1150 800 81 ACS880-107-1150A-5 NSIN-1380-6 2145 1000 636 750 2×R8i
1450 1000 82 ACS880-107-1450A-5 2×NSIN-0900-6 2145 2000 636 1100 2×R8i
1580 1100 82 ACS880-107-1580A-5 2×NSIN-1380-6 2145 2000 636 1500 2×R8i
2150 1500 82 ACS880-107-2150A-5 2×NSIN-1380-6 2145 2000 636 1500 3×R8i
2350 1600 83 ACS880-107-2350A-5 3×NSIN-1380-6 2145 3000 636 2250 3×R8i
3110 2000 83 ACS880-107-3110A-5 3×NSIN-1380-6 2145 3000 636 2250 4×R8i
3860 2400 84 ACS880-107-3860A-5 4×NSIN-1380-6 2145 4000 636 3000 5×R8i
4610 3200 85 ACS880-107-4610A-5 5×NSIN-1380-6 2145 5000 636 3750 6×R8i
U N = 690 V (range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
340 315 80 ACS880-107-0340A-7 NSIN-0485-6 2145 400 636 350 R8i
410 400 80 ACS880-107-0410A-7 NSIN-0485-6 2145 400 636 350 R8i
530 500 80 ACS880-107-0530A-7 NSIN-0900-6 2145 1000 636 550 R8i
600 560 80 ACS880-107-0600A-7 NSIN-0900-6 2145 1000 636 550 R8i
800 800 80 ACS880-107-0800A-7 NSIN-0900-6 2145 1000 636 550 2×R8i
1030 1000 81 ACS880-107-1030A-7 NSIN-1380-6 2145 1000 636 750 2×R8i
1170 1100 81 ACS880-107-1170A-7 NSIN-1380-6 2145 1000 636 750 2×R8i
1540 1400 82 ACS880-107-1540A-7 2×NSIN-1380-6 2145 2000 636 1500 3×R8i
1740 1600 82 ACS880-107-1740A-7 2×NSIN-1380-6 2145 2000 636 1500 3×R8i
2300 2000 82 ACS880-107-2300A-7 2×NSIN-1380-6 2145 2000 636 1500 4×R8i
2860 2800 83 ACS880-107-2860A-7 3×NSIN-1380-6 2145 3000 636 2250 5×R8i
3420 3200 83 ACS880-107-3420A-7 3×NSIN-1380-6 2145 3000 636 2250 6×R8i
3990 3600 84 ACS880-107-3990A-7 4×NSIN-1380-6 2145 4000 636 3000 7×R8i
4560 4400 84 ACS880-107-4560A-7 4×NSIN-1380-6 2145 4000 636 3000 8×R8i
5130 4800 85 ACS880-107-5130A-7 5×NSIN-1380-6 2145 5000 636 3750 9×R8i
5700 5600 86 ACS880-107-5700A-7 6×NSIN-1380-6 2145 6000 636 4500 10×R8i
Nominal ratings
IN Rated current of the drive-filter combination available continuously without overload at 40 °C.
PN Typical motor power
46 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Brake options
— Brake unit
01 NBRA659 brake unit Dynamic braking unit
The brake unit is a cabinet-built option. It handles
A brake chopper for application where high
the energy generated by a decelerating motor.
continuous braking power is needed.
The brake chopper connects the brake resistor to
The power range is 500 to 6500 kW.
the intermediate DC circuit whenever the voltage
in the circuit exceeds the limit defined by the
control program. Energy consumption by the
resistor losses lowers the voltage until the
resistor can be disconnected.
—
ACS880-607, 1-phase brake units
Ratings
Er Energy pulse that the resistor assembly will withstand with the 400 seconds duty cycle.
This energy will heat the resistor element from 40 °C to the maximum allowable temperature.
P br.max Maximum braking power of the NBRA-6xx chopper and SAFUR resistor combination.
Note: The braking energy transmitted to the resistor during any period shorter than 400 seconds may not exceed E r.
Thus, the standard resistor withstands continuous braking of P br. max typically 20 to 40 seconds (t = E r /P br,max ) during
the total cycle time of 400 s.
R Recommended braking resistor resistance. Also nominal resistance of corresponding SAFUR resistor.
Dedicated resistor for each brake chopper.
I max Maximum peak current per chopper during braking. Current is achieved with minimum resistor resistance.
I rms Corresponding rms current per chopper during load cycle.
Heat loss of brake chopper is 1% of braking power. Heat loss of section with brake resistors is the same as braking power.
1)
Additional 200 mm junction section needed.
2)
2130 mm + additional 10 mm is required for marine supports.
3)
Total width of the line-up is the sum of widths of the sections + 30 mm for the end plates.
*) D151 = braking resistor, degree of protection IP22 and IP42 only
48 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
ACS880-607, 3-phase dynamic brake units
Dimensions
Frame size Height 1) Width bottom exit Width top exit Depth Noise level 2) Air flow
(mm) (mm) (mm) (mm) (dB(A)) (m3/h)
R8i 2145 500 700 636 72 1300
R8i 2145 500 700 636 72 1300
2×R8i 2145 1000 1400 636 74 2600
2×R8i 2145 1000 1400 636 74 2600
3×R8i 2145 1500 2100 636 76 3900
4×R8i 2145 2000 2800 636 76 5200
5×R8i 2145 2500 3500 636 77 6500
IP21 and IP42. IP54 additional 170 mm to the height of each R8i cabinet.
1)
Resistor
R min Minimum allowed resistance value of the brake resistor for one phase of the brake module.
R max Resistance value of the brake resistor for one phase of the brake module corresponding to the maximum
achieved continuous braking power.
Note: Connect one resistor per brake module phase.
For example, a brake unit of frame size 2×R8i including two brake modules → 2×3 resistors are needed.
Typical ratings for no-overload use
I dc Total input DC current of brake unit.
I rms Total rms DC output phase current of brake unit.
I max Peak brake current (DC) per chopper module phase.
Pcont.max Maximum continuous braking power per brake unit.
Cyclic load (1 min/5 min)
I dc Total input DC current of brake unit during a period of 1 minute with braking power P br.
I rms Total rms DC current per brake unit phase during a period of 1 minute with braking power P br.
P br Short term braking power
50 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
DC-DC converter ACS880-1607
U N = 400 V (range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
No-overload use Short time Heavy overload Noise Heat Air Filter type Drive type Frame
overload cycle cycle level dissipation flow ACS880-1607- size
(10 s/60 s) (1 min/5 min)
I dc input I rms output I max output I p2p I short time Pshort time I Hd PHd
DC DC PN DC
(A) (A) (kW) (A) (A) (A) (kW) (A) (kW) (dB(A)) (kW) (m3/h)
600 600 305 900 22 450 229 510 260 74 5.2 2200 BDCL-14-5 0600A-3 R8i
900 900 458 1350 33 675 343 765 389 74 8 2200 BDCL-15-5 0900A-3 R8i
1200 1200 611 1800 44 899 458 1020 519 76 10.5 4400 2xBDCL-14-5 1200A-3 2xR8i
1800 1800 916 2700 65 1349 687 1529 779 76 10.5 4400 2xBDCL-15-5 1800A-3 2xR8i
U N = 500 V (range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
No-overload use Short time Heavy overload Noise Heat Air Filter type Drive type Frame
overload cycle cycle level dissipation flow ACS880-1607- size
(10 s/60 s) (1 min/5 min)
I dc input I rms output I max output I p2p I short time Pshort time I Hd PHd
DC DC PN DC
(A) (A) (kW) (A) (A) (A) (kW) (A) (kW) (dB(A)) (kW) (m3/h)
600 600 382 900 27 450 286 510 324 74 6 2200 BDCL-14-5 0600A-5 R8i
900 900 573 1350 41 675 429 765 487 74 9.1 2200 BDCL-15-5 0900A-5 R8i
1200 1200 764 1800 55 899 572 1020 649 76 12.1 4400 2xBDCL-14-5 1200A-5 2xR8i
1800 1800 1146 2700 82 1349 859 1529 973 76 18.8 4400 2xBDCL-15-5 1800A-5 2xR8i
U N = 690 V (range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
No-overload use Short time Heavy overload Noise Heat Air Filter type Drive type Frame
overload cycle cycle level dissipation flow ACS880-1607- size
(10 s/60 s) (1 min/5 min)
I dc input I rms output I max output I p2p I short time Pshort time I Hd PHd
DC DC PN DC
(A) (A) (kW) (A) (A) (A) (kW) (A) (kW) (dB(A)) (kW) (m3/h)
400 400 351 600 38 300 263 340 298 74 6.4 2200 BDCL-14-7 0400A-7 R8i
600 600 527 900 56 450 395 510 448 74 10.6 2200 BDCL-15-7 0600A-7 R8i
800 800 703 1200 75 600 527 680 597 76 12.8 4400 2xBDCL-14-7 0800A-7 2xR8i
1200 1200 1054 1800 113 899 790 1020 895 76 21.5 4400 2xBDCL-15-7 1200A-7 2xR8i
Dimensions
Frame size Height 1) Width Depth Weight
(mm) (mm) ( mm) (kg)
R8i 2145 800 636 650
R8i 2145 800 636 680
2xR8i 2145 1600 636 1300
2xR8i 2145 1600 636 1360
3xR8i 2145 2400 636 2040
4xR8i 2145 3200 636 2720
5xR8i 2145 4000 636 3400
1)
2315 mm for IP54, and 2051 mm for IPXXR
No overload use
I dc input Maximum continuous input DC current from DC bus
I rms output Maximum continuous output current to/from energy storage
PN Maximum continuous output power to/from energy storage
I max output Maximum instantaneous output current to/from energy storage
I p2p Maximum output ripple current to/from energy storage
Light/heavy overload cycle
I short time Continuous output current allowing 10 s of I max (DC) every 60 seconds
Pshort time Continuous output power allowing 10 s of I max (DC) every 60 seconds
I Hd Continuous output current allowing overload of 150% I hd for 1 min every 5 min
P Hd Continuous output power allowing 150% I hd for 1 min every 5 min
A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G 51
—
Du/dt filters
Du/dt filtering suppresses inverter output If the motor does not meet the following
voltage spikes and rapid voltage changes that requirements, the lifetime of the motor might
stress motor insulation. Additionally, du/dt decrease. Insulated N-end (non-driven end)
filtering reduces capacitive leakage currents and bearings and/or common mode filters are also
high-frequency emissions from the motor cable, required for motor bearing currents with motors
as well as high-frequency losses and bearing bigger than 100 kW. For more information,
currents in the motor. The need for du/dt filtering please see the ACS880 hardware manuals.
depends on the motor insulation. For information
on the construction of the motor insulation, Please see below for information about how to
consult the manufacturer. select a filter according to the motor.
External du/dt filter for ACS880-104 Dimensions and weights of the du/dt filters
ACS880-104 Height Width Depth Weight
du/dt filter (mm) (mm) (mm) (kg)
BOCH-0350A-7
NOCH0030-60
NOCH0070-60
NOCH0016-60
500 V
690 V
—
All parallel connected ACS880-104 modules in frame size NOCH0016-60
nxR8i and all 690V ACS880-104 modules in frame size 1xR8i
and nxR8i have du/dt filters built-in as standard (+E205).
Built-in du/dt filters are available as option (+E205) for
ACS880-104 modules in frame size 1xR8i ranging from
380 to 500 V. The built-in du/dt filters in R8i modules
do not impact the module dimensions.
A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G 53
—
ACS880 drives are compatible with the
wide ABB product offering
—
Services to match your needs
Is rapid response
a key consideration?
If your drives require immediate action,
Is uptime your priority? our global network is at your service.
Rapid response
Operational efficiency
A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G 55
—
Drives service
Your choice, your future
The future of your drives depends on Your choice, your business efficiency
the service you choose. ABB Drive Care agreement lets you focus on your
Whatever you choose, it should be a well- core business. A selection of predefined service
informed decision. No guesswork. We have the options matching your needs provides optimal,
expertise and experience to help you find and more reliable performance, extended drive
implement the right service for your drive lifetime and improved cost control. So you can
equipment. You can start by asking yourself reduce the risk of unplanned downtime and find
these two critical questions: it easier to budget for maintenance.
• Why should my drive be serviced?
• What would my optimal service options be? We can help you more by knowing where you are!
Register your drive at www.abb.com/drivereg for
From here, you have our guidance and full extended warranty options and other benefits.
support along the course you take, throughout
the entire lifetime of your drives. Option code Description
+P904 Extension of warranty to 24 months from
commissioning or 30 months from delivery
+P909 Extension of warranty to 36 months from
commissioning or 42 months from delivery
Need to extend your
assets’ lifetime?
Maximize your drive’s lifetime Is performance most
with our services.
critical to your operation?
Example services include:
Get optimal performance out of your machinery
• ABB Ability Life Cycle Assessment
and systems.
• Upgrades, Retrofits and Modernization
• Replacement, Disposal and Recycling
Example services include:
• ABB Ability Remote Services
• Engineering and Consulting
• Inspection and Diagnostics
• Upgrades, Retrofits and Modernization
• Workshop Repair
• Tailored services
Performance improvement
56 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
A lifetime of peak performance
Full range of life cycle services and support Limited range of life cycle Replacement and
services and support end-of-life services
Full range of life cycle Full range of life cycle Limited range of life Replacement and
services is available. services is available. cycle services is end-of-life services
Services
—
Summary of features and options
Ordering ACS880- ACS880- ACS880- ACS880- ACS880- ACS880- ACS880-
code 107 207 307 307 907 607 brake 1607
INU ISU nxR8i DSU DSU RRU nxR8i unit DC-DC
R1i to D6D to D7T and nxR8i converter
nxR8i D8D nxD8T nxR8i
6-pulse 6/12-pulse
Mounting
Free-standing
Cabling
Supply bottom entry – – –
Supply top entry – – –
Inverter bottom exit – – – –
Inverter top exit – – – –
Degree of protection
IP22 (UL type 1)
1) 1)
IP42 (UL type 1)
1) 1)
IP54 (UL type 12)
Motor control
DTC motor control – – – – – –
Control panel
2) 2)
Intuitive control panel
EMC filters
EMC 1st environment, restricted
+E202 – – 4)
– –
distribution, C2, grounded network (TN)
EMC 2nd environment, C3, grounded (TN)
+E210 5) 5) 5) 5) 5) 5) 5)
and ungrounded network (IT)
Line filter
AC or DC choke – – – – –
LCL – – – – – –
L – – – – – –
Output filter
Common mode filter +E208 6) 6)
– – 6)
– –
Du/dt filters +E205 7)
– – – –
Braking (see braking unit table)
Incoming unit apparatus
Disconnector – 8) 9) 10)
– –
Air circuit breaker +F255 – 11) 9) 12)
– –
Line contactor +F250 – 8)
– 10)
– –
Earthing switch +F259 – – –
Inverter units
DC switch +F286 13)
– – – – 14)
two groups
2)
2 pcs digital inputs/outputs
2)
1 pcs digital input interlock
2)
3 pcs relay outputs programmable
2)
Drive-to-drive link/Built-in Modbus
2)
Assistant control panel/PC tool connection
Possibility for external power supply
for control unit
Built-in I/O extension and speed feedback
modules: for more details see sections:
“Input/output extension modules”, “Speed
feedback interfaces for precise process
control” and “DDCS communication option
modules” 18)
Built-in adapters for several fieldbuses:
for more details see section “Fieldbus
adapter modules” 19)
Standard
Selectable option, with plus code
Selectable option, external, no plus code
– Not available
1)
Not available for resistor D151
2)
Not available for 1-phase brake unit
3)
Pending.
4)
Available only as 6-pulse D8T
5)
Conducted emission and immunity are fulfilled with standard filtering. Radiated emission and immunity are as option (cabinet construction).
6)
Standard for frame sizes R6i to 10×R8i
7)
Optional in frame sizes R1i to R8i and 400/500 V
8)
For ISU: 400 to 500 V disconnector and contactor up to 2×R8i, 690 V disconnector and contactor up to 3×R8i.
For bigger ISU frames: air-circuit breaker.
9)
For DSU 6-pulse, 400/500 V: disconnector up to 3×D8T, air-circuit breaker ≥ 4×D8T.
For DSU 6-pulse, 690 V: disconnector up to 4×D8T, air-circuit breaker ≥ 5×D8T.
For DSU 12-pulse: All 12-pulse DSUs have disconnector as standard, air-circuit breaker is offered as an option.
10)
For RRU: Disconnector and contactor up to 2xR8i, air-circuit breaker ≥ 4×R8i.
11)
For ISU: 400 to 500 V air circuit breaker ≥ 3×R8i, 690 V air-circuit breaker ≥ 4×R8i
12)
For RRU: air circuit breaker >4xR8i
13)
R1i to R4i for cabinet, individual for R6i to n×R8i. Common for cabinet for R1i to R5i, individual for R6i to n×R8i.
14)
DC switch for 3-phase dynamic brake unit only
15)
EAC has replaced GOST R
16)
ACS880 marine type approval and type approved drives are listed at https://new.abb.com/drives/segments/marine/marine-type-approvals.
17)
Marine type approval only available for frames R5i-nxR8i
18)
Three option slots are available for I/O extension, speed feedback, fieldbus and functional safety options.
The slot number for I/O and encoder options can be extended with FEA-03 option.
19)
Three option slots are available for I/O extension, speed feedback, fieldbus and functional safety options.
Two different fieldbus connections are supported simultaneously.
62 A B B I N D U S T R I A L D R I V E S , A C S 8 8 0 M U LT I D R I V E S , C ATA LO G
—
Notes
63
Additional information
We reserve the right to make technical
changes or modify the contents of this
document without prior notice. With
regard to purchase orders, the agreed
particulars shall prevail. ABB does not
accept any responsibility whatsoever for
potential errors or possible lack of infor-
mation in this document.
abb.com/ACS880
abb.com/drives
abb.com/drivespartners
abb.com/motors&generators
Video playlist: