The document outlines the Mechanical Bill of Quantities (BOQ) for the Fire Fighting systems at the Kemit Industrial Complex, detailing specifications for various firefighting equipment and installations. It includes descriptions of items such as underground piping, valves, fire hose systems, extinguishing systems, and associated electrical work. The document is intended for the client, Kemit, and is dated January 2025.

Uploaded by

Sabry Mansour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views11 pages

FF

The document outlines the Mechanical Bill of Quantities (BOQ) for the Fire Fighting systems at the Kemit Industrial Complex, detailing specifications for various firefighting equipment and installations. It includes descriptions of items such as underground piping, valves, fire hose systems, extinguishing systems, and associated electrical work. The document is intended for the client, Kemit, and is dated January 2025.

Uploaded by

Sabry Mansour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 11

‫المجموعة للتصميم وإدارة المشروعات‬

‫مجموعة مصر المتحدة للصناعات الوطنية ‪ -‬كيميت‬

‫مجمع كيميت للصناعات‬

‫)‪Mechanical BOQ (Fire Fighting‬‬


‫‪JAN 2025‬‬
‫)‪REV (00‬‬

‫‪CONSULTANT‬‬

‫)‪DMG (DESIGN&PROJECT MANGMENT GROUP‬‬


95A, AL MARGHANY ST, MASR EL GDIDA.
TEL-FAX / +20 2690 6118 EMAIL: [email protected]
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

211200 Item 1 Underground Firefighting Piping


211313
Supply, install, connecting, testing, and commissioning
of all HDPE PE100 PN16 Piping system for water
sypply system underground network, The item shall
include excavation, back filling, sand
bedding,protection, thrust supports for all fittings as per
Specifications and drawings.

50 mm Dia. m 30
65 mm Dia. m 600
100 mm Dia. m 45
150 mm Dia. m 60
200 mm Dia. m 2400

211200 Individual Valves, Instruments & Guages


210523

Supply, install, connecting, testing, and commissioning


of the following valves, instruments and guages to be
installed on risers or branches including fittings,
connection to fire alarm or BMS systems, c/w with all
required accessories to meet NFPA requirements and
as per specifications and drawings.

1- Air Valve

80 mm Dia. nr 1

2- Washout valve

100 mm Dia. nr 1

Cairo - Egypt E-mail:[email protected]


Page 3 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

To Collection :

Cairo - Egypt E-mail:[email protected]


Page 4 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

Fire Standpipe and Hose System

211200 Fire Hose Station (Class III)

Supply, install, connecting, testing, and commissioning


of cabinet consisting of 65 mm diam. fire department
landing valves,65mm fire hose 30m long and 40mm
brass angle valve, fire hose reel,40mm fire hose 30m
long, nozzle steel cabinet, 6kg portable fire
extinguisher (dry powder), 6kg portable carbon dioxide
fire extinguisher (co2),pressure restricting type with
100 PSI down stream pressure having connections
complying with fire brigade requirements to meet
NFPA requirements and as per specifications and
drawings.

FHC-03 nr 45

211200 Fire Department Connection (Siamese)

Supply, install, connecting, testing, and commissioning


of fire department connection (Siamese or fire brigade)
200x65x65mm inlets c/w gate valve, check valve all
nr 1
necessary accessories required for the installation to
meet NFPA requirements and as per specifications and
drawings.

Fire Search

Supply, install, connecting, testing, and commissioning


of fire search for main electrical panels as per item LS
specifications and drawings.

Cairo - Egypt E-mail:[email protected]


Page 5 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

To Collection :

212113 Carbon Dioxide Extinguishing System

Supply, install, connecting, testing, and commissioning


of CO2 total flooding automatic fire extinguishing
system complete including cylinders, manifolds,
nozzles, piping work, detectors, alarm horns, flashing
devices, abort switches, batteries, enunciators, manual
pull stations and control cabinets. Magnetic retaining
and release device or electrical interlock to cause the
door operator to drive the door closed, connected to
main alarm control panle
Installation to meet NFPA requirements and as per
specifications and drawings.

RMU rooms item 2


Generator room (Except fuel tank) item 1
MDB room item 1
Transformer rooms item 2

212200 FM-200 Extinguishing System

Cairo - Egypt E-mail:[email protected]


Page 6 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

Supply, install, connecting, testing, and commissioning


of total flooding Extinguishing system of 7 percent
concentration by volume of C3HF7
heptafluoropropance HFC-227 ea (FM-200) standard in
maximum ten seconds, system shall be complete
including Indoor, vertical and cylinders metal tanks
with covers, manifolds, control panel nozzles, piping
work, detectors, alarm horns, switches and enunciators,
Magnetic retaining and release device or electrical
interlock to cause the door operator to drive the door
closed, connected to main alarm control panle
Installation to meet NFPA requirements and as per
specifications and drawings.

Distributor room item 1

To Collection :

211339 Foam Extinguishing System

Supply, install, connecting, testing, and commissioning


of foam system with concentration of 3%, the system
shall be complete including bladder tanks, proportional
valves, dry valves, pipings,manuall hose, control panel,
nozzels,detectors, alarm horns, switches and
announciators, Installation to meet NFPA requirements
and as per specifications and drawings.

Generator fuel tank item 1

211200 Outside Network Valve Box


210523

Cairo - Egypt E-mail:[email protected]


Page 7 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section
Construction, connecting and testing of firefighting
network valve box complete with approved type of
cover, frame, connections including excavation,
backfilling, concrete work, and valves as per
specifications and drawings.

VB-01 200 mm Dia nr 9


VB-02 150 mm Dia nr 6

210513 Electrical Work

Supply, install, commission, all the electrical


connection needed to operate the mechanical
equipment’s,. Including all glands, accessories, and
item LS
fixation frames. The connections to be terminated using
the proper accessories in the both the entrance/leaving
of the panel and mechanical equipment.

To Collection :

210517 BUILDER’S WORK:

The contractor will provide builder's work as required


by the Fire Protection Systems including, but not
limited to, the following: holes, mortices, chases and
the like required in the structure and for all necessary
sleeves, anchors. base plates, isolation packing, holding item LS
down bolts, grouting, concrete pads except included in
concrete section, painting, and structural steel, supports
in accordance with specifications in respect to all Fire
Protection installations

Cairo - Egypt E-mail:[email protected]


Page 8 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

To Collection :

Cairo - Egypt E-mail:[email protected]


Page 9 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

Page 1 .................... L.E


Page 2 .................... L.E
Page 3 .................... L.E
Page 4 .................... L.E
Page 5 .................... L.E

TOTAL OF MECHANICAL WORKS....................L.E

....................................................................................

CONTRACTOR SIGNATURE: -
……………….

Cairo - Egypt E-mail:[email protected]


Page 10 Website:www.dmg-eg.com
‫المجموعة للتصميم وإدارة المشروعات‬

Client ‫ كيميت‬- ‫مجموعة مصر المتحدة للصناعات الوطنية‬ Date 01/2025


Project ‫مجمع كيميت للصناعات‬ Rev 00

Mechanical BOQ (Fire Fighting)


Specs
Item Description Unit Oty Price Total
Section

Cairo - Egypt E-mail:[email protected]


Page 11 Website:www.dmg-eg.com