PVsyst - Simulation report
Grid-Connected System
Project: demo1
Variant: New simulation variant
No 3D scene defined, no shadings
System power: 3120 Wp
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Project summary
Geographical Site Situation Project settings
Bhubaneswar Latitude 20.26 °N Albedo 0.20
India Longitude 85.86 °E
Altitude 15 m
Time zone UTC+5.5
Weather data
Bhubaneswar
Meteonorm 8.2 (2001-2020), Sat=100% - Synthetic
System summary
PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings
Simulation for year no 10
System information
PV Array Inverters
Nb. of modules 6 units Nb. of units 1 unit
Pnom total 3120 Wp Pnom total 3000 W
Pnom ratio 1.040
Results summary
Produced Energy 3769.8 kWh/year Specific production 1208 kWh/kWp/year Perf. Ratio PR 75.51 %
PVsyst TRIAL
Project and results summary
General parameters, PV Array Characteristics, System losses
Main results
Loss diagram
Table of contents
2
3
5
6
Predef. graphs 7
Single-line diagram 11
Cost of the system 12
CO₂ Emission Balance 13
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 2/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Array Characteristics
PVsyst TRIAL
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model WSMD-520 Model 3 kWac inverter
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 520 Wp Unit Nom. Power 3.00 kWac
Number of PV modules 6 units Number of inverters 1 unit
Nominal (STC) 3120 Wp Total power 3.0 kWac
Modules 1 strings x 6 In series Operating voltage 125-440 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.04
Pmpp 2853 Wp
U mpp 221 V
I mpp 13 A
PVsyst TRIAL
Total
Module area
DC wiring losses
Global array res.
Array losses
Number of inverters
Pnom ratio
284 mΩ
Serie Diode Loss
Voltage drop
1 unit
1.04
0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 0.3 % at STC
Uv (wind) 0.0 W/m²K/m/s
LID - Light Induced Degradation Module Quality Loss Module mismatch losses
Loss Fraction 2.0 % Loss Fraction -0.5 % Loss Fraction 2.0 % at MPP
PVsyst TRIAL
Loss factor 0.4 %/year
Imp / Vmp contributions 80% / 20%
Mismatch due to degradation
Imp RMS dispersion 0.4 %/year
Vmp RMS dispersion 0.4 %/year
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 3/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Array losses
Spectral correction
FirstSolar model
Precipitable water estimated from relative humidity
Coefficient Set C0 C1 C2 C3 C4 C5
Monocrystalline Si 0.85914 -0.02088 -0.0058853 0.12029 0.026814 -0.001781
System losses
Unavailability of the system
PVsyst TRIAL
Time fraction 2.0 %
7.3 days,
3 periods
AC wiring losses
Inv. output line up to injection point
Inverter voltage 230 Vac mono
Loss Fraction 0.54 % at STC
Inverter: 3 kWac inverter
Wire section (1 Inv.) Copper 1 x 2 x 4 mm²
Wires length 10 m
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 4/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Main results
System Production
Produced Energy 3769.8 kWh/year Specific production 1208 kWh/kWp/year
Perf. Ratio PR 75.51 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
February 122.4 65.09 25.00 140.6 138.4 351.9 339.0 0.773
March 154.6 81.21 28.57 159.8 156.9 391.4 376.7 0.756
April 167.5 89.25 30.31 155.9 152.5 379.9 329.2 0.677
May 173.0 98.07 31.84 146.9 142.8 356.8 343.2 0.749
June 127.9 93.53 29.93 107.9 104.6 267.9 256.9 0.763
July 122.0 86.11 28.72 103.2 100.0 257.8 246.9 0.767
August 123.5 85.91 28.22 110.4 107.4 276.9 265.7 0.771
September 123.8 75.02 27.65 120.3 117.5 299.9 249.6 0.665
October 123.5 79.39 27.19 132.5 129.8 333.3 320.8 0.776
November 114.8 64.31 23.98 137.4 135.1 349.5 336.5 0.785
December 109.0 58.47 21.39 139.1 137.1 357.5 344.3 0.793
Year 1578.6 939.26 27.02 1600.1 1565.8 3997.4 3769.8 0.755
PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 5/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Loss diagram
1579 kWh/m² Global horizontal irradiation
+1.4% Global incident in coll. plane
PVsyst TRIAL
-3.8% Module Degradation Loss ( for year #10)
PVsyst TRIAL
3997.4 kWh Array virtual energy at MPP
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 6/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Predef. graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 7/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Predef. graphs
Array Power Distribution
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 8/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Predef. graphs
System Output Power cumulative distribution
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 9/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Predef. graphs
Array Temperature Distribution during running
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 10/13
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
Operating costs
Item Total
PVsyst TRIAL
EUR/year
Total (OPEX) 0.00
System summary
Total installation cost 0.00 EUR
Operating costs 0.00 EUR/year
Produced Energy 4136 kWh/year
Cost of produced energy (LCOE) 0.0000 EUR/kWh
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 12/13
Project: demo1
Variant: New simulation variant
PVsyst V8.0.5
VC0, Simulation date:
22/12/24 20:52
PVsyst TRIAL
with V8.0.5
PVsyst TRIAL
Annual degradation: 1.0 %
PVsyst TRIAL
Inverters 619 kgCO2/ 1.00 619
PVsyst TRIAL
PVsyst TRIAL
22/12/24 PVsyst Evaluation mode Page 13/13