0% found this document useful (0 votes)
3 views

LEOCH-DJM265

The LPG12-65 is a 12V65Ah gel battery designed for various applications including telecommunications, solar systems, and engine starting. It features a robust design with a long life expectancy of 12 years at 25°C, efficient gas recombination, and is resistant to deep discharge. The battery is certified to IEC60896 standards and is manufactured in compliance with multiple quality management systems.

Uploaded by

Arass Hasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

LEOCH-DJM265

The LPG12-65 is a 12V65Ah gel battery designed for various applications including telecommunications, solar systems, and engine starting. It features a robust design with a long life expectancy of 12 years at 25°C, efficient gas recombination, and is resistant to deep discharge. The battery is certified to IEC60896 standards and is manufactured in compliance with multiple quality management systems.

Uploaded by

Arass Hasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

LPG SERIES-GEL BATTERY

P-TITLE (12V65Ah)
LPG12-65

CHARACTERISTICS
Item Specifications
Rated Voltage P-RV
12V
Nominal Capacity (25℃) C20,1.80V/cell P-2080
65Ah
Length 325mm P-LENGTH
(12.8inches)
Width P-WIDTH
167mm (6.57inches)
Dimension
Container Height P-HEIGHT
174mm (6.85inches)
Total Height 174mm P-THEIGHT
(6.85inches)
Approx Weight P-GWEIGHT
20.5kg (45.2lbs)
Terminal P-TER
T6(M6)
Container Material ABS (UL94 HB or V-0 optional)
Short-circuit current P-SC
1365A
Internal Resistance (25℃) ApproxP-IR
9.4 mΩ (Fully charged)
Discharge -20~60℃ (-4~140°F)
Operating Temp. Range Charge -20~40℃ (-4~104°F)
Storage -20~50℃ (-4~122°F)
Nominal Operating Temp. Range 25±3℃ (77±5°F)
Max.Charging Current (25℃) 0.25C
174±2

Standby Use Cycle Use


165±2

Charge voltage (25℃)


2.23-2.27V/cell 2.35-2.40V/cell
Temp. Coeffcient -3mV/cell/℃ -5mV/cell/℃
40℃ (104°F) 103%
Ø16
Effect of temp. to Capacity 25℃ (77°F) 100%
0℃ (32°F) 86%
6

≤2.5% per month at 25°C (77°F).


167±2

M6
LPG series batteries may be stored up to
59.5±1

9 months at 25°C (77°F) and then a


Self Discharge
freshening charge is required.
T6
For higher temperatures the time interval
262±2
will be shorter.
325±2

DISCHARGE TABLE
Constant Current Discharge (Amperes) at 25°C (77°F)
F.V/Time 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h
P-A85
1.85V/cell A8510m
79.0 A8515m
68.5 A8520m
53.8 A8530m
48.7 A8545m
35.6 A851
28.2 A8515
21.9 A852
17.4 A853
13.8 A854
11.3 A855
9.78 A856
8.56 A858
6.94 A8510
5.88 A8520
3.04
P-A80
1.80V/cell A8010m
89.6 A8015m
77.6 A8020m
60.9 A8030m
53.0 A8045m
37.7 A801
31.2 A8015
23.2 A802
19.2 A803
15.2 A804
12.2 A805
10.3 A806
9.05 A808
7.24 A8010
6.00 A8020
3.25
P-A75
1.75V/cell A7510m
97.2 A7515m
84.0 A7520m
65.7 A7530m
54.1 A7545m
39.1 A751
35.0 A7515
25.4 A752
20.6 A753
15.8 A754
12.6 A755
10.6 A756
9.37 A758
7.35 A7510
6.18 A7520
3.27
P-A70
1.70V/cell A7010m
101.7 A7015m
88.2 A7020m
69.2 A7030m
54.5 A7045m
39.7 A701
36.1 A7015
26.0 A702
21.0 A703
16.1 A704
12.6 A705
10.7 A706
9.37 A708
7.42 A7010
6.18 A7020
3.32
P-A67
1.67V/cell A6710m
106.9 A6715m
91.8 A6720m
71.6 A6730m
56.0 A6745m
40.5 A671
36.8 A6715
26.5 A672
21.4 A673
16.3 A674
12.8 A675
10.9 A676
9.50 A678
7.48 A6710
6.24 A6720
3.35
P-A60
1.60V/cell A6010m
110.6 A6015m
94.7 A6020m
73.4 A6030m
56.8 A6045m
41.1 A601
38.0 A6015
27.3 A602
21.9 A603
16.5 A604
13.1 A605
11.2 A606
9.65 A608
7.54 A6010
6.30 A6020
3.39

Constant Power Discharge (Watts/cell) at 25°C (77°F)


F.V/Time 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h
P-B85
1.85V/cell B8510m
148.5 B8515m
129.6 B8520m
102.4 B8530m
93.1 B8545m
68.5 B851
54.8 B8515
42.6 B852
34.1 B853
27.1 B854
22.2 B855
19.3 B856
16.9 B858
13.7 B8510
11.7 B8520
6.05
P-B80
1.80V/cell B8010m
166.2 B8015m
145.0 B8020m
114.5 B8030m
100.5 B8045m
72.1 B801
60.2 B8015
44.9 B802
37.3 B803
29.7 B804
23.9 B805
20.2 B806
17.8 B808
14.3 B8010
11.9 B8020
6.46
P-B75
1.75V/cell B7510m
177.3 B7515m
154.8 B7520m
122.3 B7530m
101.8 B7545m
74.2 B751
67.1 B7515
48.9 B752
39.8 B753
30.7 B754
24.6 B755
20.8 B756
18.4 B758
14.5 B7510
12.2 B7520
6.50
P-B70
1.70V/cell B7010m
182.3 B7015m
160.3 B7020m
127.1 B7030m
101.5 B7045m
74.8 B701
68.6 B7015
49.7 B702
40.4 B703
31.1 B704
24.6 B705
21.0 B706
18.4 B708
14.6 B7010
12.2 B7020
6.58
P-B67
1.67V/cell B6710m
189.5 B6715m
165.3 B6720m
130.6 B6730m
103.7 B6745m
75.9 B671
69.7 B6715
50.6 B672
41.1 B673
31.5 B674
24.9 B675
21.3 B676
18.6 B678
14.7 B6710
12.3 B6720
6.63
P-B60
1.60V/cell B6010m
192.1 B6015m
167.6 B6020m
132.4 B6030m
104.1 B6045m
76.3 B601
71.3 B6015
51.5 B602
41.6 B603
31.7 B604
25.2 B605
21.6 B606
18.8 B608
14.7 B6010
12.4 B6020
6.71
LPG SERIES-GEL BATTERY
P-TITLE (12V65Ah)
LPG12-65

APPLICATIONS GENERAL FEATURES STANDARDS

• Telecommunications • 12 years design life (25℃) • IEC60896 Certified


• Solar system • Gelled electrolyte for superior thermal • Classified as"Long Life"
management, long float life according to Eurobat
• Wind power system
• Efficient gas recombination decreases
• Engine starting gassing/water and extends battery life • UL,CE Approved

• Robust design - resilient in harsh conditions • Manufactured in Leoch®IATF16949,


• Wheelchair, Floor cleaning machines, ISO 45001,ISO 9001 and ISO 14001
Golf trolley, Boats • Proof against deep discharge - greater certified production facilities
long-term energy delivery and cycle life

Discharge Characteristics Charging Characteristics


Charge Charging Charging
Temperature:25℃ Volume Current Voltage

(V/cell)
(%) (XCA) (V/cell) 0.15CA-2.35V/cell Temperature: 25℃
2.17

2.00 0.15
120 Charged Volume
2.45
Voltage(V/cell)

1.83 100 0.12


10HR 20HR 2.40
1.67 3HR Charge Voltage
80
0.09
0.25HR 0.5HR 1HR 2.30
1.50 60
0.06
40 2.00 After 50% Discharge
1.33
After 100% Discharge
0.03
20
1.83 Charging Current
1 2 4 6 10 20 40 60 2 3 5 10 20 30
0 0 0
Min H 0 2 4 6 8 10 12 14 16 18 20

Discharge Time
Charging Time (hours)

Cycle Life in Relation to DoD Self Discharge Characteristics

120

100
Available capacity / %
DoD(%)

80
10℃
60
20℃
40℃ 30℃

40

20

0 5 10 15 20 25
0

Number of Cycles Storage time (months)

Leoch International Technology Ltd. Leoch Batteries Pte Ltd Leoch Battery Corporation Leoch Europe S.A.
www.leoch.com www.leoch.sg www.leochamericas.com www.leoch.eu

Data above is recommended and the picture is only for battery effect display, Leoch reserve the final right of explanation.
© LEOCH. All rights reserved.Trademarks and logos are the property of LEOCH and its affiliates unless otherwise
noted.Subject to revisions without prior notice. E&OE. P-VERSION
Publication No.:LB-LPG12-65-PD-EN-V2.0-20240109

You might also like