lify-single-core
lify-single-core
APPLICATION STANDARDS
The LifY single cores are used as highly flexible insulated DIN VDE 0250, DIN VDE 0285-525-1 / DIN EN 50525-1
strand wires for switch cabinets, and as measuring cable PVC self-extinguishing and flame retardant acc. to DIN VDE
for testing, laboratories and research. 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
Test Voltage
up to 0.25 mm²: 2 kV
0.5-1 mm²: 2.5 kV
from 1.5 mm²: 3 kV SUSTAINABILITY COMMITMENT
Temperature Rating We are on a journey to Net Zero.
Flexing: -15°C to +80°C We've committed to near-term emissions reductions and a net-zero target with the
Science Based Targets initiative and we're a signatory to the United Nations Global
Compact Sustainable Development Goals.
Minimum Bending Radius
Flexing: 8 x overall diameter Learn more about embodied carbon and our carbon emissions reduction actions,
our comprehensive recycling services, and wider ESG activities for sustainable
operations at: www.elandcables.com/company/about-us/esg-sustainability
CONSTRUCTION
Conductor
Bare copper extra fine wire conductor
This cable meets the requirements of the Low Voltage Directive 2014/35/EU,
the RoHS Directive 2015/65/EU and Reach Directive EC 1907/2006. RoHS
compliance has been tested and confirmed by The Cable Lab®.
DIMENSIONS
ELAND PART NO. NO. OF NOMINAL CROSS APPROXIMATE NOMINAL OVERALL NOMINAL
CORES SECTIONAL AREA AWG DIAMETER WEIGHT
mm2 mm kg/km
COLOUR CODES
Trans- Dark Green/ Orange
COLOUR Black Green Blue Beige Grey Red Pink Yellow Violet Brown White
parent Blue Yellow
CODE BK GN BL BE TR DKBL GR GY OR RD PK YW VI BR WH