12 - Alarm Test Program

The document outlines an alarm test program for a shipping vessel, detailing various alarms, their testing frequencies, and procedures. Each alarm is associated with specific conditions that trigger notifications, such as low pressure or high temperature. It emphasizes that the values for alarm activations are indicative and that any missing alarms should be reported to the company.

Uploaded by

vazhachkimikocha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views

12 - Alarm Test Program

The document outlines an alarm test program for a shipping vessel, detailing various alarms, their testing frequencies, and procedures. Each alarm is associated with specific conditions that trigger notifications, such as low pressure or high temperature. It emphasizes that the values for alarm activations are indicative and that any missing alarms should be reported to the company.

Uploaded by

vazhachkimikocha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

Platin SAFETY MANAGEMENT MANUAL FORM NO

SHIPPING AND TRADING CO.LTD DATE


10/1/2010
REVISION 0 PAGE 1
12
ALARM TEST PROGRAM

M/V ……………………………………………

No. ALARM LIST FREQUENCY


ALARM TEST AND PROCEDURE REMARKS
7 30 90 180
1 FO PURIFIER FAULT X OVER FLOW WILL SOUND ALARM
2 GO PURIFIER FAULT X OVER FLOW WILL SOUND ALARM
3 LO NO.1 PURIFIER FAULT X OVER FLOW WILL SOUND ALARM
4 LO NO.2 PURIFIER FAULT X OVER FLOW WILL SOUND ALARM
5 EVAPORATOR F.W. HIGH SALINITY X 1.2 ppm START ALARM
6 CO2 RELEASE BOX X WHEN OPEN THE CO2 DOOR
7 OIL MIST DETECTOR FAULT X 8 TO 10 Mil.AMP. SOUND ALARM
8 STEERING GEAR SUPPLY X PHASE FAULT SOUND ALARM
9 STEERING GEAR DAILY LO TK.,LOW LEVEL X MINIMUM LEVEL 60 Lt. SOUND ALARM
10 ENGINE BILGE FWD/STBD EXTREMALY HIGH X TEST TO PULL UP FLOATING BULB
11 LEVEL
A/E NO.1/ 2 / 3 LO LOW PRESSURE X 2.2 Kg/cm2 ALARM SOUND WHEN STOP THE ENGINE
12 A/E NO.1/ 2 / 3 LO HIGH TEMPERATURE X 85 C TO REMOVE THERMOCOUPLE AND TO HEAT
13 A/E NO.1 / 2 /3 FW LOW PRESSURE X 1.8 WHEN STOP F.W. PUMP
14 A/E NO.1/2/3 FW HIGH TEMPERATURE X 85 TO REMOVE TERMOCOUPLE AND TO HEAT
15 A/E FUEL OIL PRESSURE X 1.5 ALARM SOUND WHEN PUMP STOP
16 A/E S.W. LOW PRESSURE X 1.0 WHEN S,W. PUMP STOP
17 A/E STARTING AIR LOW PRESSURE X 12.5 Kg. WHEN DRAINING AIR AT 15 Kg SOUND ALARM
18 A/E AUTOMATIC STAND BY START FAULT X CLOSE AIR TO THE AUTOMATIC CONTROLL MONITORING SOUND ALARM
19 BATTARY CHARGER FAULT X WHEN SWITCH OFF BATTERY CHARGER SOUND ALARM
20 LOW FREQUENCY X - 3.5 Hz WHEN STOP A/E OR ADJUST FREQUENCY BY HAND SOUND ALARM
21 A/E NO.1/2/3 GRAVITY TANK LOW LEVEL X 50 Lt MINIMUM LEVEL SOUND ALARM OR DISCONNECT ONE PHASE SOUND ALARM
22 M/E SUMP TANK LOW LEVEL X 47 cm MINIMUM LEVEL SOUND ALARM
23 M/E CYLINDERS OIL TANK LOW LEVEL X 500 Lt MINIMUM LEVEL SOUND ALARM
24 M/E GRAVITY TANK LOW LEVEL X 152 Lt MINIMUM LEVEL SOUND ALARM
25 M/E INJECTORS GRAVITY TANK LOW LEVEL X 50 Lt MINIMUM LEVEL SOUND ALARM OR DISCONNECT ONE PHASE SOUND ALARM
26 M/E IFO DAILY TANK LOW LEVEL X 3 M3 MINIMUM LEVEL SOUND ALARM
27 GO DAILY TANK LOW LEVEL X 1,25 M+H59 MINIMUM LEVEL SOUND ALARM
28 IFO OVERFLOW TANK HIGH LEVEL X 4 M3 HIGH LEVEL SOUND ALARM
29 GO OVERFLOW TANK HIGH LEVEL X 4 M3 HIGH LEVEL SOUND ALARM
30 A/E NO.1/2/3 SUMP TANK LOW LEVEL X 400 Lt MINIMUM LEVEL SOUND ALARM
31 OIL SPILLAGE TANK HIGH LEVEL X 4,9 M3 HIGH LEVEL SOUND ALARM
32 SLUDGE TANK HIGH LEVEL X 9.2 M3 HIGH LEVEL SOUND ALARM
33 EMCY F/F PUMP FUEL TANK LOW LEVEL X 50 Lt MINIMUM LEVEL SOUND ALARM OR DISCONNECT ONE PHASE SOUND ALARM
34 STERN TUBE LO GRAVITY TANK LOW LEVEL X 50 Lt MINIMUM LEVEL SOUND ALARM OR DISCONNECT ONE PHASE SOUND ALARM
35 M/E LO LOW PRESSURE X 4.3 Kg/cm2 TEST TO CLOSE BY HAND REDUCTION VALVE
36 M/E LO FILTER HIGH PRESSURE, DIFFERENCE X 0.6 Kg/cm2 ALARM SOUND WHEN FILTER IS DIRTY OR TO DISCONNECT ONE PHASE
37 M/E CYLINDERS LOW LUBRICATION X 1.0 kG/cm 2 WHEN STOP M/E SOUND ALARM
38 M/E LO INLET TEMP. HIGH X 55 C REMOVE TERMOCOUPLE AND TO HEAT SOUND ALARM
39 M/E CYLINDER F.W. INLET LOW PRESSURE X 1.0 Kg/cm2 WHEN STOP FRESH WATER PUMP SOUND ALARM
40 M/E INJECTORS COOLING W. LOW PRESSURE X 1.0 Kg/cm 2 TEST TO OPEN BY PASS THAN START TO SOUND ALARM
41 M/E CYL. NO.1-6 COOLING W. HIGH X 90 C REMOVE TERMOCOUPLE AND TO HEAT START TO SOUND ALARM
42 TEMPERATURE
M/E FUEL INJECTORS COOL.W. HIGH TEMPERAT. X 95 C REMOVE TERMOCOUPLE AND TO HEAT START TO SOUND ALARM
43 M/E CYLINDER LOW LUBRICATION X 2.0 Kg/cm 2 WHEN STOP M/E SOUND ALARM
44 M/E SC. AIR COOLER S.W. LOW PRESSURE X 1.0 WHEN STOP SW. PUMP
45 M/E F.O. INLET LOW PRESSURE X 1.7 TO OPEN REDUCTION VALVE SOUND ALARM
46 M/E SC. AIR TEMPERATURE HIGH/LOW X 60/25 C STOP/OPEN SW. PUMP ALARM SOUND
47 M/E STARTING AIR LOW PRESSURE X 15 Kg. WHEN DRAINING AIR AT 15 Kg SOUND ALARM
48 M/E CONTROL AIR LOW PRESSURE X 4.3 Kg/cm2 TEST TO CLOSE BY HAND REDUCTION VALVE
49 M/E SLOW DOWN X STOP M/E SOUND ALARM
50 M/E F.O. SERVICE TANK HIGH TEMPERATURE X 80 C DISCONNECT PHASE SOUND ALARM
51 M/E F.O. SETTLING TANK HIGH TEMPERATURE X 80 C DISCONNECT PHASE SOUND ALARM
52 M/E PROPELLER SHAFT BEARING HIGH TEMP. X 60 C DISCONNECT PHASE SOUND ALARM
53 M/E REDUCTION GEAR LO LOW PRESSURE X 0.8 KG/cm2 WHEN OPEN REDUCTION VALVE SOUND ALARM
54 M/E REDUCTION GEAR BEARING HIGH TEMP. X 60 C DISCONNECT PHASE SOUND ALARM
55 M/E REDUCTION GEAR LO LOW LEVEL X 0,5 LTRS DISCONECT PHASE SOUND ALARM
56 STERN TUBE BEARING HIGH TEMPERATURE X 45 DISCONNECT PHASE SOUND ALARM
57 STAND BY ALL AUTOMATIC PUMPS START X AFTER STOP MAIN PUMPS START OTHER PUMP SOUND ALARM
58 MAIN AIR COMPRESSOR NO.1 - 2 FAULT X LOW PRESSURE LO START STAND BY COMPRESSOR SOUND ALARM
59 REDUC. AIR 7 BAR LOW PRESSURE X 6.5 KG/cm2 AFTER CLOSE REDUCTION AIR VALVE SOUND ALARM
60 BOILER STEAM HIGH/LOW PRESSURE X 3/1.5 Kg/cm2 WHEN CHANGE EXAUST BOILER SOUND ALARM
61 BOILER WATER SALINITY X 1.2 ppm START ALARM
62 BOILER FAULT X 1 Kc/cm2 NOT START SOUND ALARM
63 BOILER FEED WATER TANK LOW LEVEL X 100 LTRS DISCONECT PHASE SOUND ALARM
64 M/E EMERGENCY STOP X 4.3 Kg/cm2 MINIMUM PRESSURE M/E WILL STOP AND IF PUSH EMERGENCY STOP
65 GENERAL ALARM X PUSH BUTTON AND SHOW ALL ALARM
66 NAVIGATION LIGHTS FAULT before TAKE OUT A BULB FROM LIGHT CASING
67 GYRO/MAGNETIC COMPASS OFF COURSE depart.
before SET COURSE OUT OF ALARM RANGE
68 STEERING GEAR UNIT PUMPS depart.
before SWITCH OFF UNIT PUMP
69 INJECTOR FUEL PIPES LEAKAGE depart.
X AS PER MAKER INSTRUCTIONS
70 WATER INGRESS Bulk Carrier before AS PER MAKER INSTRUCTIONS
loading

NOTE: ALL VALUES CONCERNING ALARMS ACTIVATIONS ARE INDICATIVE ONLY. PLEASE REFER TO THE EQUIPMENT INSTALLED ON YOUR SHIP.
IF SOME ALARM MISSING INFORM THE COMPANY
Safety Management Manual
Revision
Alarm test program Date
Page

Form no.
ement Manual
0
0.065625
1 of 1

12