The MBB B0 105 Maintenance Manual outlines the electrical heating and ventilation system, detailing its operation, troubleshooting, and inspection procedures. The system provides cockpit air conditioning and cargo compartment heating, controlled via an overhead console switch. Troubleshooting steps and probable causes for various issues are provided to assist in maintenance and repairs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views19 pages

chapt_802

The MBB B0 105 Maintenance Manual outlines the electrical heating and ventilation system, detailing its operation, troubleshooting, and inspection procedures. The system provides cockpit air conditioning and cargo compartment heating, controlled via an overhead console switch. Troubleshooting steps and probable causes for various issues are provided to assist in maintenance and repairs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

MBB HELICOPTERS

MAINTENANCE MANUAL MBB .B0 105

802 ELECTRICAL HEATING AND VENTILATION SYSTEM 4kW/3+lkW

Table of Contents

Paragraph Title Page


802 .1 DESCRIPTION .ELECTRICAL HEATING AND VENTILATION
SYSTEM4kW/3+lkW ..................... 3
TROUBLESHOOTING .ELECTRICAL HEATING AND VENTILATION
SYSTEM 4kW/3+lkW ................. .... 4
INSPECTION SCHEDULE .ELECTRICAL HEATING AND VENTILATION
SYSTEM4kW/3+lkW ...................... 7
INSPECTION FOR CONDITION .ELECTRICAL HEATING AND VENTILATION
SYSTEM4kW/3+lkw ..................... 8
FUNCTIONAL CHECK .ELECTRICAL HEATING AND VENTILATION
SYSTEM 4kW/3+lkW ..................... 8
Removal .vent nozzles .................. 9

Removal .heating cartridge . . . . . . . . . . . . . . . . 10


Installation .heating cartridge ............. 11
Removal .axial fan . . . . . . . . . . . . . . . . . . . . 11
Installation .axial fan ................. 12
Replacement .carbon brushes (axial fan) ......... 12
Removal .control unit ................... 13
Installation .control unit ................ 13
Replacement .flexible hoses ............... 13
Removal .heater blower .................. 13
Installation .heater blower ............... 14
Removal .auxiliary control unit ............. 14
Installation .auxiliary control unit ........... 14

B0 105
CHAPTER 802
Page 112
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105

802 - 1 DESCRIPTION - ELECTRICAL HEATING AND VENTILATION SYSTEM 4kW/3+lkW

1. General

The system, c o n t r o l l e d through a switch mounted on t h e overhead.console,


provides cockpit a i r conditioning (4kW c o n f i g u r a t i o n ) and cargo
compartment h e a t i n g (3tlkW c o n f i g u r a t i o n ) ; p r e s e l e c t e d temperatures and
a i r supply a r e maintained a t a constant l e v e l . The h e a t i n g system
o p e r a t e s only when t h e engines a r e running o r an e x t e r n a l power u n i t i s
connected.
Description
The e l e c t r i c a l h e a t i n g and v e n t i l a t i o n system c o n s i s t s of heating,
c i r c u i t p r o t e c t i o n , and c o n t r o l components, t o g e t h e r with an a i r flow
d i s t r i b u t i o n system comprised of f l e x i b l e hoses ( s e e f i g . 802-1 and
802-2) .
3. Operation

NOTE I f t h e rescue h o i s t i s i n s t a l l e d , t h e h e a t i n g and


v e n t i l a t i o n system can only be operated with t h e
h o i s t master switch a t OFF.

a. Heating
S e t t i n g t h e overhead console-mounted switch BLOWER-OFF-HEATING 3HA t o
HEATING a c t i v a t e s t h e a x i a l fan 8HAI which s u p p l i e s t h e d i s t r i b u t i o n
system with e i t h e r f r e s h (outside) a i r o r cabin a i r , depending on t h e
p o s i t i o n of t h e a i r - i n t a k e l e v e r i n t h e ribbed Cover of t h e a i r
intake .
Turning t h e r o t a r y c o n t r o l knob TEMP CONT 5HA on t h e overhead console
clockwise a c t i v a t e s t h e c e n t r a l l y mounted IkW h e a t i n g c a r t r i d g e s 18HA
and 19HA through r e l a y 9HA, and t h e l a t e r a l l y mounted IkW heating
c a r t r i d g e s 20HA and 21HA i n t h e 4kW configuration, through r e l a y l O H A
( s e e f i g . 802-3) .
I n t h e 3tlkW configuration, t h e h e a t i n g c a r t r i d g e 20HA i n t h e 4kW
configuration i s replaced by a h e a t e r blower 22HA which i s c o n t r o l l e d
through t h e a u x i l i a r y c o n t r o l u n i t 31HA by t o g g l e switch CARGO COM
HEATING 30HA l o c a t e d on t h e overhead console. I n t h e ON p o s i t i o n ,
cargo compartment heating i s provided, t h e temperature of which
cannot be r e g u l a t e d ( s e e f i g . 802-4).
The lamps of t h e f o u r - l i g h t annunciator HEATING 7HA l o c a t e d i n t h e
bottom l e f t hand Corner of t h e overhead console, l i g h t up when t h e i r
r e s p e c t i v e h e a t i n g c a r t r i d g e i s energized.

B 0 105
CHAPTER 802
Page 3
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105

A l l t h e h e a t i n g c a r t r i d g e s a r e p r o t e c t e d a g a i n s t overheating (approx.
63 O C ) by thermal switches. Additional thermal switches i n t h e c e n t e r
heating c a r t r i d g e s i n t e r r u p t t h e power supply a s soon a s t h e a i r flow
temperature exceeds approx. 30 O C .

b. Ventilation
S e t t i n g t h e overhead console-mounted switch BLOWER-OFF-HEATING 3HA t o
BLOWER provides t h e a x i a l fan 8HA with power from t h e main bus PP21,
while c l o s i n g t h e power path t o t h e f o u r h e a t i n g c a r t r i d g e s i n t h e 4kW
configuration ( s e e f i g . 802-3) v i a blocking diodes l l H A and 12HA (See
f i g . 802-3).
With t h e two switch S e t t i n g s of t o g g l e switch CARGO COM HEATING 30HA,
t h e 3tlkW configuration can provide h e a t i n g of t h e cargo compartment.
I n p o s i t i o n ONI t h e h e a t e r blower 22HA o p e r a t e s i n conjunction with
t h e a x i a l fan. I n p o s i t i o n OFFI both cargo compartment heating and
v e n t i l a t i o n a r e shut down (see f i g . 802-4).

802 - 2 TROUBLESHOOTING - ELECTRICAL HEATING AND VENTILATION


SYSTEM 4kW13tlkW

General
- Perform troubleshooting with wiring diagrarns 802-1 and 802-2 i n t h e Wiring
Diagram Manual (WDM) .
- I£ rescue h o i s t i s i n s t a l l e d , s e t i t s master switch WINCH t o OFF.
- Check a l l a s s o c i a t e d switches and c i r c u i t breakers f o r unimpaired
mechanical function.
- Check t h a t a l l a s s o c i a t e d e l e c t r i c a l connections a r e t i g h t and secure.
- Troubleshoot using e i t h e r e x t e r n a l o r g e n e r a t o r power only.
- Depress a l l system c i r c u i t breakers:
On instrument panel: 1HA and 2HA
On overhead console: 13HA, 14HA, 15HAI 16HA and 17HA
- Functionally check a l l f o u r heating c a r t r i d g e s by momentarily p r e s s i n g t h e
f o u r - l i g h t annunciator 7HA i n t h e overhead console.

B 0 105
CHAPTER 802
Page 4
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B 0 105

No. TROUBLE SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION

1 Axial f a n 8HA Faulty a x i a l f a n Measure applied voltage.


inoperative i n Check f o r shorted c o i l .
p o s i t i o n BLOWER Replace a x i a l f a n a s
required
Faulty toggle switch Check p e r wiring
3HA o r w i r i n g / i n s u l a t i o n diagram. Repair a s
between c i r c u i t breaker required and replace
1HA and a x i a l f a n defective parts
2 Axial f a n 8HA Faulty a x i a l f a n See above
inoperative i n
p o s i t i o n HEATING Faulty toggle switch Check c o n t i n u i t y of
3HA switch and replace
i f necessary
Faulty c o n t r o l u n i t 19VE Check p e r wiring
diagram. Inspect
e l e c t r i c a l connections
and ground connections.
Replace c o n t r o l u n i t
a s required
Fauity temperature Check p e r wiring
control circuit diagram. Inspect
board 4HA e l e c t r i c a l connections.
Replace c i r c u i t board
a s required
Faulty temperature Inspect r h e o s t a t f o r
c o n t r o l 5HA proper function.
Replace temperature
c o n t r o l a s required.
Heating c a r t r i d g e s Faulty c o n t r o l u n i t Check p e r wiring
do not g e t hot 19VE diagram. Inspect
when t h e a x i a l f a n e l e c t r i c a l and
i s operating ground connections.
Replace c o n t r o l u n i t
as necessary
One h e a t i n g Faulty heating Check h e a t i n g
cartridge f a i l s c a r tridge cartridge f or
c o n t i n u i t y and
replace a s necessary

Table 802-1 Troubleshooting (1 of 2 )

B 0 105
CHAPTER 802
Page 5
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105'

NOTE Item 6 of t h e following t a b l e a p p l i e s t o t h e 3tlkW configuration


only .
TROUBLESHOOTING (continued)

No. TROUBLE SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION

Applicable c i r c u i t Check c i r c u i t breaker


breaker i n c o n t r o l f o r c o n t i n u i t y and
unit i s faulty r e p l a c e a s necessary
4 Smell of burning Burned winding i n Replace a x i a l fan
i n cockpit a x i a l f a n 8HA

Heating c a r t r i d g e s Check heating


do not shut o f f c a r t r i d g e s and
themoswitches;
replace faulty parts
5 Temperature cannot Temperature c o n t r o l Check per wiring
be r e g u l a t e d c i r c u i t board 4HA diagram. Replace
faulty; faulty r h e o s t a t 5HA o r
temperature c o n t r o l c i r c u i t board 4HA
6 Heater blower 22HA Faulty h e a t e r blower Measure voltage .
(cargo compartment Replace heater blower
h e a t i n g system) a s required.
inoperative

Faulty wiring o r Check per wiring


i n s u l a t i o n between diagram. Repair
toggle switch 3HA wiring o r i n s u l a t i o n
and f a n h e a t e r 22HA and replace f a u l t y p a r t s
Faulty a u x i l i a r y c o n t r o l Remove c o n t r o l u n i t
unit and check per wiring
diagram. Replace f a u l t y
parts
Faulty t o g g l e switch Perform f u n c t i o n a l
3HA o r 30HA check and replace
a s necessary

Table 802-1 Troubleshooting ( 2 of 2 )

B0 1 0 5
CHAPTER 802
Page 6
EUROCOPTER MAINTENANCE MANUAL B 0 105

802 -3 INSPECTION SCHEDULE (refer to Chapter 101) I

Revision 18 CHAPTER 802


Page 7
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105

802 -4 INSPECTION FOR CONDITION - ELECTRICAL HEATING AND VENTILATION


SYSTEM 4kW/3tlkW

General
- Inspection items 1. t h r u 4 . r e q u i r e p r i o r removal of t h e nose door.
- ~ n s ~ e c t i oitem
n 8. a p p l i e s t o t h e 3tlkW configuration only.

1. Inspect a x i a l f a n 8HA f o r e x t e r n a l damage and s e c u r i t y of attachment.


Ensure t h a t bonding jumper connection has a good c o n t a c t .

2. Inspect manifold and elbows f o r s e c u r i t y of attachment; t i g h t e n a t t a c h i n g


hardware a s necessary.

3. Inspect f l e x i b l e hoses between manifold and f l o o r Passage f o r damage and


s e c u r i t y of attachment. Replace damaged hoses and t i g h t e n loose clamps.

4 . Inspect control u n i t 19VE and a s s o c i a t e d wiring harness f o r e x t e r n a l


damage and s e c u r i t y of attachment.
5. Inspect a i r i n t a k e f o r s e c u r i t y of attachment and ensure a i r - i n t a k e l e v e r
functions properly.
6. Inspect f l e x i b l e hoses i n t h e f e e t a r e a f o r chafe marks and breaks, and
replace it necessary. Tighten l o o s e clamps.
7. Inspect heating c a r t r i d g e s and vent nozzles f o r e x t e r n a l damage and
a s s o c i a t e d support brackets f o r s e c u r i t y of attachment.
8. Inspect heater blower 22HA, a u x i l i a r y c o n t r o l u n i t 31HA and wiring harness
f o r e x t e r n a l damage and s e c u r i t y of attachment.

802 -5 FUNCTIONAL CHECK - ELECTRICAL HEATING AND VENTILATION


SYSTEM 4kW/3+lk~

- The system s h a l l be f u n c t i o n a l l y checked not only a t t h e s p e c i f i e d time


i n t e r v a l s but a l s o a f t e r replacement of e l e c t r i c a l components.
- The functional check s h a l l only be performed using an e x t e r n a l power
supply o r with engines running and g e n e r a t o r s operating.
- I f rescue h o i s t i s i n s t a l l e d , s e t h o i s t master switch WINCH t o OFF.
- Depress following c i r c u i t breakers:
On t h e instrument panel: 1HA and 2HA
On t h e overhead console: 13HA, 14HA, 15HA, 16HA and 17HA

B 0 105
CHAPTER 802
Page 8
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
1. Functional test - heating
a. Engage e x t e r n a l power supply o r s t a r t engines i n t u r n and a c t i v a t e
both generators.

NOTE I f only one generator i s a c t i v a t e d o r serviceable,


t h e heating system i s designed t o remain OFF.

b. Momentarily press f o u r - l i g h t annunciator: .


S e r v i c e a b i l i t y i s i n d i c a t e d by l i g h t s i l l u m i n a t i n g .

C. Set toggle switch 3HA t o HEATING; t u r n TEMP CONT 5HA f u l l clockwise.

d. Ensure e n t i r e h e a t i n g system i s o p e r a t i n g properly.

2. Functional test - temperature control


a. Close cockpit doors.

b. Set t o g g l e switch 3HA t o HEATING; move a i r - i n t a k e l e v e r t o CABIN A I R ;


t u r n TEMP CONT 5HA f u l l clockwise.

C. Ensure e n t i r e heating system i s o p e r a t i n g properly.

d. Turn TEMP CONT 5HA counterclockwise t o t h e point where t h e cabin


h e a t i n g i s turned o f f ( t h e h e a t e r blower i n t h e cargo conpartment
continues t o operate) .

e. S t a r t t h e cabin h e a t i n g again by t u r n i n g t h e temperature c o n t r o l knob


clockwise. I £ t h e cabin temperature r i s e s above o r f a l l s below t h e
p r e s e l e c t e d temperature, t h e heating system w i l l t u r n o f f o r on
r e s p e c t i v e l y (does not apply t o t h e cargo compartment).
3. Functional t e s t - ventilation
a. Set t o g g l e switch 3HA t o BLOWER.

b. Ensure a x i a l fan 8HA i s o p e r a t i n g properly.

802 - 6 Removal - vent nozzles


1. Side vent nozzles:
Loosen clamp (16, f i g . 802-5) and detach vent nozzle from adapter ( 1 7 ) .
2. Center vent nozzles:

a. Remove screws (27) and washers (26) and detach h e a t i n g c a r t r i d g e f r o n


bracket (25) .

B 0 105
CHAPTER 802
Page 9
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B 0 105'

b. Remove screws (24) and remove cover of heating c a r t r i d g e e l e c t r i c a l


terminal box; disconnect e l e c t r i c a l l e a d (13) .
C. Loosen clamp (16) and detach vent nozzle from adapter ( 1 7 ) .

1. Side vent nozzles:


I n s t a l l and a l i g n vent nozzle on adapter and secure w i t h clamp (16,
f i g . 802-5).
2. Center vent nozzles:

a. I n s t a l l vent nozzle on adapter, but do not t i g h t e n clamp (16) a t t h i s


time .
b. Connect e l e c t r i c a l l e a d (13) and secure cover of heating c a r t r i d g e
e l e c t r i c a l terminal box with screws ( 2 4 ) .
C. Secure heating c a r t r i d g e t o bracket (25) with screws (27) and washers
(26); a l i g n vent nozzle on adapter and t i g h t e n clamp (16).

802 - 8 Removal - heating c a r t r i d g e s


1. Side heating c a r t r i d g e :

a. Remove screws (24, f i g . 802-5) and detach cover of heating c a r t r i d g e


.
e l e c t r i c a l terminal box; disconnect e l e c t r i c a l l e a d (22)
b. Loosen clamp ( 2 1 ) ; remove screws (27) and washers (26) and p u l l
heating c a r t r i d g e out of f l e x i b l e hose.
C. Loosen clamp (16) and remove a t t a c h i n g hardware (18, 1 9 and 20) .
Remove assembled vent nozzle and adapter from heating c a r t r i d g e .
2 . Center heating c a r t r i d g e :

a . Loosen clamp (21) ; remove screws (27) and washers (26) and p u l l
heating c a r t r i d g e out of f l e x i b l e hose.
b. Remove screws ( 2 4 ) and detach cover of heating c a r t r i d g e e l e c t r i c a l
terminal box; disconnect e l e c t r i c a l l e a d s (13 and 2 2 ) .
C. Loosen clamp ( 1 6 ) and remove a t t a c h i n g hardware (18, 19 and 20);
remove assembled vent nozzle and adapter from heating c a r t r i d g e .

B 0 105
CHAPTER 802
Page 10
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 9 Installation - heating cartridges

1. Side h e a t i n g c a r t r i d g e

a. Secure assembled vent nozzle and adapter t o h e a t i n g c a r t r i d g e w i t h


screws (18, f i g . 802-5), washers (19) and n u t s ( 2 0 ) .
b. Secure heating c a r t r i d g e t o bracket (25) with screws (27) and washers
( 2 6 ) . Connect l o o s e end of hose t o h e a t i n g c a r t r i d g e adapter and
secure with clamp ( 2 1 ) .
C. Connect e l e c t r i c a l lead (22) and i n s t a l l cover of heating-cartridge
junction box with screws ( 2 4 ) .

d. Align vent nozzle on adapter and secure with clamp ( 1 6 ) .


e. Perform f u n c t i o n a l check ( r e f e r t o Para 802-5).

2. Center heating c a r t r i d g e
a. Secure assembled vent nozzle and a d a p t e r t o h e a t i n g c a r t r i d g e with
screws (18), washers (19) and n u t s (20) .
b. Connect e l e c t r i c a l leads (13, 22) and i n s t a l l cover of heating
c a r t r i d g e junction box with screws ( 2 4 ) .
C. Secure heating c a r t r i d g e on bracket (25) with screws (27) and washers
( 2 6 ) . Connect l o o s e end of hose t o h e a t i n g c a r t r i d g e adapter and
secure with clamp ( 2 1 ) .
d. Align vent nozzle on adapter and secure with clamp ( 1 6 ) .
e. Perform f u n c t i o n a l check ( r e f e r t o Para 802-5).

802 - 10 Removal - a x i a l fan

NOTE Removal of t h e a x i a l f a n r e q u i r e s p r i o r removal of t h e nose door.

1. Remove screws (8, f i g . 802-5) from support b r a c k e t s (6, 9) and remove


bonding jumper ( 1 0 ) .
2. Withdraw a x i a l fan ( 3 ) .

3. Loosen screws (11) and detach cover of junction box ( 7 ) .

4 . I d e n t i f y e l e c t r i c a l wiring t o a i d reconnecting and disconnect


e l e c t r i c a l wiring from junction box.

B 0 105
CHAPTER 802
Page 11
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 11 Installation - a x i a l fan

NOTE Arrow on a x i a l f a n housing p o i n t s l e f t .

1. Connect e l e c t r i c a l wiring t o junction box (7, f i g . 802-5).

2 . I n s t a l l cover of junction box with screws (11).

3. F i t a x i a l f a n (3) between support brackets (6 and 9 ) . I n s t a l l manifold and


elbow mounting flange on support brackets (6 and 9) r e s p e c t i v e l y with
screws .
4 . I n s t a l l bonding jurnper ( 1 0 ) .
5. Perform f u n c t i o n a l check ( r e f e r t o para 802-5).

802 - 12 Replacement - carbon brushes ( a x i a l f a n )


1. Remove a x i a l f a n ( r e f e r t o para 802-10).

2. Remove screw (35, f i g . 802-5) and remove cover ( 3 6 ) .


3. Remove screws (37) and washers (38) and remove carbon brushes (39) from
t h e holders .
4 . I n s e r t carbon brushes i n t h e holders and secure with screws and washers.

5. F i t cover and secure with screw.


6. Connect a x i a l fan t o 28 VDC supply and t o ground.

NOTE If using new unlapped carbon brushes, t h e a x i a l fan


must be operated f o r 12 hours i n order t o l a p them.

7. I n s t a l l a x i a l fan ( r e f e r t o para 802-11).

B 0 105
CHAPTER 802
Page 12
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 13 Removal - control unit
1. I d e n t i f y e l e c t r i c a l w i r i n g t o a i d reconnection and disconnect from c o n t r o l
u n i t (12, f i g . 802-5) ; disconnect bonding jumper.

2. Remove screws (5) and withdraw c o n t r o l u n i t .

802 - 14 Installation - control unit


1. I n s t a l l c o n t r o l u n i t (12, f i g . 802-5) with screws ( 5 ) .

2. Connect e l e c t r i c a l wiring and bonding jumper.


3. Perform f u n c t i o n a l check ( r e f e r t o para 802-5).

802 - 15 Replacement - f l e x i b l e hoses

1. Loosen a l l clamps and c a r e f u l l y withdraw o l d f l e x i b l e hose.

2 . Route new hose through t h e f l o o r panel from below and a t t a c h t o heating


c a r t r i d g e hose adapter with clamp.
3. S l i d e clamps onto f r e e end of hose, p o s i t i o n hose a s i n s t r u c t e d , and
t i g h t e n clamps.

CAUTION TAKE CARE THAT THERE IS NO INTERFERENCE WITH THE


BELLCRANK OF THE RUDDER CONTROLS.

802 - 16 Removal - h e a t e r blower


1. Remove screws (30, f i g . 802-5) and washers (31) and remove h e a t e r blower
from bracket (32) .
2. Remove junction box Cover.
3. Disconnect e l e c t r i c a l wiring.

B 0 105
CHAPTER 802
Page 13
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 17 Installation - heater blower
1. Connect e l e c t r i c a l wiring.

2. Attach junction box Cover.


3. P o s i t i o n h e a t e r blower (29, f i g . 802-5) i n bracket (32) and secure with
screws (30) and washers ( 3 1 ) .
4 . Perform f u n c t i o n a l check ( s e e Para 802-5).

802 - 18 Removal - auxiliary control unit

1. Open and secure r e a r clamshell doors.

2. Remove f a i r i n g from t h e canted frame on t h e a f t r i g h t hand s i d e of t h e


h e l i c o p t e r . The a u x i l i a r y c o n t r o l u n i t (33, f i g . 802-5) i s a t t a c h e d t o t h e
forward s i d e of t h e canted frame.
3. Remove e l e c t r i c a l connector (34) .
4 . Remove screws (28) and withdraw a u x i l i a r y c o n t r o l u n i t .

802 - 19 Installation - auxiliary control unit


1. I n s t a l l a u x i l i a r y c o n t r o l u n i t (33, f i g . 802-5) t o canted frame with
screws (28) .
2. Connect e l e c t r i c a l connector ( 3 4 ) .
3 . I n s t a l l f a i r i n g on canted frame and c l o s e r e a r clamshell doors.
4 . Perform f u n c t i o n a l check ( r e f e r t o para 802-5).

B0 105
CHAPTER 802
Page 1 4
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 1 0 5

1 Heating c a r t r i d g e 18HA
2 Heating c a r t r i d g e 19HA
3 Heating c a r t r i d g e 20HA
4 Heating c a r t r i d g e 21HA
5 Axial fan 8HA
6 Control u n i t 19VE
7 Temperature control 5HA
8 Toggle switch 3HA
9 Annunicator panel 7HA
10 C i r c u i t board 4HA
11 Main r e l a y box 1VE
12 C i r c u i t breaker 1HA
13 C i r c u i t breaker 2HA

Fig. 802-1 E l e c t r i c a l heating and v e n t i l a t i o n system 4kW -


c o n t r o l element s
B0 105
CHAPTER 802
Page 1 5
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105

VlEW B

VlEW A

Heating c a r t r i d g e 18HA
Heating c a r t r i d g e 19HA
Heating c a r t r i d g e 21HA
Axial f a n 8HA
Control u n i t 19VE
Heater blower 22HA
Temperature c o n t r o l 5HA
Toggle switch 3HA
Four - l i g h t
annunciator 7HA
C i r c u i t board 4HA
Toggle switch 30HA
A u i l i a r y control
uni t 3 1HA
Main r e l a y box 1VE
C i r c u i t breaker 1HA
C i r c u i t breaker 2HA
Fig. 802-2 E l e c t r i c a l h e a t i n g and v e n t i l a t i o n system 3tlkW -
c o n t r o l elements
B0 105
CHAPTER 802
Page 16
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105

AUXlLlARY BUS WlNCH MASTER SWlTCH 4MF

BLOWER 8HA

I f rescue h o i s t i s i n s t a l l e d ,
c i r c u i t i s energized through
h o i s t master switch

F i g . 802-3 E l e c t r i c a l heating and v e n t i l a t i o n system 4kW - schematic


diagram
B0 105
CHAPTER 802
Page 1 7
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105

ONTROL UNlT 19 VE
.-.-.P.

BLOWER 8HA

I f rescue h o i s t i s i n s t a l l e d ,
c i r c u i t i s energized through
hoist master switch

Fig. 802-4 E l e c t r i c a l heating and v e n t i l a t i o n system 3tlkw - Schematic


diagram
B0 105
CHAPTER 802
Page 18
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B 0 105

A i r intake C 1 amp
Air intake lever Electrical lea
A x i a l f a n 8HA . Heating c a r t r i
Frech-air i n l e t Screw
Screw Bracket
Support bracket Washer
J u n c t i o n box Screw
Screw Screw
Support brackec Heater blower
Bonding jurnper Screw
Screw Washer
C o n t r o l u n i t 19VE Bracket
Electrical lead Auxiliary cont
Vent n o z z l e , r e n t e r u n i t 31HA
Venc n o z z l e , s i d e E l e c t r i c a l con
C 1amp Screw
Adapter Cover
Screw Screw
Washer Washer
Nut Carbon b r u s h

Fig. 802-5 E l e c t r i c a l heating and v e n t i l a t i o n system 4kW/3+lkW


B0 105
CHAPTER 802
Page 19/20