chapt_802
chapt_802
Table of Contents
B0 105
CHAPTER 802
Page 112
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
1. General
a. Heating
S e t t i n g t h e overhead console-mounted switch BLOWER-OFF-HEATING 3HA t o
HEATING a c t i v a t e s t h e a x i a l fan 8HAI which s u p p l i e s t h e d i s t r i b u t i o n
system with e i t h e r f r e s h (outside) a i r o r cabin a i r , depending on t h e
p o s i t i o n of t h e a i r - i n t a k e l e v e r i n t h e ribbed Cover of t h e a i r
intake .
Turning t h e r o t a r y c o n t r o l knob TEMP CONT 5HA on t h e overhead console
clockwise a c t i v a t e s t h e c e n t r a l l y mounted IkW h e a t i n g c a r t r i d g e s 18HA
and 19HA through r e l a y 9HA, and t h e l a t e r a l l y mounted IkW heating
c a r t r i d g e s 20HA and 21HA i n t h e 4kW configuration, through r e l a y l O H A
( s e e f i g . 802-3) .
I n t h e 3tlkW configuration, t h e h e a t i n g c a r t r i d g e 20HA i n t h e 4kW
configuration i s replaced by a h e a t e r blower 22HA which i s c o n t r o l l e d
through t h e a u x i l i a r y c o n t r o l u n i t 31HA by t o g g l e switch CARGO COM
HEATING 30HA l o c a t e d on t h e overhead console. I n t h e ON p o s i t i o n ,
cargo compartment heating i s provided, t h e temperature of which
cannot be r e g u l a t e d ( s e e f i g . 802-4).
The lamps of t h e f o u r - l i g h t annunciator HEATING 7HA l o c a t e d i n t h e
bottom l e f t hand Corner of t h e overhead console, l i g h t up when t h e i r
r e s p e c t i v e h e a t i n g c a r t r i d g e i s energized.
B 0 105
CHAPTER 802
Page 3
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
A l l t h e h e a t i n g c a r t r i d g e s a r e p r o t e c t e d a g a i n s t overheating (approx.
63 O C ) by thermal switches. Additional thermal switches i n t h e c e n t e r
heating c a r t r i d g e s i n t e r r u p t t h e power supply a s soon a s t h e a i r flow
temperature exceeds approx. 30 O C .
b. Ventilation
S e t t i n g t h e overhead console-mounted switch BLOWER-OFF-HEATING 3HA t o
BLOWER provides t h e a x i a l fan 8HA with power from t h e main bus PP21,
while c l o s i n g t h e power path t o t h e f o u r h e a t i n g c a r t r i d g e s i n t h e 4kW
configuration ( s e e f i g . 802-3) v i a blocking diodes l l H A and 12HA (See
f i g . 802-3).
With t h e two switch S e t t i n g s of t o g g l e switch CARGO COM HEATING 30HA,
t h e 3tlkW configuration can provide h e a t i n g of t h e cargo compartment.
I n p o s i t i o n ONI t h e h e a t e r blower 22HA o p e r a t e s i n conjunction with
t h e a x i a l fan. I n p o s i t i o n OFFI both cargo compartment heating and
v e n t i l a t i o n a r e shut down (see f i g . 802-4).
General
- Perform troubleshooting with wiring diagrarns 802-1 and 802-2 i n t h e Wiring
Diagram Manual (WDM) .
- I£ rescue h o i s t i s i n s t a l l e d , s e t i t s master switch WINCH t o OFF.
- Check a l l a s s o c i a t e d switches and c i r c u i t breakers f o r unimpaired
mechanical function.
- Check t h a t a l l a s s o c i a t e d e l e c t r i c a l connections a r e t i g h t and secure.
- Troubleshoot using e i t h e r e x t e r n a l o r g e n e r a t o r power only.
- Depress a l l system c i r c u i t breakers:
On instrument panel: 1HA and 2HA
On overhead console: 13HA, 14HA, 15HAI 16HA and 17HA
- Functionally check a l l f o u r heating c a r t r i d g e s by momentarily p r e s s i n g t h e
f o u r - l i g h t annunciator 7HA i n t h e overhead console.
B 0 105
CHAPTER 802
Page 4
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B 0 105
B 0 105
CHAPTER 802
Page 5
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105'
B0 1 0 5
CHAPTER 802
Page 6
EUROCOPTER MAINTENANCE MANUAL B 0 105
General
- Inspection items 1. t h r u 4 . r e q u i r e p r i o r removal of t h e nose door.
- ~ n s ~ e c t i oitem
n 8. a p p l i e s t o t h e 3tlkW configuration only.
B 0 105
CHAPTER 802
Page 8
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
1. Functional test - heating
a. Engage e x t e r n a l power supply o r s t a r t engines i n t u r n and a c t i v a t e
both generators.
B 0 105
CHAPTER 802
Page 9
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B 0 105'
a . Loosen clamp (21) ; remove screws (27) and washers (26) and p u l l
heating c a r t r i d g e out of f l e x i b l e hose.
b. Remove screws ( 2 4 ) and detach cover of heating c a r t r i d g e e l e c t r i c a l
terminal box; disconnect e l e c t r i c a l l e a d s (13 and 2 2 ) .
C. Loosen clamp ( 1 6 ) and remove a t t a c h i n g hardware (18, 19 and 20);
remove assembled vent nozzle and adapter from heating c a r t r i d g e .
B 0 105
CHAPTER 802
Page 10
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 9 Installation - heating cartridges
1. Side h e a t i n g c a r t r i d g e
2. Center heating c a r t r i d g e
a. Secure assembled vent nozzle and a d a p t e r t o h e a t i n g c a r t r i d g e with
screws (18), washers (19) and n u t s (20) .
b. Connect e l e c t r i c a l leads (13, 22) and i n s t a l l cover of heating
c a r t r i d g e junction box with screws ( 2 4 ) .
C. Secure heating c a r t r i d g e on bracket (25) with screws (27) and washers
( 2 6 ) . Connect l o o s e end of hose t o h e a t i n g c a r t r i d g e adapter and
secure with clamp ( 2 1 ) .
d. Align vent nozzle on adapter and secure with clamp ( 1 6 ) .
e. Perform f u n c t i o n a l check ( r e f e r t o Para 802-5).
B 0 105
CHAPTER 802
Page 11
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 11 Installation - a x i a l fan
B 0 105
CHAPTER 802
Page 12
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 13 Removal - control unit
1. I d e n t i f y e l e c t r i c a l w i r i n g t o a i d reconnection and disconnect from c o n t r o l
u n i t (12, f i g . 802-5) ; disconnect bonding jumper.
B 0 105
CHAPTER 802
Page 13
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
802 - 17 Installation - heater blower
1. Connect e l e c t r i c a l wiring.
B0 105
CHAPTER 802
Page 1 4
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 1 0 5
1 Heating c a r t r i d g e 18HA
2 Heating c a r t r i d g e 19HA
3 Heating c a r t r i d g e 20HA
4 Heating c a r t r i d g e 21HA
5 Axial fan 8HA
6 Control u n i t 19VE
7 Temperature control 5HA
8 Toggle switch 3HA
9 Annunicator panel 7HA
10 C i r c u i t board 4HA
11 Main r e l a y box 1VE
12 C i r c u i t breaker 1HA
13 C i r c u i t breaker 2HA
VlEW B
VlEW A
Heating c a r t r i d g e 18HA
Heating c a r t r i d g e 19HA
Heating c a r t r i d g e 21HA
Axial f a n 8HA
Control u n i t 19VE
Heater blower 22HA
Temperature c o n t r o l 5HA
Toggle switch 3HA
Four - l i g h t
annunciator 7HA
C i r c u i t board 4HA
Toggle switch 30HA
A u i l i a r y control
uni t 3 1HA
Main r e l a y box 1VE
C i r c u i t breaker 1HA
C i r c u i t breaker 2HA
Fig. 802-2 E l e c t r i c a l h e a t i n g and v e n t i l a t i o n system 3tlkW -
c o n t r o l elements
B0 105
CHAPTER 802
Page 16
MBB HELICOPTERS
MAINTENANCE MANUAL MBB - B0 105
BLOWER 8HA
I f rescue h o i s t i s i n s t a l l e d ,
c i r c u i t i s energized through
h o i s t master switch
ONTROL UNlT 19 VE
.-.-.P.
BLOWER 8HA
I f rescue h o i s t i s i n s t a l l e d ,
c i r c u i t i s energized through
hoist master switch
A i r intake C 1 amp
Air intake lever Electrical lea
A x i a l f a n 8HA . Heating c a r t r i
Frech-air i n l e t Screw
Screw Bracket
Support bracket Washer
J u n c t i o n box Screw
Screw Screw
Support brackec Heater blower
Bonding jurnper Screw
Screw Washer
C o n t r o l u n i t 19VE Bracket
Electrical lead Auxiliary cont
Vent n o z z l e , r e n t e r u n i t 31HA
Venc n o z z l e , s i d e E l e c t r i c a l con
C 1amp Screw
Adapter Cover
Screw Screw
Washer Washer
Nut Carbon b r u s h