0% found this document useful (0 votes)
14 views5 pages

DI-16 - SpaceLogic Plant Room Controllers Specification Sheet

The SpaceLogic DI-16 is a 16-channel digital input I/O module designed for cost-effective sensing in applications like equipment status and alarm monitoring. It features a modular design for easy installation and maintenance, including hot-connect and hot-swap capabilities, auto-addressing, and LED status indicators. The module complies with various safety and regulatory standards, making it suitable for diverse environmental conditions.

Uploaded by

fairguy80
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views5 pages

DI-16 - SpaceLogic Plant Room Controllers Specification Sheet

The SpaceLogic DI-16 is a 16-channel digital input I/O module designed for cost-effective sensing in applications like equipment status and alarm monitoring. It features a modular design for easy installation and maintenance, including hot-connect and hot-swap capabilities, auto-addressing, and LED status indicators. The module complies with various safety and regulatory standards, making it suitable for diverse environmental conditions.

Uploaded by

fairguy80
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

DI-16

SpaceLogic™ Plant Room Controllers

EcoStruxure™ Building

16-channel digital input I/O module


Introduction Function
SpaceLogic* DI-16 Central IO module is a digital input, 16- Modular and scalable system
channel I/O module. The modules are part of a modular system that delivers power
and communications on a common bus. Connecting modules is
The digital inputs can be used for cost effective sensing of a one-step process: just slide the modules together using the
multiple dry contact digital inputs in applications, such as built-in connectors.
equipment status monitoring or alarm point monitoring. As
counter inputs, digital inputs are commonly used in energy
Patented two-piece design
metering applications.
Each module can be separated from its terminal base to allow
* Formerly known as SmartX. the site to be wired prior to the installation of the electronics. The
patented locking mechanism serves as handles for removing the

www.se.com/buildings
DI-16
module from its base. All critical components have a protective Simple DIN-rail installation
cover that permits convection cooling to occur. Fasteners easily snap into a locked position for panel installation.
The fastener has a quick-release feature for easy DIN-rail
removal.

Efficient terminal management


The Central IO module terminals are clearly labeled and
protected by transparent covers. The input and output terminals
are at the top and bottom of each module and are accessible for
maintenance without removing the module. The EcoStruxure
Building Operation WorkStation software can generate custom
as-built labels for each module. Pre-perforated letter and A4 size
label sheets are available as an accessory.

Accommodates multiple row panel installations


The SpaceLogic devices use built-in connectors for single row
connectivity, side by side. If a panel size requires multiple rows,
extension cords are available.
Two-piece design

Hot-connect and Hot-swap LED status indicators


Because critical applications require 24-hour operation, The Central IO module has a status indicator that denotes the
Schneider Electric designed the Central IO modules for hot- health and status of the module.
connection of terminal bases and hot-swapping of the modules
to their bases. This design ensures continuous power and Each input channel has a dedicated two color status LED. The
communication during service operations. LED can be configured to display either red or green for each
input state.
Auto-addressing
Protection
The auto-addressing feature helps eliminating the need for
setting DIP switches or pressing commission buttons. Each Protection components on the inputs protect against high-
module automatically knows its order in the chain and assigns voltage short-duration transient events.
itself accordingly – significantly reducing engineering and
maintenance time.

Specifications
DI-16

Input channels 16

DC input supply power 1.6 W

DC input supply voltage 24 VDC

Environment

Ambient temperature, operating 0 to 50 °C (32 to 122 °F)

Ambient temperature, storage -20 to +70 °C (-4 to +158 °F)

Maximum humidity 95 % RH non-condensing

Material

Plastic flame rating UL94-5VB

Enclosure PC/ABS

Ingress protection rating IP 20

DI-16 Life is On | Schneider Electric 2


DI-16
Mechanical

Dimensions including terminal base 90 W x 114 H x 64 D mm (3.6 W x 4.5 H x 2.5 D in.)

Weight including terminal base 0.255 kg (0.56 lb)

Weight excluding terminal base 0.131 kg (0.29 lb)

Terminal base TB-IO-W1

Agency compliances

Emission RCM; BS/EN 61000-6-3; FCC Part 15, Sub-part B, Class B

Immunity BS/EN 61000-6-2

Safety standards BS/EN 61010-1; UL 916 C-UL US Listed

Product BS/EN 61326-1

Smoke control product safety UL 864

Part numbers

DI-16, Central IO module


16 digital inputs SXWDI16XX10001

TB-IO-W1, terminal base for Central IO module


(Required for each Central IO module) SXWTBIOW110001

Accessory part numbers

DIN-RAIL-CLIP, DIN-rail end clip


package of 25 pieces SXWDINEND10001

PRINTOUT-A4-W1, printout sheets for terminal labels


A4 sheet size, 100 sheets, 18 labels per sheet SXWTERLBL10011

PRINTOUT-LTR-W1, printout sheets for terminal labels


Letter sheet size, 100 sheets, 16 labels per sheet SXWTERLBL10012

S-CABLE-L, S-cable extension cord for the I/O bus, L shaped connectors
1.5 m SXWSCABLE10002

S-CABLE-L, S-cable extension cord for the I/O bus, L shaped connectors
0.75 m SXWSCABLE10003

Digital inputs

DI-16 Life is On | Schneider Electric 3


DI-16

Range Dry contact switch closure or open collector/open drain, 24 VDC, 2.4 mA

Absolute maximum ratings -0.5 to +24 VDC

LED polarity Software selectable, if the LED is activated when the input is high or low

LED color Red or green, software selectable

Digital

Minimum pulse width 120 ms

Counter

Minimum pulse width 20 ms

Maximum frequency 25 Hz

For protection from excess current that could be produced by


• For more information on wiring, see the SpaceLogic Hardware
field wiring, follow these instructions:
Reference Guide.

• Connect one RET terminal on each of the Central IO modules


to a common chassis/power ground rail in the control panel
using a size 16 AWG (1.3 mm2), or larger wire.

DI-16 Life is On | Schneider Electric 4


DI-16
Regulatory Notices

Federal Communications Commission CE - Compliance to European Union (EU)


FCC Rules and Regulations CFR 47, Part 15, Class B 2014/30/EU Electromagnetic Compatibility Directive
This device complies with part 15 of the FCC Rules. Operation is subject to the following two 2011/65/EU Restriction of Hazardous Substances (RoHS) Directive
conditions: (1) This device may not cause harmful interference. (2) This device must accept any 2015/863/EU amending Annex II to Directive 2011/65/EU
interference received, including interference that may cause undesired operation. This equipment complies with the rules, of the Official Journal of the European Union, for
Industry Canada governing the Self Declaration of the CE Marking for the European Union as specified in the
This Class B digital apparatus complies with Canadian ICES-003. above directive(s).
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Regulatory Compliance Mark (RCM) - Australian Communications and Media Authority (ACMA) WEEE - Directive of the European Union (EU)
This equipment complies with the requirements of the relevant ACMA standards made under the This equipment and its packaging carry the waste of electrical and electronic equipment (WEEE)
Radiocommunications Act 1992 and the Telecommunications Act 1997. These standards are label, in compliance with European Union (EU) Directive 2012/19/EU, governing the disposal
referenced in notices made under section 182 of the Radiocommunications Act and 407 of the and recycling of electrical and electronic equipment in the European community.
Telecommunications Act.

UL 916 Listed products for the United States and Canada, Open Class Energy Management
UK Conformity Assessed Equipment. UL file E80146.
S.I. 2016/1091 - Electromagnetic Compatibility Regulations 2016
S.I. 2012/3032 - Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
S.I. 2013/3113 - Waste Electrical and Electronic Equipment Regulations 2013 UL 864 Listed products for the United States. 10th Edition Smoke Control System. UL file S5527.
This equipment complies with the rules, of the UK regulations, for governing the UKCA Marking
for the United Kingdom specified in the above directive(s).

www.se.com/buildings

© 2021 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
03-33003-01-en December 2021

You might also like