power genration
power genration
Topics to be covered: These non-conventional sources are also known as renewable sources of energy. The examples include
Generation: Conventional and Non-conventional energy sources, generation of power from Hydro, solar energy, bioenergy, tidal energy and wind energy.
thermal (coal based), nuclear, solar and wind (Block diagram approach), Distributed generation and its 1. Solar Energy: This is the energy that is produced by the sunlight. The energy is utilized for cooking,
benefits.
distillation of water and to produce electricity.
Transmission and Distribution: Primary & Secondary transmission and distribution voltage levels with 2. Wind Energy: Wind energy is generated by harnessing the power of wind and mostly used in
Single line diagram, concept of grid and the need for interconnection of grids. Conditions for operating water pumps for irrigation purposes. India stands the second largest country in the generation
grid Connection, Smart grid- Definition and benefits. of wind power.
Regulatory bodies- Central and State in electrical power sector and their roles. Power tariff- Definition 3. Tidal Energy: The energy that is generated by exploiting the tidal waves of the sea is known as tidal
and types. energy. This source is yet to be tapped due to the lack of cost-effective technology.
4. Bio Energy: This type of energy is obtained from organic matter. It is of two kind:
Introduction: Energy resources are all forms of fuels used in the modern world, either for heating,
(i) Bio Gas: Bio Gas is obtained from Gobar Gas Plant by putting cow dung into the plant. Besides
generation of electrical energy, or for other forms of energy conversion processes. Energy is one of the
major parts of the economic infrastructure, being the basic input needed to sustain the economic producing gas this plant converts gobar into manure. It can be used for cooking, lighting and
growth. Human civilization relies on different sources of energy. generation of electricity.
(ii) Bio Mass: It is also of a source of producing energy through plants and trees. The purpose of bio
The two major sources of energy can be classified under:
mass programme is to encourage afforestation for energy.
1. Conventional Sources 5. Energy from Urban Waste: Urban waste poses a big problem for its disposal. Now it can be used for
2. Non-Conventional Sources generation of power.
Penstock: A penstock is a huge steel pipe which carries water from the reservoir to the turbine. Potential
Hydroelectric Power Plant: energy of the water is converted into kinetic energy as it flows down through the penstock due to gravity.
Generation of electricity by hydropower (potential energy in stored water) is one of the cleanest methods
of producing electric power. Hydroelectricity is the most widely used form of renewable energy. It is a Surge Tank: Surge tanks are usually provided in high or medium head power plants when considerably long
flexible source of electricity and also the cost of electricity generation is relatively low. Figure A shows penstock is required. A surge tank is a small reservoir or tank which is open at the top. It is fitted between the
the block diagram of a hydroelectric power plant and figure B shows the typical layout of the reservoir and the power house. The water level in the surge tank rises or falls to reduce the pressure swings
hydroelectric power plant and its basic components. in the penstock. When there is sudden reduction in load on the turbine, the governor closes the gates of the
turbine to reduce the water flow. This causes pressure to increase abnormally in the penstock. This is
prevented by using a surge tank, in which the water level rises to reduce the pressure. On the other hand, the
surge tank provides excess water needed when the gates are suddenly opened to meet the increased load
demand.
Power House: The powerhouse accommodates the water turbine, generator, transformer, and control room.
Water Turbine: Water from the penstock is taken into the water turbine. The turbine is mechanically coupled
to an electric generator. Kinetic energy of the water drives the turbine. There are two main types of water
turbine; (i) Impulse turbine and (ii) Reaction turbine. Impulse turbines are used for large heads and reaction
turbines are used for low and medium heads.
Tailrace: Tailrace is a water path to lead the water discharged from the turbine to the river or canal. The water
held in the tailrace is called the Tailrace water level.
Figure A: Block diagram of a hydroelectric power
Generator: A generator is mounted in the power house and it is mechanically coupled to the turbine shaft.
When the turbine blades are rotated, it drives the generator and electricity is generated which is then stepped
up with the help of a transformer for the transmission purpose.
Work ing :
Hydroelectric power plant (Hydel plant) utilizes the potential energy of water stored in a dam built across
the river. The potential energy of the stored water is converted into kinetic energy by first passing it
through the penstock pipe. The kinetic energy of the water is then converted into mechanical energy in a
water turbine. The turbine is coupled to the electric generator. The mechanical energy available at the
shaft of the turbine is converted into electrical energy by means of the generator.
Those power stations which convert chemical energy of fuel (coal, gas etc.) into electrical energy are 1. Coal and Ash Handling Arrangement: The coal and ash handling plant generally consists of:
called thermal power stations. The fuel used in thermal power stations is coal or gas. The heat of
combustion of coal is utilized to convert water into steam which runs the steam turbine coupled with the (i) Coal storage,
alternator produces electrical energy. Thus, a thermal power station may sometimes called as a steam (ii) (ii) Coal handling plant,
power station. Almost two third of electricity requirement of the world is fulfilled by thermal power (iii) (iii) Ash handling plant, and
plants (or thermal power stations). Figure A shows the block diagram of a Thermal power plant and (iv) (iv) Ash storage.
figure B shows the typical layout of the Thermal power plant and its basic components.
The coal is stored in a coal storage plant from where it is delivered to the coal handling plant. In coal
handling it is crushed into small pieces for proper burning. The coal in the powdered form is burnt in
the boiler. The ash produced after burning of coal is removed to ash storage
2. Boiler: The heat of combustion produced by burning coal in the boiler is used to heat up water for
producing steam. The steam produced is wet, therefore it is passed through a superheater where it is dried
and superheated.
3. Superheater: The wet steam from the boiler is passed through the superheater and superheated by the
flue gases on their way to the chimney. This steam is then injected into the steam turbine blades through
the main steam value.
4. Economizer: The function of economizer is to preheat the feed water by utilizing the heat of flue
Figure A: Block diagram of a Thermal power plant gases.
5. Air Preheater: The air is drawn from atmosphere by a forced draught fan and passed through air
preheater, where it is heated by flue gases and then admitted to the furnace for the burning of coal.
6. Steam Turbine: The dry and superheated steam from the superheater is fed to the steam turbine to
convert heat energy of steam into mechanical energy.
7. Condenser: The used up steam is exhausted to the condenser where it is converted to water which is
again fed to the boiler.
8. Alternator: The alternator and turbine are coupled together. The mechanical power is converted to
electrical energy by alternator. The output electrical energy is delivered to the bus through transformers,
circuit breakers and isolators.
Work ing :
In these power stations, the heat produced by combustion of coal is utilized to convert water into steam
which runs the steam turbine coupled with the alternator to produce electrical energy. After the steam
passes through the steam turbine, it is condensed in a condenser and again fed back into the boiler to
become steam.
In Nuclear power plants heat is generated by splitting atoms of radioactive material under controlled
conditions. The most amazing feature of a nuclear power plant is that huge amount of electrical energy
can be produced from a small amount of nuclear fuel.
The fuel rods constitute the fission material and release huge amount of energy when bombarded with
slow moving neutrons.
The moderator consists of graphite rods which enclose the fuel rods. The moderator slows down the
neutrons before they bombard the fuel rods.
The control rods are of cadmium and are inserted into the reactor. Cadmium is strong neutron absorber
and thus regulates the supply of neutrons for fission. When the control rods are pushed in deep enough,
they absorb most of fission neutrons and hence few are available for chain reaction which, therefore,
stops. However, as they are being withdrawn, more and more of these fission neutrons cause fission and
hence the intensity of chain reaction (or heat produced) is increased. Therefore, by pulling out the control
rods, power of the nuclear reactor is increased, whereas by pushing them in, it is reduced.
(ii) Coolant: The heat produced in the reactor is absorbed by the coolant, generally a sodium metal. The
coolant carries the heat to the heat exchanger.
(iii) Heat Exchanger. The coolant gives up heat to the heat exchanger which is utilized in raising the
steam. After giving up heat, the coolant is again fed to the reactor.
(iv) Steam Turbine. The steam produced in the heat exchanger is led to the steam turbine through a
Figure A: Schem atic arrangem ent of a nuclear power plant valve. After doing a useful work in the turbine, the steam is exhausted to condenser.
(i) Nuclear Reactor. It is an apparatus in which nuclear fuel (U235) is subjected to nuclear fission. It
controls the chain reaction that starts once the fission is done. If the chain reaction is not controlled, the Working :
result will be an explosion due to the fast increase in the energy released. A nuclear reactor is a cylindrical
pressure vessel and houses fuel rods of Uranium, moderator and control rods as shown in Figure B. In Nuclear power plants heat is generated by splitting atoms of radioactive material under controlled
conditions. The heat energy thus produced is used in generating steam at high temperature and pressure.
This steam drives the steam turbine, which converts steam energy into mechanical energy. The turbine
spins the alternator, which converts mechanical energy into electrical energy.
Solar Power Generation:
A solar power system transforms solar radiation directly into electricity. The heart of a solar power
Wind Power Generation
system or solar photovoltaic (PV) system are solar cells, which are interconnected to form solar
modules (solar panels) and solar arrays. Modules and arrays can be used to charge batteries, operate Using wind energy is another way of producing electricity. Windmills are devices that harness wind
motors, and to power any number of electrical loads. With the appropriate power conversion equipment, energy, and act like turbines in order to produce electricity. The rotating blades are connected to
solar power systems can produce alternating current (AC) compatible with any conventional appliances, generators via cables, which transfer kinetic energy to the generators.
and can operate in parallel with, and interconnected to the utility. Figure A shows the block diagram of
solar energy conversion systems: The turbine rotor, gear box and generator are the three main components of wind energy conversion
system.
• Rotor converts wind energy to mechanical energy.
• Gear box is used to adapt to the rotor speed to generator speed.
• Generator with the variable speed wind turbine along with electronic inverter absorbs mechanical
power and convert to electrical energy.
• The power converter can not only transfer the power from a wind generator, but also improve the
stability and safety of the system.
1. Solar Panels: It is the heart of the solar power plant. Solar panels consists a number of solar cells.
Solar cells are the energy generating unit, made up of p-type and n-type silicon semiconductor. The
energy produced by each solar cell is very small
2. D.C. to D.C. Converter (Choppers): Solar panels produce direct current which is very small and Working:
required to be increased so D.C. to D.C. Converter steps up the DC voltage level. DC loads can be fed
Wind turbines operate on a simple principle. Wind is merely air in motion. Wind turbines convert kinetic
directly from this supply.
energy from the wind that passes over the rotors into electricity. The kinetic energy in the wind turns
3. Battery: Batteries are used to produce the power back or store the excess energy produced during two or three propeller-like blades around a rotor. The rotor is connected to the main shaft, which spins a
day, to be supplied during night.
generator to create electricity. Wind turbines are mounted on a tower to capture the most energy. At 100
4. D.C. to A.C. Converter (Inverter) Solar panels produce direct current which is required to be feet (30 meters) or more above ground, they can take advantage of faster and less turbulent wind. Wind
converted into alternating current to be supplied to homes or power grid. turbines can be used to produce electricity for a single home or building, or they can be connected to an
Whenever the sun light falls on the solar panel, the solar cells generate electricity. This DC is stepped up
using DC to DC converter. DC loads can be fed directly from this supply. Then DC electricity is fed to
an inverter that converts DC to AC which can then be used to feed the AC loads. If a grid connect system
is producing more power than is being consumed, the surplus is fed into the mains power grid. When the
solar cells are not producing power, for example at night, power is supplied by the main power grid as
usual.
Single Line Diagram of AC Power Transmission and Distribution System
Distributed Generation
Distributed generation is the term used when electricity is generated from sources, often renewable
energy sources, near the point of use instead of centralized generation sources from power plants. Hence
Distributed generation is also called as on-site generation, Distributed generation reduces the amount of
energy lost during transmission because the electricity is generated near the point of consumption. A
distributed generation system is designed to employ small-scale power generation technologies to
produce electricity close to the end consumers of the power. They meet local peak loads and reduce the
size and amount of power lines that need to be built.
In the residential sector, common distributed generation systems include:
• Solar photovoltaic panels
• Small wind turbines
• Natural-gas-fired fuel cells
• Emergency backup generators, usually fueled by gasoline or diesel fuel
In the commercial and industrial sectors, distributed generation can include resources such as:
• Combined heat and power systems
• Solar photovoltaic panels
• Wind
• Hydropower
• Biomass
• Municipal solid waste incineration
• Fuel cells fired by natural gas or biomass
Primary distribution
• The secondary transmission line terminates at the substation where the voltage is reduced from 66
kV / 11 kV by step down transformer.
• The 11 kV voltage is transmitted to different area of city by transmission line.
• The primary transmission is done through 3 – phase, 3 – wire system which supply power to HT
consumers.
Secondary distribution
• The electrical power from primary distribution line is delivered to pole mounted distribution
transformer.
The Indian Power system for planning and operational purposes is divided into five regional grids. The
• The pole mounted delta / star transformer steps down the 11 kV to 440 V. integration of regional grids, and there by establishment of National Grid was conceptualized in early
• The residential consumer gets single phase supply through one phase and neutral (Phase R and N, nineties
Phase Y and N, Phase B and N).
Initially, State grids were inter-connected to form regional grid and India was demarcated into 5
regions namely Northern, Eastern, Western, North Eastern and Southern region.
In October 1991 North Eastern and Eastern grids were connected.
In March 2003 WR and ER-NER were interconnected.
August 2006 North and East grids were interconnected thereby 4 regional grids Northern, Eastern,
Western and North Eastern grids are synchronously connected forming central grid operating at
one frequency.
On 31st December 2013, Southern Region was connected to Central Grid in Synchronous mode
with the commissioning of 765kV Raichur-Solapur Transmission line thereby achieving 'ONE
NATION'-'ONE GRID'-'ONE FREQUENCY'.
Need for Interconnection of Grids
Regulatory Bodies
1. The interconnection of the grid provides the best use of power resource and ensures great security to 1. Central Electricity Regulatory Commission (CERC)
supply.
2. It makes the system economical and reliable. The CERC and SERCs were set up by the 1998 Act (later reconstituted under the Electricity Act, 2003)
with the objectives of depoliticizing the sector and incentivising private investment. The Central
3. The generating stations are interconnected for reducing the reserve generation capacity in each area.
Electricity Regulatory Commission (CERC) intends to promote competition, efficiency and economy in
4. If there is a sudden increase in load or loss of generation in a zone, then it borrows from the adjacent bulk power markets, improve the quality of supply, promote investments and advise government on the
interconnected area. removal of barriers to bridge the demand supply gap and thus foster the interests of consumers. The
Central Electricity Regulatory Commission (CERC) regulates tariff for generating companies owned or
controlled by the Central Government and those with an inter-State dimension, and for inter-State
Conditions for Grid Connection
transmission of electricity.
1. The phase sequence (or phase rotation) of the three phases of the generator must be the same as the
phase sequence of the three phases of the grid.
As entrusted by the Electricity Act, 2003 the Commission has the responsibility to discharge the
2. The magnitude of the sinusoidal voltage produced by the generator must be equal to the magnitude
of the sinusoidal voltage of the grid. following functions:
3. The frequency of the sinusoidal voltage produced by the generator must be equal to the frequency of • To regulate the tariff of generating companies owned or controlled by the Central Government.
the grid.
4. Phase angle between difference the voltage produced by the generator and the voltage produced by • To regulate the tariff of generating companies other than those owned or controlled by the Central
the grid must be zero. Government, if such generating companies enter into or otherwise have a composite scheme for
generation and sale of electricity in more than one State.
• To regulate the inter-State transmission of electricity.
More efficient transmission of electricity CERC can advise the government on National Electricity Policy and tariff policy, and on promoting
Quicker restoration of electricity after power disturbances efficiency, competition and private investment in the sector. It is bound by Central Government/ Central
Electricity Autority (CEA) policy in the discharge of its functions.
Reduced operations and management costs for utilities, and ultimately lower power costs for
consumers
Reduced peak demand, which will also help lower electricity rates 2. State Electricity Regulatory Commission (SERC)
Increased integration of large-scale renewable energy systems SERCs are appointed by the State Governments to regulate generation, transmission, wheeling and
Better integration of customer-owner power generation systems, including renewable energy distribution of electricity within the State. The main function of SERC are.
systems
Improved security.
They regulate power purchase and procurement processes, issue licenses and determine tariffs for
electricity operations in the State.
They are also responsible for adjudicating disputes between licensees and distribution companies.
They have similar standards setting and policy advisory roles as the CERC in relation to the State,
and are bound to follow national electricity and tariff policy in the discharge of their functions.
Electricity Rates or Tariff
Today’s interconnected power systems supply a number of consumers. The supply companies have to
sell their electricity at such a rate that it covers the costs of generation, transmission, distribution, the
salaries of the employees, the interest and depreciation and the profit targeted by the company. This rate
at which electrical energy is sold to the consumers is termed as ‘tariff.’
The cost of generation of electricity will depend upon various factors such as Connected Load, Maximum
Demand, Load factor, Demand Factor, Diversity Factor, Plant Capacity Factor and Use Factor. These, in
turn, will depend upon the type of load and load conditions. Hence, the tariff is different for different
type of loads (and hence different consumers). Therefore, while fixing the tariff, we have to consider
various consumers (industrial, domestic, commercial, etc.) and their requirements. Advantages:
Simplest method
Characteristics of Tariff Easily understandable and easy to apply
A tariff must have following desirable characteristics − Each consumer has to pay according to his utilization
Simplicity – The tariff should be simple so that an ordinary consumer can easily understand it. Disadvantages
Fairness – The tariff should be fair so that the different types of consumers are satisfied with the
There is no discrimination according to the different types of consumers.
rate of charge of electricity.
Attractive – The tariff should be attractive so that large number of consumers are encouraged to The cost per unit is high.
use electricity. There are no incentives
Proper Return – The tariff should be such that it ensures the proper return from each consumer, If a consumer does not consume any energy in a particular month, the supplier cannot charge any
i.e. the total receipt from the consumers must be equal to the cost of production and distribution money even though the connection provided to the consumer has its own costs.
with reasonable profit.
Application
Keeping in mind the above factors, various types of tariff have been designed. The most commonly
used are given below. Generally applied to tube wells used for irrigation purposes.
uniform tariff. The rate per unit of energy does not depend upon the quantity of energy used by a category is charged at a fixed rate similar to Simple Tariff. The different rates are decided according to
consumer. the consumers, their loads and load factors.
Graphically, it can be represented as follows:
The price per unit (1 kWh) of energy is constant. This energy consumed by the consumer is recorded
by the energy meters. Graphically, it can be represented as follows:
Advantages
Generally applied to domestic consumers. Generally applied to residential and small commercial consumers.
In this tariff, the first block of the energy consumed (consisting of a fixed number of units) is charged at In this tariff scheme, the total costs charged to the consumers consist of two components: Fixed charges
a given rate and the succeeding blocks of energy (each with a predetermined number of units) are charged and Running charges. It can be expressed as:
at progressively reduced rates. The rate per unit in each block is fixed. Total Cost = [A (kW) + B (kWh)] Rs.
For example, the first 50 units (1st block) may be charged at 3 rupees per unit; the next 30 units (2nd Where, A = charge per kW of max demand (i.e. A is a constant which when multiplied with max
block) at 2.50 rupees per unit and the next 30 units (3rd block) at 2 rupees per unit. demand (kW) gives the total fixed costs.)
B = charge per kWh of energy consumed (i.e. B is a constant which when multiplied with units
Graphically, it can be represented as follows:
consumed (kWh), gives total running charges.)
The fixed charges will depend upon maximum demand of the consumer and the Running charge will
depend upon the energy (units) consumed.
Advantages
If a consumer does not consume any energy in a particular month, the supplier will get the return
(II) KW and KVAR Tariff
equal to the fixed charges.
Disadvantages In this tariff scheme, the active power (kW) consumption and the reactive power (kVAR) consumption
is measured separately. A consumer having low power factor load will have to pay more fixed charges.
Even if a consumer does not use any electricity, he has to pay the fixed charges regularly.
The maximum demand of the consumer is not determined. Hence, there is error of assessment of
max demand and hence conflict between the supplier and the consumer. (III) Sliding Scale Tariff
Application In this type of tariff scheme, an average power factor (generally 0.8 lagging) is taken as reference.
Generally applied to industrial consumers with appreciable max demand. Now, if the power factor of the consumer’s loads is lower than the reference, he is penalized
accordingly. Hence, a consumer having low power factor load will have to pay more fixed charges.
Also, if the pf of the consumer’s load is greater than the reference, he is awarded with a discount. This
5. Maximum Demand Tariff gives incentives to the consumers. It is usually applied to large industrial consumers.
In this tariff, the energy consumed is charged on the basis of maximum demand. The units (energy)
consumed by consumer is called maximum demand. The maximum demand is calculated by a 7. Three Part Tariff
maximum demand meter. This removes any conflict between the supplier and the consumer as it were
In this scheme, the total costs are divided into 3 sections: Fixed costs, semi-fixed costs and running
the two part tariff. It is similar to two-part tariff.
costs.
Total Charges = [A + B (kW) + C (kWh)]
Application
Where, A = fixed charges,
Generally applied to large industrial consumers. B = charge per kW of max demand (i.e. B is a constant which when multiplied with max
demand (kW) gives the total fixed costs.)
C = charge per kWh of energy consumed (i.e. C is a constant which when multiplied
6. Power Factor Tariff
with units consumed (kWh), gives total running charges.)
In this tariff scheme, the power factor of the consumer’s load is also considered. We know that power
factor is an important parameter in power system. For optimal operation, the pf must be high. Low pf Application
will cause more losses and imbalance on the system. Hence the consumers who have low pf loads will This type of tariff is generally applied to big consumers.
be charged more. It can be further divided into the following types:
In this type of tariff, the fixed charges are made on the basis of maximum demand in kVA instead of
KW.
We know that power factor = kW / kVA
Hence, the pf is inversely proportional to kVA demand. Hence, a consumer having low power factor
load will have to pay more fixed charges. This gives the incentive to the consumers to operate their
load at high power factor. Generally, the suppliers ask the consumers to install power factor
correction equipment.