0% found this document useful (0 votes)
10 views

Release Notes M22 V3.2.3

The document outlines the release notes for MYTHIC 22 software version V3.2.3, detailing updates from the previous version V3.2.2. It includes new features, improvements, corrections, and known bugs, along with constraints on installation. Notably, the software must only be installed on specific hardware and includes various enhancements to functionality and user experience.

Uploaded by

Bid R
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
10 views

Release Notes M22 V3.2.3

The document outlines the release notes for MYTHIC 22 software version V3.2.3, detailing updates from the previous version V3.2.2. It includes new features, improvements, corrections, and known bugs, along with constraints on installation. Notably, the software must only be installed on specific hardware and includes various enhancements to functionality and user experience.

Uploaded by

Bid R
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
ReleaseNotes _Mythic22 Version: 02 SOFTWARE Release Notes MYTHIC 22 VERSION V3.2.3 1 OBJET / OBJECT This document describes the software evolutions between V3.2.2 and V3.2.3 of the MYTHIC22. 2 REVUE ET APPROBATION — MISE EN APPLICATION / REVIEW AND APPROVAL Nom / Name Date / Date Visa / Signature [Approbation / Approval “to. Z proRouP reance Julien ALBERTI 2021-10-22 ‘Approbation / Approval CUSTOMER ‘ifappicable) a | [verification / Review Lydia LAUSSEL 2021-10-22 CE 3 HISTORIQUE DES MODIFICATIONS / REVISION HISTORY Version /|Date/Oate Auteur _/ [Raison et nature de la modification Version Author Reason and kind of modification 0: | 2021-08-12 /0.GENET | Creation 02 2021-10-06 |0. GENET Update following iteration 00S and 006 4 DIFFUSION / MISE A DISPOSITION This document is provided to the customer and all C2 people involved in the project. 5 TERMINOLOGIE ET DEFINITIONS / TERMINOLOGY AND DEFINITIONS N/A 6 REFERENCES / REFERENCES Fluidic Release Note : M22-ReleaseNoteFluid-CycV211-003 SRS_Mythic22 Rev34 ForReleaseNotes version 09 Page 1/3 ReleaseNotes _Mythic22 Version: 02 ‘SOFTWARE Release Notes MYTHIC 22 VERSION V3.2.3 DESCRIPTION GENERALE / GLOBAL DESCRIPTION OBJET / OBJECT. REVUE ET APPROBATION — MISE EN APPLICATION / REVIEW AND APPROVAL HISTORIQUE DES MODIFICATIONS / REVISION HISTORY .. see DIFFUSION / MISE A DISPOSITION TERMINOLOGIE ET DEFINITIONS / TERMINOLOGY AND DEFINITIONS REFERENCES / REFERENCES . vse DESCRIPTION GENERALE / GLOBAL DESCRIPTION... CONTRAINTES / CONSTRAINTS ..... FONCTIONNALITES AJOUTEES / NEW FEATURES... FINALISATIONS / COMPLETED ‘AMELIORATIONS / IMPROVEMENTS. CORRECTIONS / CORRECTIONS... BUGS CONNUS / KNOWN BUGS... 13.1 BUGS DEA CONNUS/ ALREADY KNOWN BUGS. 13.2 BUGS TROUVES/ FOUND BUGS ForReleaseNotes version 09 Page 23 ReleaseNotes _Mythic22 Version: 02 MYTHIC 22 SOFTWARE Release Notes | = BIT VERSION V3.2.3 8 CONTRAINTES / CONSTRAINTS Downgrade to previous version: NO. This version is released as V3.2.3-006 This software version must be installed only onto M22 CPU board with SN "213-XXXXXX”. This software must not be installed on previous M22 hardware. 9 FONCTIONNALITES AJOUTEES / NEW FEATURES [11616] CRC of fluidics cycles module is now managed. [11721] Autoclean setting max value is now 40 cycles. [10604] For all reagent the Almost Empty trigger limit is set to 35 runs (previous was 10). [22081] For Cleaner only the Almost empty trigger limit is set to 60 runs [12157] RDW-SD default values are forced for Standard type: * Calibration factor = 0.971 (previous = 1) * Normal high reference range RDW-SD h = 47.8 (previous = 46) Ifthe other types need to be updated, the user must press INIT. STD. button or enter it manually. 10 FINALISATIONS / COMPLETED Implementation of the new fluidic cycle module V211-003 and new reagents consumptions. (cf. M22- ReleaseNotefluid-CycV211-003 documentation) 11 AMELIORATIONS / IMPROVEMENTS [10710] If an error occurred during a Shutdown, the system does not power off anymore. 12 CORRECTIONS / CORRECTIONS [21578] Park Syringe motor position updated from-200 half steps to-75 half steps. This allowed the use of the new sampling piston with welded cylinders. [11724] On Login screen, the ENTER button on the physical keyboard can only validate field edition and confirm the log-in action. 13 BUGS CONNUS / KNOWN BUGS 13.1 BUGS DEJA CONNUS/ ALREADY KNOWN BUGS [2264] Printing on a C62 generates one to two blank pages. This will not affect results or user security nor data safety, loss of pages and printer is obsolete. [2883] When loading a batch QC or CAL! for another instrument, the file is read, but all fields are set to 0. This will not affect results or user security nor data safety, need to reenter values. 13.2 BUGS TROUVES/ FOUND BUGS NA ForReleaseNotes version 09 Page 3/3

You might also like