0% found this document useful (0 votes)
69 views8 pages

Sie CM Pac 3200 Meter Brochure

The PAC3200 is a compact power meter designed for reliable monitoring of electrical tariffs in industrial, government, and commercial applications. It supports various communication protocols for easy integration into monitoring systems and provides accurate measurements of over 50 electrical parameters. The device is suitable for applications such as cost allocation, energy monitoring, and automation integration, making it ideal for reducing power costs and improving energy efficiency.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views8 pages

Sie CM Pac 3200 Meter Brochure

The PAC3200 is a compact power meter designed for reliable monitoring of electrical tariffs in industrial, government, and commercial applications. It supports various communication protocols for easy integration into monitoring systems and provides accurate measurements of over 50 electrical parameters. The device is suitable for applications such as cost allocation, energy monitoring, and automation integration, making it ideal for reducing power costs and improving energy efficiency.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

PAC3200

Power Meter
Reliable and precise monitoring of electrical tariffs. The PAC3200 can also be used to support
power systems LEED certification and provide the needed energy
metering data for federal/local government energy
The PAC3200 is a powerful compact power monitoring reduction programs.
device that is suitable for use in industrial, government The PAC3200 provides open communications using
and commercial applications where basic metering and Modbus RTU/TCP, PROFINET and PROFIBUS-DP protocols
energy monitoring is required. The meter may be used for easy integration into any local or remote monitoring
as a stand alone device monitoring over 50 parameters system. Simple configuration of the meter can be done
or as part of an industrial control, building automation from the front display or by using a PC with SENTRON
or global power monitoring system. powerconfig setup software, supplied with the meter.
Metering and monitoring applications range from simple
analog volt and amp meter replacements to stand-alone
sub billing or cost allocation installations with multiple

usa.siemens.com/pds
96
mm
3.78
in.

96 mm
3.78 in.
Full Graphic LCD Display to indicate: Example of operating menu:
• Display title or designation of the The texts can be displayed in several languages, which can
displayed measurements be selected directly on the device.1) The large graphic LCD
• Phase display facilitates reading even from a distance. For optimum
• Measured value Unit visibility even in poor light conditions the PAC3200 comes
• Labeling of function keys with a gradually adjustable background illumination.

When, where and how much PAC3200 makes consumption apparent


To accomplish a sustainable reduction of
power costs, you must first analyze the
power is consumed? electrical system’s current consumption and
power flows. The PAC3200 power meter
precisely and reliably delivers the required
information of power values to put you
on the path to reduce your power cost.

Applications summary
 Replace multiple analog meters
An ideal replacement for analog meters.
Use it for stand-alone metering in
custom panels, switchboards,
switchgear, gensets, motor control
center and UPS systems, PDU, RPPs, etc.

 Basic Metering
The PAC3200 offers high-accuracy power,
energy and demand measurements.

2
Modbus TCP integrated 1 DI and 1 DO for
into the meter as standard remote switching,
and DI also
for kWh, kVAh,
• kvarh pulse
PAC3200 PROFIBUS
DP, MODBUS RTU,
• measurement
PROFINET and
In / Idiff, analog
expansion modules
for remote data
transmission.



Terminal blocks
for voltage and current measuring,
control power (available with
compression terminals)

 Cost allocation / Energy monitoring Power management and PAC3200


Perfect for monitoring right down to The PAC3200 can easily be integrated
the tool level, the meter can help into a power management system using
monitor cost centers, identify Modbus TCP (standard), Modbus RTU
opportunities for demand control and (option), PROFINET (option) or PROFIBUS.
check energy consumption patterns. With communication, the PAC3200
transmits measured values to the
 Automation integration supervisory systems, where the data
Monitor critical equipment processes can be further processed for display
and tie directly to the Siemens family and control.
of PLCs and automation networks.
Siemens offers a low cost Powermanager
 Sub-metering or enterprise level WinPM.Net power
Low cost, high accuracy and monitoring software which can provide
simple retrofit installation enables easy integration to the PAC3200 meter.
economical measurement of Powermanager or WinPM.Net provide
commercial and residential tenant standard overview displays allowing
space. Integrate the PAC3200 with detailed analysis of the electrical power,
existing energy management which allows for easy allocation of power
systems and RTUs. Reduce energy consumption and cost. Additionally,
consumption by eliminating unexpected operating conditions can
previously uncontrolled expenses. be detected on a timely basis.

These revenue accurate values can be 1) Languages included as standard in the


used for bill verification, monitoring meter are English, German, French, Spanish,
Italian, Portuguese, Polish, Turkish, Russian
backup power on critical systems and
and Chinese.
offering cost-effective energy solutions.

3
Functional features
Instantaneous values
Voltage Phase-phase / phase-neutral P
Currents Per phase P
Apparent, active and reactive power Per phase and total P
Power factor Per phase and total P
Frequency 45...64 Hz P
THD for voltage and current Per phase P
Min. / max. values Voltage – phase-phase, phase-neutral P
Current / Power / Power factor / THD per phase
Frequency
Three phase average voltage and current
Average values Voltage – phase-phase, phase-neutral P
Voltage min. / max. for phase-phase-phase-neutral
Current
Current min. / max.
Energy measurement
Active energy Import / export; high / low tariff P/P
Reactive energy Positive / negative; high / low tariff P/P
Apparent energy High / low tariff P
Energy demand per measuring period Three phase average rating for active and reactive power 1 to 60 min.
Min. / max. rating values within P
the measuring period
Meter running counter Uptime in hours P
Universal counter Pulse counting of external devices like water, gas, etc. P
Measurement accuracy
Voltages ±0.3%
Currents ±0.2%
Power factor and power ±0.5%
Active energy Class 0.5S in acc.
with IEC 62053-22 /
ANSI 12.20 class 0.5
Reactive energy Class 2 according to IEC61557-12
and/or IEC62053-23
Monitoring functions
Set point monitoring V, I, power, VAR, VA, Freq. THD, PF Up to 6 values
Simple logic functions for alarming Alarm via digital Output or software
Phase unbalance Voltage and / or >< current P
Communication
Ethernet Integrated 10 Base-T (10 Mbit/sec)
Modbus TCP Integrated RJ45 port 10 Base-T (10 Mbit/sec)
PROFIBUS DP expansion module Optional • Support of all baud rates from
• Parameterization via device front 9600 BPS to 12 MBPS (9.6 Kbit/
or with SENTRON powerconfig sec to 12 Mbit/sec)
software
• Transition of data via GSD file
Modbus RTU expansion module Optional
• Parameterization via device front • Support of all baud rates of
or with SENTRON powerconfig 4800, 9600, 19.2K and 38.4K
software BPS (4.8 / 9.6 / 19.2 and
• Transition of data via MODBUS 38.4 kB/sec
register based points
Switched Ethernet Expansion Module Optional
(Supports PROFINET and Dual RJ45 • Parameterizatio via device front • Support of 10 and 100 Mbit/s
Ethernet Ports) or with powerconfig software baud rates
• Transition of data via GSDML file

4
Functional features (continued)
Inputs / Outputs
Input voltage / at digital input
• initial value for signal<1>-recognition 13 V
• at DC / rated value 24 V
• Full-scale value for signal <0> recognition 8V
Number of digital outputs 1
Number of digital inputs 1
Digital output version Switching or pulse output function
Input current / at digital input
• for signal <1> 7 mA
Output current
• at digital output / with signal < 0 > / maximum 0.2 mA
• at digital output / for signal < 1 > / minimum 27 mA
• at digital output / for signal < 1> / maximum 27 mA
• at the digital outputs / at DC / maximum 100 mA
Output delay / at digital output
• for signal < 0 > to < 1 > / maximum 5 ms
• for signal < 1> to < 0 > / maximum 5 ms
Operating voltage / as output voltage / at DC /
maximum permissible 30 V
Property of the output / Short-circuit proof Yes
Input delay time / at digital input
• for signal < 0 > to < 1 > / maximum 5 ms
• for signal < 1> to < 0 > / maximum 5 ms
Internal resistance / at the digital outputs 55 Ω
Measuring category / for digital signals CATII
Switching frequency / at digital output / maximum 17 Hz
Measuring inputs
Outer conductors and neutral conductors internal resistance / 1.05 MΩ
for voltage measurement
Measurable supply voltage
• between (PE)N and L / at AC / minimum 40 V
• between (PE)N and L / at AC / maximum 480 V
• between (PE)N and L / at AC / maximum rated value 400 V
• between the outer conductors / at AC / minimum 70 V
• between the outer conductors / at AC / maximum 831 V
• between the outer conductors / at AC / maximum rated value 690 V
Voltage measuring range extension / with external voltage transformers Yes
Current measuring range extension / with external current transformers Yes
Measuring category / for voltage measurement CATIII
Supply voltage / between the outer conductors / at AC / 831 V
maximum permissible
Consumed active power / for current measurement / per phase 115 mW
Continuous current / at AC / maximum permissible 10A
Measuring category / for current measurement CATIII
Zero suppresion / for current measurement 0.1...10 %
Relative measurable current / at AC
• minimum 1%
• maximum 120 %
Measuring procedure / for current measurement TRMS
Measurable current / 1 / at AC / Rated value 1A
Short-time current resistance (Icw) / limited to 1 s / rated value 100 A

5
Functional features (continued)
Standard inputs / outputs
Integrated digital input 24 Vdc / 7 mA 1, dry contact, requires external power
Integrated digital output 30 Vdc max. / 10-27 mA; 100 mA max. 1
General
Password protection P
Technical data
Two-quadrant (import) / 4Q
four-quadrant (import
and export) measuring
Measurement types 1 ph, 2 ph or 3 ph
Applicable for network type TN, TT, IT
Sampling rate 64 samples / cycle at 60Hz
Measured voltage Direct connection up to max. delta/wye 690 V / 400 V (CAT III)
without transformer
Current inputs Settable on device 1A or 5A nominal
Power supply AC/DC 95...240V AC (±10%) /
110...340V DC (±10%)
DC only 22...65V DC (=±10%)
Degree of protection Front IP65, for UL IP54
Rear IP20, NEMA 1A
Operating temperature ºC / ºF –10...+55 / +14...+131
Display Type Background-illuminated
graphic LCD
Resolution (pixels) 128 x 96
Text displays Multilingual
Optional ports 1 One port is available for optional modules
MTBF 185.8 Years
Connections
Type of electrical connection
• at the measurement inputs for voltage screw-type terminals
• of the fast Ethernet interface RJ45 (8P8C)
Mechanical Design
Height 96 mm
Height / of the display 54 mm
Width 96 mm
Width
• of the display 72 mm
Depth 56 mm
Mounting position vertical
Installation depth 51 mm
Mounting type / panel mounting Yes
Net weight 451 g
Environmental conditions
Installation altitude / at height above sea 2 000 m
level / maximum

6
Function features (continued)
Standard
• for EMC for industrial sector IEC 61000-6-2 respectively IEC 61326-1:2005, table 2
• for EMC against unloading IEC 61000-4-2: 2001-04
• for EMC against high frequency fields IEC 61000-4-3: 2006-02
• for EMC against conducted LF disturbance IEC 61000-6-4, Group 1 Klasse A / CISPR11 Gruppe 1 Klasse A FCC
variables (industry) Part 15 Subpart B Class A
• for EMC against conducted disturbance variables IEC 61000-4-6: 2001-12
via HF fields
• for EMC against magnetic fields with power
engineering frequencies IEC 61000-4-8: 2001-03
• for EMC against quick, transient electrical disturbances IEC 61000-4-4: 2005-07
• for EMC against voltage drops and interruptions IEC 61000-4-11: 2004-03
• for EMC against surge voltages IEC 61000-4-5: 2001-12
• for free fall IEC 60068-2-32: 1975
• for pulse emitter according to IEC62053-31
• for cyclic, environmental damp heat check IEC 60068-2-30
• for environmental coldness check IEC 60068-2-1
• for environmental dry heat check IEC 60068-2-2
Relative humidity / at 25 °C / without condensation /
during operation
• minimum 5%
• maximum 95 %
Ambient temperature
• during operation / minimum -10 °C
• during operation / maximum 55 °C
• during storage / minimum -25 °C
• during storage / maximum 70 °C
Certificates
Certificate of suitability
• as EC declaration of conformity IEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and
DIN EN 61010-1:2002 with “Berichtigung 1”
• as approval for Canada UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04
• as approval for USA UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04
Reference identifier / acc. to DIN EN 61346-2 P

General Product Approval Declaration of Conformity

Order information
Product Order Number1)
PAC3200 compression terminals not suitable for use with ring tongue terminals, AC/DC 7KM2112-0BA00-3AA0
PAC3200 compression terminals not suitable for use with ring tongue terminals, DC only for 22-65V DC 7KM2111-1BA00-3AA0
extra low voltage power supply
PAC PROFIBUS DP expansion module 7KM9300-0AB01-0AA0
PAC MODBUS RTU expansion module 7KM9300-0AM00-0AA0
Adapter Plate for 4700/4720 meter cutout 93-47ADAPTER
SITOP Power Supply AC 99-264VAC, 24 VDC, 0.5A 6EP1331-5BA00
PAC3200 In / Idiff, analog expansion module 7KM9200-0AD00-0AA0
1) Omit dashes from part numbers when ordering except on 93-47ADAPTER.

7
Published by
Siemens Industry, Inc. 2018.

Siemens Industry, Inc.


5400 Triangle Parkway
Norcross, GA 30092

For more information, please contact


our Customer Support Center.
Phone: 1-800-333-7421
E-mail: [email protected]

usa.siemens.com/pds

Order No.: PCPM-P3200-0418


Printed in U.S.A.
© 2018 Siemens Industry, Inc.

The technical data presented in this document is based on an actual case


or on as-designed parameters, and therefore should not be relied upon for
any specific application and does not constitute a performance guarantee
for any projects. Actual results are dependent on variable conditions.
Accordingly, Siemens does not make representations, warranties, or
assurances as to the accuracy, currency or completeness of the content
contained herein. If requested, we will provide specific technical data or
specifications with respect to any customer’s particular applications. Our
company is constantly involved in engineering and development. For that
reason, we reserve the right to modify, at any time, the technology and
product specifications contained herein.