Datasheet 08170436 01 2.02 E - 133583470
Datasheet 08170436 01 2.02 E - 133583470
08170436-01 - 2.02
* BP 1 : BP1
Tolerances dependent on class of accuracy in accordance to DIN 24166 in range of efficiency class of accuracy 1 2 3
η >= 0,9 x ηmax.. Coordination for class of accuracy (G.Kl.) see product specification. Δpt und V1 [ %] +/- 2,5 +/- 5 +/- 10
At any rate, please pay attention to the techn. indications made in our Handbook of fans. PW [ %] +3 +8 + 16
pressure units : 1 daPa = 10 Pa = 10 N/m² = 0,1 mbar = 1,0197 mmWC Lw und Lp [dB] +3 +4 +6
quotation item
08170436-01 - 2.02
housing data
impeller data
boundary conditions
design temperature tB 20 °C
max. opertaing temperature tmax 80 °C
max.impeller speed nVmax 3127 1/min
inlet speed c1 28.8 m/s
inlet speed AK c1' - m/s
outlet speed c2 27.9 m/s
outlet speed DIF c2' - m/s
Tolerances dependent on class of accuracy in accordance to DIN 24166 in range of efficiency class of accuracy 1 2 3
η >= 0,9 x ηmax.. Coordination for class of accuracy (G.Kl.) see product specification. Δpt und V1 [ %] +/- 2,5 +/- 5 +/- 10
At any rate, please pay attention to the techn. indications made in our Handbook of fans. PW [ %] +3 +8 + 16
pressure units : 1 daPa = 10 Pa = 10 N/m² = 0,1 mbar = 1,0197 mmWC Lw und Lp [dB] +3 +4 +6
quotation item
08170436-01 - 2.02
FAN CHARACTERISTIC CURVE designation
MXE
Liste 17_1 80Grad date
5/2/2018 / yws
fan type FK serial no. comm. no.
MXE045-026530-00 -
your order no. type of control codeword
- valve -
pressure increase in daPa
550
500
450
OP1
400
350
300
250
200
Δp stat
150 Δp tot
100
50
0
0 50 100 150 200 250 300 350 400 450
volume flow V1 In m³/min
power requirement PW in kW efficiency in %
30 100
PW 90
25 OP1
80
70
20
60
15 50
η tot 40
10
30
20
5
10
0 0
0 50 100 150 200 250 300 350 400 450
volume flow V1 In m³/min
NP OP 1 OP 2 OP 3 OP 4 OP 5 OP 6
volume flow V1 m³/min 275
total pressure increase Δpt daPa 421
density at inlet ρ1 kg/m³ 1.157
impeller speed nI rpm 2950
inletguidevane/damp.
Tolerances dependent on class of accuracy in accordance to DIN 24166 in range of efficiency class of accuracy 1 2 3
η >= 0,9 x ηmax.. Coordination for class of accuracy (G.Kl.) see product specification. Δpt und V1 [ %] +/- 2,5 +/- 5 +/- 10
At any rate, please pay attention to the techn. indications made in our Handbook of fans. PW [ %] +3 +8 + 16
pressure units : 1 daPa = 10 Pa = 10 N/m² = 0,1 mbar = 1,0197 mmWC Lw und Lp [dB] +3 +4 +6
quotation item
08170436-01 - 2.02
Start-up data
rated output motor torque 145.0 Nm
torque Υ 94.0 Nm
torque Δ 348.0 Nm
load torque in NP 80.1 Nm
load torque closed damper 40.0 Nm
moment of inertia relative to nM 2.4 kgm²
start-up time in NP Υ 12.2 s
start-up time closed damper Υ 9.7 s
start-up time in NP Δ 2.4 s
start-up time closed damper Δ 2.3 s
theoretical starting time 3.1 s
Drive power is sufficient. Please take into consideration the start-up times depending on the starting type Δ-
or YΔ of the motor. Have the start-up behaviour checked and approved by the motor producer if a certain
number of cold start-ups or restarts are required
Tolerances dependent on class of accuracy in accordance to DIN 24166 in range of efficiency class of accuracy 1 2 3
η >= 0,9 x ηmax.. Coordination for class of accuracy (G.Kl.) see product specification. Δpt und V1 [ %] +/- 2,5 +/- 5 +/- 10
At any rate, please pay attention to the techn. indications made in our Handbook of fans. PW [ %] +3 +8 + 16
pressure units : 1 daPa = 10 Pa = 10 N/m² = 0,1 mbar = 1,0197 mmWC Lw und Lp [dB] +3 +4 +6