EC1620-Key-Function-V06
EC1620-Key-Function-V06
Because the product features more, please read this manual carefully, thank you for your cooperation!
Function introduction:
Real time voice: voice timekeeping,Time can be set Chinese or English, set the volume.
Digital tube display:On the electric silence that time, temperature, year, month, day, week round display, through the button
can be set to display only time or display the time and temperature (in the "time display settings").
LED Display:There are 12 kinds of display, can close the display can be displayed through the button switch. Also can set the
button to automatically switch the display (in the "LED automatic switch setting display mode" setting), when the LED switch
display parameter x is less than 60, switch the display time is x*1 minutes, when more than 60, switch the display time for (X-60)
*60 minutes, when x=0 does not automatically switch display.
Time Setting:Can be set time by key .
Hourly Chime : Can be open or closed, can set the time period by button (for example, can be set to 8 in the morning to 22
o'clock in the evening time, the other time is not hourly chime).
Alarm:There are 4 alarm clock, can be turned off or on, can be set the length of alarm time and alarm rings.
The first alarm clock for ordinary, when opened will be alarm every day.
The second alarm clock for the workday, when open every Monday to Friday alarm, Saturday and Sunday no alarm.
The Third alarm clock for the weekend, when open Saturday and Sunday alarm, Monday to Friday no alarm.
The fourth is a single alarm clock, when open only alarm one times.
Ring: output music with speakers.Can change their own ring, can be set to alarm bells.
Temperature Display:Measuring ambient temperature with thermistor.The default is the degree Celsius display, can be set by
the key to Fahrenheit display.When the temperature is not allowed to do when the temperature calibration (in the "temperature
calibration settings") (for example: when the display temperature is 3 degrees higher than the actual temperature, the
temperature calibration value can be set to -3).
Light Control:Measurement of ambient brightness with photosensitive resistors.When the ambient light becomes dark, it will
automatically reduce the brightness of the clock.There are three level of brightness.
12/24 hour system:The default is 24 hours, can be set by the button for the display of 12 hours (in the "12/24 hours set mode").
Brightness adjustment: can set the digital tube and LED brightness.
Some errors in welding:
1、Clock chip (DS3231) no welding or welding error. Show "Eor1".
2、Thermistor (temperature measurement circuit) no welding or welding error. Show "Eor2".
3、Photosensitive resistor (metering circuit) without welding or welding error. Show "Eor3".
Electrical performance:
Power supply: DC5V
Working current: <250MA
Alarm current: <500mA
Electronic clock display and key function
Time display:
Display description MODE key function in mode PLUS key function in mode
1, to tell the time.
1, short press, enter the time
There are 3 display modes: 1, 2, fixed time display mode, the first round
setting mode.
Time display time, temperature, year, of temperature, year, month, day, week.
2, long press 3 seconds into the
mode (power month, day, week round 3, Hold down the MODE key and then
hourly chime and alarm
on default display. 2, time, temperature press the PLUS key to switch LED display
settings.
mode) wheel display. 3, only display style (a total of 12 display styles), and can
3, Long press 5 seconds to enter
time. turn off the LED display (digital display
the function settings.
only).
Time Setting:
It can modify the time of the clock, in each setting if more than 10 seconds without any key press, then automatically returns the
time display, and restore the time before.
Mode Display description PLUS key function in mode MODE key function in mode
Time display mode Short press enter (year set mode)
Four digital tube flashing shows Set “Year”, long press can
Year Set Mode Into next mode (Month set mode)
“Year” quickly set
front two tube flashing shows
Set “Month”, long press can
Month Set Mode “Month”, after two tube always Into next mode (Day set mode)
quickly set
shows “Day”
Front two tube always shows
Set “Day”, long press can
Day Set Mode “Month”, after two tube flashing Into next mode (Hour set mode)
quickly set
shows “Day”
Front two tube flashing shows
“Hour”, after two tube always
Set “Hour”, long press can
Hour Set Mode shows “H” when 24 hour system, Into next mode (Minute set mode)
quickly set
when 12 hour system shows ”A” in
am, shows “P” in pm.
Front two tube always shows
Set “Minute”, long press can
Minute Set Mode “Hour”, after two tube flashing Into next mode (Second set mode)
quickly set
shows “Minute”
If there is a time to adjust, save the
Front two tube always shows “--”,
Set “Second”, long press can settings, otherwise not save the
Second Set Mode after two tube flashing shows
quickly set settings, and return time display
“Second”
mode.
Function Setting:
each setting mode, press the MODE button for 3 seconds or 10 seconds without any button is pressed, will automatically return
time display mode.
Mode Display description PLUS key function in mode MODE key function in mode
Press the MODE button
Time Display Mode
above 5 seconds to enter
(Volume Setting Mode)
The first tube always shows “1 ”,
Volume Setting Into next mode (light control
after two tube flashing shows Set volume
Mode switch mode)
volume value
The first tube always shows “2 ”,
Into next mode (Fahrenheit
Light Control Switch after two tube flashing shows
open or close the light control temperature display switch
mode “ON” or “OF” express open or
setting mode)
close the light control
The first tube always shows “3 ”,
Fahrenheit after two tube flashing shows Into next mode
Temperature Display “ON” or “OF” express Set Fahrenheit or Centigrade display (temperature calibration
Switch Settings Fahrenheit or Centigrade setting mode)
display
Set temperature calibration value,
Range from -9 to 10.(For example,
Temperature The first tube always shows “4 ”,
when the display temperature is 3 Into next mode (12/24 hour
Calibration Setting after two tube flashing shows
degrees higher than the actual display setting mode)
Mode temperature calibration value
temperature, the calibration value
can be set to -3).
The first tube always shows “5 ”,
12/24 Hour Display after two tube flashing shows Into next mode (time display
Set 12/24 hour display
Setting Mode “ON” or “OF” express 12 hour setting mode)
or 24 hour display
Set round display mode (have 3
The first tube always shows “6 ”, kinds),0: only display time. 1: time,
Time Display Setting Into next mode (LED auto
after two tube flashing shows temperature, year, month, day, week
Mode switch display setting mode)
round display mode round display. 3: time and
temperature round display.
Set LED auto switch value (0 for fixed
display). For example, when set to
The first tube always shows “7 ”, 30, switch to the next display every
LED Auto Switch Into next mode (Digital tube
after two tube flashing shows 30 minutes. When set to 62 (greater
Display Setting Mode brightness setting mode)
LED auto switch value than 60), each (62-60) *60 minutes
(i.e., 2 hours) is switched to the next
display.
The first tube always shows “8 ”,
Digital tube Into next mode (LED
after two tube flashing shows Set digital tube brightness
brightness Setting brightness setting mode)
digital tube brightness
The first tube always shows “9 ”,
LED Brightness
after two tube flashing shows Set LED brightness return time display mode.
Setting
LED brightness