0% found this document useful (0 votes)
18 views5 pages

SCHEDULE-OF-LOADS_CORDOVA

The document outlines the electrical specifications for a two-storey family dwelling, detailing the lighting and power panel loads for both the ground and second floors. It includes information on circuit ratings, equipment grounding, wire sizes, and distances for various electrical appliances and fixtures. The total load for the ground floor is 49,776 VA, with specific circuit requirements and protective device ratings provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views5 pages

SCHEDULE-OF-LOADS_CORDOVA

The document outlines the electrical specifications for a two-storey family dwelling, detailing the lighting and power panel loads for both the ground and second floors. It includes information on circuit ratings, equipment grounding, wire sizes, and distances for various electrical appliances and fixtures. The total load for the ground floor is 49,776 VA, with specific circuit requirements and protective device ratings provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

LIGHTING AND POWER PANEL 1 (GROUND FLOOR)

CKT. LOAD DESCRIPTION QTY. VOLT- SWITCHES RATED OCPD SIZE & TYPE OF EQPT. GROUNDING SIZE & TYPE OF DISTANCES OF
PER EVERY
NO. (RATING) CKT. AMPERE S1 S2 S3 S3W VOLT AMP AT AF P Cu WIRE CONDUCTOR CONDUIT CONDUIT
L.O. (100 VA) 36 3,600 - - - - 230 15.65 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 143.59 ft.
1
L.O. (100 VA) 20 2,000 - - - - 230 8.7 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 264.62 ft.
2
DUPLEX C.O. (180 VA) 8 1,440 - - - - 230 6.26 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 40.33 ft.
3
DUPLEX C.O. (180 VA) 8 1,440 - - - - 230 6.26 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 38.78 ft.
4
DUPLEX C.O. (180 VA) 8 1,440 - - - - 230 6.26 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 58.52 ft.
5
DUPLEX C.O. (180 VA) 7 1,260 - - - - 230 5.48 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 37.93 ft.
6

7 WALL MOUNTED ACU (1 HP) - Living Room 1 1,840 - - - - 230 8x2 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 24.94 ft.

8 WALL MOUNTED ACU (0.50 HP) - Study area 1 1,127 - - - - 230 4.9 x 2 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 30.94 ft.

9 WALL MOUNTED ACU (0.75 HP) - Kitchen 1 1,587 - - - - 230 6.9 x 2 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 6.10 ft.

10 WALL MOUNTED ACU (0.50 HP) - Dining Room 1 1,127 - - - - 230 4.9 x 2 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 27.42 ft.

11 REFRIGERATOR 1 1,500 - - - - 230 6.52 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 15.75 ft.

WASHING MACHINE (1.5 kW) 1 1,500 - - - - 230 6.52 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 15.72 ft.
12
MICRO WAVE OVEN (1.5 kW) 1 1,500 - - - - 230 6.52 20 400 2 2 - 3.5 mm² THW 1 - 5.5 mm² THW 16 mm∅ Rigid PVC 12.29 ft.
13

14 DRILL PRESS (1/3 HP) 1 828 - - - - 230 3.6 x 2.5 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 10.70 ft.

15 BENCH GRINDER (1/2 HP) 1 1,127 - - - - 230 4.9 x 2.5 20 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 13.60 ft.

16 WATER PUMP (1.5 HP) 1 2,300 - - - - 230 10 x 2.5 25 400 2 2 - 3.5 mm² THW 1 - 3.5 mm² THW 16 mm∅ Rigid PVC 66.28 ft.

17 CLOTHES DRYER (5 kW) 1 5,000 - - - - 230 21.74 30 400 2 2 - 5.5 mm² THW 1 - 5.5 mm² THW 16 mm∅ Rigid PVC 15.72 ft.

18 WATER HEATER (5 kW) - Common T&B 1 5,000 - - - - 230 21.74 30 400 2 2 - 5.5 mm² THW 1 - 5.5 mm² THW 16 mm∅ Rigid PVC 14.96 ft.

20 AIR COMPRESSOR (2 HP) 1 2,760 - - - - 230 12 x 2 30 400 2 2 - 5.5 mm² THW 1 - 5.5 mm² THW 16 mm∅ Rigid PVC 23.34 ft.

ELECTRIC RANGE (8 kW) 1 8,000 - - - - 230 34.78 45 400 2 2 - 8.0 mm² THW 1 - 5.5 mm² THW 21 mm∅ Rigid PVC 7.06 ft.
21
WELDING MACHINE (3.4 KVA) 1 3,400 - - - - 230 14.78 x 3 45 400 2 2 - 14 mm² THW 1 - 5.5 mm² THW 27 mm∅ Rigid PVC 7.61 ft.
22

49,776

A. AMPACITY OF SUB-FEEDER CONDUCTOR (Ground Floor) = 25% ( HML ) +Total Load ×85 % DF
PROFESSIONAL ELECTRICAL ENGINEER:
230 V
PROPOSED ELECTRICAL PLAN OF A TWO STOREY FAMILY DWELLING
PROJECT NAME =
25% (2,760 VA) + 49,776 VA × 85% DF BY: ENGR. EDWING ESPINAS
CHECKED

DESIGNED BY: MR. JANSSEN G. CORDOVA


230 V
PINAGSABANGAN 1, NAUJAN ORIENTAL MINDORO
PROJECT LOCATION PRC NO: TIN NO:

PTR NO: DATE ISSUED:

MR. JANSSEN G. CORDOVA


OWNER FAX NO. REG NO:
• Use 2 - 100 mm² THW Cu Wires @220 A
1 - 22 mm² THW Cu Wire for EGC

B. MAXIMUM CURRENT RATING OF


PROTECTIVE DEVICE C. CIRCUIT REQUIREMENTS D. SERVICE EQUIPMENT RATING
• Use 1 - 225 AT, 400 AF, 2-Pole, 240
➤ For Inverse Time Circuit Breaker • Use Fifteen (15) 20 A - 2 Wire BCB V MCCB
For Ground Floor's Main Circuit
• Use One (1) 25 A - 2 Wire BCB Breaker
• Use Three (3) 30 A - 2 Wire BCB
• Use Two (2) 45 A - 2 Wire BCB

PROFESSIONAL ELECTRICAL ENGINEER:


PROPOSED ELECTRICAL PLAN OF A TWO STOREY FAMILY DWELLING
PROJECT NAME
CHECKED BY: ENGR. EDWING ESPINAS

DESIGNED BY: MR. JANSSEN G. CORDOVA


PINAGSABANGAN 1, NAUJAN ORIENTAL MINDORO
PROJECT LOCATION PRC NO: TIN NO:

PTR NO: DATE ISSUED:

MR. JANSSEN G. CORDOVA


OWNER FAX NO. REG NO:
LIGHTING AND POWER PANEL 2 (SECOND FLOOR)
OCP DISTANCES
CKT. LOAD DESCRIPTION QTY. VOLT- SWITCHES RATED D SIZE & TYPE OF EQPT. GROUNDING SIZE & TYPE OF OF
PER EVERY
NO. (RATING) CKT. AMPERE S1 S2 S3 S3W VOLT AMP AT AF P Cu WIRE CONDUCTOR CONDUIT CONDUIT
16 mm∅ Rigid
L.O. (100 VA) 36 3,600 - - - - 230 15.65 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 201.52 ft.
1 PVC
16 mm∅ Rigid
DUPLEX C.O. (180 VA) 9 1,620 - - - - 230 7.04 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 58.29 ft.
2 PVC
16 mm∅ Rigid
DUPLEX C.O. (180 VA) 9 1,620 - - - - 230 7.04 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 47.39 ft.
3 PVC
16 mm∅ Rigid
DUPLEX C.O. (180 VA) 9 1,620 - - - - 230 7.04 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 42.84 ft.
4 PVC
16 mm∅ Rigid
DUPLEX C.O. (180 VA) 8 1,440 - - - - 230 6.26 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 42.82 ft.
5 PVC
16 mm∅ Rigid
DUPLEX C.O. (180 VA) 8 1,440 - - - - 230 6.26 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 37.28 ft.
6 PVC
16 mm∅ Rigid
WALL MOUNTED ACU (1 HP) - Master's Bedroom 1 1,840 - - - - 230 8x2 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 22.17 ft.
7 PVC
16 mm∅ Rigid
WALL MOUNTED ACU (1 HP) - Guest Room 1 1,840 - - - - 230 8x2 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 5.51 ft.
8 PVC
16 mm∅ Rigid
WALL MOUNTED ACU (1 HP) - Bedroom 1 1 1,840 - - - - 230 8x2 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 41.21 ft.
9 PVC
16 mm∅ Rigid
WALL MOUNTED ACU (1 HP) - Bedroom 2 1 1,840 - - - - 230 8x2 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 26.53 ft.
10 PVC
16 mm∅ Rigid
WALL MOUNTED ACU (1 HP) - Bedroom 3 1 1,840 - - - - 230 8x2 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 69.53 ft.
11 PVC
4.9 x 16 mm∅ Rigid
WALL MOUNTED ACU (0.50 HP) - Game Room 1 1,127 - - - - 230 20 250 2 2- 3.5 mm² THW 1 - 3.5 mm² THW 9.13 ft.
12 2 PVC
16 mm∅ Rigid
WATER HEATER (5 kW) - Common T&B 1 5,000 - - - - 230 21.74 30 250 2 2- 5.5 mm² THW 1 - 5.5 mm² THW 22.88 ft.
13 PVC
16 mm∅ Rigid
WATER HEATER (5 kW) - Master's Bedroom 1 5,000 - - - - 230 21.74 30 250 2 2- 5.5 mm² THW 1 - 5.5 mm² THW 14.15 ft.
14 PVC
16 mm∅ Rigid
WATER HEATER (5 kW) - Guest Room 1 5,000 - - - - 230 21.74 30 250 2 2- 5.5 mm² THW 1 - 5.5 mm² THW 11.40 ft.
15 PVC

36,667

PROFESSIONAL ELECTRICAL ENGINEER:


PROPOSED ELECTRICAL PLAN OF A TWO STOREY FAMILY DWELLING
PROJECT NAME
CHECKED BY: ENGR. EDWING ESPINAS

DESIGNED BY: MR. JANSSEN G. CORDOVA


PINAGSABANGAN 1, NAUJAN ORIENTAL MINDORO
PROJECT LOCATION PRC NO: TIN NO:

PTR NO: DATE ISSUED:

MR. JANSSEN G. CORDOVA


OWNER FAX NO. REG NO:
25% ( HML ) +Total Load ×85 % DF
A. AMPACITY OF SUB-FEEDER CONDUCTOR (Second Floor) = 230 V
=
25% (2,300 VA) + 36,667 VA × 85% DF

138.01 A
230 V
=

• Use 2 - 80mm² THW Cu Wires @190 A

1 - 14mm² THW Cu Wire for EGC

B. MAXIMUM
CURRENT
RATING OF
PROTECTIVE
DEVICE C. CIRCUIT REQUIREMENTS D. SERVICE EQUIPMENT RATING

➤ For Inverse Time Circuit Breaker • Use Twelve (12) 20 A - 2 Wire BCB • Use 1 - 175 AT, 250 AF, 2-Pole, 240 V MCCB

• Use Three (3) 30 A - 2 Wire BCB For Second Floor's Main Circuit Breaker

CORDOVA, JANSSEN G.

PROFESSIONAL ELECTRICAL ENGINEER:


PROPOSED ELECTRICAL PLAN OF A TWO STOREY FAMILY DWELLING
PROJECT NAME
CHECKED BY: ENGR. EDWING ESPINAS

DESIGNED BY: MR. JANSSEN G. CORDOVA


PINAGSABANGAN 1, NAUJAN ORIENTAL MINDORO
PROJECT LOCATION PRC NO: TIN NO:

PTR NO: DATE ISSUED:

MR. JANSSEN G. CORDOVA


OWNER FAX NO. REG NO:
PROFESSIONAL ELECTRICAL ENGINEER:
PROPOSED ELECTRICAL PLAN OF A TWO STOREY FAMILY DWELLING
PROJECT NAME
CHECKED BY: ENGR. EDWING ESPINAS

DESIGNED BY: MR. JANSSEN G. CORDOVA


PINAGSABANGAN 1, NAUJAN ORIENTAL MINDORO
PROJECT LOCATION PRC NO: TIN NO:

PTR NO: DATE ISSUED:

MR. JANSSEN G. CORDOVA


OWNER FAX NO. REG NO:

You might also like