ACP-E04-Static
ACP-E04-Static
Table of Contents
Description .......................................... 1
Assumptions ......................................... 2
Model Information ................................. 2
Study Properties .................................... 3
Units ................................................. 3
Material Properties ................................ 4
Description Loads and Fixtures ................................. 6
Connector Definitions ............................. 6
Se realiza el análisis de carga de los estantes construidos
Mesh information ................................... 7
para almacenamiento de herramientas, repuestos y Resultant Forces ................................... 7
Model Information
Units
Unit system: SI (MKS)
Length/Displacement mm
Temperature Kelvin
Angular velocity Rad/sec
Pressure/Stress N/m^2
Resultant Forces
Components X Y Z Resultant
Reaction force(N) -0.00565338 6,920.13 -0.0477581 6,920.13
Reaction Moment(N.m) -0.000495192 -0.00139832 0.0053055 0.00550897
Entities: 8 face(s)
Type: Apply normal force
Value: 80 kgf
Force-1
Connector Definitions
No Data
Resultant Forces
Reaction forces
Selection set Units Sum X Sum Y Sum Z Resultant
Entire Model N -0.00565338 6,920.13 -0.0477581 6,920.13
Reaction Moments
Selection set Units Sum X Sum Y Sum Z Resultant
Entire Model N.m -0.000495192 -0.00139832 0.0053055 0.00550897
Conclusion
Se obtiene un factor de seguridad de 1.4 para una carga de 160 kgf por cada division del estante,
por lo tanto el diseño es aceptable.
38
3 E04-003 TRAVESAÑO C 1x1", e=1.5 mm 4
DETAIL A
410
25
E E
DETAIL B
SCALE 1 : 5 1
22
D 3 D
C C
2000
1528
1078
528
B 410 B
CONFIPETROL NEWMONT
ESTANTE A1