CNC-703CNCController
CNC-703CNCController
12345)
X+ Jog X+
X- Jog X-
Y+ Jog Y+, Increase feed rate when machining
Y- Jog Y-, Decrease feed rate when machining
Z+ Jog Z+, Increase spindle speed when machining
Z- Jog Z-, Decrease spindle speed when machining
XY->0 Set current X,Y position as X,Y origin
Z->0 Set current Z position as Z origin
HOME Motors run to home position
HIGH/LOW Select High or Low Speed for Jogging
ON/OFF Turn Spindle ON or OFF
ORIGIN/OK Run motors to 0,0,0 position
MODE Selects between Continuous, Step and Distance Modes
RUN/PAUSE Run a File from memory
STOP/CANCEL Adjust High and Low speed jogging speeds
MENU + Digit Switch working co-ordinates
MENU + ON/OFF C.A.D. Function (Auto Zero Z using CAD device)
MENU + MODE Change to/from 4th axis control
RUN/PAUSE + Digit Stop point process (Resume running from a breakpoint previously saved)
RUN/PAUSE + HIGH/LOW
Segment Process Run a portion of a file from one line to another
Multiple Process Repeat a file multiple times with a settable delay between repeats
Mill Table Mill the tabletop
Without analog Simulation mode, doesn't move motors
ORIGIN/OK + STOP/CANCEL Pressing this will bring up help information if it exists for that screen
MENU
Machine Setup
Pulse Equiv Set pulses/mm for each axis
Table Size Set table size in mm for each axis
Home Setup
Home Speed Homing Speed in mm/min
Home Direction Homing Direction
Spindle Setup
Input Spindle state number Enter number of states for the spindle speed 2-16
Lines State when spindle is off Select the S0-S3 outputs state for when the spindle is off
Line State of nth grade speed Select the S0-S3 outputs state for when the spindle is at n speed
Spindle Delay
Spindle delay,un Units are milliseconds
Voltage Setup
Input Volt Input High or Low Voltage Selection
Output Volt Output High or Low Voltage Selection
Spd Limit
X Speed Limit + and - Dir speed limits
Y Speed Limit + and - Dir speed limits
Z Speed Limit + and - Dir speed limits
C Speed Limit + and - Dir speed limits
C.A.D. Thickness
Cutter Adjust Device Thickness CAD Device Thickness
Screw Interspace
Screw Space X, Y, Z Backlash Compensation max 1mm
Auto Pro Setup
Linear Accl Linear Acceleration
Curv Accl Curve Acceleration
G Code Read Setup
Read F Disable/Enable F codes (Feed Rate)
Disp Err Disable/Enable display of file errors for correction
Keep Zup Force Z up at the end of the file or remain where the file left it
Read T Unsupported
Hold on Prohibited
Hold on Control Signal port with M211/M210 codes
Process Time Process the time a file will take before starting it or not
System Setup
Languages
Chinese
English
Function Configure
Do you need save PowerOff?
Language
Save Z adjusted value or not?
Is there Emergency Stop Sensor?
Is there Hard limit senseors?
It is in traditional manual mode?
T change setup
Toolcover
Dustcover
Whether a FT SW Foot Switch
Whether a protection switch Protective Cover
Trvl by the spd ratio control?
Filter cmds of JDPaint converted file?
What marked axis of rotation? Choose between A or C for the rotational Axis
Switch axis is rotation? Rotational or Linear axis?
Cutting off the power to restart.... Turn off the power and then turn it on again
Inner Format Format inner memory
Key Format Format usb key
Input Self Check Check the state of the inputs
Output Self Check Check the state of the outputs
Buttons Check Check the operation of the buttons
System Auto Update Update the system firmware
Advanced Pro Setup
Multiple Setup
Row Column Enter number of rows and columns
RowSpace ColumnSpace Enter row and column spacing
Pause Time Seconds to wait
Stop Setup
Stop Statue
Go Origin
Z up then Stop
Go Stop Postin
Hold on
To z axis home
Stop Position Set the stop position
File Maintenance
View File View a file from internal memory or usb disk
Copy File Copy file to or from internal memory and usb disk
Delete File Delete a file form internal memory or usb disk
Password Setup
Class I Password For trial times, if you set this the controller will work for a certain amount of time before the password needs to be entered
Class II Password For trial times, if you set this the controller will work for a certain amount of time before the password needs to be entered
Menu Password Protects important data
Super Password Master password, needs to be set before others can be used
Version View
Initial Version RZNC-D5416/3/ L18 1.2 (zhb59) 45009
Normal Version RZNC-D5416/3/ L18 1.2 (zhb59) 45009