0% found this document useful (0 votes)
2 views

TTCF-9A_Op_Manual

The TTCF-9A Cooler Line Flusher is a high-flow hydraulic system flusher designed for cleaning transmission coolers and lines, featuring adjustable flow rates and multiple flush cycles. It includes safety instructions, operational guidelines, and detailed specifications for effective use. The manual emphasizes the importance of safety and proper operation by qualified personnel to prevent injuries and equipment damage.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

TTCF-9A_Op_Manual

The TTCF-9A Cooler Line Flusher is a high-flow hydraulic system flusher designed for cleaning transmission coolers and lines, featuring adjustable flow rates and multiple flush cycles. It includes safety instructions, operational guidelines, and detailed specifications for effective use. The manual emphasizes the importance of safety and proper operation by qualified personnel to prevent injuries and equipment damage.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

40201524

TTCF-9A
Cooler Line Flusher

Operations Manual

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com


TABLE OF CONTENTS

INTRODUCTION TO THE MACHINE ........................................... 2

CUSTOMER SERVICE CONTACT INFO ..................................... 2

SAFETY INFORMATION ............................................................... 3

MACHINE SPECIFICATIONS & FEATURES ............................... 9

MACHINE OVERVIEW ................................................................ 10

OPERATING INSTRUCTIONS ................................................... 11

MAINTENANCE ........................................................................... 17

REPLACEMENT PARTS ............................................................ 18

WARRANTY INFORMATION ...................................................... 22

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com


INTRODUCTION

Congratulations on the purchase of your TTCF-9A Cooler Line Flusher. The


TTCF-9A is the only variable high-flow transmission component flusher on the
market.

The Flo-Dynamics TTCF-9A Variable High Flow Hydraulic System Flusher will
flush and clean transmission coolers and lines or any hydraulic system of
contamination, sludge, varnish deposits, and particles from a failed transmission.

The TTCF-9A, with an adjustable flow rate from 1-8 GPM, was specially
developed for heavy duty transmission cooling systems requiring high flow rates.
Using the same hydraulic fluid as the hydraulic system being flushed and
cleaned, a user can select from multiple flush cycles ranging from 15-120
minutes and verify system cleanliness by checking the reusable 60 micron
cleanable filter screen.

Using the heating circulation mode, heating to a preset 140°F in 45 minutes is


fast and easy. Two auto-selected GPM-dependent flush patterns designed to
inject the optimal amount of air creating an agitating scrubbing action to remove
trapped debris and solidified waxy varnish. Easily switch flow direction without
removing service hoses during and between flush cycles with the reverser valve.

From the conveniently located control panel, the user can observe system flow,
pressure, temperature, total hours run, filter timer, and easily select pump on/off,
heater on/off, flush cycles, and manual air purge. PATENT PENDING.

Please take time to read through this manual to familiarize yourself with the
machine before performing your first component or transmission cooler
and line flush.

CUSTOMER SERVICE CONTACT INFORMATION


For product information and tech support please call: 800-303-5874
or visit: www.flodynamics.com

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 2


IMPORTANT SAFETY NOTICE
For your safety, read this manual thoroughly before operating this machine. This machine
is intended for use by properly trained, skilled professional automotive technicians. The
safety messages presented below and throughout this user’s manual are reminders to the
operator to exercise care when using this unit. Before using this machine, always refer to
and follow the safety messages and applicable service procedures provided by the
manufacturer of the vehicle being serviced.

• Read All Safety Instructions


Read, understand, and follow all safety messages and instructions in this manual. Safety
messages in this section of the manual contain a signal word with a three-part message
and, in some instances, an icon.

• Signal Words
The signal word indicates the level of the hazard in a situation:

Indicates an imminently hazardous situation which, if not avoided,


will result in death or serious injury to the operator or to bystanders.

Indicates a potentially hazardous situation which, if not avoided,


could result in death or serious injury to the operator or to bystanders.

Indicates a potentially hazardous situation which, if not avoided,


may result in moderate or minor injury to the operator or to bystanders.

Indicates a situation which, if not avoided, may result in damage


to the machine, or the vehicle being serviced.

• Safety Messages
Safety messages in this section contain three different type styles:

• Normal type states the hazard.


• Bold type states how to avoid the hazard.
• Italic type states the possible consequences of not avoiding the hazard.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 3


• Safety Symbols
A safety symbol, when present, gives a graphical description of the potential hazard,
and how to avoid the hazard:

Risk of Fire Read Instructions Before Use

Risk of Explosion Mandatory Eye Protection

Risk of Entanglement Mandatory Protective Gloves

Dangerous Fumes Mandatory Protective Clothing

Do Not Pull or Move Risk of Burns

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 4


IMPORTANT SAFETY INSTRUCTIONS

Engine exhaust contains toxic gases.


• Vent vehicle’s exhaust away from work area.
• Do not breathe exhaust.
Exhaust gases will cause injury or death.

Improper use and operation.


• Read, understand and follow all safety messages and operational procedures in this
manual before operating this machine.
• This equipment should be operated only by qualified personnel.
• Use this equipment only as described in this manual.
Improper use and operation of this product can result in injury.

Engine systems can malfunction expelling fuel, oil vapors, hot steam, hot toxic exhaust gases and
other flying particles.
• Wear safety goggles and protective clothing, user and bystander. Everyday eyeglasses
only have impact resistant lenses; they are NOT safety glasses.
• Do not position head directly over or in front of carburetor or throttle body. Engine
backfire can occur when air cleaner is out of normal position.
• Make sure gauge reads zero before connecting or disconnecting hose connections to
adapters.
• Make sure cooling system pressure has been relieved before connecting or
disconnecting hose connections and adapters.
• Keep a dry chemical (Class B) fire extinguisher rated for gasoline, chemical & electric
fires in the work area.
Fire, explosion, or flying particles may cause serious injury.

Risk of expelling pressurized fluids.


• Wear safety goggles and protective clothing, user, and bystander.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 5


• Engine systems can malfunction, expelling fuel, oil vapors, hot steam, hot toxic exhaust
gases and other debris.
• Always unplug the machine from its power source when not in use.
• Keep the service hoses away from hot or moving engine parts. Hoses can split or burst
causing fluid to be expelled.
• Avoid contact with engine coolant.
• Treatment methods are as follows:
Eyes: Flush eyes with plenty of water.
Skin: Wash with soap and water.
Inhalation: Move to uncontaminated area.
Ingestion: If large amount, get medical attention.
If any irritation persists, get medical attention.
• Dispose of used fluid according to environmental laws and regulations.
Fuel, oil vapors, hot steam, hot toxic exhaust gases, pressurized fluid, and other debris can cause
serious injury.

Risk of unexpected vehicle movement.


• Block drive wheels before starting vehicle’s engine to begin an exchange.
• Unless instructed otherwise, set parking brake and put gear selector in park.
• Do not leave a running vehicle unattended.
• If vehicle has an automatic parking brake release, disconnect release mechanism for
testing and reconnect when testing is completed.
A moving vehicle can cause injury.

Risk of entanglement. Engine has moving parts.


• Do not place tools on fenders or other places in engine compartment.
• Keep yourself, clothing, battery cables and service hoses clear of moving parts such as
fan blades, belts, pulleys, hood and doors.
• Barriers are recommended to help identify danger zones in test area.
• Prevent personnel from walking through immediate test area.
Contact with moving parts can cause injury.

Risk of fire or explosion.


• Do not operate in the vicinity of open containers of flammable liquids such as gasoline.
• Keep hoses and jumper cables away from heat sources and sharp edges.
• Do not operate equipment with damaged cords or hoses until they have been examined
by a qualified serviceman.
Fire or explosion can cause injury.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 6


Risk of fire or explosion. Gases produced by a battery are highly explosive.
• Wear safety goggles and protective clothing, user and bystander.
• Do not smoke, place metal tools on battery or allow a spark or flame in vicinity of battery.
Battery explosion can cause injury.

Risk of burns.
• Wear gloves when handling hot engine components.
• Do not remove radiator cap unless engine is cold.
• Pressurized engine coolant may be hot.
• Do not touch hot exhaust systems, manifolds, engines, radiators, etc.
Hot fluid and engine parts may cause injury.

Battery acid is a highly corrosive sulfuric acid.


• Wear safety goggles and protective gloves, user and bystander.
• Have plenty of fresh water and soap nearby. If battery acid contacts skin, clothing, or
eyes, flush exposed area with soap and water for 10 minutes.
• Do not touch eyes while working near battery.
Battery acid can burn eyes and skin.

Risk of burns.
• Wear gloves when working near hot engine components.
• Do not touch hot exhaust systems, manifolds, engines, radiators, etc.
• The fluid coming from the vehicle along with some of the machine’s components that the
fluid comes into direct contact with (i.e. hoses and fittings) may reach temperatures
uncomfortable to the touch. Exercise caution in avoiding contact with these items.
Hot components can cause injury or discomfort.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 7


Risk of injury.
• This equipment should be operated by qualified personnel only.
• Use this equipment only as described in this manual.
• Always disconnect the machine from air source when not in use.
• Loop the pressure hose loosely in its proper location when machine is not in use.
• Do not operate equipment with a damaged hose, or if the equipment has been dropped or
damaged, until it has been examined by a qualified service representative.
• Care should be taken to arrange the service hoses so that they will not be tripped over or
pulled.
• Never pull on the service hoses to transport the machine. Damage may occur to these
components, or machine may tip over.
• Keep area of operation clear of unnecessary tools and equipment. Utilize recessed tool
storage areas on the top of the machine.
• Never leave the machine running unattended.
• This machine is not designed for any other purpose than the servicing of automotive
cooling systems.
Operation of this machine by anyone other than qualified personnel may result in injury.

Misdiagnosis may lead to incorrect or improper repair and/or adjustment.


• Do not rely on erratic, questionable, or obviously erroneous test information or results. If
test information or results are erratic, questionable, or obviously erroneous, make sure
that all connections and data entry information are correct and that the test procedure was
performed correctly. If test information or results are still suspicious, do not use them for
diagnosis.
Improper repair and/or adjustment may cause vehicle or equipment damage or unsafe operation.

Risk of equipment damage.


• Servicing, transporting, or storing this machine in an attitude other than the normal
operating position can result in fluid spillage and/or component damage.
• Never pull on the service hoses to transport the unit. Damage may occur to these
components, or machine may tip over. Always use the handle to move.
• Periodically clean the machine by wiping down with a clean, soft, dry cloth.
Improper operation of equipment may result in damage to machine or components.

SAVE AND FOLLOW THESE INSTRUCTIONS!

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 8


MACHINE SPECIFICATIONS
Dimensions: 35L x 18W x 41H
Weight: 181 lbs.
Power: 20A or two separate 15A 110V circuits; 75-175 psi shop air

FEATURES
✔ Powerful 3/4 HP motor
✔ Requires a dedicated 20-amp or two separate 15-amp circuits
✔ 13’ heavy duty 3/4” service hoses
✔ 10 gallon transmission fluid capacity with easy to read level sight glass
✔ Adjustable flow rate of 1-8 GPM allows cleaning low to high flow hydraulic systems
✔ Low fluid sensor shuts off heater and pump
✔ 60 micron cleanable screen filter with “T” handle simplifies verification of cleanliness
✔ Reverser valve allows easy flow reversal without removing service hoses
✔ Two auto-selected GPM-dependent flush patterns designed to specifically inject the maximum
amount of air creating an agitating scrubbing action to remove trapped debris and solidified waxy
varnish
✔ Selectable flush times; choose from continuous or 15-120 minutes, with or without air injection
✔ Auto stop and alert at flush cycle end with flush cycle results displayed
✔ Air purge allows for easy fluid removal from system and service hoses
✔ Spin-on filter timer displays hours used
✔ Two non-bypass spin-on magnetic replaceable system filters (P/N 40300272)

CONTROL PANEL FEATURES


✔ Observe system flow, pressure, temperature, total hours run and filter timer
✔ Select pump on/off, heater on/off, flush cycles, and manual air purge
✔ Choose from a variety of flush cycles:
» 15 to 120 minutes
» With or without automatic air injection
» With or without heater
✔ Automatic stop at flush cycle end with audible alert and flush cycle results displayed

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 9


MACHINE OVERVIEW

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 10


OPERATING INSTRUCTIONS
SAFETY RECOMMENDATIONS
This machine uses hot hydraulic fluid under pressure. Check the security of all hoses and connections before operation.
Only use the same hydraulic fluid as used in the hydraulic system being flushed. DO NOT use mineral spirits, solvents, or any other volatile
liquid.
Always wear safety glasses, protective gloves, and proper clothing when operating the flusher.
If hydraulic fluid gets in your eyes or on your skin, rinse with water immediately and seek medical attention if needed.
WARNING: Improper use of this machine can result in burns and other serious injuries. Always wear eye protection, protective clothing, and
follow instructions to prevent potential injury.

CONTROL PANEL OVERVIEW


HEATER:
LED Solid Red = HEATER STATE OFF
A press of the switch will turn the Heater on and change the LED color to Solid Green.
LED Solid Green = HEATER STATE ON
A press of the switch will turn the Heater off and change the LED color to Solid Red.
LED Flashing Red = Low Fluid Level Fault
The first press of the switch will change the LED to solid red only if the low fluid level fault has been corrected.
If the fluid level fault has not been corrected, the LED will remain flashing red.

PUMP:
LED Solid Red = PUMP STATE OFF
A press of the switch will turn the Pump on and change the LED color to Solid Green.
LED Solid Green = PUMP STATE ON
A press of the switch will turn the Pump off and change the LED color to Solid Red.

AUTO AIR AGITATE (if equipped):


LED Solid Red = AIR VALVE DISABLED
A press of the switch will turn the Air valve LED to Solid Green and load in Parameter 1 settings.
LED Solid Green = AIR VALVE PARAMETER 1
A press of this switch will turn the air valve LED to Solid Blue and load in Parameter 2 settings.
LED Solid Blue = AIR VALVE PARAMETER 2
A press of this switch will turn the air valve LED to Solid Red and disable the air valve operation.
LED Off = All Air Valve Functionality Disabled
You can enter and exit this state by holding the switch for 20 seconds.
While in this state the LED will be off, and all other air valve functionality is disabled.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 11


FLUSH PROCEDURE
Fill the tank with 10 gallons of hydraulic fluid or until fluid
level is halfway in sight glass.
WARNING: DO NOT OVERFILL or run with fluid level
higher than halfway in sight glass.
CAUTION: To prevent hydraulic fluid from overflowing
during a flush cycle or when air purging, do not run with
fluid higher than showing over halfway on the sight glass.
Plug the machine into a 20A grounded circuit without
anything else plugged in or being used on the circuit. If a
dedicated 20A circuit is not available, use two separate and
dedicated 15A outlets.
Connect the flusher to 100-125 PSI shop air.
Move the reverser valve to the bypass (middle) position.
CAUTION: Make sure the reverser valve is in the
neutral/bypass position prior to preheating.

Use the MODE button to select “START PREHEAT


HEATER & PUMP” and select “CONT” using the RUN
TIME button.
Check the following:
o Secure fill cap
o Secure filter screen
o Check fluid level
o Check all connections
o Set flow rate
o Set flow direction
Press the START/PAUSE button to begin heating the
flusher while connecting the services hoses.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 12


Connect the red service hose to the cooler inlet line and the
black service hose to the return line of the cooling system.
Once the unit reaches 140 degrees, press the STOP
button.
Press the manual air purge button to clean out the lines.
Remove the top half of the filter housing and place the
screen filter into a waste bucket/container.
Move the Flow Control Valve to position 4.
Use the MODE button to select “START PURGE”. This will
run the initial purge for 7.5 seconds to purge the cooler and
line with clean fluid. Repeat until clean fluid is observed.
Clean the screen filter if needed and reassemble the filter
housing.
Move the reverser valve toward the black hose coming
from the cooling system’s return line. This will backflush the
cooling system.

Use the MODE button to select “START FLUSH”. Use the


RUN TIME button to select the flush cycle time. It is
suggested that the initial flush runs for 15 minutes to
capture initial contaminants within the cooler system.
Press START/PAUSE and check the following:
o Secure fill cap
o Secure filter screen
o Check fluid level
o Check all connections
o Set flow rate
o Set flow direction
Press the START/PAUSE button to start the flush cycle.
At the end of a flush cycle, the flusher will stop and signal
with an audible sound. The display will show “FLUSH
COMPLETE” with before and after flush cycle results.
Press the manual air purge button to clean out the lines.
Remove the top half of the filter housing, note debris on
filter screen, clean the screen, and reassemble the filter
housing.
Repeat flush cycle selecting a desired time using the RUN
TIME button from 15-120 minutes.
NOTE: With an initial flush completed, you can now run
longer flush cycles along with switching the flow direction
using the reverser valve between flush cycles.
Move the reverser valve toward the red service hose.
Use the MODE button to select “START FLUSH”.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 13


Press START/PAUSE and check the following:
o Secure fill cap
o Secure filter screen
o Check fluid level
o Check all connections
o Set flow rate
o Set flow direction
Press the START/PAUSE button to start the flush cycle.
At the end of a flush cycle, the flusher will stop and signal
with an audible sound. The display will show “FLUSH
COMPLETE” with before and after flush cycle results.
Press the manual air purge button to clean out the lines.
Remove the top half of the filter housing, note debris on
filter screen, clean the screen, and reassemble the filter
housing.
NOTE: Always use the manual air purge button prior to
removing the top portion of the screen filter housing to
clean out the cooler system and service hoses.
NOTE: A flush cycle time can be changed anytime by
pressing the RUN TIME button to select a different flush
cycle time.
Switch flow direction by using the reverser valve between
flush cycles. Repeat flush cycles until desired system
cleanliness is achieved.

After system cleanliness is achieved and to disconnect


flusher from system cleaned perform the following:
Use the manual air purge button to clean out the cooling
system and service lines with the reverser valve in either
flow direction, then place in bypass (middle) position.
Remove the service hoses from the system being cleaned
and install service line plugs.
Clean the filter screen and reassemble for the next
cleaning.
Move the Flow Control Valve to a minimal flow position.
Unplug the flusher and disconnect shop air.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 14


ADDITIONAL FUNCTIONS
FILL THE TANK
Remove the fill cap and add enough hydraulic fluid to bring
the level to the middle of the sight glass.
CAUTION: To prevent hydraulic fluid from overflowing
during a flush cycle or when air purging, do not run with
fluid higher than showing over halfway on the sight glass.
Replace the fill cap when full level is reached.

DRAIN THE TANK USING OVERRIDE LEVEL SENSOR MODE


CAUTION: To prevent burns, only drain tank when fluid is
below 100 degrees.
Connect the drain hose adapter to the red banded service
hose.
Move the reverser valve toward the red service hose.
Place the drain hose adapter into a suitable waste
container.
Move the Flow Control Valve to position 3.
CAUTION: Make sure the flow rate is set to a low level to
prevent a high fluid flow into the waste container.
Use the MODE button to select “START OVERRIDE
LEVEL SENSOR”.
Press the START/PAUSE button.
Check the following:
o Secure fill cap
o Secure filter screen
o Check fluid level
o Check all connections
o Set flow rate
o Set flow direction
Press the START/PAUSE button to begin draining. The unit
will run for 10 seconds. Repeat until the unit is drained.
NOTE: There is still approximately one gallon left in the
tank. To completely drain, see “Completely Drain for Fluid
Type Change” procedure below.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 15


COMPLETELY DRAIN THE TANK FOR FLUID TYPE CHANGE
Perform the “Drain Tank Using Override Level Sensor
Mode” procedure above.
Remove pump inlet hose pictured.
Place hose in a suitable waste container to gravity drain
remaining fluid in tank.
After draining replace inlet hose.

AIR VALVE PARAMETER SETTINGS


PARAMETER 1: PARAMETER 2:
# of pulses = 1 # of pulses = 2
Pulse on time = 0.05 seconds Pulse on time = 0.05 seconds
Pulse off time = 0.10 seconds Pulse off time = 0.10 seconds
Time between = 15 seconds Time between = 12 seconds

FUSES
20A FUSE - 5 x 20mm - Qty 2
To access the fuses, remove the (2) bolts securing the
control panel to the flusher, and remove the (4) screws
securing the back of the control panel.
The upper horizontal fuse is for the pump.
The lower vertical fuse is for the heater.
A spare fuse is attached to the inside of the back cover.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 16


MAINTENANCE
To keep your machine working properly:

After Every Cleaning Cycle:


Clean Oberg filter screen with a degreaser. Trying to run the flusher with a filter screen full of
debris can damage your pump and motor.

Daily:
Make sure the ATF level is halfway in the sight glass. Do not overfill or run with fluid level higher
than halfway in the sight glass.

Monthly/Every 100 Flushes:


Replace the spin on filters. This is the most important maintenance you can do on your Heated
Cooler Line Flusher. Change the filters every 100 flushes (approximately once a month).

Quarterly:
Replace the ATF - sooner if it’s black.

Yearly:
Unplug the heater from the electrical box, unscrew heater, and clean the heater’s coils. Oven
cleaner works very well for this.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 17


REPLACEMENT PARTS

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 18


ITEM NO. PART NO. DESCRIPTION QTY.
100 502000 WASHER 1/4 FLT ZN ANSI18-22-1 4
101 40201289 NUT - SS-316 NYLON, 1/4-20 12
102 940503 NUT LK 5/16/18 NYLON INSRT GR2 Z 2
103 40201062 HEX BOLT 1/4-20 X 7/8" SS 10
104 40201288 SCREW - HEX SS-316, FT 1/4-20 X 2-1/4 2
105 501032 1/16-18 X 1-3/4 BOLT 2
106 40201337 PUMP / MOTOR ASSEMBLY - TTCF-9A 1
107 40200963 FLOW METER - GTEC DAQ 1
108 40201362 VALVE-FLOW CONTROL 0-10GPM -12 PORTS 150PSI RELIEF 1
109 40201371 CHECK VALVE - 3/4 NPT FEMALE 1
110 40201361 VALVE-REVERSING 4-WAY OPEN CENTER -10 PORTS 1
111 40201390 FITTING - ELBOW 1/8 NPT HIGH PRESSURE 1
112 40201348 FITTING - 3/4 NPTF MALE X 3/4 NPTF MALE 90 2
113 40201352 FITTING-.75 JIC MALE X .75 MPT 90 ELBOW 4
114 40201351 FITTING-90 DEG STRT ELBOW 3/4MPT X 3/4FPT 1
115 40201364 FITTING -12 PUSH LOK X -12 JIC SWIVEL FEM 8
116 40201358 FITTING -12 MALE JIC X -10 SAE ORB MALE 3
117 40201359 FITTING--12 MALE JIC X -10 SAE ORB 1
118 40201366 FITTING - 3/4 PUSH-LOCK X 1/2 MALE NPT 2
119 40201427 FITTING - ELBOW 1/8 NPTF FEM X 1/8 NPTF MALE 1
120 40201450 FITTING - 3/4" NPTF MALE X 3/4" NPSM FEMALE SWIVEL 4
121 40201479 FITTING-3/4 MALE RUN TEE 1
122 40201472 FITTING - 3/4" JIC MALE X 3/4" NPTF MALE PIPE WITH PORT 1
123 40201349 FITTING- 3/4 NPTF MALE X 3/4 NPTF MALE PIPE HEX NIPPLE 2
124 40201473 FITTING - 1/8 NPTF MALE STRAIGHT CONNECTOR 1
125 40201461 VALVE-3/4 MALE JIC X ¾ MALE ORB 100PSI CHECK 1
126 40201480 FITTING-3/4 MALE NPT X 3/4 FEM ORB 1
127 40201492 FITTING - 1/2 NPTF MALE X 3/4 NPSM FEM SWIVEL 2
128 40201383 CORD GRIP 1/2" KNOCKOUT 1
129 40201389 FITTING - 1/8 NPT X 5/16 TUBE PTC 1
130 40200471 FILTER BRACKET - G TEC 1
131 40300272 FILTER ASSEMBLY-SPIN ON-GTEC 2
132 40201414 WYE STRAINER 3/4" BRONZE 1
133 40201294 FILTER ASSEMBLY HIGH FLOW GTEC 1
134 40201481 POWER CORD - 2 FT - GTEC 9 1
135 40201179 BLACK POLY TUBING 5/16 OD 1
136 40300456 BRACKET-POWER CORD 1
137 40201438 PRESSURE TRANSDUCER PT SERIES 150 PSI VITON 1

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 19


Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 20
ITEM NO. PART NO. DESCRIPTION QTY.
200 40300450 ASSEMBLY-GTEC TANK 1
201 40300352 TUBE-DAQ BOX BRACKET 2
202 40300479 ASSEMBLY-GTEC HANDLE 1
203 941362 SCREW 10-24 X 1.5 BHCS SS 8
204 40201290 SCREW ROUND HEAD PHIL 12-24 X 1/2" METAL CUTTING 4
205 40201395 SCREW - 6/32 X 1" BUTTON HEAD SOCKET BLACK OX PARTIAL THREAD 2
206 40200821 10-32 X 3/8 BUTTON HEAD SCREW STAINLESS 2
207 941271 BOLT 3/8-16 x 1 BUTTON SOCKET 4
208 40200544 1/4-20 X 1/2 HEX CAP SCREW UNC THREAD 16
209 40201289 NUT - SS-316 NYLON, 1/4-20 27
210 501143 NUT 10-24 NYLOCK ZINC 8
211 940503 NUT LK 5/16/18 NYLON INSRT GR2 Z 2
212 40200297 NUT-HEX 10-32 TOOTHED WASHER BLK OX 2
213 941390 NUT 3,8-16 STAR LOCK 4
214 40201062 HEX BOLT 1/4-20 X 7/8" SS 11
215 501032 1/16-18 X 1-3/4 BOLT 2
216 501352 BOLT HHCS 5,16-18-3,4 GR 2 4
217 40200576 FLOAT SWITCH - G TEC 1
218 40201343 VALVE - 24 VOLT DC AIR 1
219 40300351 BRACKET-DAQ BOX MOUNTING 1
220 40300430 BRACKET-MAIN CONTROL BOX 1
221 40300428 BRACKET-FILTER N VALVE MNT 1
222 40300458 PLATE-GTEC MOTOR BRKT REMOVABLE 1
223 40300461 BRACKET-GTEC MOTOR BASE 1
224 40300462 BRACKET-GTEC FRNT VERT 1
225 40300463 BRACKET-GTEC TOP HORZ 1
226 40200496 MALE PLUG WITH CHECK BALL - G TEC 1
227 40200339 1/4 BRASS BULKHEAD FTTG 1
228 40201364 FITTING -12 PUSH LOK x -12 JIC SWIVEL FEM 4
229 40201427 FITTING - ELBOW 1/8 NPTF FEM X 1/8 NPTF MALE 1
230 40201352 FITTING-.75 JIC MALE X .75 MPT 90 ELBOW 1
231 40201353 FITTING-.75JIC X .75MPT STRT 1
232 40201182 BUSHING ADAPTER, 3/4" MNPT x 1/4" FNPT 1
233 40201401 FITTING - TEE 3/4" JIC MALE X 3/4" NPTF MALE PIPE X 3/4" JIC MALE 1
234 40200493 TOOL TRAY - G TEC 1
235 40200458 WHEEL - G TEC 2
236 40200919 ROUND BOTTLE 16 OZ 1
237 40201373 BREATHER VENT 3/8 NPS FEMALE 1
238 40201126 STUD 5/16 TUBE 1/8NPT 2
239 40201381 OVERLAY - CONTROL PANEL G TEC HIGH FLOW TTCF-9A 1
240 40201406 CAP, BOTTLE 1
241 40201475 CAP-GTEC FILL 1
242 40201434 BRASS SIGHT GLASS FOR DARK LIQUID 3/4 NPTF 1
243 R942118 CASTER 4 W/BRAKE ATFX 1
244 40200476 HUB CAPS - G TEC 2
245 40200776 5/8 ID NYLON WHEEL SPACER - G TEC 2
246 40201454 CLAMP-STEEL LOOP 2
247 40201497 STEEL ROD- .5" DIA X 16.75” L 1
248 40201294 FILTER ASSEMBLY HIGH FLOW GTEC 1
249 40200466 HEATER CHROMALOX - G TEC 1
250 40201357 CONTROL ELECTRONICS - TTCF-9A 2
251 40201342 TEMPERATURE SENSOR EXTENSION - G TEC HIGH FLO 1
252 40201521 FEMALE ELECTRICAL SOCKET 3 SLOT NEMA 5-15 1
253 40201464 FITTING - PLASTIC ELBOW 3/4 NPT MALE X 3/4 BARB 1
254 40201465 FITTING - PLASTIC ELBOW 1/2 NPT MALE X 3/4 BARB 1
255 945004 FITTING-5/16 PUSH EP SEALS 1

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 21


LIMITED ONE (1) YEAR WARRANTY
G-TEC TTCF-9A by Flo-Dynamics
Flo-Dynamics warrants only to the original Purchaser that under normal use, care and service,
the Equipment (except as otherwise provided herein) shall be free from defects in material and
workmanship for one year from the date of original invoice. External hoses, remote control
modules, adapters, and all other attachments, supplies and consumables (except as otherwise
provided herein) are warranted for 90 calendar days from the date of original invoice. Filter
elements are not warranted. Printed circuit boards purchased from, but not installed by Seller are
not warranted.

SELLER’S OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED SOLELY TO THE


REPAIR OR, AT SELLER’S OPTION, REPLACEMENT OF EQUIPMENT OR PARTS WHICH
TO SELLER’S SATISFACTION ARE DETERMINED TO BE DEFECTIVE AND WHICH ARE
NECESSARY, IN SELLER’S JUDGEMENT, TO RETURN THE EQUIPMENT TO GOOD
OPERATING CONDITION. NO OTHER WARRANTIES EXPRESS OR IMPLIED OR
STATUTORY, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY AND
ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED.

This warranty does not cover (and separate charges for parts, labor and related expenses shall
apply to) any damage to, malfunctioning, inoperability or improper operation of the Equipment
caused by, resulting from or attributable to (A) abuse, misuse or tampering; (B) alteration,
modification or adjustment of the Equipment by anyone other than Seller’s authorized
representatives; (D) improper or negligent use, application, operation, care, cleaning, storage or
handling; (E) fire, water, wind, lightning or other natural causes; (F) adverse environmental
conditions, including, without limitation, excessive heat, moisture, corrosive elements, or dust or
other air contaminants, radio frequency interference, electric power failure, power line voltages
beyond those specified for the equipment, unusual physical, electrical or electromagnetic stress,
and/or any other condition outside of Seller’s environmental specifications; (G) use of the
Equipment in combination or connection with other equipment, attachments, supplies or
consumables not manufactured or supplied by Seller; or (H) failure to comply with any applicable
federal, state or local regulation.

Repairs or replacements qualifying under this Warranty will be performed on regular business
days during Seller’s normal working hours within a reasonable time following Purchaser’s
request. All requests for Warranty service must be made during the stated Warranty period.
This warranty is non-transferable.

Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874 • flodynamics.com 22