0% found this document useful (0 votes)
18 views50 pages

Slim Pager System IEC 62368

This test report (No. PRSZ24091302S) evaluates the Slim Pager System (Model: CS-18QM) for compliance with IEC 62368-1 safety standards, issued on September 13, 2024, by Shenzhen PTSI Testing Co., Ltd. The system, manufactured by Xiamen Jinchan Electronics Co., Ltd., passed all relevant safety tests, confirming its design and construction meet safety requirements. The report includes details on testing procedures, results, and compliance with national differences, with no significant issues identified.

Uploaded by

Hong Yao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views50 pages

Slim Pager System IEC 62368

This test report (No. PRSZ24091302S) evaluates the Slim Pager System (Model: CS-18QM) for compliance with IEC 62368-1 safety standards, issued on September 13, 2024, by Shenzhen PTSI Testing Co., Ltd. The system, manufactured by Xiamen Jinchan Electronics Co., Ltd., passed all relevant safety tests, confirming its design and construction meet safety requirements. The report includes details on testing procedures, results, and compliance with national differences, with no significant issues identified.

Uploaded by

Hong Yao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 50

Page 1 of 50 Report No.

PRSZ24091302S
Error: Reference source not found
TEST REPORT
IEC 62368-1
Audio/video, information and communication technology equipment
Part 1: Safety requirements
Report Number...............................: PRSZ24091302S
Compiled by (Name + Signature) . : Cathy Zhang
Report Number...............................: Sunny Ge
Date of issue...................................: September 13, 2024
Total number of pages...................: 50
Testing Laboratory.........................: Shenzhen PTSI Testing Co., Ltd.
2/F, Building C, Hongwan Commercial Center, Bao'an Road,
Address......................................... :
Xixiang, Baoan, Shenzhen, China
Testing Location / Address..........: Same as above
Applicant’s name...........................: Xiamen Jinchan Electronics Co., Ltd.
Address...........................................: Floor 8, No. 3, Zhongwan Road, Xinglin North Industrial, JiMei
District, XiaMen City, FuJian Province, China
Test specification:
Standard.........................................: IEC 62368-1:2023
Test procedure...............................: IEC
Non-standard test method............: N/A
TRF template used.........................: IECEE OD-2020-F1:2023, Ed.1.6
Test Report Form No.....................: IEC62368_1F
Test Report Form(s) Originator.....: UL Solutions (US)
Master TRF.....................................: Dated 2023-08-18
Test item description.......................: Slim Pager System
Trademark(s)....................................: N/A
Manufacturer....................................: Same as applicant
Model/Type reference......................: CS-18QM
Ratings..............................................: The Slim Pager System CS-18QM consists of one Transmitter
and charging base CS-4C, Slim Pager System CS-4LED and
Adapter TLY2505-50.
For Adapter (Model: TLY2505-50): Input: 100-240V~, 50/60Hz,
0.6A; Output: 5Vdc, 5A;
For Charging Base (Model: CS-4C): Input: 5Vdc, 5A; Output:
5Vdc;
For Slim Pager System (Model: CS-4LED): 5VDC; or Battery:
3.7Vdc, 250mAh

TRF No. IEC62368_1F


Page 2 of 50 Report No.PRSZ24091302S
Error: Reference source not found
List of Attachments (including a total number of pages in each attachment):
Annex 1: Photos (4 pages)

Summary of testing:

Tests performed (name of test, test clause and Testing location: (CBTL, SPTL, CTF,
date test performed): Subcontractor)
Full 2/F, Building C, Hongwan Commercial Center,
Bao'an Road, Xixiang, Baoan, Shenzhen, China

Summary of compliance with National Differences


N/A

Use of uncertainty of measurement for decisions on conformity (decision rule) :

No decision rule is specified by the IEC standard, when comparing the measurement result with the
applicable limit according to the specification in that standard. The decisions on conformity are made
without applying the measurement uncertainty (“simple acceptance” decision rule, previously known as
“accuracy method”).

Other: … (to be specified, for example when required by the standard or client, or if national
accreditation requirements apply)

Information on uncertainty of measurement:


The uncertainties of measurement are calculated by the laboratory based on application of criteria given
by OD-5014 for test equipment and application of test methods, decision sheets and operational
procedures of IECEE.
IEC Guide 115 provides guidance on the application of measurement uncertainty principles and applying
the decision rule when reporting test results within IECEE scheme, noting that the reporting of the
measurement uncertainty for measurements is not necessary unless required by the test standard or
customer.
Calculations leading to the reported values are on file with the NCB and testing laboratory that conducted
the testing.

TRF No. IEC62368_1F


Page 3 of 50 Report No.PRSZ24091302S
Error: Reference source not found

Copy of marking plate:


The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
Sample:

Charging Base
Model: CS-4C
Input: 5VDC, 5A

Xiamen Jinchan Electronics Co., Ltd.


Made in China

Slim Pager System

Model: CS-4LED
Input: 5VDC

Xiamen Jinchan Electronics Co., Ltd.


Made in China

TRF No. IEC62368_1F


Test item particulars:
Product group..........................................................: end product built-in component
Classification of use by...........................................: Ordinary person Children likely present
Instructed person
Skilled person
Supply connection..................................................: AC mains DC mains
not mains connected:

Supply tolerance .....................................................: +10%/-10%


+20%/-15%
+ %/ - %
None
Supply connection – type ......................................: pluggable equipment type A -
non-detachable supply cord
appliance coupler
direct plug-in
pluggable equipment type B -
non-detachable supply cord
appliance coupler
permanent connection
mating connector
ply
Considered current rating of protective device. . .: 16 A;
Location: building equipment
N/A
Equipment mobility.................................................: movable hand-held transportable
direct plug-in stationary for building-in
wall/ceiling-mounted SRME/rack-mounted
other:
Overvoltage category (OVC) .................................: OVC I OVC II OVC III
OVC IV other:
Class of equipment ................................................: Class I Class II
Class II with functional earthing
Class III Not classified
Special installation location ..................................: N/A restricted access area
outdoor location
Pollution degree (PD) ............................................: PD 1 PD 2 PD 3
Manufacturer’s specified Tma..................................: 40 °C Outdoor: minimum °C
IP protection class .................................................: IPX0 IP___
Power systems .......................................................: TN TT IT - V L-L
not AC mains
Altitude during operation (m) ................................: 2000 m or less m
Altitude of test laboratory (m) ...............................: 2000 m or less m
Mass of equipment (kg) .........................................: 0.1 kg
Possible test case verdicts:
- test case does not apply to the test object...........: N/A
- test object does meet the requirement.................: P (Pass)
- test object does not meet the requirement..........: F (Fail)
Testing......................................................................:
Date of receipt of test item......................................: July 13, 2024
Date (s) of performance of tests..............................: July 13, 2024 - July 21, 2024

General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:


The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided............................................................:

When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies).........................: Same as manufacturer
General product information and other remarks:
Slim Pager System, powered by Adapter. For indoor use only.

Product Descriptions

- The equipment is a system (Model: CS-18QM) which contains charging base (Model: CS-4C), adapter
(Model: TLY2505-50) and slim pager system (Model: CS-4LED).
- When the slim pager system CS-4LED was powered by charging base CS-4C, which was supplied by
AC/DC ADAPTER TLY2505-50, it would only be in charging mode without receiving the signal; when by
battery, it would only be in working mode without being charged.
The specified max. ambient temperature is +40℃.

Model difference:
--
Additional application considerations – (Considerations used to test a component or sub-assembly):
Modification: PRSZ20101003S.
The original Test Report Ref. No. PRSZ20101003S, dated September 23, 2022 was modified include
the following changes:

- Applicant’s / Manufacturer’s name and address were modification as below:


From: Xiamen Yunhu Software Development Co., Ltd./ Room 503, No. 88, 2nd lane of jinhu, Huli District,
Xiamen, Fujian, China
To: Xiamen Jinchan Electronics Co., Ltd./ Floor 8, No. 3, Zhongwan Road, Xinglin North Industrial, JiMei
District, XiaMen City, FuJian Province, China;

After review, no additional test was considered necessary


OVERVIEW OF ENERGY SOURCES AND SAFEGUARDS
Clause Possible Hazard
5 Electrically-caused injury
Class and Energy Source Body Part Safeguards
(e.g. ES3: Primary circuit) (e.g. Ordinary) B S R
ES1: All Internal circuits Ordinary person N/A N/A N/A
6 Electrically-caused fire
Class and Energy Source Material part Safeguards
(e.g. PS2: 100 Watt circuit) (e.g. Printed board) B 1st S 2nd S
1. No ignition 1. PCB is N/A
occurred. complied with
2. No parts V-1 material;
exceeding 2. all other
90% of its components:
spontaneous at least V-2
All Flammable materials ignition except for
PS2: All circuits within
inside and plastic/ metal temperature. mounted on
equipment
enclosure min. V-1
material or
small parts of
combustible
material
3. Plastic
enclosure V-0
used
7 Injury caused by hazardous substances
Class and Energy Source Body Part Safeguards
(e.g. Ozone) (e.g., Skilled) B S R
None N/A N/A N/A N/A
8 Mechanically-caused injury
Class and Energy Source Body Part Safeguards
(e.g. MS3: Plastic fan blades) (e.g. Ordinary) B S R
MS1: Movable unit Ordinary person N/A N/A N/A
MS1: Sharp edges and corners Ordinary person N/A N/A N/A
MS1: Equipment mass (≦7kg) Ordinary person N/A N/A N/A
9 Thermal burn
Class and Energy Source Body Part Safeguards
(e.g. TS1: Keyboard caps) (e.g., Ordinary) B S R
TS1: Internal parts / N/A N/A N/A
Ordinary person
components
Enclosure Ordinary person N/A N/A N/A
10 Radiation
Class and Energy Source Body Part Safeguards
(e.g. RS1: PMP sound output) (e.g., Ordinary) B S R
N/A N/A N/A N/A N/A
Supplementary Information:
“B” – Basic Safeguard; “S” – Supplementary Safeguard; “R” – Reinforced Safeguard

ENERGY SOURCE DIAGRAM


Optional. Manufacturers are to provide the energy sources diagram identify declared energy sources and
identifying the demarcations are between power sources. Recommend diagram be provided included in
power supply and multipart systems.
Insert diagram below. Example diagram designs are; Block diagrams; image(s) with layered data; mechanical
drawings

ES PS MS TS RS
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

4 GENERAL REQUIREMENTS P
4.1.1 Acceptance of materials, components and
P
subassemblies
4.1.2 Use of components Components and
subassemblies which are
comply with the
requirements of this
standard or within the safety P
aspects of the relevant IEC
component standards.
See appended table 4.1.2.
4.1.3 Equipment design and construction P
4.1.15 Markings and instructions (See Annex F) P
4.4.4 Safeguard robustness P
4.4.4.2 Steady force tests (See Annex T.3, T.4, T.5) P
4.4.4.3 Drop tests (See Annex T.7) N/A
4.4.4.4 Impact tests (See Annex T.6) P
4.4.4.5 Internal accessible safeguard enclosure and barrier The external enclosure
tests cannot be opened without P
damaging the product.
4.4.4.6 Glass Impact tests No such glass used. N/A
4.4.4.7 Thermoplastic material tests (See Annex T.8) P
4.4.4.8 Air comprising a safeguard (See Annex T) N/A
4.4.4.9 Accessibility and safeguard effectiveness P
4.5 Explosion No explosion occurs during
normal/abnormal operation P
and single fault conditions
4.6 Fixing of conductors N/A
4.6.1 Fix conductors not to defeat a safeguard N/A
4.6.2 10 N force test applied to N/A
4.7 Equipment for direct insertion into mains socket –
N/A
outlets
4.7.2 Mains plug part complies with the relevant standard --
4.7.3 Torque (Nm) --
4.8 Products containing coin/button cell batteries N/A
4.8.2 Instructional safeguard N/A
4.8.3 Battery Compartment Construction N/A
Means to reduce the possibility of children removing
the battery N/A

4.8.4 Battery Compartment Mechanical Tests (See Table 4.8.4) N/A

Page 9 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

4.8.5 Battery Accessibility N/A


4.9 Likelihood of fire or shock due to entry of conductive (See Annex P)
N/A
object
5 ELECTRICALLY-CAUSED INJURY P
5.2.1 Electrical energy source classifications (See appended table 5.2)

5.2.2 ES1, ES2 and ES3 limits P
5.2.2.2 Steady-state voltage and current See appended table 5.2) N/A
5.2.2.3 Capacitance limits (See appended table 5.2) N/A
5.2.2.4 Single pulse limits (See appended table 5.2) N/A
5.2.2.5 Limits for repetitive pulses (See appended table 5.2) N/A
5.2.2.6 Ringing signals (See Annex H) N/A
5.2.2.7 Audio signals (See Clause E.1) N/A
5.3 Protection against electrical energy sources N/A
5.3.1 General Requirements for accessible parts to ordinary,
instructed and skilled persons N/A

5.3.2.1 Accessibility to electrical energy sources and


safeguards N/A

5.3.2.2 Contact requirements N/A


a) Test with test probe from Annex V N/A
b) Electric strength test potential (V) N/A
c) Air gap (mm) N/A
5.3.2.4 Terminals for connecting stripped wire N/A
5.4 Insulation materials and requirements P
5.4.1.2 Properties of insulating material N/A
5.4.1.3 Humidity conditioning (See sub-clause 5.4.8) N/A
5.4.1.4 Maximum operating temperature for insulating (See appended table
5.4.1.4) P
materials
5.4.1.5 Pollution degree 2 N/A
5.4.1.5.2 Test for pollution degree 1 environment and for an
insulating compound N/A

5.4.1.5.3 Thermal cycling N/A


5.4.1.6 Insulation in transformers with varying dimensions N/A
5.4.1.7 Insulation in circuits generating starting pulses N/A
5.4.1.8 Determination of working voltage N/A
5.4.1.9 Insulating surfaces N/A

Page 10 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

5.4.1.10 Thermoplastic parts on which conductive metallic parts


are directly mounted N/A

5.4.1.10.2 Vicat softening temperature (See appended table


5.4.1.10.2) N/A

5.4.1.10.3 Ball pressure (See appended table


5.4.1.10.3) N/A

5.4.2 Clearances N/A


5.4.2.2 Determining clearance using peak working voltage N/A
5.4.2.3 Determining clearance using required withstand
voltage N/A

a) a.c. mains transient voltage N/A


b) d.c. mains transient voltage N/A
c) external circuit transient voltage No such external circuit N/A
d) transient voltage determined by measurement Not applicable N/A
5.4.2.4 Determining the adequacy of a clearance using an
electric strength test N/A

5.4.2.5 Multiplication factors for clearances and test voltages N/A


5.4.3 Creepage distances (See appended table 5.4.3) N/A
5.4.3.1 General N/A
5.4.3.3 Material Group Material group IIIb be
P
assumed.
5.4.4 Solid insulation N/A
5.4.4.2 Minimum distance through insulate on (See appended table
5.4.4.2) N/A

5.4.4.3 Insulation compound forming solid insulation N/A


5.4.4.4 Solid insulation in semiconductor devices N/A
5.4.4.5 Cemented joints N/A
5.4.4.6 Thin sheet material N/A
5.4.4.6.1 General requirements N/A
5.4.4.6.2 Separable thin sheet material N/A
Number of layers (pcs) N/A
5.4.4.6.3 Non-separable thin sheet material N/A
5.4.4.6.4 Standard test procedure for non-separable thin sheet (See appended Table 5.4.9)
N/A
material
5.4.4.6.5 Mandrel test N/A
5.4.4.7 Solid insulation in wound components See clause G.5 and G.6. N/A
5.4.4.9 Solid insulation at frequencies >30 kHz (See appended Table
5.4.4.9) N/A

5.4.5 Antenna terminal insulation N/A

Page 11 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

5.4.5.1 General N/A


5.4.5.2 Voltage surge test N/A
Insulation resistance (MΩ) N/A
5.4.6 Insulation of internal wire as part of supplementary No such insulation of N/A
safeguard internal wire as part of
supplementary insulation.
5.4.7 Tests for semiconductor components and for cemented N/A
joints
5.4.8 Humidity conditioning P
Relative humidity (%) ........................................ : 93 N/A
Temperature (°C) ............................................. : 40 N/A
Duration (h) ..................................................... : 120 N/A
5.4.9 Electric strength test N/A
5.4.9.1 Test procedure for a solid insulation type test N/A
5.4.9.2 Test procedure for routine tests N/A
5.4.10 Protection against transient voltages between external N/A
circuit
5.4.10.1 Parts and circuits separated from external circuits N/A
5.4.10.2 Test methods N/A
5.4.10.2.1 General N/A
5.4.10.2.2 Impulse test N/A

5.4.10.2.3 Steady-state test N/A

5.4.11 Insulation between external circuits and earthed N/A


circuitry
5.4.11.1 Exceptions to separation between external circuits and N/A
earth
5.4.11.2 Requirements N/A
Rated operating voltage Uop (V) : N/A
Nominal voltage Upeak (V) : N/A
Max increase due to variation Usp : N/A
Max increase due to ageing ΔUsa : N/A
Uop= Upeak + Δ Usp + ΔUsa : N/A
5.5 Components as safeguards N/A
5.5.1 General N/A
5.5.2 Capacitors and RC units N/A
5.5.2.1 General requirement N/A

Page 12 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

5.5.2.2 Safeguards against capacitor discharge after (See appended table N/A
disconnection of a connector 5.5.2.2)
5.5.3 Transformers (See Annex G.5.3) N/A
5.5.4 Optocouplers (See sub-clause 5.4 or N/A
Annex G.12)
5.5.5 Relays (See Annex G.2) N/A
5.5.6 Resistors (See Annex G.10) N/A
5.5.7 SPD‘s (See Annex G.8) N/A
5.5.7.1 Use of an SPD connected to reliable earthing N/A
5.5.7.2 Use of an SPD between mains and protective earth N/A
5.5.8 Insulation between the mains and external circuit (See Annex G.10.3) N/A
consisting of a coaxial cable
5.6 Protective conductor N/A
5.6.2 Requirement for protective conductors N/A
5.6.2.1 General requirements N/A
5.6.2.2 Colour of insulation N/A
5.6.3 Requirement for protective earthing conductors N/A
Protective earthing conductor size (mm2) : N/A
5.6.4 Requirement for protective bonding conductors N/A
5.6.4.1 Protective bonding conductors N/A
Protective bonding conductor size (mm2). : N/A
Protective current rating (A) : N/A
5.6.4.3 Current limiting and overcurrent protective devices N/A
5.6.5 Terminals for protective conductors N/A
5.6.5.1 Requirement N/A
Conductor size (mm2), nominal thread diameter (mm) N/A
5.6.5.2 Corrosion N/A
5.6.6 Resistance of the protective system N/A
5.6.6.1 Requirements N/A
5.6.6.2 Test Method Resistance (Ω) : N/A
5.6.7 Reliable earthing N/A
5.7 Prospective touch voltage, touch current and N/A
protective conductor current
5.7.2 Measuring devices and networks N/A
5.7.2.1 Measurement of touch current (See appended table N/A
5.2.2.2)
5.7.2.2 Measurement of prospective touch voltage N/A

Page 13 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

5.7.3 Equipment set-up, supply connections and earth N/A


connections
System of interconnected equipment (separate N/A
connections/single connection) :
Multiple connections to mains (one connection at a N/A
time/simultaneous connections) :
5.7.4 Earthed conductive accessible parts (See appended Table 5.7.4) N/A
5.7.5 Protective conductor current N/A
Supply Voltage (V) : N/A
Measured current (mA) : N/A
Instructional Safeguard : (See F.4 and F.5) N/A
5.7.6 Prospective touch voltage and touch current due to N/A
external circuits
5.7.6.1 Touch current from coaxial cables N/A
5.7.6.2 Prospective touch voltage and touch current from N/A
external circuits
5.7.7 Summation of touch currents from external circuits N/A
a) Equipment with earthed external circuits Measured N/A
current (mA) :
b) Equipment whose external circuits are not N/A
referenced to earth. Measured current (mA) :
6 ELECTRICALLY- CAUSED FIRE P
6.2 Classification of power sources (PS) and potential ignition sources (PIS) P
6.2.2 Power source circuit classifications See Energy source P
identification and
classification table.
6.2.2.1 General P
6.2.2.2 Power measurement for worst-case load fault : (See appended table 6.2.2) N/A
6.2.2.3 Power measurement for worst-case power source fault (See appended table 6.2.2) N/A
6.2.2.4 PS1 ................................................................. : P
6.2.2.5 PS2 ................................................................. : P
6.2.2.6 PS3 ................................................................. : N/A
6.2.3 Classification of potential ignition sources N/A
6.2.3.1 Arcing PIS ....................................................... : N/A
6.2.3.2 Resistive PIS ................................................... : P
6.3 Safeguards against fire under normal operating and abnormal operating conditions P

Page 14 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

6.3.1 (a) No ignition and attainable temperature value less (See appended table --
than 90 % defined by ISO 871 or less than 300 。C for 5.4.1.4, 6.3.2, 9.0, B.2.6)
unknown materials............................................ :

6.3.1 (b) Combustible materials outside fire enclosure See appended table 4.1.2. --
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard Method Method of Control fire
spread used. See sub- P
clause 6.4.4 to 6.4.6.
6.4.2 Reduction of the likelihood of ignition under single fault
P
conditions in PS1 circuits
6.4.3 Reduction of the likelihood of ignition under single fault PS2
P
conditions in PS2 and PS3 circuits
6.4.3.1 General P
6.4.3.2 Supplementary Safeguards N/A
Special conditions if conductors on printed boards are
N/A
opened or peeled
6.4.3.3 Single Fault Conditions ................................ : (See appended table 6.4.3) --
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits P
6.4.5 Control of fire spread in PS2 circuits P
6.4.5.2 Supplementary safeguards (See appended tables 4.1.2
P
and Annex G)
6.4.6 Control of fire spread in PS3 circuit (See appended tables 4.1.2
N/A
and Annex G)
6.4.7 Separation of combustible materials from a PIS N/A
6.4.7.1 General (See tables 6.2.3.1 and
6.2.3.2) --

6.4.7.2 Separation by distance N/A


6.4.7.3 Separation by a fire barrier N/A
6.4.8 Fire enclosures and fire barriers P
6.4.8.1 Fire enclosure and fire barrier material properties Metal/plastic enclosure is
P
provided as fire enclosure.
6.4.8.2.1 Requirements for a fire barrier N/A
6.4.8.2.2 Requirements for a fire enclosure P
6.4.8.3 Constructional requirements for a fire enclosure and
P
a fire barrier
6.4.8.3.1 Fire enclosure and fire barrier openings P
6.4.8.3.2 Fire barrier dimensions N/A

Page 15 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

6.4.8.3.3 Top Openings in Fire Enclosure: dimensions (mm) PS1 and ES1 circuits. --
Openings not affect the
safety.

Needle Flame test N/A


6.4.8.3.4 Bottom Openings in Fire Enclosure, condition met a), PS1 and ES1 circuits. --
b) and/or c) dimensions (mm) ............................. : Openings not affect the
safety.
Flammability tests for the bottom of a fire enclosure --
6.4.8.3.5 Integrity of the fire enclosure, condition met: a), b) or --
c)
6.4.8.4 Separation of PIS from fire enclosure and fire barrier Annex S.2 applied. --
distance (mm) or flammability rating .................... :
6.5 Internal and external wiring P
6.5.1 Requirements Wirings are UL recognized P
and marked with VW-1.
6.5.2 Cross-sectional area (mm2) .............................. : --
6.5.3 Requirements for interconnection to building wiring --
6.6 Safeguards against fire due to connection to additional (See Annex Q.) N/A
equipment
External port limited to PS2 or complies with Clause (See Annex Q.) N/A
Q.1

7 INJURY CAUSED BY HAZARDOUS SUBSTANCES N/A


7.2 Reduction of exposure to hazardous substances N/A
7.3 Ozone exposure N/A
(IEC 60950-1, 1.7.2.6)
7.4 Use of personal safeguards (PPE) N/A
Personal safeguards and instructions ................. : --
7.5 Use of instructional safeguards and instructions N/A
Instructional safeguard (ISO 7010) ..................... : --
7.6 Batteries............................................................ : (See Annex M) --

8 MECHANICALLY-CAUSED INJURY P
8.1 General P
8.2 Mechanical energy source classifications See Energy source P
identification and
classification table.
8.3 Safeguards against mechanical energy sources N/A

Page 16 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

8.4 Safeguards against parts with sharp edges and N/A


corners
8.4.1 Safeguards N/A
8.5 Safeguards against moving parts N/A
8.5.1 MS2 or MS3 part required to be accessible for the N/A
function of the equipment
8.5.2 Instructional Safeguard N/A
8.5.4 Special categories of equipment comprising moving N/A
parts
8.5.4.1 Large data storage equipment N/A
8.5.4.2 Equipment having electromechanical device for N/A
destruction of media
8.5.4.2.1 Safeguards and Safety Interlocks (See Annex F.4 and --
Annex K)
8.5.4.2.2 Instructional safeguards against moving parts N/A
Instructional Safeguard N/A
8.5.4.2.3 Disconnection from the supply N/A
8.5.4.2.4 Probe type and force (N) --
8.5.5 High Pressure Lamps N/A
8.5.5.1 Energy Source Classification N/A
8.5.5.2 High Pressure Lamp Explosion Test --
8.6 Stability N/A
8.6.1 Product classification N/A
Instructional Safeguard --
8.6.2 Static stability N/A
8.6.2.2 Static stability test N/A

Applied Force --
8.6.2.3 Downward Force Test N/A
8.6.3 Relocation stability test N/A

Unit configuration during 10。tilt --


8.6.4 Glass slide test N/A
8.6.5 Horizontal force test (Applied Force) --
Position of feet or movable parts --
8.7 Equipment mounted to wall or ceiling N/A

Page 17 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

8.7.1 Mounting Means (Length of screws (mm) and --


mounting surface)

8.7.2 Direction and applied force --


8.8 Handles strength N/A
8.8.1 Classification N/A
8.8.2 Applied Force --
8.9 Wheels or casters attachment requirements N/A
8.9.1 Classification N/A
8.9.2 Applied force --
8.10 Carts, stands and similar carriers N/A
8.10.1 General N/A
8.10.2 Marking and instructions N/A
Instructional Safeguard --
8.10.3 Cart, stand or carrier loading test and compliance N/A
Applied force --
8.10.4 Cart, stand or carrier impact test N/A
8.10.5 Mechanical stability N/A
Applied horizontal force (N) --
8.10.6 Thermoplastic temperature stability (。C) --
8.11 Mounting means for rack mounted N/A
equipment (IEC 60950-1,Annex DD)

8.11.1 General N/A


(IEC 60950-1, DD.1)
8.11.2 Product Classification N/A
8.11.3 Mechanical strength test, variable N --
8.11.4 Mechanical strength test 250N, including end stops N/A
8.12 Telescoping or rod antennas (See Annex T) --
Button/Ball diameter (mm).................................. : --

9 THERMAL BURN INJURY P


9.2 Thermal energy source classifications See Energy source P
identification and
classification table.
9.3 Safeguard against thermal energy sources P
9.4 Requirements for safeguards P

Page 18 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

9.4.1 Equipment safeguard Metal/plastic enclosure is P


used to limit the transfer of
thermal energy (source
temperature) under normal
operating conditions and
abnormal operating
conditions.
9.4.2 Instructional safeguard N/A
10 RADIATION P
10.2 Radiation energy source classification RS1 P
10.2.1 General classification N/A
10.3 Protection against laser radiation N/A
Laser radiation that exists equipment.................. : --
Normal, abnormal, single-fault ............................ : --
Instructional safeguard....................................... : --
Tool ................................................................... : --
10.4 Protection against visible, infrared, and UV radiation LED indicator P
10.4.1 General N/A
10.4.1.a) RS3 for Ordinary and instructed persons ............ : --
10.4.1.b) RS3 accessible to a skilled person ..................... : --
Personal safeguard (PPE) instructional safeguard : --
10.4.1.c) Equipment visible, IR, UV does not exceed RS1 . : --
10.4.1.d) Normal, abnormal, single-fault conditions ........... : (See appended table B.3 &
B.4)
10.4.1.e) Enclosure material employed as safeguard is opaque --
10.4.1.f) UV attenuation .................................................. : --
10.4.1.g) Materials resistant to degradation UV ................. : --
10.4.1.h) Enclosure containment of optical radiation .......... : --
10.4.1.i) Exempt Group under normal operating conditions : --
10.4.2 Instructional safeguard....................................... : --
10.5 Protection against x-radiation N/A
10.5.1 X- radiation energy source that exists equipment : (See appended table B.3 & --
B.4)
Normal, abnormal, single fault conditions N/A
Equipment safeguards --
Instructional safeguard for skilled person --

Page 19 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

10.5.3 Most unfavourable supply voltage to give maximum --


radiation
Abnormal and single-fault condition (See appended table B.3 & --
B.4)
Maximum radiation (pA/kg) --
10.6 Protection against acoustic energy sources N/A
10.6.1 General N/A
10.6.2 Classification N/A
Acoustic output, dB(A) --
Output voltage, unweighted r.m.s. --
10.6.4 Protection of persons N/A
Instructional safeguards --
Equipment safeguard prevent ordinary person to RS2 --
Means to actively inform user of increase sound --
pressure
Equipment safeguard prevent ordinary person to RS2 --
10.6.5 Requirements for listening devices (headphones, N/A
earphones, etc.)
10.6.5.1 Corded passive listening devices with analogue input N/A

Input voltage with 94 dB(A) LAeq acoustic pressure --


output
10.6.5.2 Corded listening devices with digital input N/A
Maximum dB(A) --
10.6.5.3 Cordless listening device N/A
Maximum dB(A)................................................. : --

B Normal Operating Condition Tests, Abnormal Operating Condition Tests P


and Single Fault Condition Tests
B.2 Normal Operating Conditions P
B.2.1 General requirements ........................................ : (See Test Item Particulars —
and appended test tables)
Audio Amplifiers and equipment with audio amplifiers (See Annex E) N/A
B.2.3 Supply voltage and tolerances N/A
B.2.5 Input test ........................................................... : (See appended table B.2.5) P
B.3 Simulated abnormal operating conditions P
B.3.1 General requirements ........................................ : (See appended table B.3) —
B.3.2 Covering of ventilation openings N/A

Page 20 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

B.3.3 D.C. mains polarity test N/A


B.3.4 Setting of voltage selector .................................. : N/A
B.3.5 Maximum load at output terminals ...................... : N/A
B.3.6 Reverse battery polarity P
B.3.7 Abnormal operating conditions as specified in Clause N/A
E.2.
B.3.8 Safeguards functional during and after abnormal All safeguards remained P
operating conditions effectively.
B.4 Simulated single fault conditions P
B.4.2 Temperature controlling device open or short-circuited (See appended table B.4) N/A
B.4.3 Motor tests N/A
B.4.3.1 Motor blocked or rotor locked increasing the internal (See Clause G.5) —
ambient temperature ......................................... :
B.4.4 Short circuit of functional insulation P
B.4.4.1 Short circuit of clearances for functional insulation P
B.4.4.2 Short circuit of creepage distances for P
functional insulation
B.4.4.3 Short circuit of functional insulation on coated printed Not such printed board N/A
boards
B.4.5 Short circuit and interruption of electrodes in tubes and P
semiconductors
B.4.6 Short circuit or disconnect of passive components P
B.4.7 Continuous operation of components N/A
B.4.8 Class 1 and Class 2 energy sources within limits P
during and after single fault conditions
B.4.9 Battery charging under single fault conditions : (See Annex M) —
C UV Radiation N/A
C.1 Protection of materials in equipment from UV radiation N/A
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test N/A
C.2.1 Test apparatus N/A
C.2.2 Mounting of test samples N/A
C.2.3 Carbon-arc light-exposure apparatus N/A
C.2.4 Xenon-arc light exposure apparatus N/A

Page 21 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

D Test Generators N/A


D.1 Impulse test generators N/A
D.2 Antenna interface test generator N/A
D.3 Electronic pulse generator N/A

E Test Conditions for Equipment Containing Audio Amplifiers N/A


E.1 Audio amplifier normal operating conditions N/A
Audio signal voltage (V) ................................ : --
Rated load impedance (Ω) ................................ : --
E.2 Audio amplifier abnormal operating conditions N/A
F Equipment Markings, Instructions, and Instructional Safeguards P
F.1 General requirements P
Instructions – Language English --
F.2 Letter symbols and graphical symbols P
F.2.1 Letter symbols according to IEC60027-1 P
F.2.2 Graphic symbols IEC, ISO or manufacturer specific P
F.3 Equipment markings P
F.3.1 Equipment marking locations Markings are on the exterior P
of equipment.
F.3.2 Equipment identification markings See below P
F.3.2.1 Manufacturer identification ................................ : --
F.3.2.2 Model identification ........................................... : --
F.3.3 Equipment rating markings See below P
F.3.3.1 Equipment with direct connection to mains N/A
F.3.3.2 Equipment without direct connection to mains P
F.3.3.3 Nature of supply voltage : DC or 二二二 --
F.3.3.4 Rated voltage --

F.3.3.4 Rated frequency: --


F.3.3.6 Rated current or rated power --

F.3.3.7 Equipment with multiple supply connections N/A


F.3.4 Voltage setting device N/A
F.3.5 Terminals and operating devices N/A
F.3.5.1 Mains appliance outlet and socket-outlet markings --

Page 22 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

F.3.5.2 Switch position identification marking --


F.3.5.3 Replacement fuse identification and rating markings --
F.3.5.4 Replacement battery identification marking --
F.3.5.5 Terminal marking location N/A
F.3.6 Equipment markings related to equipment N/A
classification
F.3.6.1 Class I Equipment N/A
F.3.6.1.1 Protective earthing conductor terminal N/A
F.3.6.1.2 Neutral conductor terminal N/A
F.3.6.1.3 Protective bonding conductor terminals N/A
F.3.6.2 Class II equipment (IEC60417-5172) N/A
F.3.6.2.1 Class II equipment with or without functional earth N/A
(IEC 60065, 5.2 c)) & (IEC 60950-1, 1.7.7.2)
F.3.6.2.2 Class II equipment with functional earth terminal N/A
marking
F.3.7 Equipment IP rating marking ............................. : IPX0

F.3.8 External power supply output marking The voltage rating, the P
current rating and the
polarity are provided.
F.3.9 Durability, legibility and permanence of marking P
F.3.10 Test for permanence of markings After this test there was no P
damage to the label. The
marking on the label did not
fade. There was neither
curling nor lifting of the label
edge.
F.4 Instructions N/A
a) Equipment for use in locations where children not N/A
likely to be present – marking
b) Instructions given for installation or initial use N/A
c) Equipment intended to be fastened in place N/A
d) Equipment intended for use only in restricted access N/A
area
e) Audio equipment terminals classified as ES3 and N/A
other equipment with terminals marked in accordance
F.3.6.1
f) Protective earthing employed as safeguard N/A
g) Protective earthing conductor current exceeding ES N/A
2 limits
h) Symbols used on equipment N/A

Page 23 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

i) Permanently connected equipment not provided N/A


with all-pole mains switch
j) Replaceable components or modules providing N/A
safeguard function
F.5 Instructional safeguards N/A
Where ―instructional safeguard‖ is referenced in the N/A
test report it specifies the required elements, location
of marking and/or instruction
G Components P
G.1 Switches N/A
G.1.1 General requirements N/A
G.1.2 Ratings, endurance, spacing, maximum load N/A
G.2 Relays N/A

G.2.1 General requirements N/A


G.2.2 Overload test N/A
G.2.3 Relay controlling connectors supply power N/A
G.2.4 Mains relay, modified as stated in G.2 N/A
G.3 Protection Devices N/A
G.3.1 Thermal cut-offs N/A

G.3.1.1a) Thermal cut-outs separately approved according to N/A


&b) IEC 60730 with conditions indicated in a) & b)
G.3.1.1c) Thermal cut-outs tested as part of the equipment as N/A
indicated inc)
G.3.1.2 Thermal cut-off connections maintained and secure N/A
G.3.2 Thermal links N/A
G.3.2.1a) Thermal links separately tested with IEC 60691 N/A
G.3.2.1b) Thermal links tested as part of the equipment N/A
Aging hours (H) : --
Single Fault Condition : --
Test Voltage (V) and Insulation Resistance (Ω) : --
G.3.3 PTC Thermistors N/A
G.3.4 Overcurrent protection devices See appended table 4.1.2 N/A
G.3.5 Safeguards components not mentioned in G.3.1 to N/A
G.3.4
G.3.5.1 Non-resettable devices suitably rated and marking N/A
provided
G.3.5.2 Single faults conditions : (See appended Table B.4) —

Page 24 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

G.4 Connectors N/A


G.4.1 Spacings N/A
G.4.2 Mains connector configuration ........................... :
G.4.3 Plug is shaped that insertion into mains socket-outlets N/A
or appliance coupler is unlikely
G.5 Wound Components N/A
G.5.1 Wire insulation in wound components (See Annex J) —
G.5.1.2 a) Two wires in contact inside wound component, angle N/A
between 45°and 90°
G.5.1.2 b) Construction subject to routine testing N/A
G.5.2 Endurance test on wound components N/A
G.5.2.1 General test requirements N/A
G.5.2.2 Heat run test N/A
Time (s)............................................................. : --
Temperature (。C) ............................................... : --
G.5.2.3 Wound Components supplied by mains N/A
G.5.3 Transformers N/A
G.5.3.1 Requirements applied Complied with G.5.3.2 and --
G.5.3.3
Position : --
Method of protection : --
G.5.3.2 Insulation N/A
Protection from displacement of windings : --
G.5.3.3 Overload test : (See appended table B.3) --
G.5.3.3.1 Test conditions N/A
G.5.3.3.2 Winding Temperatures testing in the unit N/A
G.5.3.3.3 Winding Temperatures - Alternative test method N/A
G.5.4 Motors N/A

G.5.4.1 General requirements N/A

Position ............................................................ : --
G.5.4.2 Test conditions N/A
G.5.4.3 Running overload test N/A
G.5.4.4 Locked-rotor overload test N/A
Test duration (days) .......................................... : --

G.5.4.5 Running overload test for d.c. motors in secondary N/A


circuits
G.5.4.5.2 Tested in the unit N/A

Page 25 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

Electric strength test (V) ................................ : --


G.5.4.5.3 Tested on the Bench - Alternative test method; test --
time (h) ............................................................. :
Electric strength test (V) ................................ : --
G.5.4.6 Locked-rotor overload test for d.c. motors in secondary N/A
circuits
G.5.4.6.2 Tested in the unit N/A

Maximum Temperature ................................ : --


Electric strength test (V) ................................ : --
G.5.4.6.3 Tested on the bench - Alternative test method; test --
time (h) ............................................................. :
Electric strength test (V) ................................ : --
G.5.4.7 Motors with capacitors N/A
G.5.4.8 Three-phase motors N/A
G.5.4.9 Series motors N/A
Operating voltage ............................................. : --
G.6 Wire Insulation N/A
G.6.1 General . N/A
G.6.2 Solvent-based enamel wiring insulation N/A
G.7 Mains supply cords N/A

G.7.1 General requirements N/A


Type............................................................................ --

Rated current (A) : --

Cross-sectional area (mm2), (AWG) : --

G.7.2 Compliance and test method N/A


G.7.3 Cord anchorages and strain relief for non-detachable N/A
power supply cords
G.7.3.2 Cord strain relief N/A
G.7.3.2.1 Requirements N/A
Strain relief test force (N)................................ : --

G.7.3.2.2 Strain relief mechanism failure N/A


G.7.3.2.3 Cord sheath or jacket position, distance (mm) : --
G.7.3.2.4 Strain relief comprised of polymeric material N/A
G.7.4 Cord Entry : (See appended table --
5.4.11.1)

Page 26 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

G.7.5 Non-detachable cord bend protection N/A


G.7.5.1 Requirements N/A
G.7.5.2 Mass (g) : --

Diameter (m) ..................................................... : --


Temperature (。C) ............................................... : --
G.7.6 Supply wiring space N/A
G.7.6.2 Stranded wire N/A
G.7.6.2.1 Test with 8 mm strand N/A
G.8 Varistors N/A
G.8.1 General requirements N/A
G.8.2 Safeguard against shock N/A
G.8.3 Safeguard against fire N/A
G.8.3.2 Varistor overload test : (See appended table B.3) --

G.8.3.3 Temporary overvoltage : (See appended table B.3) --

G.9 Integrated Circuit (IC) Current Limiters N/A


G.9.1 a) Manufacturer defines limit at max. 5A. N/A
G.9.1 b) Limiters do not have manual operator or reset N/A
G.9.1 c) Supply source does not exceed 250 VA ............. --
G.9.1 d) IC limiter output current (max. 5A) ...................... : --
G.9.1 e) Manufacturers‘ defined drift ............................... : --
G.9.2 Test Program 1 N/A
G.9.3 Test Program 2 N/A
G.9.4 Test Program 3 N/A
G.10 Resistors N/A
G.10.1 General requirements N/A
G.10.2 Resistor test N/A
G.10.3 Test for resistors serving as safeguards between the N/A
mains and an external circuit consisting of a coaxial
cable
G.10.3.1 General requirements N/A
G.10.3.2 Voltage surge test N/A
G.10.3.3 Impulse test N/A
G.11 Capacitor and RC units N/A
G.11.1 General requirements N/A
G.11.2 Conditioning of capacitors and RC units N/A

Page 27 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

G.11.3 Rules for selecting capacitors N/A


G.12 Optocouplers N/A
Optocouplers comply with IEC 60747-5-5:2007 See appended table 4.1.2. N/A
Spacing or Electric Strength Test (specify option and
test results) :
Type test voltage Vini ........................................ : --
Routine test voltage, Vini,b ................................ : --
G.13 Printed boards P

G.13.1 General requirements P


G.13.2 Uncoated printed boards P
G.13.3 Coated printed boards N/A
G.13.4 Insulation between conductors on the same inner N/A
surface
Compliance with cemented joint requirements (Specify --
construction)...................................................... :
G.13.5 Insulation between conductors on different surfaces N/A
Distance through insulation : (See appended table --
5.4.4.5)
Number of insulation layers (pcs) ...................... : --
G.13.6 Tests on coated printed boards N/A
G.13.6.1 Sample preparation and preliminary inspection N/A
G.13.6.2a) Thermal conditioning N/A
G.13.6.2b) Electric strength test N/A
G.13.6.2c) Abrasion resistance test N/A
G.14 Coating on components terminals N/A
G.14.1 Requirements : (See G.13) --
G.15 Liquid filled components N/A
G.15.1 General requirements N/A
G.15.2 Requirements N/A
G.15.3 Compliance and test methods N/A
G.15.3.1 Hydrostatic pressure test N/A
G.15.3.2 Creep resistance test N/A
G.15.3.3 Tubing and fittings compatibility test N/A
G.15.3.4 Vibration test N/A
G.15.3.5 Thermal cycling test N/A
G.15.3.6 Force test N/A

Page 28 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

G.15.4 Compliance N/A


G.16 IC including capacitor discharge function (ICX) N/A
a) Humidity treatment in accordance with sc5.4.8 – 120 N/A
hours
b) Impulse test using circuit 2 with Uc = to transient --
voltage ............................................................. :
C1) Application of ac voltage at 110% of rated voltage N/A
for 2.5 minutes
C2) Test voltage ...................................................... : --

D1) 10,000 cycles on and off using capacitor with smallest N/A
capacitance resistor with largest resistance specified
by manufacturer
D2) Capacitance ..................................................... : --
D3) Resistance ....................................................... : --

H Criteria for Telephone Ringing Signals N/A


H.1 General N/A
H.2 Method A N/A
H.3 Method B N/A
H.3.1 Ringing signal N/A
H.3.1.1 Frequency (Hz) : --
H.3.1.2 Voltage (V) : --
H.3.1.3 Cadence; time (s) and voltage (V) : --
H.3.1.4 Single fault current (mA): --
H.3.2 Tripping device and monitoring voltage --
H.3.2.1 Conditions for use of a tripping device or a monitoring N/A
voltage complied with
H.3.2.2 Tripping device N/A
H.3.2.3 Monitoring voltage (V) --

J Insulated Winding Wires for Use Without Interleaved Insulation N/A


General requirements See appended table 4.1.2. N/A

K Safety Interlocks N/A


K.1 General requirements N/A
K.2 Components of safety interlock safeguard mechanism (See Annex G) --
K.3 Inadvertent change of operating mode N/A

Page 29 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

K.4 Interlock safeguard override N/A


K.5 Fail-safe N/A
Compliance : (See appended table B.4) --
K.6 Mechanically operated safety interlocks N/A
K.6.1 Endurance requirement N/A
K.6.2 Compliance and Test method : --
K.7 Interlock circuit isolation N/A
K.7.1 Separation distance for contact gaps & interlock circuit --
elements (type and circuit location)
K.7.2 Overload test, Current (A) --
K.7.3 Endurance test N/A
K.7.4 Electric strength test (See appended table 5.4.11) --

L DISCONNECT DEVICES N/A


L.1 General requirements N/A
L.2 Permanently connected equipment N/A
L.3 Parts that remain energized N/A
L.4 Single phase equipment N/A
L.5 Three-phase equipment N/A
L.6 Switches as disconnect devices N/A
L.7 Plugs as disconnect devices N/A
L.8 Multiple power sources N/A

M Equipment Containing Batteries and Their Protection Circuits P


M.1 General requirements P
M.2 Safety of batteries and their cells P
M.2.1 Requirements P
M.2.2 Compliance and test method (identify method) ... : --
M.3 Protection circuits N/A
M.3.1 Requirements N/A
M.3.2 Tests N/A
- Overcharging of a rechargeable battery N/A
- Unintentional charging of a non-rechargeable battery N/A
- Reverse charging of a rechargeable battery N/A
- Excessive discharging rate for any battery N/A

Page 30 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

M.3.3 Compliance : (See appended Tables and --


Annex M and M.4)
M.4 Additional safeguards for equipment containing N/A
secondary lithium battery
M.4.1 General N/A
M.4.2 Charging safeguards N/A
M.4.2.1 Charging operating limits N/A
M.4.2.2a) Charging voltage, current and temperature (See Table M.4) --
M.4.2.2 b) Single faults in charging circuitry : (See Annex B.4) --
M.4.3 Fire Enclosure N/A
M.4.4 Endurance of equipment containing a secondary N/A
lithium battery
M.4.4.2 Preparation N/A
M.4.4.3 Drop and charge/discharge function tests N/A
Drop N/A
Charge N/A
Discharge N/A
M.4.4.4 Charge-discharge cycle test N/A
M.4.4.5 Result of charge-discharge cycle test N/A
M.5 Risk of burn due to short circuit during carrying N/A
M.5.1 Requirement N/A
M.5.2 Compliance and Test Method (Test of P.2.3) N/A
M.6 Prevention of short circuits and protection from other N/A
effects of electric current
M.6.1 Short circuits N/A
M.6.1.1 General requirements N/A
M.6.1.2 Test method to simulate an internal fault N/A
M.6.1.3 Compliance (Specify M.6.1.2 or alternative method) --
M.6.2 Leakage current (mA) ....................................... : --
M.7 Risk of explosion from lead acid and NiCd batteries N/A
M.7.1 Ventilation preventing explosive gas concentration N/A
M.7.2 Compliance and test method N/A
M.8 Protection against internal ignition from external spark N/A
sources of lead acid batteries
M.8.1 General requirements N/A
M.8.2 Test method N/A
M.8.2.1 General requirements N/A

Page 31 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

M.8.2.2 Estimation of hypothetical volume Vz (m3/s) ....... : --


M.8.2.3 Correction factors .............................................. : --
M.8.2.4 Calculation of distance d (mm) .......................... : --
M.9 Preventing electrolyte spillage N/A
M.9.1 Protection from electrolyte spillage N/A
M.9.2 Tray for preventing electrolyte spillage N/A
M.10 Instructions to prevent reasonably foreseeable misuse —
(Determination of compliance: inspection, data review;
or abnormal testing) .......................................... :
N Electrochemical Potentials N/A
Metal(s) used .................................................... : Pollution degree considered --
O Measurement of Creepage Distances and Clearances N/A
Figures O.1 to O.20 of this Annex applied ........... : --
P Safeguards Against Entry of Foreign Objects and Spillage of Internal Liquids P
P.1 General requirements P
P.2.2 Safeguards against entry of foreign object P
Location and Dimensions (mm) ................................... --
P.2.3 Safeguard against the consequences of entry of N/A
foreign object
P.2.3.1 Safeguards against the entry of a foreign object N/A
Openings in transportable equipment N/A
Transportable equipment with metalized plastic parts --
P.2.3.2 Openings in transportable equipment in relation to --
metallized parts of a barrier or enclosure (identification
of supplementary safeguard)
P.3 Safeguards against spillage of internal liquids N/A
P.3.1 General requirements N/A
P.3.2 Determination of spillage consequences N/A
P.3.3 Spillage safeguards N/A
P.3.4 Safeguards effectiveness N/A
P.4 Metallized coatings and adhesive securing parts N/A
P.4.2 a) Conditioning testing N/A
(IEC 60950-1, 4.6.5)
Tc (°C)............................................................... : --
Tr (°C) ............................................................... : --

Page 32 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

Ta (°C) .............................................................. : --
P.4.2 b) Abrasion testing ................................................ : (See G.13.6.2) --
P.4.2 c) Mechanical strength testing : (See Annex T) --
Q Circuits Intended for Interconnection with Building Wiring N/A
Q.1 Limited power sources N/A
Q.1.1 a) Inherently limited output N/A
Q.1.1 b) Impedance limited output N/A
- Regulating network limited output under normal N/A
operating and simulated single fault condition
Q.1.1 c) Overcurrent protective device limited output N/A
Q.1.1 d) IC current limiter complying with G.9 N/A
Q.1.2 Compliance and test method N/A
Q.2 Test for external circuits – paired conductor cable N/A
Maximum output current (A) : --
Current limiting method : --
R Limited Short Circuit Test N/A
R.1 General requirements N/A
R.2 Determination of the overcurrent protective device and N/A
circuit
R.3 Test method Supply voltage (V) and short-circuit --
current (A)). .................................................... :
S Tests for Resistance to Heat and Fire N/A
S.1 Flammability test for fire enclosures and fire barrier N/A
materials of equipment where the steady state power
does not exceed 4 000 W
Samples, material --
Wall thickness (mm) --
Conditioning (。C) --
Test flame according to IEC 60695-11-5 with N/A
conditions as set out
- Material not consumed completely N/A
- Material extinguishes within 30s N/A
- No burning of layer or wrapping tissue N/A
S.2 Flammability test for fire enclosure and fire barrier N/A
integrity
Samples, material --

Page 33 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

Wall thickness (mm) --


Conditioning (。C) --
Test flame according to IEC 60695-11-5 with N/A
conditions as set out
Test specimen does not show any additional hole N/A
S.3 Flammability test for the bottom of a fire enclosure N/A
(IEC 60950-1, A.3)
Samples, material --
Wall thickness (mm) --
Cheesecloth did not ignite N/A
S.4 Flammability classification of materials N/A
S.5 Flammability test for fire enclosures and fire barrier N/A
materials of equipment where the steady state power
does not exceed 4 000 W
Samples, material --
Wall thickness (mm) --
Conditioning (test condition), (。C) --
Test flame according to IEC 60695-11-20 with N/A
conditions as set out
After every test specimen was not consumed N/A
completely
After fifth flame application, flame extinguished within 1 N/A
min
T Mechanical Strength Tests P
T.1 General requirements P
T.2 Steady force test, 10 N (See appended table T.2) --
T.3 Steady force test, 30 N (See appended table T.3) --
T.4 Steady force test, 100 N (See appended table T.4) --
T.5 Steady force test, 250 N (See appended table T.5) --
T.6 Enclosure impact test (See appended table T.6) N/A
Fall test N/A
Swing test N/A
T.7 Drop test (See appended table T.7) N/A
T.8 Stress relief test (See appended table T.8) N/A
T.9 Impact Test (glass) N/A
T.9.1 General requirements N/A
T.9.2 Impact test and compliance N/A

Page 34 of 50
REPORT NO. PRSZ24091302S

IEC 62368-1 (ed.2)


Clause Requirement + Test Result - Remark Verdict

Impact energy (J) --


Height (m) --
T.10 Glass fragmentation test : (See sub-clause 4.4.4.9) --
T.11 Test for telescoping or rod antennas N/A
Torque value (Nm) --
U Mechanical Strength of Cathode Ray Tubes (CRT) and Protection Against The N/A
Efects of Implosion
U.1 General requirements N/A
U.2 Compliance and test method for non-intrinsically N/A
protected CRTs
U.3 Protective Screen (See Annex T) --
V Determination of Accessible Parts (Fingers, Probes and Wedges) N/A
V.1 Accessible parts of equipment N/A
V.2 Accessible part criterion N/A

Page 35 of 50
REPORT NO. PRSZ24091302S

4.1.2 TABLE: List of critical components P


Object / Manufacturer/ Type / model Technical data Standard Mark(s) of
1
part No. trademark conformity
PCB Various Various V-0 or better, UL 796 UL
min. 130oC

Plastic Various Various HB or UL 94 UL


enclosure better,
o
min.80 C
Adapter DELTA TLY2505-50 Input: 100- IEC/EN 62368 CE
ELECTROICS,INC 240V~,50/60
Hz, 0.6A;
Output:
5VDC,5A;
Class II
Battery UFX 60173 3.7Vdc, 250mAh IEC/EN 62133 CE

Supplementary information:
1)
Provided evidence ensures the agreed level of compliance.
2)
Description line content is optional. Mainline description needs to clearly detail the component used for
testing

4.8.4 TABLE: Lithium coin/button cell batteries mechanical tests N/A


(The following mechanical tests are conducted in the sequence noted.)
4.8.4.2 TABLE: Stress relief test —
Part Material Oven Temperature (°C) Comments
-- -- -- --
4.8.4.3 TABLE: Battery replacement test

Battery part no. .......................................................... -- —
Battery Installation/withdrawal Battery Installation/Removal Cycle Comments
1 --
2 --
3 --
4 --
-- 5 --
6 --
8 --
9 --
10 --
4.8.4.4 TABLE: Drop test

Impact Area Drop Distance Drop No. Observations

-- -- 1 --

-- -- 2 --

Page 36 of 50
REPORT NO. PRSZ24091302S

4.8.4 TABLE: Lithium coin/button cell batteries mechanical tests N/A


(The following mechanical tests are conducted in the sequence noted.)

-- -- 3 --
4.8.4.5 TABLE: Impact

Impacts per surface Surface tested Impact energy (Nm) Comments
-- -- -- --
-- -- -- --
4.8.4.6 TABLE: Crush test —
Test position Surface tested Crushing Force (N) Duration force
applied (s)

-- -- -- --
-- -- -- --
Supplementary information:

4.8.5 TABLE: Lithium coin/button cell batteries mechanical test result N/A
Test position Surface tested Force (N) Duration force
applied (s)

-- -- -- --
Supplementary information:

5.2 TABLE: Classification of electrical energy sources P


5.2.2.2 – Steady State Voltage and Current conditions
Parameters
No Supply Location (e.g.
circuit Test conditions U I ES Class
. Voltage
designation) Hz
(Vrms or Vpk) (Apk or Arms)
1 5VDC DC input Normal 5.01 -- --
Abnormal -- -- -- ES1
Single fault – -- -- --
SC/OC
5.2.2.3 - Capacitance Limits

Location (e.g. Parameters


No Supply
circuit Test conditions ES Class
. Voltage
designation) Capacitance, nF Upk (V)

-- -- -- Normal -- --
Abnormal -- --
--
Single fault – -- --
SC/OC
5.2.2.4 - Single Pulses

No Supply Location (e.g. Test conditions Parameters ES Class

Page 37 of 50
REPORT NO. PRSZ24091302S

5.2 TABLE: Classification of electrical energy sources P


. Voltage circuit
designation) Duration (ms) Upk (V) Ipk (mA)

-- -- -- Normal -- -- --
Abnormal -- -- --
--
Single fault – -- -- --
SC/OC
5.2.2.5 - Repetitive Pulses

Location (e.g. Parameters


No Supply
circuit Test conditions ES Class
. Voltage
designation) Off time (ms) Upk (V) Ipk (mA)

-- -- -- Normal -- -- --
Abnormal -- -- --
--
Single fault – -- -- --
SC/OC
Test Conditions: Normal - ; Abnormal -
Supplementary information: SC=Short Circuit, OC=Short Circuit

5.4.1.4, TABLE: Temperature measurements P


6.3.2, 9.0,
B.2.6
Supply voltage (V) ................... : Charging Model Discharging Model
5.02V 3.7V —
Ambient Tmin (。C) ..................... : 24.7 40.0 24.7 40.0

Ambient Tmax (。C) ..................... : 25.1 40.0 25.1 40.0

Tma (。C) .................................. : 40.0 40.0 40.0 40.0

T (。C) Allowed
Maximum measured temperature T of part/at: Tmax (。C)

DC jacket 35.4 50.3 -- -- Ref.


Battery 41.8 56.7 52.8 67.6 60
PCB near IC1 (Charging Base) 48.7 63.6 -- -- 130
PCB near IC2 (Charging Base) 55.1 70 -- -- 130
PCB near IC3 (Slim Pager System) 44.2 59.1 47.3 62.1 130
PCB near IC4 (Slim Pager System) 47.3 62.2 49.2 64.0 130
Plastic inside (Charging Base) 33.3 48.2 -- -- 77
Plastic outside (Charging Base) 29.8 44.7 -- -- 77
Plastic inside (Slim Pager System) -- -- 34.3 49.1 77
Plastic outside (Slim Pager System) -- -- 29.5 44.3 77
Ambient 25.1 40.0 25.2 40.0 Ref.
Page 38 of 50
REPORT NO. PRSZ24091302S

Abnormal condition:
Abnormal conditon applied:
Allowed
Maximum measured temperature T of part/at: T (。C) Tmax (。C)

-- -- -- -- -- --
-- -- -- -- -- --
Supplementary information:
t1 (°C) R1 (Ω) t2 (°C) R2 (Ω) T (。C) Allowed Insulation
Temperature T of winding: Tmax (。C) class
-- -- -- -- -- -- -- --
-- -- -- -- -- -- -- --
Supplementary information:
Note 1: Tma should be considered as directed by appliable requirement
Note 2: Tma is not included in assessment of Touch Temperatures (Clause 9)
1. The maximum ambient temperature (Tma) permitted by the manufacturer‘s specification is 40°C.
2. All values for T(°C) are re-calculated from Tamb respectively.
3. Winding components (providing safety isolation):
- Class 105 Tmax=100°C-10°C=90°C

5.4.1.8 TABLE: Working voltage measurement N/A


1
Location RMS voltage (V) Peak voltage (V) Frequency (kHz) Comments
-- -- -- -- --
Supplementary information: Note 1: Only for frequency above 30 kHz

5.4.1.10.2 TABLE: Vicat softening temperature of thermoplastics N/A


Penetration (mm) --

Object/ Part No./Material Manufacturer/trademark T softening (°C)
-- -- --
Supplementary information:

5.4.1.10.3 TABLE: Ball pressure test of thermoplastics N/A


Allowed impression diameter (mm) ............................ ≤ 2 mm

Object/Part No./Material Manufacturer/trademark Test temperature (。C) Impression diameter (mm)

-- -- -- --
Supplementary information:

5.4.2.2, TABLE: Minimum Clearances/Creepage distance N/A


5.4.2.4 and
5.4.3
3
Clearance (cl) and creepage Up U Frequenc Required cl Required cr
distance (cr) at/of/between: (V) r.m.s. y (kHz)
1
cl (mm) (mm) 2 cr (mm) (mm)
(V)
Page 39 of 50
REPORT NO. PRSZ24091302S

-- -- -- -- -- -- -- --
Supplementary information:
Note 1: Only for frequency above 30 kHz
Note 2: See table 5.4.2.4 if this is based on electric strength
test Note 3: Provide Material Group

5.4.2.3 TABLE: Minimum Clearances distances using required withstand voltage N/A
Overvoltage Category (OV) ....................................................................... II
Pollution Degree........................................................................................ 2
Clearance distanced between: Required withstand Required cl Measured cl (mm)
voltage (mm)
-- -- -- --
Supplementary information: 1) See appended table 5.4.2.2, 5.4.2.4 and 5.4.3 for measurements.

5.4.2.4 TABLE: Clearances based on electric strength test N/A


Test voltage applied between: Required cl Test voltage (kV) Breakdown
(mm) peak/ r.m.s. / d.c. Yes / No
-- -- -- --
Supplementary information:

5.4.4.2, TABLE: Distance through insulation measurements N/A


5.4.4.5 c)
5.4.4.9

Distance through insulation Peak voltage Frequency Material Required DTI


di at/of: (V) (kHz) DTI (mm)
(mm)
-- -- -- -- -- --
Supplementary information:
1. See appended table 4.1.2.

5.4.9 TABLE: Electric strength tests N/A


Test voltage applied between: Voltage shape Test voltage (V) Breakdown
(AC, DC) Yes / No
Functional:
-- -- -- --
Basic/supplementary:
Basic insualtion -- -- --
Reinforced:
-- -- -- --
-- -- -- --
Routine Tests:
-- -- -- --
Supplementary information: 1) See Supplementary information of appended table 5.4.4.9.

5.5.2.2 TABLE: Stored discharge on capacitors N/A

Page 40 of 50
REPORT NO. PRSZ24091302S

Supply Voltage (V), Test Operating Switch Measured Voltage ES Classification


Hz Location Condition position
(after 2 seconds)
(N, S)
On or off
-- -- -- -- -- --
Supplementary information:
X-capacitors installed for testing are:
□ bleeding resistor rating:
□ ICX:
Notes:
A. Test Location:
Phase to Neutral; Phase to Phase; Phase to Earth; and/or Neutral to Earth
B. Operating condition abbreviations:
N – Normal operating condition (e.g., normal operation, or open fuse); S –Single fault condition

5.6.6.2 TABLE: Resistance of protective conductors and terminations N/A


Accessible part Test current Duration Voltage drop Resistance
(A) (min) (V) (Ω)
-- -- -- -- --
Supplementary information:

5.7.2.2, TABLE: Earthed accessible conductive part N/A


5.7.4
Supply voltage ........................................................... -- —
Location Test conditions specified in 6.1 of Touch current
IEC 60990 or Fault Condition No (mA)
in IEC 60990 clause 6.2.2.1
through 6.2.2.8, except for 6.2.2.7
1 --
2* --
3 --
-- 4 --
5 --
6 --
8 --
Supplementary Information:
Notes:
[1] Supply voltage is the anticipated maximum Touch Voltage
[2] Earthed neutral conductor [Voltage differences less than 1% or more]
[3] Specify method used for measurement as described in IEC 60990 sub-clause 4.3
[4] IEC60990, sub-clause 6.2.2.7, Fault 7 not applicable.
[5] (*) IEC60990, sub-clause 6.2.2.2 is not applicable if switch or disconnect device (e.g.,
appliance coupler) provided.

6.2.2 TABLE: Electrical power sources (PS) measurements for classification P

Page 41 of 50
REPORT NO. PRSZ24091302S

Max Power after 3 s Max Power after 5 PS Classification


Source Description Measurement )
s*
Power (W) : 11.1723 11.1723
A DC input VA (V) ........... : 5.01 5.01 PS1
IA (A) ............ : 2.23 2.23
Supplementary Information:
(*) Measurement taken only when limits at 3 seconds exceed PS1 limits
All circuits within the equipment are considered as PS3. For output circuits see appended table Q.1.

6.2.3.1 TABLE: Determination of Potential Ignition Sources (Arcing PIS) N/A


Open circuit
voltage
Measured r.m.s
After 3 s current Calculated value Arcing PIS?
Location (Vp) (Irms) (Vp x Irms) Yes / No

-- -- -- -- --
Supplementary information:
An Arcing PIS requires a minimum of 50 V (peak) a.c. or d.c. An Arcing PIS is established when the
product of the open circuit voltage (Vp) and normal operating condition rms current (Irms) is greater than 15.
All conductors and devices are considered as PIS.

6.2.3.2 TABLE: Determination of Potential Ignition Sources (Resistive PIS) P


Protective Circuit,
Measured Measured Resistive
Operating Condition Regulator, or PTC
Circuit Location (x- wattage or VA wattage or VA PIS?
(Normal / Describe Operated?
y) During first 30 After 30 s (W /
Single Fault) Yes / No Yes/No
s (W / VA) VA)
(Comment)
All internal circuits -- -- -- Yes
/components -- (Declaration)
Supplementary Information:
All internal circuit are considered as resistive PIS
A combination of voltmeter, VA and ammeter IA may be used instead of a wattmeter.
If a separate voltmeter and ammeter are used, the product of (VAx IA) is used to determine Resistive
PIS classification.
A Resistive PIS: (a) dissipates more than 15 W, measured after 30 s of normal operation, or (b) under
single fault conditions has either a power exceeding 100 W measured immediately after the introduction of
the fault if electronic circuits, regulators or PTC devices are used, or has an available power exceeding 15
W measured 30 s after introduction of the fault.
All conductors and devices are considered as PIS.

8.5.5 TABLE: High Pressure Lamp N/A


Description Values Energy Source Classification
Lamp type .................................................... -- —
Manufacturer ................................................ -- —
Cat no. ......................................................... -- —

Page 42 of 50
REPORT NO. PRSZ24091302S

Pressure (cold) (MPa) ................................... -- MS_


Pressure (operating) (MPa) ........................... -- MS_
Operating time (minutes) ............................... -- —
Explosion method ......................................... -- —
Max particle length escaping enclosure (mm). -- MS_
Max particle length beyond 1 m (mm) ............ -- MS_
Overall result ............................................... --
Supplementary information:

B.2.5 TABLE: Input test P


U (V) I (A) I rated (A) P (W) P rated (W) Fuse No Ifuse (A) Condition/status
Charging mode:
For Switching Power
Supply:
5.01 2.23 5 11.1723 -- -- -- Un = 230 V~ / 50 Hz,
In = 0.132 A, Pn =
15.2 W.

--
Supplementary information:
EUT was powered by an approved POWER ADAPTER.

B.3 TABLE: Abnormal operating condition tests P


Ambient temperature (。C) ........................................................... : See blow

Power source for EUT: Manufacturer, model/type, output rating .. : See label

Component Abnormal Supply Test Fuse no. Fuse T- Te Observation
No. voltage, (V) time current, couple mp
Condition (ms) (A) .
(。
C)
No abvious
termpersture
Battery Reverse -- 7H -- -- -- -- riseoccured.
no damage,
no hazard.
Supplementary information:
Test table is provided to record abnormal and fault conditions for all applicable energy sources including
Thermal burn injury. Column ―Abnormal/Fault.‖ Specify if test condition by indicating ―Abnormal‖ then
the condition for a Clause B.3 test or ―Single Fault‖ then the condition for Clause B.4.

B.4 TABLE: Fault condition tests P


Ambient temperature (。C) ........................................................... : See blow

Power source for EUT: Manufacturer, model/type, output rating .. : See label

for Transmitter CS-1000T, powered by switching power supply

Page 43 of 50
REPORT NO. PRSZ24091302S

Component Fault Supply Test time Fuse no. Fuse T-couple Temp. Observation
No. voltage, (V) (ms) current, (。C)
Condition
(A)

Unit still
works
IC1 S-C 5.02V 10mins -- 0.001 . -- -- normally. No
damage, no
hazard

Unit worked
IC4 S-C 5.02V 10mins -- 0.001 -- -- normally. No
damage, no
hazard.

Charging mode:

Unit still
works
IC1 S-C 5.02V 10mins -- 0.03 . -- -- normally. No
damage, no
hazard
Discharging mode:

Unit still
works
IC1 S-C 4.2V 10mins -- 0.004 . -- -- normally. No
damage, no
hazard
Supplementary information: S-C=Short Circuit, O-C=Open Circuit, O-L=Over Load.
The Electric strength tests were successfully conducted after the completion of fault tests, no breakdown.
*) fuse current is more than 2.1 times fuse rating.

Annex M TABLE: Batteries P


The tests of Annex M are applicable only when appropriate battery data is not available --
Is it possible to install the battery in a reverse polarity position? ....................... -- --
Non-rechargeable batteries Rechargeable batteries
Discharging Un- Charging Discharging Reversed charging
intention
Meas. Manuf. al Meas. Manuf. Meas. Manu. Meas. Manuf.
current Specs. chargin current Specs. current Specs current Specs.
g .
Max. -- -- -- 32mA 50mA 33mA 125mA -- --
current
during
normal
condition
Max. -- -- -- 37mA 250mA 36mA 250mA -- --
current
during
Fault
condition

Page 44 of 50
REPORT NO. PRSZ24091302S

Test results: Verdict


- Chemical leaks P
- Explosion of the battery P
- Emission of flame or expulsion of molten metal P
- Electric strength tests of equipment after completion of tests N/A
Supplementary information:

Annex M.4 TABLE: Additional safeguards for equipment containing secondary lithium N/A
batteries

Battery/Cell Measurements
Test conditions Observation
No.
U I (A) Temp (C)
-- Normal -- -- -- --
-- Abnormal -- -- -- --
-- Single fault –SC/OC -- -- -- --
Supplementary Information:
Battery Charging at Tlowest Observation Charging at Thighest Observation
identification (。C) (。C)

-- -- -- -- --
Supplementary Information:

Annex Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) N/A
Note: Measured UOC (V) with all load circuits disconnected:
Output Components Uoc (V) Isc (A) S (VA)
Circuit
Meas. Limit Meas. Limit
-- -- -- -- -- -- --
Supplementary Information:
SC=Short circuit, OC=Open circuit

T.2, T.3, TABLE: Steady force test N/A


T.4, T.5

Part/Locatio Material Thickness Force Test Duration Observation


n (mm)
(N) (sec)

-- -- -- -- -- --
Supplementary information: 1. See appended table 4.1.2

T.6, T.9 TABLE: Impact tests N/A

Page 45 of 50
REPORT NO. PRSZ24091302S

Part/Location Material Thickness Vertical Observation


(mm) distance (mm)
-- -- -- -- --
Supplementary information:

T.7 TABLE: Drop tests N/A


Part/Location Material Thickness Drop Height Observation
(mm) (mm)
-- -- -- -- --
Supplementary information: 1. See appended table 4.1.2

T.8 TABLE: Stress relief test N/A

Part/Locatio Material Thickness Oven Duration Observation


n (mm) Temperature
(h)
(。C)

-- -- -- -- -- --
Supplementary information: 1. See appended table 4.1.2

Annex No. 1

Photo Documentation

Slim Pager System, CS-18QM


Page 46 of 50
REPORT NO. PRSZ24091302S

Transmitter and Charging Base, CS-4C:

Page 47 of 50
REPORT NO. PRSZ24091302S

Slim Pager System, CS-4LED:

Page 48 of 50
REPORT NO. PRSZ24091302S

Page 49 of 50
REPORT NO. PRSZ24091302S

Adapter, TLY2505-50

-End of Report-

Page 50 of 50

You might also like