Slim Pager System IEC 62368
Slim Pager System IEC 62368
PRSZ24091302S
Error: Reference source not found
TEST REPORT
IEC 62368-1
Audio/video, information and communication technology equipment
Part 1: Safety requirements
Report Number...............................: PRSZ24091302S
Compiled by (Name + Signature) . : Cathy Zhang
Report Number...............................: Sunny Ge
Date of issue...................................: September 13, 2024
Total number of pages...................: 50
Testing Laboratory.........................: Shenzhen PTSI Testing Co., Ltd.
2/F, Building C, Hongwan Commercial Center, Bao'an Road,
Address......................................... :
Xixiang, Baoan, Shenzhen, China
Testing Location / Address..........: Same as above
Applicant’s name...........................: Xiamen Jinchan Electronics Co., Ltd.
Address...........................................: Floor 8, No. 3, Zhongwan Road, Xinglin North Industrial, JiMei
District, XiaMen City, FuJian Province, China
Test specification:
Standard.........................................: IEC 62368-1:2023
Test procedure...............................: IEC
Non-standard test method............: N/A
TRF template used.........................: IECEE OD-2020-F1:2023, Ed.1.6
Test Report Form No.....................: IEC62368_1F
Test Report Form(s) Originator.....: UL Solutions (US)
Master TRF.....................................: Dated 2023-08-18
Test item description.......................: Slim Pager System
Trademark(s)....................................: N/A
Manufacturer....................................: Same as applicant
Model/Type reference......................: CS-18QM
Ratings..............................................: The Slim Pager System CS-18QM consists of one Transmitter
and charging base CS-4C, Slim Pager System CS-4LED and
Adapter TLY2505-50.
For Adapter (Model: TLY2505-50): Input: 100-240V~, 50/60Hz,
0.6A; Output: 5Vdc, 5A;
For Charging Base (Model: CS-4C): Input: 5Vdc, 5A; Output:
5Vdc;
For Slim Pager System (Model: CS-4LED): 5VDC; or Battery:
3.7Vdc, 250mAh
Summary of testing:
Tests performed (name of test, test clause and Testing location: (CBTL, SPTL, CTF,
date test performed): Subcontractor)
Full 2/F, Building C, Hongwan Commercial Center,
Bao'an Road, Xixiang, Baoan, Shenzhen, China
No decision rule is specified by the IEC standard, when comparing the measurement result with the
applicable limit according to the specification in that standard. The decisions on conformity are made
without applying the measurement uncertainty (“simple acceptance” decision rule, previously known as
“accuracy method”).
Other: … (to be specified, for example when required by the standard or client, or if national
accreditation requirements apply)
Charging Base
Model: CS-4C
Input: 5VDC, 5A
Model: CS-4LED
Input: 5VDC
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies).........................: Same as manufacturer
General product information and other remarks:
Slim Pager System, powered by Adapter. For indoor use only.
Product Descriptions
- The equipment is a system (Model: CS-18QM) which contains charging base (Model: CS-4C), adapter
(Model: TLY2505-50) and slim pager system (Model: CS-4LED).
- When the slim pager system CS-4LED was powered by charging base CS-4C, which was supplied by
AC/DC ADAPTER TLY2505-50, it would only be in charging mode without receiving the signal; when by
battery, it would only be in working mode without being charged.
The specified max. ambient temperature is +40℃.
Model difference:
--
Additional application considerations – (Considerations used to test a component or sub-assembly):
Modification: PRSZ20101003S.
The original Test Report Ref. No. PRSZ20101003S, dated September 23, 2022 was modified include
the following changes:
ES PS MS TS RS
REPORT NO. PRSZ24091302S
4 GENERAL REQUIREMENTS P
4.1.1 Acceptance of materials, components and
P
subassemblies
4.1.2 Use of components Components and
subassemblies which are
comply with the
requirements of this
standard or within the safety P
aspects of the relevant IEC
component standards.
See appended table 4.1.2.
4.1.3 Equipment design and construction P
4.1.15 Markings and instructions (See Annex F) P
4.4.4 Safeguard robustness P
4.4.4.2 Steady force tests (See Annex T.3, T.4, T.5) P
4.4.4.3 Drop tests (See Annex T.7) N/A
4.4.4.4 Impact tests (See Annex T.6) P
4.4.4.5 Internal accessible safeguard enclosure and barrier The external enclosure
tests cannot be opened without P
damaging the product.
4.4.4.6 Glass Impact tests No such glass used. N/A
4.4.4.7 Thermoplastic material tests (See Annex T.8) P
4.4.4.8 Air comprising a safeguard (See Annex T) N/A
4.4.4.9 Accessibility and safeguard effectiveness P
4.5 Explosion No explosion occurs during
normal/abnormal operation P
and single fault conditions
4.6 Fixing of conductors N/A
4.6.1 Fix conductors not to defeat a safeguard N/A
4.6.2 10 N force test applied to N/A
4.7 Equipment for direct insertion into mains socket –
N/A
outlets
4.7.2 Mains plug part complies with the relevant standard --
4.7.3 Torque (Nm) --
4.8 Products containing coin/button cell batteries N/A
4.8.2 Instructional safeguard N/A
4.8.3 Battery Compartment Construction N/A
Means to reduce the possibility of children removing
the battery N/A
Page 9 of 50
REPORT NO. PRSZ24091302S
Page 10 of 50
REPORT NO. PRSZ24091302S
Page 11 of 50
REPORT NO. PRSZ24091302S
Page 12 of 50
REPORT NO. PRSZ24091302S
5.5.2.2 Safeguards against capacitor discharge after (See appended table N/A
disconnection of a connector 5.5.2.2)
5.5.3 Transformers (See Annex G.5.3) N/A
5.5.4 Optocouplers (See sub-clause 5.4 or N/A
Annex G.12)
5.5.5 Relays (See Annex G.2) N/A
5.5.6 Resistors (See Annex G.10) N/A
5.5.7 SPD‘s (See Annex G.8) N/A
5.5.7.1 Use of an SPD connected to reliable earthing N/A
5.5.7.2 Use of an SPD between mains and protective earth N/A
5.5.8 Insulation between the mains and external circuit (See Annex G.10.3) N/A
consisting of a coaxial cable
5.6 Protective conductor N/A
5.6.2 Requirement for protective conductors N/A
5.6.2.1 General requirements N/A
5.6.2.2 Colour of insulation N/A
5.6.3 Requirement for protective earthing conductors N/A
Protective earthing conductor size (mm2) : N/A
5.6.4 Requirement for protective bonding conductors N/A
5.6.4.1 Protective bonding conductors N/A
Protective bonding conductor size (mm2). : N/A
Protective current rating (A) : N/A
5.6.4.3 Current limiting and overcurrent protective devices N/A
5.6.5 Terminals for protective conductors N/A
5.6.5.1 Requirement N/A
Conductor size (mm2), nominal thread diameter (mm) N/A
5.6.5.2 Corrosion N/A
5.6.6 Resistance of the protective system N/A
5.6.6.1 Requirements N/A
5.6.6.2 Test Method Resistance (Ω) : N/A
5.6.7 Reliable earthing N/A
5.7 Prospective touch voltage, touch current and N/A
protective conductor current
5.7.2 Measuring devices and networks N/A
5.7.2.1 Measurement of touch current (See appended table N/A
5.2.2.2)
5.7.2.2 Measurement of prospective touch voltage N/A
Page 13 of 50
REPORT NO. PRSZ24091302S
Page 14 of 50
REPORT NO. PRSZ24091302S
6.3.1 (a) No ignition and attainable temperature value less (See appended table --
than 90 % defined by ISO 871 or less than 300 。C for 5.4.1.4, 6.3.2, 9.0, B.2.6)
unknown materials............................................ :
6.3.1 (b) Combustible materials outside fire enclosure See appended table 4.1.2. --
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard Method Method of Control fire
spread used. See sub- P
clause 6.4.4 to 6.4.6.
6.4.2 Reduction of the likelihood of ignition under single fault
P
conditions in PS1 circuits
6.4.3 Reduction of the likelihood of ignition under single fault PS2
P
conditions in PS2 and PS3 circuits
6.4.3.1 General P
6.4.3.2 Supplementary Safeguards N/A
Special conditions if conductors on printed boards are
N/A
opened or peeled
6.4.3.3 Single Fault Conditions ................................ : (See appended table 6.4.3) --
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits P
6.4.5 Control of fire spread in PS2 circuits P
6.4.5.2 Supplementary safeguards (See appended tables 4.1.2
P
and Annex G)
6.4.6 Control of fire spread in PS3 circuit (See appended tables 4.1.2
N/A
and Annex G)
6.4.7 Separation of combustible materials from a PIS N/A
6.4.7.1 General (See tables 6.2.3.1 and
6.2.3.2) --
Page 15 of 50
REPORT NO. PRSZ24091302S
6.4.8.3.3 Top Openings in Fire Enclosure: dimensions (mm) PS1 and ES1 circuits. --
Openings not affect the
safety.
8 MECHANICALLY-CAUSED INJURY P
8.1 General P
8.2 Mechanical energy source classifications See Energy source P
identification and
classification table.
8.3 Safeguards against mechanical energy sources N/A
Page 16 of 50
REPORT NO. PRSZ24091302S
Applied Force --
8.6.2.3 Downward Force Test N/A
8.6.3 Relocation stability test N/A
Page 17 of 50
REPORT NO. PRSZ24091302S
Page 18 of 50
REPORT NO. PRSZ24091302S
Page 19 of 50
REPORT NO. PRSZ24091302S
Page 20 of 50
REPORT NO. PRSZ24091302S
Page 21 of 50
REPORT NO. PRSZ24091302S
Page 22 of 50
REPORT NO. PRSZ24091302S
Page 23 of 50
REPORT NO. PRSZ24091302S
Page 24 of 50
REPORT NO. PRSZ24091302S
Position ............................................................ : --
G.5.4.2 Test conditions N/A
G.5.4.3 Running overload test N/A
G.5.4.4 Locked-rotor overload test N/A
Test duration (days) .......................................... : --
Page 25 of 50
REPORT NO. PRSZ24091302S
Page 26 of 50
REPORT NO. PRSZ24091302S
Page 27 of 50
REPORT NO. PRSZ24091302S
Page 28 of 50
REPORT NO. PRSZ24091302S
D1) 10,000 cycles on and off using capacitor with smallest N/A
capacitance resistor with largest resistance specified
by manufacturer
D2) Capacitance ..................................................... : --
D3) Resistance ....................................................... : --
Page 29 of 50
REPORT NO. PRSZ24091302S
Page 30 of 50
REPORT NO. PRSZ24091302S
Page 31 of 50
REPORT NO. PRSZ24091302S
Page 32 of 50
REPORT NO. PRSZ24091302S
Ta (°C) .............................................................. : --
P.4.2 b) Abrasion testing ................................................ : (See G.13.6.2) --
P.4.2 c) Mechanical strength testing : (See Annex T) --
Q Circuits Intended for Interconnection with Building Wiring N/A
Q.1 Limited power sources N/A
Q.1.1 a) Inherently limited output N/A
Q.1.1 b) Impedance limited output N/A
- Regulating network limited output under normal N/A
operating and simulated single fault condition
Q.1.1 c) Overcurrent protective device limited output N/A
Q.1.1 d) IC current limiter complying with G.9 N/A
Q.1.2 Compliance and test method N/A
Q.2 Test for external circuits – paired conductor cable N/A
Maximum output current (A) : --
Current limiting method : --
R Limited Short Circuit Test N/A
R.1 General requirements N/A
R.2 Determination of the overcurrent protective device and N/A
circuit
R.3 Test method Supply voltage (V) and short-circuit --
current (A)). .................................................... :
S Tests for Resistance to Heat and Fire N/A
S.1 Flammability test for fire enclosures and fire barrier N/A
materials of equipment where the steady state power
does not exceed 4 000 W
Samples, material --
Wall thickness (mm) --
Conditioning (。C) --
Test flame according to IEC 60695-11-5 with N/A
conditions as set out
- Material not consumed completely N/A
- Material extinguishes within 30s N/A
- No burning of layer or wrapping tissue N/A
S.2 Flammability test for fire enclosure and fire barrier N/A
integrity
Samples, material --
Page 33 of 50
REPORT NO. PRSZ24091302S
Page 34 of 50
REPORT NO. PRSZ24091302S
Page 35 of 50
REPORT NO. PRSZ24091302S
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance.
2)
Description line content is optional. Mainline description needs to clearly detail the component used for
testing
-- -- 1 --
-- -- 2 --
Page 36 of 50
REPORT NO. PRSZ24091302S
-- -- 3 --
4.8.4.5 TABLE: Impact
—
Impacts per surface Surface tested Impact energy (Nm) Comments
-- -- -- --
-- -- -- --
4.8.4.6 TABLE: Crush test —
Test position Surface tested Crushing Force (N) Duration force
applied (s)
-- -- -- --
-- -- -- --
Supplementary information:
4.8.5 TABLE: Lithium coin/button cell batteries mechanical test result N/A
Test position Surface tested Force (N) Duration force
applied (s)
-- -- -- --
Supplementary information:
-- -- -- Normal -- --
Abnormal -- --
--
Single fault – -- --
SC/OC
5.2.2.4 - Single Pulses
Page 37 of 50
REPORT NO. PRSZ24091302S
-- -- -- Normal -- -- --
Abnormal -- -- --
--
Single fault – -- -- --
SC/OC
5.2.2.5 - Repetitive Pulses
-- -- -- Normal -- -- --
Abnormal -- -- --
--
Single fault – -- -- --
SC/OC
Test Conditions: Normal - ; Abnormal -
Supplementary information: SC=Short Circuit, OC=Short Circuit
Abnormal condition:
Abnormal conditon applied:
Allowed
Maximum measured temperature T of part/at: T (。C) Tmax (。C)
-- -- -- -- -- --
-- -- -- -- -- --
Supplementary information:
t1 (°C) R1 (Ω) t2 (°C) R2 (Ω) T (。C) Allowed Insulation
Temperature T of winding: Tmax (。C) class
-- -- -- -- -- -- -- --
-- -- -- -- -- -- -- --
Supplementary information:
Note 1: Tma should be considered as directed by appliable requirement
Note 2: Tma is not included in assessment of Touch Temperatures (Clause 9)
1. The maximum ambient temperature (Tma) permitted by the manufacturer‘s specification is 40°C.
2. All values for T(°C) are re-calculated from Tamb respectively.
3. Winding components (providing safety isolation):
- Class 105 Tmax=100°C-10°C=90°C
-- -- -- --
Supplementary information:
-- -- -- -- -- -- -- --
Supplementary information:
Note 1: Only for frequency above 30 kHz
Note 2: See table 5.4.2.4 if this is based on electric strength
test Note 3: Provide Material Group
5.4.2.3 TABLE: Minimum Clearances distances using required withstand voltage N/A
Overvoltage Category (OV) ....................................................................... II
Pollution Degree........................................................................................ 2
Clearance distanced between: Required withstand Required cl Measured cl (mm)
voltage (mm)
-- -- -- --
Supplementary information: 1) See appended table 5.4.2.2, 5.4.2.4 and 5.4.3 for measurements.
Page 40 of 50
REPORT NO. PRSZ24091302S
Page 41 of 50
REPORT NO. PRSZ24091302S
-- -- -- -- --
Supplementary information:
An Arcing PIS requires a minimum of 50 V (peak) a.c. or d.c. An Arcing PIS is established when the
product of the open circuit voltage (Vp) and normal operating condition rms current (Irms) is greater than 15.
All conductors and devices are considered as PIS.
Page 42 of 50
REPORT NO. PRSZ24091302S
--
Supplementary information:
EUT was powered by an approved POWER ADAPTER.
Page 43 of 50
REPORT NO. PRSZ24091302S
Component Fault Supply Test time Fuse no. Fuse T-couple Temp. Observation
No. voltage, (V) (ms) current, (。C)
Condition
(A)
Unit still
works
IC1 S-C 5.02V 10mins -- 0.001 . -- -- normally. No
damage, no
hazard
Unit worked
IC4 S-C 5.02V 10mins -- 0.001 -- -- normally. No
damage, no
hazard.
Charging mode:
Unit still
works
IC1 S-C 5.02V 10mins -- 0.03 . -- -- normally. No
damage, no
hazard
Discharging mode:
Unit still
works
IC1 S-C 4.2V 10mins -- 0.004 . -- -- normally. No
damage, no
hazard
Supplementary information: S-C=Short Circuit, O-C=Open Circuit, O-L=Over Load.
The Electric strength tests were successfully conducted after the completion of fault tests, no breakdown.
*) fuse current is more than 2.1 times fuse rating.
Page 44 of 50
REPORT NO. PRSZ24091302S
Annex M.4 TABLE: Additional safeguards for equipment containing secondary lithium N/A
batteries
Battery/Cell Measurements
Test conditions Observation
No.
U I (A) Temp (C)
-- Normal -- -- -- --
-- Abnormal -- -- -- --
-- Single fault –SC/OC -- -- -- --
Supplementary Information:
Battery Charging at Tlowest Observation Charging at Thighest Observation
identification (。C) (。C)
-- -- -- -- --
Supplementary Information:
Annex Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) N/A
Note: Measured UOC (V) with all load circuits disconnected:
Output Components Uoc (V) Isc (A) S (VA)
Circuit
Meas. Limit Meas. Limit
-- -- -- -- -- -- --
Supplementary Information:
SC=Short circuit, OC=Open circuit
-- -- -- -- -- --
Supplementary information: 1. See appended table 4.1.2
Page 45 of 50
REPORT NO. PRSZ24091302S
-- -- -- -- -- --
Supplementary information: 1. See appended table 4.1.2
Annex No. 1
Photo Documentation
Page 47 of 50
REPORT NO. PRSZ24091302S
Page 48 of 50
REPORT NO. PRSZ24091302S
Page 49 of 50
REPORT NO. PRSZ24091302S
Adapter, TLY2505-50
-End of Report-
Page 50 of 50