0% found this document useful (0 votes)
29 views27 pages

03-EcoSUI BB Coloring

The document provides detailed instructions for configuring the EcoSUI Busbar Coloring feature within the EcoStruXure Power Automation System, emphasizing safety and proper installation by qualified personnel. It outlines the necessary steps for setting up the TopoEngine module, including the creation and updating of configuration files, and the generation of XML files for electrical topology. Additionally, it includes guidance on defining topology nodes and the use of an Excel tool for managing configurations.

Uploaded by

gopetk.01
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views27 pages

03-EcoSUI BB Coloring

The document provides detailed instructions for configuring the EcoSUI Busbar Coloring feature within the EcoStruXure Power Automation System, emphasizing safety and proper installation by qualified personnel. It outlines the necessary steps for setting up the TopoEngine module, including the creation and updating of configuration files, and the generation of XML files for electrical topology. Additionally, it includes guidance on defining topology nodes and the use of an Excel tool for managing configurations.

Uploaded by

gopetk.01
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 27

EcoStruXure Power Automation System

EcoSUI Busbar Coloring


Digital Energy

Power Solutions Global Training


2020

Confidential Property of Schneider Electric Page 1


Internal
Safety Information

▪ It is advisable to read all the Safety


Information, all the time before trying to Install,
Operate, Service or Maintain it.
▪ Electrical equipment should be installed,
operated, serviced and maintained only by
qualified personnel.
▪ Work with facility IT System Administrators to
ensure that the system adheres to the site-
specific cybersecurity policies.
Refer to Official Technical Guides and
documentation related to the version installed.
Failure to follow these instructions can result in
death, serious injury, or equipment damage.

Confidential Property of Schneider Electric | Page 2


Internal
Introduction

Confidential Property of Schneider Electric Page 3


Internal
EcoSUI Bus Bar Coloring
The main purpose of TopoEngine module is to compute dynamically the electrical topology of an
electrical network.

The module is fed with:


- The static topology configuration (including all the conducting equipment)
- The electrical node definition (corresponding to the interconnection point between conduction equipments)
- The electrical state of the conducting equipment (energized/not energized for sources or voltage value, open/close
for switches, …)
- The voltage level whom conducting equipment belongs to.

Confidential Property of Schneider Electric Page 4


Internal
EcoSUI Bus Bar Coloring
This feature is based on a dedicated ring running a topological engine.

The topological engine that will import data from an xml file :
TopoEngineConf.xml

This feature needs also another ring for acquisition of datapoints used.

Confidential Property of Schneider Electric Page 5


Internal
Ring Configuration

Confidential Property of Schneider Electric Page 6


Internal
Ring TOPO - configuration
Create ring from example installed in C:\MCIS\Examples

Step 1 : Upate Ring.ini

Type = TOPO
Enabled = <PC name>

Step 2 : update TopoEngineConf.xml :


contains the list of electrical nodes and their primary electrical devices associated.

It contains
Nodes
Datapoints
conducting equipments

(Note: refer to Application note for information that each of these objects need )

Confidential Property of Schneider Electric Page 7


Internal
Ring TOPO - configuration
Example of TopoEngineConf.xml file :
<?xml version="1.0" encoding="utf-8"?>
<TopologyDefinitions xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<System />
<NodesDefinition>
<Node id="1" name="SITE | PLATEFORME_O&amp;G / 20 kV / HTA_AUTOMATISME / COULEUR / Node1">
<Datapoint norgInt="1151" meaning="Color Id" />
</Node>
<Node id="2" name="SITE / PLATEFORME_O&amp;G / 20 kV / HTA_AUTOMATISME / COULEUR / Node2">
<Datapoint norgInt="1161" meaning="Color Id" />
</Node>
</NodesDefinition>
<ConductingEquimentsDefinition>
<ConductingEquipement id="1" type="GEN" subType="GEN" nodeId1="1" nodeId2="-1" nodeId3="-1"
name="SITE / PLATEFORME_O&amp;G / 20 KV / HTA_TR1 / MESURES / V1" voltRef="20000.0">
<Datapoint norgInt="1504" meaning="State" />
</ConductingEquipement>
<ConductingEquipement id="9" type="CBR" nodeId1="1" nodeId2="2" nodeId3="-1" name="SITE /
PLATEFORME_O&amp;G | 63 kV | HTB | DJB | Position_DJ" voltRef="20000.0">
<Datapoint norgInt="1509" meaning="State" />
</ConductingEquipement>
</ConductingEquimentsDefinition>
</TopologyDefinitions>

Confidential Property of Schneider Electric Page 8


Internal
Ring TOPO – configuration with xls tool
Generation of TopoEngineConf xml file :
To generate this file on complex project use the topoEcoSUI v1.2.xlsm excel file
(in Ring_Example.zip in sub-directory BusbarColoring).

Complete only tabs;


“SignalList”
“Equipements”

They are needed to create the TopoEngineConf.xml.

The tab “Nodes” is generated after the “Extract Nodes” action.

(Note: refer to Application note for information that each of these objects need )

Confidential Property of Schneider Electric Page 9


Internal
Define Topology nodes - example
Node 0 is always Ground
Node 1 is the source

Node 101 connects Q8 to Q0


Node 102 connects Q0 to Q1 and Q2

Node 1000 is BB1


Node 2000 is BB2

Graphic Object Attributes :


Rectangle_Mnemonic 110_0 / NODE_101 COLOR
Rectangle_UseBusbarColor 1

Confidential Property of Schneider Electric Page 10


Internal
Ring TOPO – configuration with xls tool
use of topoEcoSUI v1.2.xlsm excel file

good practice : keep xls file used for current configuration in the Ring folder of EcoSUI PC

Follow steps listed in sheet ‘Equipments’

0. Delete the example by clicking on Clear button


1. Fill aside the voltage level of the project, with a dot "."

Confidential Property of Schneider Electric Page 11


Internal
Ring TOPO – configuration with xls tool
Copy your signal list in SignalList area in dedicated sheet
“SignalList” : put here all datapoints that you will use from your configuration
Example :
SS_01 / 110_KV / FEEDER 1 / Q0 / COMPUTED SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 1 / Q1 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 1 / Q2 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 1 / Q8 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 1 / Q9 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 1 / CT/VT MEASURANDS / VOLTAGE AB
SS_01 / 110_KV / FEEDER 2 / Q0 / COMPUTED SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 2 / Q1 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 2 / Q2 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 2 / Q8 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 2 / Q9 / SWITCHGEAR POSITION
SS_01 / 110_KV / FEEDER 2 / CT/VT MEASURANDS / VOLTAGE AB
SS_01 / 110_KV / BUS COUPLER / Q0 / COMPUTED SWITCHGEAR POSITION
SS_01 / 110_KV / BUS COUPLER / Q1 / SWITCHGEAR POSITION
SS_01 / 110_KV / BUS COUPLER / Q2 / SWITCHGEAR POSITION

Confidential Property of Schneider Electric Page 12


Internal
Ring TOPO – configuration with xls tool
use of topoEcoSUI v1.2.xlsm excel file :
Add sources : type = GEN ,
connected to only one node,
on last column, select from signallist MV datapoint that provide voltage value

Sources : (type GEN) from 1 to 23

Confidential Property of Schneider Electric Page 13


Internal
Ring TOPO – configuration with xls tool
topoEcoSUI v1.2.xlsm
2.Select the type of mnemonic required
3. If more device types are needed, more equipements can be listed in A column.
5. Fill this page table

Confidential Property of Schneider Electric Page 14


Internal
Ring TOPO – configuration with xls tool
6. Run Extract nodes and then Create xml. xml file will be created in this file folder

Confidential Property of Schneider Electric Page 15


Internal
Ring TOPO - configuration
Step 3:
Update busbarcoloring.ini file
ColorOrigin:
Voltagelevel : color defined per voltage level
Source : color defined per source
This file contains the color definition for states at each voltagelevel.
At least one voltage level defined with all states needed or one source path
(depends on ColorOrigin).

Step 4:
Update topoparams.ini file

This file contains the setting used to set up the behaviour of the module.

(Note: refer to Application note for information that each of these objects need )

Confidential Property of Schneider Electric Page 16


Internal
Ring Result
For each node defined in the configuration step, two datapoints will be added:
one will be a MV (integer)
one will be a String.

The MV (Color) will take the value of the color to be displayed coded as an integer
translating directly the hexadecimal representation of the color.

The String (Sources) datapoint will give directly the different sources connected to the node.

Confidential Property of Schneider Electric Page 17


Internal
Update SbusServer
In Ring Bus Bar Coloring :
stop ring
load TopoEngineConf.xml

Confidential Property of Schneider Electric Page 18


Internal
Update SbusServer
Check in State viewer , the datapoints for bus bar coloring :

Confidential Property of Schneider Electric Page 19


Internal
Define Topology nodes - example

Q9 node 1 node 2

Q8

node 101 node 201

Q0 Q0
node 102
node 202
node 301 node 302
Q1 Q2 Q1 Q2 Q1 Q2
node 1000 is BB1

node 2000 is BB2

Confidential Property of Schneider Electric Page 20


Internal
Run example
• Simulate with SCLViewer,
• Use 4 scenarii below to
initialize the system

Operate devices (open, close) to check Color updates …


Find the error in a node graphic configuration…

Confidential Property of Schneider Electric Page 21


Internal
Graphics Configuration

Confidential Property of Schneider Electric Page 22


Internal
SignalList
The type of control to animate the busbar is only the Rectange.
Two parameters have to be set.

Rectangle_UseBusbarcolor set to 1 for activate Busbar coloring


functions
Rectangle_Mnemonic (6) Datapoint_path + Color

•Rectangle_Mnemonic : The path define in the configuration step.


(i.e. PLATEFORME_O&G / 20 kV / HTA_AUTOMATISME / COULEUR / Node1 Color)
Note : The property Rectangle_Tooltip will be set automatically to the Rectangle with the path Datapoint_path + Sources
(i.e. PLATEFORME_O&G / 20 kV / HTA_AUTOMATISME / COULEUR / Node1 Sources).

Confidential Property of Schneider Electric Page 23


Internal
Documentation

Confidential Property of Schneider Electric Page 24


Internal
Documentation
Application Note E50 :
EcoSUI_BUSBAR_COLORING_EN_AN_H.pdf

BB_Coloring_spec_details.docx

Confidential Property of Schneider Electric Page 25


Internal
Thank You

Confidential Property of Schneider Electric Page 26


Internal
Confidential Property of Schneider Electric Page 27
Internal