OpeManualForCNC_E
OpeManualForCNC_E
3/7/2019
Operation manual
This operation manual explains the procedure to get Parameter file, system configuration
file and CNC ID file on CNC. The procedure is slightly different by CNC display size or
screen specification. Refer to the corresponding chapter.
Screen for 10.4” display unit Screen for 15” display unit Screen for iHMI
Fig. 1 For screen examples
5. Press the soft key [PARAMETER], then the parameter screen appears.
13. Press the soft key [SYSTEM], then the system configuration screen appears.
18. Press the continuous menu key until soft key [ID-INF] appears.
19. Press the soft key [ID-INF], then the CNC ID information screen appears.
Fig. 5 CNC ID information screen
20. Press the soft key [(OPRT)].
21. Press the soft key [F OUTPUT].
22. Press the soft key [EXEC].
23. Confirm that below files are there in USB memory or Memory card.
File name
Parameter CNC-PARA.TXT
System configuration SYS-CONF.TXT
CNC ID information CNCIDNUM.TXT
If the parameter No.20 is changed in the procedure No.7, operate from No.24 to No.26 as
follows,
25. Press the soft key [PARAMETER], then the parameter screen appears.
26. Set the original value to the parameter No.20 as noted.
5. Press the vertical soft key [PARAMETER], then the parameter screen appears.
6. Press the MDI switch on the machine operator’s panel or enter state emergency
stop.
7. When a USB memory is used, set “17” to the parameter No.20.
When a memory card is used, set “4” to the parameter No.20.
Note: Before to change the parameter No.20, note the original value.
8. Press the EDIT switch on the machine operator’s panel or enter state emergency
stop.
9. Press the horizontal soft key [F OUTPUT].
10. Press the horizontal soft key [EXEC].
12. Press the vertical soft key [NEXT PAGE] until vertical soft key [SYSTEM]
appears.
13. Press the vertical soft key [SYSTEM], then the CNC ID information screen
appears.
17. Press the vertical soft key [NEXT PAGE] until vertical soft key [ID-INF] appears.
18. Press the vertical soft key [ID-INF], then the system configuration screen
appears.
Fig. 9 CNC ID information screen
File name
Parameter CNC-PARA.TXT
System configuration SYS-CONF.TXT
CNC ID information CNCIDNUM.TXT
23. Press the vertical soft key [PARAMETER], then the parameter screen appears.
24. Set the original value to the parameter No.20 as noted.