0% found this document useful (0 votes)
14 views14 pages

Revised-ANNEX 1 - LOT 2 - Technical Specification All in Two Solar Street Lighting Lanterns and Torches

The document outlines the technical specifications for an 'All in Two' solar LED street lighting system, including components such as PV panels, battery storage, and lighting sources. It details performance parameters, materials, and standards required for each component, emphasizing quality, durability, and compliance with international standards. Additionally, it includes specifications for poles, maintenance, and project signboards, ensuring a comprehensive approach to the installation and operation of the solar lighting system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views14 pages

Revised-ANNEX 1 - LOT 2 - Technical Specification All in Two Solar Street Lighting Lanterns and Torches

The document outlines the technical specifications for an 'All in Two' solar LED street lighting system, including components such as PV panels, battery storage, and lighting sources. It details performance parameters, materials, and standards required for each component, emphasizing quality, durability, and compliance with international standards. Additionally, it includes specifications for poles, maintenance, and project signboards, ensuring a comprehensive approach to the installation and operation of the solar lighting system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 14

ANNEX 1 -LOT – 2: ALL IN TWO SOLAR LED STREET

LIGHTING, LANTERNS, AND TORCHES

Technical Specifications
Contents
1. ALL IN TWO SOLAR LED STREET LIGHTING SYSTEM 3
1.1. PV PANELS: 4
1.2. BATTERY STORAGE 4
1.3. LIGHTING SOURCE (LUMINARY) 5
1.4. CHARGE CONTROLLER AND ELECTRONICS 6
1.5. POLES 8
1.6. POLES MAINTENTANCE 8
1.7. PROJECT SIGN BOARDS 11
2. SOLAR KITS FOR EMERGENCY 12
A. 360 SOLAR LANTERNS: 12
B. SOLAR TORCH HOUSEHOLD LEVEL 12
C. SOLAR LANTERN + RADIO & MP3 12

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 2
1. ALL IN TWO SOLAR LED STREET LIGHTING SYSTEM
A Solar Light consist of LED luminary (LED, MPPT and along with battery of given capacity), PV
module, which is not with them in the same enclosure, it will be splatted over the LED luminary on
the top of lighting pole, necessary control electronics-interconnecting wires /cables, module
mounting structures and brackets to operate the load for dusk to dawn.
Broad Performance Parameters

a. All components shall be CE and RoHS complaint.


b. Bidders are advised to use high quality material and the latest available technology.
c. All in two design including LED lamp, batteries (storage system) and charge controller shall
be integrated in into single enclosure and the PV panel out of them and over the pole as
shown in the pic's, all of them are integrated together work as one unit.
d. Fully automatic operation, the light shall switch on in the evening and switch off in the
morning.
e. The system shall be able to withstand harsh weather and environmental conditions.
f. All accessories shall be supplied with each unit including but not limited to wiring, clips
and remote control and so on.
g. The system should have green and red indicators for charging and load cut respectively.
h. The system shall allow a dimming option, and this shall allow to definition of at least four levels
of illumination level 100 %, 75 % ,50 % and 30%.
i. Housing made of Aluminum
j. IP: not less than IP66.
k. The complete system including the pole should be able to withstand a wind speed of 150
km/Hour
l. The contractor should do third-party test reports for battery, lighting device, solar panel,
motion sensor verification of IP rating, pole…etc. as per applicable standards and instructions
by UNDP engineers.
m. Minimum required standards/ specifications are as follows:

No Item Description Specification


.
1 Type of Solar Street light All in Two Solar Street Light
(PV) + (LED, Battery and MPPT)
2 Rated power of LED Light ≥ 80W-40W, One-side Mono
3 Input voltage DC 24V
4 Lithium Battery ≥ 60-35 AH/ (LiFePo4) More Than 5Years Lifespan
5 Solar panel ≥ 200W/36V

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 3
6 LED chip type / (Super Brightness) Philips / Osram /Bridge lux 5050
7 Light distribution Bat-Wing
8 Efficiency ≥ 140lm/w
9 Timer 4 - period Energy Saving Mode
10 Beam angle To be suitable for led lamp and to give the ability
for directing PV panel to the south direction
11 Color temperature 4000K-5000K
12 CRI >75
13 IP rate At least IP66
14 IK IK08-IK09
15 LED life span 50,000 hours
16 Poles with 1.5m arm in each side 9M and 6M Height, Octagonal, Steel, Hot-Dip
Galvanized., Rust Proof, Resistant to Wind: ≥150KM/H,
17 Controller specification 15A-20A, IP 66 MPPT AC/DC Hybrid Controller
18 Working temperature - Humidity -10℃ to 65℃ - 10% to 90%RH

1.1.PV PANELS:
a. Rating shall be not less than mentioned in the above sizes or any other rating that fulfils the
duty station conditions.
b. It shall conform to IEC 61215, IEC 61730, IEC 61701, or equivalent standards
c. The junction box, if applicable, shall be IP67 and designed for long life and harsh
environmental conditions, it should have a provision for opening and replacing the cable if
required.
d. Each module shall have an individual serial number and nameplate.
e. Mono Crystalline.
f. Rated Power: ≥ 200W.
g. Optimum Operating Voltage (Vmp) 36.6V
h. Conversion Efficiency: ≥ 21%.
i. Junction Box: Rubble Sealed up to IP66 with MC4 Connector
j. Materials: A Grade Solar Cells + Anti-aging & high viscosity EVA + Double-sided fluorine TPT
+3.2mm tempered glass + waterproof junction box (bypass protection diodes built in) + high
strength anodized aluminium frame.
k. Working temperature: -10℃ to 65℃.
l. Working Humidity: 10% to 90%RH.

1.2.BATTERY STORAGE

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 4
a. Rating shall be not less than mentioned in the above sizes or any other rating that fulfil the
duty station conditions.
b. The lifecycle shall be not less than 3000 cycle @ 80 DoD.
c. Should comply with IEC 62133.
d. Type: Lithium Battery LiFePo4.
e. Voltage: 25.6V.
f. Capacity: ≥ 60AH/ 1536WH.
g. Self-Discharge (25℃): <3%/ month (20℃).
h. Box Material: Reinforced Aluminium Alloy Case.
i. Short cut Current: 40A Reaction time< 0.8ms.
j. Over current protection: 20A Reaction time < 2s.
k. Working temperature: -10℃ to 65℃.
l. Working Humidity: 10% to 90%RH.

1.3.LIGHTING SOURCE (LUMINARY)


a. Catalogue illustrations of luminaire proposed for each specified application.
b. Installation requirements.
c. Photometric curves and is lux diagrams for each luminaire with indication of minimum light
output ratio.
d. Certificate of Quality.
e. Test Report.
f. Material Safety Data Sheet.
g. LUMINAIRE DATA SHEETS:

 The luminaire data sheets define the quality and design/performance of all luminaires
which shall be supplied and installed, with locations and quantities as indicated on the
Drawings.
 IP (ingress protection) shall be defined for each area according to international
standards.
 External lighting to be equipped with motion detector or presence detector photocells
type: ABB, SCHNEIDER, SIEMENS, LEGRAND, MK (UK)

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 5
The light source shall be LED type, and it shall follow below:

a. The colour temperature should be in the range of 4000 – 5000 K;


b. The illumination should be uniform without dark bands or abrupt variations;
c. The lighting pattern of the luminary should be type II or type III to enable uniformity of the
light across the road
d. The lamps should be housed in an assembly suitable for outdoor installation;
e. IP rating shall be at least 66.
f. The total luminaire efficacy should not be less than 160 lumens per watt.
g. The LEDs used in the Luminaire should have lifetime more than 50,000 hr., in accordance
with IEC 62722-2-1.
h. Power consumption of the LED Luminaire / lamp unit shall be as detailed above.
i. The connecting wires used inside the luminaries, shall be low smoke halogen free, fire-
retardant beam cable.
j. Rated Power: ≥ 80W or 40W
k. LED chip type / (Super Brightness) Philips/Osram/Bridge lux 5050.
l. PIR/ Motion Sensor Detector: With On & Off switching Control.
m. Beam angle: To be suitable for led lamp and to give the ability for directing PV panel to the
south direction.
n. CRI >75
o. IK: IK08-IK09
p. Power Factor: ≥ 90%.
q. Working temperature: -10℃ to 65℃.
r. Working Humidity: 10% to 90%RH.
s. Materials: High-Pressure Die-Casting Aluminium. Corrosion Resistant.
t. Arms: 1x1.5m, 2.5mm thickness / 2x 0.85m, 2.1mm thickness, angle: 15 degrees,
Galvanization Hot Dip Galvanized ≥ 80mm, Coating ≥ 90mm, Powder Coating.
u. Standard and tests must comply: FCC, UL-LISTED, CE,TUV,ROHS, LM79, LM8

1.4.CHARGE CONTROLLER AND ELECTRONICS


the charge controller of a rating in accordance with the PV module, and it shall follow below:

a. High efficiency, heavy duty with MPPT AC/DC Hybrid Controller feature.
b. Solar controller should be MPPT type.

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 6
c. Timer: 4 - period Energy Saving Mode available. It should support property to automatically
change the lamp brightness in four stages 100 %, 70 % ,50 % and 30% of the full capacity.
The
duration of each stage before the automatic change from stage to other can be adjusted.
d. All data should be display, all operation modes for dimming options should be controlled by
wireless remote Control.
e. Wireless remote control.
f. Rating Current: ≥ 15A.
g. IP Rate: ≥ IP67.
h. Necessary wiring, switches and protection should be provided.
i. Should have protection against battery overcharge, deep discharge, and short circuit,
j. Adequate protection should be provided against battery reverse polarity.
k. Working temperature: -10℃ to 65℃.
l. Remote Controller should be enabled to explorer at least 30 days’ history of whole system
m. running status, like:
 Discharging level.
 Discharging Time.
 Full charge time.
 Battery voltage.
 Performance Status.
 All system parameters.
n. Protection Functions:
 Short-circuit Protection: Once the load is short-circuiting connected, the controller must
shut itself off to protect the solar system from damage.
 Reverse Discharging Protection: It prevents the battery from discharging to solar panel.
 Polarity Protection: It protects from reversed connection. When polarities (+ and -) are
reversed the controller must shut itself off to protect the solar system from damage.
 Lightning Protection: It generally protects the solar system from damage caused by
lightning
 Low Voltage load cut-off protection: If the battery voltage sags 23V, the controller will
shut off the load to protect the battery from over-discharging.
 Over-charge Protection: The controller will adjust the charging rate according to ambient
 temperature to make sure battery is not only fully charged but also non-over-charged.

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 7
o. M. Fully automatic operation:
 Detects day and night by sensor on the PV array.
 Turn on/off the lamp according to ambient light or pre-setting.
 Temperature compensation with external temperature sensor.
p. The System must have Physical Switch for safe charging over sees and easy for maintenance,
Circuit Breakers, Box Size:200*88*90mm, Applicable cable:4*4 -10mm² IP Rate: ≥ IP67

1.5.POLES
a. Type: Octagonal Poles.
b. Material: Q235 Steel
c. Hot Dipped Galvanized
d. Powder Coating
e. Thickness: 5mm
f. Bottom/Top Diameter: 200/92mm
g. Flange: 400*400*20mm
h. Foundation Kit: 24*400*1500mm
i. Resistant to Wind: ≥150KM/H.
j. Rust Proof.

1.6.POLES MAINTENTANCE
a. Maintaining of the existing lighting poles Arms, and Foundation Kit
b. The price includes repair/maintain damaged or removed parts and covers
c. it includes smoothing & cleaning all pole parts, painting with two thick layers of rust-
resistant primer, then two layers of acrylic paint in colours specified by the consulting
engineer.

5.15 Reinforced Concrete Base :


The Regular and reinforced concrete works as the following:

a. Digging for the soil of the bases and bases with the dimensions indicated in the drawings and
not less than 80 cm from the ground level. The work includes cleaning the hole and
maintaining the sides of the excavation according to the drawings, specifications, and
instructions of the supervising engineer.
b. Supplying and executing ordinary concrete, thickness of 10 cm below the bases, using
salt-resistant Portland cement, with a resistance of not less than 200 kg / cm2 after 28

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 8
days, and a mixing ratio of (1: 1.5: 3) (cement: Nice: Cree), and the price includes
carpentry, spraying and all that is necessary To finish the work in accordance with the
drawings, specifications and instructions of the supervising engineer.
c. Supply and construction of reinforced concrete Bases. The concrete’s compressive
strength shall not be less than (300 kg/cm2) after 28 days of pouring. The price includes
the price of embedding, rebar and all that is needed to finish the work in accordance with
the drawings, specifications, and instructions of the supervising engineer.
d. Supplying and pouring grouts between the columns and the concrete base according to
the specifications and the price includes everything needed to finish the work according
to the drawings, specifications, and instructions of the supervising engineer
e. Supplying and installing earthing for poles, and the price includes coal, salt and everything
needed to finish the work according to the specifications and instructions of the
supervising engineer.

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 9
LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 10
LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 11
1.7.PROJECT SIGN BOARDS

 project signboard as follow template.


 material similar to specified large sign support.
 The information will be written in Arabic and English Languages
 any other information instructed by the Employer/Engineer.

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 12
2. SOLAR KITS FOR EMERGENCY

A. 360 SOLAR LANTERNS:


- Portable lanterns shall be integrated rechargeable units comprising of LED Lamp, battery
storage and associated control.
- The lantern shall be suitable for charging 12V DC supply through an appropriate jack.
- The lantern shall provide 360-degree coverage with 400 lumens for a minimum of 12 hours
/day.
- The lamp shall be 7W LED or equivalent.
- The batteries shall be Li-ion type 4000 to 6000 mAh or lead acid type with minimum of 7.0AH
at 12V
- The lantern shall provide indications of the status of the battery conditions. It shall be
protected for reverse polarity.
- The lantern shall be supplied with split charging unit (not less than 10Wp PV crystalline
module with cable not less than 4m).
- Solar lantern should be supporting the USB input.
- A strip containing the following details should be laminated inside the module so as to be
clearly visible from the front side.
- Name of the Manufacturer or distinctive logo. Model or Type No. Serial No.

B. SOLAR TORCH HOUSEHOLD LEVEL


- Solar torch shall be integrated unit comprising of LED Lamp and battery storage.
- Solar torch should be support mainly charging by external solar panel and AC charging input.
- The lamp should be LED with luminous not less than 100lm for 8 hours
- The integrated battery should be lithium- ion not less than 2500mAh/ 3.7V
- Solar torch should be support input charging minimum DC 5V/700mA.
- Solar torch unit should be consisting Split solar panel at least 3 watts, polycrystalline with
cable at least 4 meters.

C. SOLAR LANTERN + RADIO & MP3


- Portable lanterns shall be integrated rechargeable units comprising of LED Lamp, battery
storage FM radio and MP3 input.
- The lantern shall be suitable for charging 12V DC supply through an appropriate jack.
- The lamp shall be 3W LED or equivalent.

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 13
- The batteries shall be lead acid type with minimum of 9.0AH at 12V
- The lantern shall be supplied with split charging unit (20Wp PV crystalline module with cable
not less than 4m).

WARRANTY for all equipment


The PV module will be warranted for a minimum period of 10 years from the date of supply and
the lantern (including the battery) will be warranted for a minimum period of two years from the
date of supply.

LOT – 2: ALL IN TWO SOLAR LED STREET LIGHTING, LANTERNS, AND TORCHES 14