0% found this document useful (0 votes)
7 views1 page

Genset Range 50hz

The document provides specifications for diesel and gas generating sets, including power outputs, voltage ratings, and operating conditions according to ISO 8528 standards. It details prime and standby power ratings, engine models, and alternator characteristics, along with various configurations and their corresponding power capacities. Additionally, it includes information on engine types, cooling methods, and control systems for the generating sets.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views1 page

Genset Range 50hz

The document provides specifications for diesel and gas generating sets, including power outputs, voltage ratings, and operating conditions according to ISO 8528 standards. It details prime and standby power ratings, engine models, and alternator characteristics, along with various configurations and their corresponding power capacities. Additionally, it includes information on engine types, cooling methods, and control systems for the generating sets.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Diesel and Gas Generating Sets

Power outputs are to ISO 8528


Voltage (50 Hz)
single phase: 220-230-240 V
50 Hz
three-phase: 380/220, 400/230, 415/240 V
Power Factor: single-phase: 1.0 pf; three-phase: Diesel Gas
0.8 pf.
Genset Rating Definitions to ISO 8528-1 Air-cooled Liquid-cooled
Operating Conditions: A standard generating set
is designed to operate in environmental conditions
not exceeding an air inlet temperature of 25°C
(77°F), altitude (above sea level) 152.4 metres
(500 feet) and a relative humidity of 60%.
Prime Power: This rating is for the supply of
continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no
limitation on the annual hours of operation and
10% overload power can be supplied for 1 hour
in 12 hours.
Standby Power: This rating is for the supply of
continuous electrical power (at variable load) in LISTER-PACK AD1 HSL open set HSL and LLD (ALPHA ) acoustic set LLD (ALPHA ) open sets SIGMA DELTA acoustic set GAMMA acoustic set LLO (OMEGA) open set GS (ALPHA) gas genset
the event of a utility power failure. No overload
is permitted.
Engine series ZETA ZETA AD TR ALPHA SIGMA DELTA GAMMA OMEGA ALPHA
HSL HSL HSL HSL HSL HSL LLD LLD LLD LLD LLD LLD LLD LLD LLD LLD LLD LLD LLS LLS LLS LLS LLS LLS LLD LLD LLG LLG LLG LLG LLG LLG LLG LLG LLG LLG
Genset Model code LLP 2.8 LLP 4.5 AD1 LLO 100 LLO 200 GS 10N GS 12P GS 15N GS 17P
8 8A 15 15A 24 24A 95 95A 135 140 140A 200 190 190A 275 250 250A 400 20 20A 25 25A 30 30A 410 410A 50 50A 70 70A 100 100A 110 110A 140 140A
Type
Open set = O; acoustic set = A A A O O A O A O A O A O O A O O A O O A O O A O A O A O A O A O A O A O A O A O A O A O A O A O A O A
2 LPW LPWG4
Engine model ZA296 ZA418 AD1 TR1 TR1 TR2 TR2 TR3 TR3 LPW(S)2 LPW(S)3 LPW(S)4 LPW(S)T4 SW20 SW25 SW30 DWS4 GW4 GWT4 GWT6-1A GWT6-2A GWTA6 OWT6 OWTA6 LPWG3 LPWG3 LPWG4
T4 LPWG4

kVA 4.1 4.1 8.6 8.6 14.0 14.0 5.6 5.6 8.7 8.7 12.2 12.2 16.1 16.1 18.3 18.3 20.9 20.9 6.4 6.4 8.0 8.0 8.4 8.4 10.8 10.8
Prime
Single kWe 4.1 4.1 8.6 8.6 14.0 14.0 5.6 5.6 8.7 8.7 12.2 12.2 16.1 16.1 18.3 18.3 20.9 20.9 6.4 6.4 8.0 8.0 8.4 8.4 10.8 10.8
phase kVA 4.5 4.5 9.4 9.4 15.4 15.4 6.1 6.1 9.5 9.5 13.5 13.5 17.7 17.7 20.1 20.1 23.0 23.0 7.0 7.0 8.8 8.8 9.3 9.3 11.9 11.9
Standby
1500 kWe 4.5 4.5 9.4 9.4 15.4 15.4 6.1 6.1 9.5 9.5 13.5 13.5 17.7 17.7 20.1 20.1 23.0 23.0 7.0 7.0 8.8 8.8 9.3 9.3 11.9 11.9
r/min kVA 5.3 5.3 11.2 11.2 18.1 18.1 7.0 7.0 10.9 10.9 15.0 15.0 20.0 20.0 20 20 25 25 30 30 30.0 30.0 38 38 63 63 90 90 100 100 125 125 100-150 175-225 9.3 9.3 11.6 11.6 12.4 12.4 15.8 15.8
Prime
Three kWe 4.3 4.3 9.0 9.0 14.5 14.5 5.6 5.6 8.7 8.7 12.0 12.0 16.0 16.0 16 16 20 20 24 24 24.0 24.0 30 30 50 50 72 72 80 80 100 100 80-120 140-180 7.4 7.4 9.3 9.3 9.9 9.9 12.6 12.6
phase kVA 5.9 5.9 12.3 12.3 19.9 19.9 7.6 7.6 12.0 12.0 16.5 16.5 22.0 22.0 22 22 28 28 33 33 33.0 33.0 42 42 69 69 100 100 110 110 138 138 110-165 193-248 10.1 10.1 12.8 12.8 13.7 13.7 17.3 17.3
50 Hz Standby
kWe 4.7 4.7 9.9 9.9 15.9 15.9 6.1 6.1 9.6 9.6 13.2 13.2 17.6 17.6 18 18 22 22 26 26 26.4 26.4 33 33 55 55 80 80 88 88 110 110 88-132 154-198 8.1 8.1 10.2 10.2 10.9 10.9 13.8 13.8
Single Prime kVA/kWe 2.8 4.5 4.0 10.2 15.4 20.9
phase Standby kVA/kWe 3.1 5.0 4.4 11.2 16.9 23.0
3000 kVA 13.7 20.3 28.1 39.5
r/min Prime
(1) Three kWe 11.0 16.3 22.5 31.6
phase kVA 15.1 22.4 30.9 43.5
Standby
kWe 12.1 17.9 24.8 34.8

Cylinders Number of cylinders 1 1 1 1 1 2 2 3 3 2 2 2 3 3 3 4 4 4 4 4 4 3 3 3 3 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 3 3 3 3 4 4 4 4


Injection D-direct, I=indirect D D D D D D D D D D(I) D(I) D(I) D(I) D(I) D(I) D(I) D(I) D(I) D (I) D D D D D D D D I I D D D D D D D D D D D D D D N/A: Spark ignition
Engine N=natural T=turbo
Aspiration N N N N N N N N N N N N N N N N N N T T T N N N N N N N N N N T T T T T T T, I T, I T T T, I T, I N N N N N N N N
I=intercooled
M=mechanical,
Governing M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M E E Electro-mechanical E E E E E E E E
E=electronic

Single bearing, brushless, solid


Yes Yes
Alternator state AVR, class H insulation, IP21-3 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Class B Class B
protection
Leads only
Battery Battery and leads supplied Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Leads only Leads only Leads only Leads only Leads only Leads only Leads only Leads only Leads only
(two batteries required)
Electronic digital control module,
Yes (No remote Yes (No remote Yes: main and auxiliary
Control automatic shutdown protection, No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
or AMF) or AMF) LCDs
System manual/remote or AMF modes
Emergency stop button(s) No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Option Option Option Option
Noise dBA at 1 m N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 77 N/D 77 N/D 76 N/D 76 N/D 76 80 N/D N/D N/D N/D
At 75% load N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D
Rating dBA at 7 m 78 78 N/D 64 64 64 64 64 65 623 63 65 65 70 N/D 66 N/D 66 N/D 66 N/D 66 N/D 66 70 N/D 65 N/D 65 N/D 66 N/D 66
E=engine-mounted, R=residential,
Silencers R R N/D E (R) R E (R) R E (R) R E (R) R E (R) E (R) R E (R) E (R) R E (R) E (R) R E (R) (E) R (E) R (E) R E R (E) R (E) R (E) R (E) R (E) R (E) R (E) R E. R E R E R E R
( )=optional

kg 140 158 125 358 555 428 625 518 715 396 500 396 417 540 417 456 580 456 466 590 466 710 936 829 1183 877 1231 592 820 1193 1686 1431 1921 1860 2493 1860 2493 1876 2509 2381 3128 2734 3481 290 367 290 367 417 513 417 513
Weight
lb 308 348 275 789 1224 943 1378 1142 1576 873 1102 873 919 1190 919 1005 1279 1005 1027 1301 1027 1565 2064 1828 2608 1933 2714 1305 1808 2630 3717 3155 4235 4101 5496 4101 5496 4136 5531 5249 6896 6027 7674 640 810 640 810 920 1130 920 1130
mm 830 910 760 1442 1693 1442 1693 1442 1693 1442 1693 1442 1442 1693 1442 1442 1693 1442 1442 1693 1442 1626 1945 1830 2255 1830 2255 1600 2000 2200 2645 2200 2645 2640 3366 2640 3366 2640 3366 3783 4247 3783 4247 1480 1693 1480 1693 1480 1693 1480 1693
Length
in 32 35 29.9 56.8 56.8 56.8 66.6 56.8 66.6 56.8 66.6 56.8 56.8 66.6 56.8 56.8 66.6 56.8 56.8 66.6 56.8 64.0 76.6 72.1 88.8 72.1 88.8 63.0 78.9 86.6 104.1 86.6 104.1 103.9 132.5 103.9 132.5 103.9 132.5 148.9 167.2 148.9167.2 58.3 66.6 58.3 66.6 58.3 66.6 58.3 66.6
mm 532 532 480 715 743 715 743 715 743 715 743 715 715 743 715 715 743 715 715 743 715 840 840 900 900 900 900 700 850 996 1000 996 1000 1093 1100 1093 1100 1093 1100 1094 1100 1094 1100 711 743 711 743 711 743 711 743
Width
in 20 20 18.9 28.1 29.2 28.1 29.2 28.1 29.2 28.1 29.2 28.1 28.1 29.2 28.1 28.1 29.2 28.1 28.1 29.2 28.1 33.1 33.1 35.4 35.4 35.4 35.4 27.5 33.5 39.2 39.4 39.2 39.4 43.0 43.3 43.0 43.3 43.0 43.3 43.1 43.3 43.1 43.3 28 29.2 28 29.2 28 29.2 28 29.2
mm 740 740 600 1020 1143 1020 1143 1020 1143 997 1143 997 997 1143 997 997 1143 997 997 1143 997 1204 1376 1378 1590 1378 1590 1110 1300 1527 1643 1527 1643 1677 1949 1677 1949 1677 1949 1550 2070 1550 2070 1029 1143 1029 1143 1029 1143 1029 1143
Height
in 29 29 23.6 40.2 45.0 40.2 45.0 40.2 45.0 39.3 45.0 39.3 39.3 45.0 39.3 39.3 45.0 39.3 39.3 45.0 39.3 47.4 54.2 54.3 62.6 54.3 62.6 43.7 51.1 60.1 64.7 60.1 64.7 66.0 76.7 66.0 76.7 66.0 76.7 61.0 81.5 61.0 81.5 40.5 45.0 40.5 45.0 40.5 45.0 40.5 45.0

Lister Petter alternators are standard. (1) 50 Hz, 3000 r/min outputs are based on Mecc Alte Alternators.
Emissions Compliance: Key to Colour Coding N/A = not applicable (2) Weight and dimensions for LPWST4 vary from LPWT4
Compliant in EU and India (LPWS option N/D = no data available (3) 59.2 dBA for LPWST4 P027-08069 © Lister Petter Limited, 02/12/2009
Compliant in EU only TBA = to be announced
required for compliance in India)