The document details observations and improvements regarding flue gas outlet temperatures from economizers of various boilers. For Boiler 5701, the temperature improved from 213°C to 168°C; Boiler 9423 saw a drop from 197°C to 148°C; and Boiler 9422 decreased from 171°C to 144°C. Additionally, Boiler 6303's temperature was reduced from 182°C to 162°C, indicating successful heat recovery efforts across the observed boilers.

Uploaded by

Phoenix Blaze
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views

Photo

The document details observations and improvements regarding flue gas outlet temperatures from economizers of various boilers. For Boiler 5701, the temperature improved from 213°C to 168°C; Boiler 9423 saw a drop from 197°C to 148°C; and Boiler 9422 decreased from 171°C to 144°C. Additionally, Boiler 6303's temperature was reduced from 182°C to 162°C, indicating successful heat recovery efforts across the observed boilers.

Uploaded by

Phoenix Blaze
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CAP 05: Heat Recovery from flue gas of Boilers

Date: 12th June, 2024


Title: Boiler 5701 (8T)

Analog Temperature
Gauge at economizer
outlet.

CAP Observation & Improvement Temperature Gauge (Economizer Out)


Observation:
During the plant visit flue gas outlet temperature from
the economizer was measured to be 213°C.

Improvement Result:
The current outlet temperature of the flue gas is
measured at 168°C. The overall outlet temperature
variation is ranged within 165°C – 168°C.

Temperature Gauge
Reading: 168°C

Title: Boiler 9423 (5T)

Probe Insert points are


point are on economizer
body
CAP Observation & Improvement Temperature Probe Point (Economizer Out)
Observation:
During the plant visit flue gas outlet temperature from
the economizer was measured to be 197°C.

Improvement Result:
We used temperature probe to measure flue gas outlet
temperature. Which was measured to be around 148°C.

Outlet Probe Insert point:


Measured data recorded at 148°C

Title: Boiler 9422 (4T)

Analog Temperature
Meter at Economizer
Outlet

CAP Observation & Improvement Temperature Gauge (Economizer Out)


Observation:
During the plant visit flue gas outlet temperature from
the economizer was measured to be 171°C.

Improvement Result:
The current outlet temperature of the flue gas is
measured at 144°C. The overall outlet temperature
variation is ranged within 141°C – 145°C.

Temperature reading: 144°C


CAP 06: Heat Recovery from exhaust of WHRB
Date: 12th June, 2024
Title: Boiler 6303 (2.45T)

CAP Observation & Improvement Temperature Gauge (Economizer Out)


Observation:
During the plant visit flue gas outlet temperature from
the economizer was measured to be 182°C.

Improvement Result:
We used temperature probe to measure flue gas outlet
temperature. Which was measured to be around 162°C

Outlet Probe Insert point:


Measured data recorded at 162°C