The document is a comments resolution sheet for the EPC works related to the installation of skimmed oil pumps for Vedanta Limited's IW Tank Modification Projects. It outlines client comments, vendor responses, and updates made to the pump datasheet, including technical specifications and performance data. The document is marked for closure upon receipt of client comments.

Uploaded by

750arvind
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views7 pages

CS M283SMK1M42 MPT M DS 1001 A3 Code 1

The document is a comments resolution sheet for the EPC works related to the installation of skimmed oil pumps for Vedanta Limited's IW Tank Modification Projects. It outlines client comments, vendor responses, and updates made to the pump datasheet, including technical specifications and performance data. The document is marked for closure upon receipt of client comments.

Uploaded by

750arvind
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

COMMENTS RESOLUTION SHEET

Project PROVISION FOR EPC WORKS FOR IW, PF PUMP INSTALLATION & PC WORK FOR IW TANK MODIFICATION PROJECTS
Client Name VEDANTA LIMITED - Cairn Oil & Gas
EPC Consultant S.MARK ENGINEERING (I) PRIVATE LTD
CIL’s PO No. / Contract No. 8500003351
Vendor / Supplier Name RUHRPUMPEN
CIL’s PO No. to Vendor
Document No. Rev. M283SMK1M42-MPT-M-DS-1001_A3
Doc. Title DATA SHEET OF SKIMMED OIL PUMP
Review Code Code-2
Reply Required Yes

Page No./ Clause S.MARK


Sr. No Rev. CLIENT Comments Remark
No. Response
1 A2 Kindly mention referred documents Noted & Updated

2 A2 Update the tag no as per PID "M283GNR2-MPT-P-PID-1001-01" Noted & Updated


3 A2 Mention API standard with latest edition Noted & Updated
As per "M283GNR2-MPT-M-DS-0001"
refer note 10, MCSF value need to be
As per "M283GNR2-MPT-M-DS-0001" the required flow rate is
4 A2 added in flow rate and MCSF value is
18m3/hr;Also mention normal and max flow rates
5.71. Hence updated flow rate is
23.71m3/hr
5 A2 All the parameters to be mentioned in Performance data Noted & Updated
6 A2 Mark the impeller type Noted & Updated
7 A2 Mark wear rings Noted & Updated
8 A2 Mark casing type Noted & Updated
9 A2 Mark type of oil heater Noted & Updated
10 A2 Mention all the data in Construction Noted & Updated
11 A2 mention the rating of coupling Noted & Updated
12 A2 Mention the material class Noted & Updated
As per API-610 Class S-6, Casing Material
13 A2 Shall be A 487 Gr CA6NM
is A216 Gr. WCC.
14 A2 Mark the requirements of instrumentation provided for pump Noted & Updated
15 A2 Mention the parameters of weight & dimension Noted & Updated
16 A2 Hydrotest is required Noted & Updated
17 A2 Correct the sequence Noted & Updated
18 A2 rated rpm given in the datasheet is 2925rpm;Check and confirm Noted & Updated
Indicate the operating ranges (rated, allowable and
19 A2 preferred),BEP,Suction specific speed,specific speed,shutoff Noted & Updated
head,Power at the end of the curve

Note: Document status will be " Closed" after receipt of client comments.
VEDANTA LIMITED

Cairn Oil & Gas

Provision of PC Work for IW Tank Modification Project.

Document Name:Pump Datasheet & Perforamnce Curve for Skimmed


Oil Pump

Doc No:-M283SMK1M42-MPT-M-DS-1001

Yashwini Meena
26/03/2024 1

A3 18-03-2024 Issued for Client Review Vijay Hani Arun

A2 19-02-2024 Issued for Client Review Vijay Hani Arun

A1 19-02-2024 Issued for Internal Review Vijay Hani Arun

Rev Date Purpose of Issue Prepared By Checked By Approved By


Manufacturer MECHANICAL DATA SHEET FOR PAGE No.: 1
CENTRIFUGAL PUMPS

Customer & Client


(P-121 E/F/G) PROJECT No.: 221000430

REVISION MARK
TITLE: Pump Datasheet & Performance
Curve for Skimmed Oil pump SHT. 1 OF 4 REV. A3

DOC.No. : M283SMK1M42-MPT-M-DS-1001 EQPT. No. : P-121 E/F/G QTY.: 3


RFQ / MR No. :
PROJECT : INJECTION WATER TANK MODIFICATION (D-411C)
1 APPLICABLE TO ENQUIRY PURCHASE AS BUILT
2 SITE : MPT, BARMER,RAJASTHAN,INDIA UNIT : MPT
3 QTY REQUIRED : 3 NORMAL: 2 STANDBY : 1 SPARE : -
4 MANUFACTURER : RUHRPUMPEN INDIA PVT LTD MODEL : SCE 3x1.5x11 (A)
5 PUMP SERIAL NO.: 221000430-01,02,03 TYPE : Centrifugal (OH2) (AS PER API 610) A2

6 GENERAL
7 PUMP DRIVEN BY : ELECTRIC MOTOR TURBINE DIESEL ENGINE
8 OPERATION : INDIVIDUAL SERIES PARALLEL
9 DUTY : CONTINUOUS INTERMITTENT
10 CODES / STDs :`
11 GEAR ITEM NO : - GEAR DATA SHEET NO. : -
12 DRIVER ITEM NO : - DRIVER DATA SHEET NO. : -

13 OPERATING DATA
14 LIQUID PUMPED : SKIMMED FLUID (OIL + WATER) CAPACITY: NORMAL- - RATED- 23.71 m³/h
15 DENSITY : 947 kg/m³ MIN. - MAX.- m³/h
16 SPECIFIC HEAT : 2.74 kj/kg°C PUMPING TEMP. : NOR.- 67 MAX.- 70 MIN.- 55 °C
17 VAP. PRESSURE : 0.25 kg/cm2 67 Deg. C SUCTION PR. : MAX.- 0.29 RATED- 0 kg/cm2g
18 VISCOSITY : 3.595 cP @ 67 Deg. C DISCHARGE PRESSURE : 6.8 kg/cm2g
19 SOLID CONTENT : mg/l DIFFERENTIAL PRESSURE : 6.84 kg/cm2
20 CHLORIDE CONC. : PPM DIFFERENTIAL HEAD : 72 m
21 H2S CONC. : <100 PPM NPSH AVAILABLE : 4.5 m
22
CORROSIVE EROSIVE FLAMMABLE TOXIC
23 PERFORMANCE DATA
24 PROPOSAL CURVE NUMBER : OKH 115 010.00 IMP. DIA: MIN.- 208 RATED- 245 MAX.- 268 mm A1
25 NUMBER OF STAGES : 1 PUMP SPEED (RATED) : 2925 rpm
26 EFFICIENCY OF PUMP : 47.3 % NPSH REQUIRED : 1.35 m A2
27 MIN. CONT. THERMAL FLOW : N/A m³/h POWER AT RATED CONDITIONS : 9.30 kW A2
28 MIN. CONT. STABLE FLOW : 5.71 m³/h MAX. POWER OF RATED IMPELLER : 10.93 m A2
29 SHUT - OFF HEAD : 83.62 meters PREF. OPERATING REGION : 18.46 TO 31.65 m³/h A2
30 DESIGN TEMPERATURE : 67 °C CAPACITY (WATER) : 23.71 m³/h A2
31 M.A.W.P : 4000 kPa g @ 67 °C HEAD (WATER) : 72 m A2
32 HYDROTEST PRESSURE : 6000 kPa g EFFICIENCY (WATER) : - %
33 SUC. SPECIFIC SPEED : 486 (SI UNIT) POWER (WATER) : - kW

34 CONSTRUCTION
35 CASING TYPE - SINGLE VOLUTE DOUBLE VOLUTE DIFFUSER BOWL
36 CASING MOUNTING - FOOT MOUNTED CENTRE LINE SEP.MOUNT.PLAT VERTICAL
37 IMPELLER TYPE - CLOSED SEMI OPEN OPEN A2
38 WEARING RINGS - IMPELLER FRONT IMPELLER BACK CASING FRONT CASING BACK A2
39 GLAND FOR PACKING - SINGLE SPLIT WATER SMOTHERING SPLIT
40 TRANSMISSION - DIRECT / COUPLING GEAR BOX V-BELT
41 BASE PLATE TYPE - DRAIN RIM PLATE COMMON PLATE COMMON SKID SOLE PLATE
42 BEARING LUBRICATION - GREASE OIL RING OIL
43 IMPELLER MOUNTING - OVERHUNG BETWEEN BEARINGS
44 CASING SPLIT - AXIAL RADIAL A2
45 IMPELLER FIXING TO SHAFT - KEYED THREADED
46 OIL HEATER - ELECTRIC STEAM NOT APPLICABLE A2
47 ROT.VIEW FROM COUPLING - CLOCKWISE ANTI-CLOCKWISE
48 COLUMN PIPE - FLANGED THREADED NOT APPLICABLE
49 LINE SHAFT - OPEN ENCLOSED NOT APPLICABLE
50 AUX. THRUST BALANCED BY - BALANCE HOLES BALANCING PISTON
51 RADIAL BEARING - MAKE / TYPE / No. : SKF / BALL / 6211C3
52 AXIAL BEARING - MAKE / TYPE / No. : SKF / BALL / 7310BECBM

A2 04-03-2024 Issued for approval VY VS KR

A1 29-02-2024 Issued for Review VY VS KR


REV. DATE REVISION DESCRIPTION PREPD. CHKD. APPD.

Sensitivity: Internal (C3)


#
PAGE 2 OF 6
Manufacturer MECHANICAL DATA SHEET FOR PAGE No.: 2
CENTRIFUGAL PUMPS
(P-121 E/F/G) PROJECT No.: 221000430
Client & Customer TITLE: Pump Datasheet & Performance

REVISION MARK
Curve for Skimmed Oil Pump
SHT. 2 OF 4 REV. A3
DOC.No. : M283SMK1M42-MPT-M-DS EQPT. No. : P-121 E/F/G QTY.: 3
PROJECT : INJECTION WATER TANK MODIFICATION (D-411C)
RFQ / MR No.
1 CONSTRUCTION ( CONTD.)
2 COUPLING DETAILS LUB OIL GRADE : SAE No. : N/A
3 TYPE : Flexible disc spacer QUANTITY : - ltrs
4 MAKE : RATHI GD² VALUE - FOR PUMP : 0.226 kgm² A2
5 MODEL : REM-8 GD² VALUE - FOR DRIVER : 0.13 kgm² A2
6 COUPLING RATING : 1kW kW/100rpm MIN. RUNNING CLEARANCE : FRONT : - mm A2
7 SERVICE FACTOR : 1.5 Minimum (IMPELLER & CASING) BACK : - mm
8 SPACER LENGTH : 180 mm SHAFT DIA : AT COUPLING : 34.93 mm A1
9 LIMITING SPEED : 2925 rpm AT BEARING : - mm A1
10 LUBRICATION : Non Lubricated AT SLEEVE : - mm
11 BALANCING AS PER : ISO 21940-11 Gr 2.5 SPAN BETWEEN BEARING CENTRES : - mm
12 SPAN B/W BEARING AND IMPELLER : N/A mm

13 MATERIAL OF CONSTRUCTION
14 API-610, MAT. CLASS (APPENDIX -H) : S-6 WEAR RING (CASING / IMP) : A 276 Type 420
15 CASING : A 216 Gr. WCC WETTED FASTENERS : N/A
16 IMPELLER : A 487 Gr. CA6NM Class A CASING/GLAND STUD.NUT : Carbon Stee
17 SHAFT : A 479 Type 410 Cl 2 COUPLING : Stainless steel
18 SLEEVE : N/A COUPLING GUARD : N/A
19 DIFFUSER : N/A BASE PLATE : Carbon steel
20 GASKET : AISI 316 SOLE PLATE : N/A
21 COLUMN : N/A FOUNDATION BOLTS/NUTS : -
22 BUSH : B 584 - UNS C89836 FLUSH. PIPING, VALVE, FLANGE : N/A
23 GLAND : N/A DRAIN PIPING, VALVE, FLANGE : Special material
24 THROAT BUSH : A 276 Type 420 COOL. PIPING, VALVE, FLANGE : N/A
25 THROTTLE BUSH : N/A CONVERSION KIT : -

26 MAIN CONNECTIONS(ANSI B 16.5)


27 DESCRIPTION SIZE RATING FACING POSITION
28 PUMP SUCTION NOZZLE : 3 inch 300 Class RF END
29 PUMP DISCHARGE NOZZLE : 1.5 inch 300 Class RF TOP

30 OTHER CONNECTIONS
31 DESCRIPTION QTY. SIZE (NPS) TYPE FACING
32 PUMP CASING DRAIN : 1 ½ inch SW RF
33 PUMP CASING VENT : N/A N/A N/A N/A
34 PRESSURE GAUGE : N/A N/A N/A N/A
35 TEMPERATURE GAUGE : N/A N/A N/A N/A
36 BASE PLATE DRAIN : 1 2-inch NPT -
37 LANTERN RING IN/OUT : N/A N/A N/A N/A
38 GLAND QUENCH IN/OUT : N/A N/A N/A N/A
39 NOTE: CASING DRAIN SHALL BE WITH PIPE VALVE & FLANGE TERMINATED AT BASE PLATE EDGE.

40 SHAFT SEALING
41 SHAFT SEAL TYPE : PACKING MECHANICAL SEAL
42 MECHANICAL SEAL FIXING : AT SHOP AT SITE
43 CONVERSION KIT : REQUIRED NOT REQUIRED

44 MECHANICAL SEAL
45 MANUFACTURER : Eagle Burgmann MATERIAL OF CONSTRUCTION
46 MODEL : A21348AC STATIC FACE : SIC A2
47 TYPE : LL9DKUU ROTARY FACE : CARBON A2
48 SIZE : 0060 O - RINGS : PERFLUOROELASTOMER
49 MFR'S CODE : KXWKC ROT. ASSEMBLY : CARBON + SS 16 A2
50 API CODE : API 682 - 23A-LIN-050-53B/61 GASKETS : N/A
51 CONSTRUCTION : CARTRIDGE NON - CARTRIDGE

52 PACKING
53 MANUFACTURER : N/A NO OF RINGS : N/A
54 SIZE : N/A PACKING COOLING - FLOW : N/A m3/hr
55 MOC OF RINGS : N/A PRESSURE : N/A kg/cm2g

#Sensitivity: Internal (C3) PAGE 3 OF 6


Manufacturer MECHANICAL DATA SHEET FOR CENTRIFUGAL PUMPS PAGE No.: 3
(P-121 E/F/G)
TITLE: Pump Datasheet & Performance Curve for PROJECT No.: 221000430
Client & Customer

REVISION MARK
Skimmed Oil Pump
SHT 3 OF 4 REV. A3
DOC.No. : M283SMK1M42-MPT-M-DS-1001 EQPT. No. : P-121 E/F/G QTY.: 3
PROJECT INJECTION WATER TANK MODIFICATION (D-411C)
RFQ / MR No.
1 AUXILIARY PIPING FOR MECHANICAL SEALING
2 TEMP INLET PR. QUANTITY CONNECTION
SERVICE API PLAN FLUID
3 0 (kPa g) (LTRS/HR) SIZE TYPE
( C)
4 FLUSHING (F) : - - - - - - -
5 BARRIER (B) : - - - - - - -
6 DRAIN (D) : - - - - - - -
7 VENT ( V) : - - - - - - -
8 COOLING(C) : - - - - - - -
9 QUENCHING (Q) : - - - - - - -
10 HEATING(H) : - - - - - - -
11 NOTE : THE OPTIONALS MENTIONED IN API PLANS ARE IN VENDOR'S SCOPE OF SUPPLY

12 DRIVER
13 ELECTRIC MOTOR DIESEL ENGINE / TURBINE
14 SUPPLIED BY : CGL SUPPLIED BY : N/A
15 MOUNTED BY : RUHRPUMPEN MOUNTED BY : N/A
16 MANUFACTURER : CGL MANUFACTURER : N/A
17 ENCLOSURE : Flame Proof Enclosure Zone I MODEL NO. : N/A
18 IP CLASS FOR PROTECTION : IP55 TYPE : N/A
19 RATED OUTPUT : 11 kW ISO RATED kW : N/A kW
20 SPEED (SYN) : 2925 rpm kW AT SITE : N/A kW
21 SERVICE FACTOR : POWER FACTOR : 0.90 RATED SPEED : N/A rpm
22 STARTING METHOD : SOFT START DOL EFFICIENCY : N/A %

23 SITE DATA
24 ELEVATION ABOVE MSL : meters
25 ATM. PRESSURE : Barometer 1.002 kg/cm2 a
26 RANGE OF AMB. TEMPERATURE : 0 0
MIN. 2 C, MAX. 50 C
27 RELATIVE HUMIDITY : MIN. 23 %, MAX. 74 %
28 HAZ. AREA CLASSIFICATION : ZONE 2 , DIVISION , GAS GROUP IIA/IIB , TEMP CLASS T3
29 UNUSUAL CONDITION : DUST FUMES MARINE CONDITIONS

30 UTILITIES
415 (+/- 50 (+ /-
ELECTRIC SUPPLY DRIVER - VOLTS, Hz, 3 PHASE ( Note-11 )
31 10%) 5%)

32 (REFER ELECTRIC : CONTROLS - - VOLTS, - Hz, - PHASE


33 MOTOR DATA SHEET) HEATERS - - VOLTS, - Hz, - PHASE
34 COOLING WATER :
35 QUANTITY - - SUPPLY PR.- - SUPPLY TEMP - - 0
m3/h kg/cm2 a, C (MAX)
36 * (MAX) RETURN PR.- * RETURN TEMP. - * 0
TEMP RISE (∆T) - kg/cm2 a, C (MAX)
37
38 STEAM : PRESSURE - - kg/cm2 a, NITROGEN : PRESSURE - - kg/cm2 a
39 TEMPERATURE - - 0 TEMPERATURE - - 0
C C
40
41 INSTRUMENT AIR : PRESSURE - - kg/cm2 a, UTILITY AIR : PRESSURE - - kg/cm2 a
42 TEMPERATURE - - 0 TEMPERATURE - - 0
C C

43 INSTRUMENTATION
44 FOR CAPACITY : FOR TEMPERATURE :
45
ORIFICE PLATE TEMPERATURE GAUGE
46
FLOWMETER THERMOWELL
47 FOR VIBRATION : FOR PRESSURE :
48
NON-CONTACTING PRESSURE GAUGE
49
ACCELEROMETER DIGITAL TRANSMITTER
50 NOISE & VIBRATION
51 NOISE LEVEL : < 85 dBA @ 1 METER FROM SKID EDGE
52 VIBRATION LEVEL (GUARANTEED) : * pk-pk filtered

53 PAINTING & PACKING


55 PAINTING : AS PER ATTACHED SPECIFICATION PACKING : DOMESTIC
55 MANUFACTURER'S STANDARD EXPORT
56 STORAGE MORE THAN 6 MONTHS

PAGE 4 OF 6
Sensitivity: Internal (C3)
#
Manufacturer 4

N MARK
REVISIO
MECHANICAL DATA SHEET FOR PAGE No.
CENTRIFUGAL PUMPS (P-121 E/F/G PROJECT No.: 221000430
Client & Customer
TITLE: Pump Datasheet & Performance
Curve for Skimmed Oil Pump SH 4 OF 4 REV. A3
DOC.No. : M283SMK1M42-MPT-M-DS-1001 EQPT. No. : P-121 E/F/G QTY.: 3
PROJECT : INJECTION WATER TANK MODIFICATION (D-411C) RFQ / MR No. :
1 WEIGHTS & DIMENSIONS DETAIL
2 PUMP : 117 kg , DRIVER : 188 kg , BASE PLATE (SKID) : 405 kg
3 COUPLING : 2.395 kg , GEARBOX : N/A kg , TOTAL WEIGHT : 766 kg
4
5 OVERALL DIMENSION : (L X B X H) 1800 mm 1500 mm 2696 mm 00
6 QA INSPECTION AND TESTS FOR EACH PUMP
7 DESCRIPTION
8 1. QA / QC PLAN REQUIRED
9 2. MATERIAL CERTIFICATES REQUIRED
10 3. HYDROSTATIC TEST REQUIRED WITNESS
11 4. PERFORMANCE TEST REQUIRED WITNESS
12 5. NPSH TEST (IF REQUIRED) REQUIRED WITNESS
13 6. COMPLETE UNIT TEST (STRING TEST) REQUIRED WITNESS
14 7. AUXILIARY EQUIPMENT TEST REQUIRED WITNESS
15 8. DISMANTLE & INSPECTION AFTER TEST REQUIRED WITNESS
16 9. DIMENSIONS & CLEANLINESS PRIOR TO REQUIRED WITNESS
17 FINAL ASSEMBLY
18 10. ASSEMBLY OF PUMPS WITH JOB DRIVERS REQUIRED WITNESS
19 ON BASE PLATE BEFORE DESPATCH

20 VENDOR'S SCOPE OF SUPPLY / SCOPE OF WORK


21 PUMP DRIP TRAY
22 DRIVER SUCTION STRAINER
23 COUPLING / COUPLING GUARD (360 deg. protection) MECHANICAL SEALS & FLUSHING PIPE ASSEMBLY
24 BASE PLATE (COMMON FOR PUMP & DRIVER) COMPANION FLNG FOR SUC & DISC (IF REQD AS PER SPEC)
25 DRIVER FIXING BOLTS ON BASE PLATE ORIFICE PLATE FOR BY PASS ARRANGEMENT WITH "R0"
26 ACCESSORIES / AUXILIARIES (AS APPLICABLE) ARC VALVE
27 FOUNDATION /ANCHORING BOLTS VIBRATION SWITCH FOR PUMP & MOTOR SHAFT
28 INSTRUMENTATION & PIPING WITHIN SKID COMMISSIONING SPARES
29 OPERATIONAL SPARES SPECIAL TOOLS &
TACKLES
30 CONSUMABLES (CHEMICALS, LUBE OIL ETC) PAINTING
31 INSPECTION AND TESTING PACKING & FORWARDING
32 DRAWING AND DOCUMENTS TRANSPORT
33 INSTALLATION INSTALLATION
SUPERVISION
34
35 NOTES :
36 1. Cooling water is Not applicable, Air cooling only Appicable.
37 2. The MOC of pump parts shall be selected to withstand H2S Concentration <100 ppm.
38 All pump materials selected shall be suitable for service intended & process fluid characteristics.
39 3. Pump shall be double mechanical seal. Seal type and seal flush plan shall be confirmed by pump vendor based on the
40 operating and pumping fluid parameter.
41 4. All pump accessories shall be supplied by pump manufacturer.
42 5. Casing drain / Vent / flushing provision to be provided to drain & vent the pump by pump manufacturer.
43 6. Pump shall be designed & supplied as per API guidelines.
44 7. All * marked data shall be furnished by manufacturer.
45 8. Vendor shall furnish all the documents,drawings for the pump.
46 9. Pump characteristic curves,motor torque speed curves shall be submitted by vendor.
47 10. The normal flow specified in data sheet is without MCSF. Vendor to specify MCSF value for pump & same shall be added
48 for rated capacity. Rated flow shall be within the region of 50% to 110% of BEP.
49 11. Calculated Hydraulic power is 3.35 KW. Vendor to furnish motor required power based on pump & motor efficiencies.
50 Motor shall be designed for hazardous area classification mentioned in site data.
51 12. Manufacturer to provide pump suction & discharge flanges alongwith suction reducer & discharge expander.
52 Suction line size is 150 NB & Discharge line size is 100 NB.
53 13. Pump shall have a continuously rising, stable head / capacity performance curves.
54 14. Pumps shall be capable of at least a 10 % head/capacity increase at rated conditions by installing a new impeller,
55 additional stage, or different hydraulic design. Impellers shall not be larger than 95% of maximum impeller size for that
56 15. Pump, motor and seal flushing system components shall be mounted on the same skid.
57 16. Pump casing shall be designed for pump shut-off pressure.
58 17. Pumps where difference between NPSHA and NPSHR from quoted minimum flow to rated flow is less than
59 1m are not acceptable.
60 18. Vendor to Supply the companion flange along with stud bolts,nuts & gaskets If body flange (Suction & Discharge)
61 which does not comply with ASME B16.5.
62 19. Refer ' Specification for API 610 Centrifugal Pump , Doc. No.CAIRN-TSG-M-SP-0007
63 20. Motor driver shall be selected for end of curve operation or 15 % higher than rated BkW whichever is higher.
64 Refer "Specification for medium Voltage Motor'', Doc. No. CAIRN-TSG-E-SP-0002,.
PAGE 6 OF 6
Global Proposal System 23.4.1

Pump Performance Curve


Performance based on test acceptance - API
Power - kW 16

12
Power
8

150 Allowable Operating Region : 5.71 to 31.65 m3/h 100


MCSF

135 90

120 80

268 mm
105 70

Efficiency - %
90 60
Head - m

75 245 mm 50
Efficiency
60 40

208 mm
45 30

30 Preferred Operating Region : 18.46 to 31.65 m3/h 20

15 10

0 0

3.0
NPSHr - m

NPSHr

1.5

0.0
0 5 10 15 20 25 30 35 40 45
Flow - m3/h
Customer : S. Mark Size : SCE 3x1.5x11 (A) (OH2) Flow, rated : 23.71 m3/h
Customer reference : Stages :1 Differential head / pressure, rated : 72.00 m
Item number : P-121 E/F/G Speed, rated : 2925 rpm Fluid density, rated / max : 0.947 / 0.947 SG
Service : INJECTION WATER TANK Based on curve number : OKH 115 010.00 Viscosity : 3.60 cP
MODIFICATION (D-411C) Efficiency : 47.3 % Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 0.96 / 1.00
Quantity :3 Power, rated : 9.30 kW
Quote number : 2074822 NPSH required : 1.35 m
Date last saved : 01/11/2024 5:49 AM
Preferred Operating Region : 18.46 to 31.65 m3/h BEP flow, rated : 26.38 m3/h Power at the end of the curve : 10.97 kW
Allowable Operating Region : 5.71 to 31.65 m3/h Shut off head : 83.62 m

Specific Speed : 486 US Units Suction specific speed : 9,164 US Units