HTCables
HTCables
CONTENTS
APPLICATION SPECIFICATIONS
For internal wiring of electronic and • In accordance with DEF 61-12 Part 18
5 other equipment. Incorporates LFH • Conductors: Solid or stranded tinned
(Limited Fire Hazard) insulation for copper conductors to BS 2G 231.
reduced levels of smoke and toxic • Insulation: Thin-wall LFH insulation to
fumes in the event of a fire. DEF 61-12 Part 18 for Category 1
equipment wire displaying following
characteristics:
Oxygen index: 30% min.
Temperature index: 2500C min
HCL emission @ 8000C: 0.5% max
Toxicity index: ≤ 0.2
• Flame retardant to BS 3G 230
• Temp Rating: 1200C max. conductor
operating temperature.
• Voltage Rating: 600V a.c./800V d.c.
5:2 ®
HIGH TEMPERATURE CABLES
N.S.N. Anixter Colour Cond. Nom. Nom. Thickness Min. Max. Approx.
6145-99-891- Part No. Size Cond. Cond. of O/D O/D Cable
A10DW-891- AWG Area Stranding Insulation Weight
mm2 #/mm mm mm mm kgs/km
® 5:3
HIGH TEMPERATURE CABLES
N.S.N. Anixter Colour Cond. Nom. Nom. Thickness Min. Max. Approx.
6145-99-891- Part No. Size Cond. Cond. of O/D O/D Cable
A10DW-891- AWG Area Stranding Insulation Weight
mm2 #/mm mm mm mm kgs/km
5:4 ®
HIGH TEMPERATURE CABLES
N.S.N. Anixter Colour Cond. Nom. Nom. Thickness Min. Max. Approx.
6145-99-891- Part No. Size Cond. Cond. of O/D O/D Cable
A10DW-891- AWG Area Stranding Insulation Weight
mm2 #/mm mm mm mm kgs/km
® 5:5
HIGH TEMPERATURE CABLES
N.S.N. Anixter Colour Cond. Nom. Nom. Thickness Min. Max. Approx.
6145-99-891- Part No. Size Cond. Cond. of O/D O/D Cable
A10DW-891- AWG Area Stranding Insulation Weight
mm2 #/mm mm mm mm kgs/km
5:6 ®
HIGH TEMPERATURE CABLES
N.S.N. Anixter Colour Cond. Nom. Nom. Thickness Min. Max. Approx.
6145-99-891- Part No. Size Cond. Cond. of O/D O/D Cable
A10DW-891- AWG Area Stranding Insulation Weight
mm2 #/mm mm mm mm kgs/km
NB: Wire braid screened versions with or without sheath also available. Details available
upon request.
Minimum bend radius Flexing Applications 10D
Fixed Applications 4D
Where D = overall diameter of cable.
For further technical information see page 5:8
® 5:7
HIGH TEMPERATURE CABLES
Technical Information
DEF 61-12 Part 18 Type 1 “LFH” Equipment Wires
5 19
30
1/0.90
7/0.10
28.5
336.0
39.7
468.0
4.0
0.3
28 7/0.12 259.0 360.8 0.5
26 19/0.10 141.5 197.1 0.8
24 19/0.12 95.6 133.1 1.3
22 19/0.15 60.0 83.6 2.2
20 19/0.20 33.2 46.2 3.7
18 19/0.25 21.1 29.4 5.8
16 19/0.30 14.5 20.2 7.7
14 37/0.25 10.9 15.2 11.4
12 37/0.30 7.6 10.6 15.6
NB: Current ratings quoted assume single isolated cable in FREE AIR,
ambient air temperature of 1050C and conductor operating temperature of
1200C.
For ambient air temperatures other than 1050C, the following rating factors
should be applied:
Ambient air temp 0C 60 65 70 75 80 85 90 95 100
Rating factor 2.0 1.91 1.83 1.73 1.63 1.53 1.41 1.29 1.15
Where cables are to be grouped, the following rating factors apply:
No. of cables grouped
and touching 2 3 4 5 10 15 20 25
Rating factor 0.80 0.70 0.65 0.60 0.45 0.40 0.36 0.33
5:8 ®
HIGH TEMPERATURE CABLES
® 5:9
HIGH TEMPERATURE CABLES
APPLICATION SPECIFICATIONS
For use in areas where thermal, elec- • In accordance with BS3G210
5:10 ®
HIGH TEMPERATURE CABLES
® 5:11
HIGH TEMPERATURE CABLES
APPLICATION SPECIFICATIONS
For use in areas where thermal, • In accordance with BSG222.
5 electrical or environmental conditions • Can also be supplied to
are very demanding. MIL-W-22759.
• Avionics and general electronics • Conductors: Nickel plated copper
• Gas turbines wire conductors.
• Specialised Hi-Fi systems • Constructed with a combination of
PTFE tapes and a PTFE impregnated
glass yarn braid for extra strength
• Temp Rating: 2600C max. conductor
operating temperature.
• Voltage Rating: 600V
• Frequency max: 1600HZ
5:12 ®
HIGH TEMPERATURE CABLES
® 5:13
HIGH TEMPERATURE CABLES
APPLICATION SPECIFICATIONS
5 For use on internal wiring of equipment • Manufactured in accordance to DEF
where exposed to high temperatures. Stan 61-12 Part 29 Type 5.
• Conductors: Tinned copper wire
conductors.
• Insulation: ETFE insulation
• Temp Rating: 1350C max. conductor
operating temperature.
• Voltage Rating: 250V
• Other constructions available
including screened and sheathed
versions, with Tinned or Silver coated
conductors.
5:14 ®
HIGH TEMPERATURE CABLES
5
** Please use the following suffix for required insulation colour.
01 White
02 Black
03 Red
06 Blue
12 Pink
Other colours available to order
® 5:15
HIGH TEMPERATURE CABLES
APPLICATION SPECIFICATIONS
For use in situations in plant and • Conductors: Nickel plated copper
5 process control where power supplies conductors.
to equipment are at risk from high • Insulation: PTFE Primary insulation
temperatures. • Glass/Mica tape Secondary insulation.
• Steelworks and foundaries • Overall Glass braid with heat and
• Glass and ceramic industries abrasion resistant finish.
• Boiler makers • Single core colour natural.
Multicore: individual cores can be
colour coded on request.
• Temp Rating: 2500C max. conductor
operating temperature.
• Voltage Rating: 600/1000V
5:16 ®
HIGH TEMPERATURE CABLES
NB. Current ratings quoted assume single isolated cable in FREE AIR, ambient air
temperature of 800C and conductor operating temperature of 2500C.
For ambient air temperatures other than 800C, the following rating factors should be
applied:
Ambient air temp 0C 100 120 140 160 180 200 220 240
Rating factor 0.94 0.87 0.80 0.73 0.64 0.54 0.42 0.24
No of cables grouped
and touching 2 3 4 5 10 15 20 25
Rating factor 0.80 0.70 0.65 0.60 0.45 0.40 0.36 0.33
® 5:17
HIGH TEMPERATURE CABLES
5 APPLICATION SPECIFICATIONS
Silicone cables are recommended for • In accordance with BS6500 and
installations where for short periods of BS6007.
time, the temperature can fluctuate • CENELEC code H05SJ-K single core.
from high to low. This would cause • Conductors: Flexible Class 5 tinned
standard cables to become inflexible copper conductors to BS6360
and brittle. • Insulation: Silicone rubber insulation
• Steel mills Type EI 2 to BS7655.
• Ceramic and glass factories • Treated glass fibre braid.
• High temperature applications • Temp Rating: 1800C max. conductor
operating temperature.
• Voltage Rating: 300/500V
5:18 ®
HIGH TEMPERATURE CABLES
For current ratings refer to Section 2, Flexible Cables & Cords page 2:48
® 5:19
HIGH TEMPERATURE CABLES
APPLICATION SPECIFICATIONS
5 Silicone cables are recommended for • In accordance with VDE 0250.
installations where for short periods of • Conductors: Tinned copper
time the temperature can fluctuate conductors.
from high to low. This would cause • Insulation: Silicone rubber insulation
standard type cables to become • Temp Range: -600C to +1800C max.
inflexible and brittle. conductor operating temperature.
• Steel mills • Voltage Rating: 300/500V
• Consumer white goods
• Ceramic and glass factories
• High temperature applications
5:20 ®
HIGH TEMPERATURE CABLES
® 5:21
HIGH TEMPERATURE CABLES
APPLICATION SPECIFICATIONS
5 Silicone cables are recommended for • In accordance with VDE 0250.
installations where for short periods of • Conductors: Tinned copper
time the temperature can fluctuate conductors.
from high to low. This would cause • Insulation: Silicone rubber insulation
standard type cables to become • Core Identification:
inflexible and brittle. 2 core - blue, brown
• Steel mills 3 core - green/yellow, blue, brown
• Consumer white goods 4 core - green/yellow, black, blue,
• Ceramic and glass factories brown
• High temperature applications • Red overall Silicone rubber jacket.
• Additional glass fibre braid and lacquer
(SIHSIGL types only).
• Temp Range: -600C to +1800C max.
conductor operating temperature.
• Voltage Rating: 300/500V
5:22 ®
HIGH TEMPERATURE CABLES
® 5:23
HIGH TEMPERATURE CABLES
5:24 ®