Bartec Push Button Station

The document details ComEx control stations designed for explosion protection in Zones 21 and 22, featuring customizable enclosures and various control options. It includes technical specifications such as certification, connection types, and permissible ambient temperatures. Additionally, it provides a selection chart for different control units and their corresponding order numbers and weights.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views4 pages

Bartec Push Button Station

The document details ComEx control stations designed for explosion protection in Zones 21 and 22, featuring customizable enclosures and various control options. It includes technical specifications such as certification, connection types, and permissible ambient temperatures. Additionally, it provides a selection chart for different control units and their corresponding order numbers and weights.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

ComEx Control stations also for Zone 21 and 22

ComEx control stations

Features Explosion protection Technical data


æ 3 standard enclosures Ex protection type Connection
æ Easy to install II 2G Ex ed IIC T6 Terminals 2.5 mm2
II 2D Ex tD A21 IP 67 T 80 °C
æ Extremely flexible PE conductor terminals
Class I, Zone 1 AEx ed IIC, Ex ed IIC 4 x 2.5 mm2
æ Customer-tailored solutions Class I, Division 2 Groups A, B, C, D
Rated insulation voltage
Ex ed IIC, T6
max. AC 690 V
Certification
Description Nominal current
PTB 00 ATEX 1068
max. 16 A
ComEx is a flexible system offering standard as UL E184198
well as customer-specific local control and IECEx PTB 08.0022 Cable entry
indicating units. INMETRO 2004 EC 02 CP003 M 20 x 1.5 for cable ∅ 6 to 13 mm
M 25 x 1.5 for cable ∅ 7 to 12 mm
You have the choice between three standard Permissible ambient temperature
M 25 x 1.5 for cable ∅ 13 to 21 mm
enclosures which can accomodate up to three dif- -55 °C to +60 °C
ferent control and indicating devices. (-20 °C to +60 °C for Zone 21 and 22) Enclosure
Combinations of up to three ComEx enclosures Thermoplastic
are possible. Protection class
Either stuffing box glands in M20 x 1.5 and IP 66/IP 67
M25 x 1.5 made of plastic or cable glands made
of metal are available for the electrical connection.
The plastic glands require no lock nuts.
Metal glands are screwed into a metal earth plate
sheet inside of the enclosure. Maximum amount
of cable clands: two off M20.
To ensure easier operation on site, each enclosure
can be equipped with an individual info-label.
For offshore applications special oil-resistant
03-0330-0189/A-07/10-BCS-200863/1

attachments are available.

32

200863_1_2.pmd 2 12.11.2010, 10:13


Dimensions fully pre-assembled units also for Zone 21 and Zone 22

Control unit, single Type 07-3511-.... Control station, double Type 07-3512-....

1
81
88,5 8
81
88,5 8

∅ 5,5
∅ 5,5

2
88

50

130

93
∅ 5,5
3

∅ 5,5
3
73
3
73

Control station, triple Type 07-3513-.... 4

81
88,5
8

5
∅ 5,5
176

136

6
∅ 5,5
3

73
7

91
88,5
8
∅ 5,5

136
176

∅ 5,5
3

73
03-0330-0189/A-07/10-BCS-200863/2

33

200863_1_2.pmd 3 12.11.2010, 10:13


Control stations ComEx Standard

Selection chart

Wiring diagram Description Weight Order no.

1 pushbutton 0.33 kg 07-3511-10P74


1 NO + 1 NC
incl. labels red, green, yellow, white

1 NOT/AUS Emergency Stop 0.36 kg 07-3511-10N84


1 NO + 1 NC
marked NOT/AUS and Emergency-Stop

1 Mushroom Keyswitch 0.40 kg 07-3511-10K34


1 NO + 1 NC
with key to reset

1 Selector switch 0.35 kg 07-3511-10S94


1 NO + 1 NC, 2 position with 2 stops
0 and I, latching

1 Selector switch 0.35 kg 07-3511-10S04


1 NO + 1 NC, 3 position with 3 stops
I - 0 - II, latching

1 Selector switch 0.35 kg 07-3511-10S14


1 NO + 1 NC, 3 position with 3 stops
I - 0 - II, momentary-contact

1 Lamp 0.35 kg
red 07-3511-10LRR
green 07-3511-10LGG
yellow 07-3511-10LYY
white 07-3511-10LWW

1 Mushroom Pushbutton, black 0.35 kg 07-3511-10P84


1 NO + 1 NC

1 Keyswitch 0.40 kg 07-3511-10K04


1 NO + 1 NC
lockable in both positions

1 Keyswitch 0.40 kg 07-3511-10K14


1 NO + 1 NC
03-0330-0189-08/08-BCS-200863/3

lockable in the pushed-in-position

1 Keyswitch 0.40 kg 07-3511-10K24


1 NO + 1 NC
lockable in the initial position

30

200863_3_4.pmd 2 12.11.2010, 10:11


Control stations ComEx Standard

Selection chart
1
Wiring diagram Description Weight Order no.

2 pushbuttons 0.50 kg 07-3512-10P74P74


1 NO + 1 NC each
including key labels 2

3
1 indicator lamp, 1 pushbutton 0.52 kg
with indicated lamp red 07-3512-10LRRP74
green 07-3512-10LGGP74
yellow 07-3512-10LYYP74
white 07-3512-10LWWP74
blue 07-3512-10LBBP74 4
1 NO + 1 NC

1 indicator lamp, 2 pushbuttons 0.70 kg


with indicated lamp red 07-3513-10LRRP74P74 5
green 07-3513-10LGGP74P74
yellow 07-3513-10LYYP74P74
white 07-3513-10LWWP74P74
1 NO + 1 NC each

3 pushbuttons 0.68 kg 07-3513-10P74P74P74 7


1 NO + 1 NC each
including key labels

2 pushbuttons 0.70 kg 07-3513-10P74P74N84


1 emergency stop button
1 NO + 1 NC each
03-0330-0189-08/08-BCS-200863/4

31

200863_3_4.pmd 3 12.11.2010, 10:11

You might also like