0% found this document useful (0 votes)
9 views4 pages

VIENTO RE

The document provides detailed calculations for wind loads on the VIENTO project, including wind pressure, gust effects, and wind forces in both X and Y directions. It specifies parameters such as basic wind speed, importance factors, exposure categories, and wall pressure coefficients. Additionally, it includes results for base shear, overturning moments, and stabilizing moments for the structure.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views4 pages

VIENTO RE

The document provides detailed calculations for wind loads on the VIENTO project, including wind pressure, gust effects, and wind forces in both X and Y directions. It specifies parameters such as basic wind speed, importance factors, exposure categories, and wall pressure coefficients. Additionally, it includes results for base shear, overturning moments, and stabilizing moments for the structure.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

EngSolutions RCB Version 9.1.2 - License No: A27996-A21317 Page No.

1
============================================================================================
Company: CMG Engineer: CMG
Project: VIENTO 14:11:01 25/09/2024
============================================================================================

WIND LOADS NSR-10


Wind pressure
p = q G Cp rigid buildings
= q Gf Cp flexible buildings
qz = 0.00483 Kz Kzt Kd V² I (Kg/m²); V in Km/h

W I N D L O A D I N G P A R A M E T E R S

Basic wind speed (Km/h), V ....... = 80

V: 3-second gust speed at 10 m, with annual probability of 0.002

Importance factor, I ............. = 1.0

OCCUPANCY CATEGORY IMPORTANCE F A C T O R


(1) (2)
I Normal occupancy buildings 0.87 0.77
II Especial occupancy buildings 1.00 1.00
III Public assistance facilities 1.15 1.15
IV Essential facilities 1.15 1.15
(1): Non-hurricane prone regions with V=140-160 km/h
(2): Hurricane prone regions with V >160 Km/h

Exposure category ................. = C

ROUGHNESS DESCRIPTION
B Urban and suburban areas, wooded areas, obstructions >30ft
C Open terrain with scattered obstructions less than 30 ft
D Flat, unobstructed areas, wind over large bodies of water

Directionality factor, Kd ......... = 0.85

Topographic factor, Kzt ........... = 1.0

Kzt = (1 + K1 K2 K3)²

Wall pressure coefficients, Cp

Windward wall .............. = 0.8


Leeward wall (Wind X) ...... = -0.5
Leeward wall (Wind Y) ...... = -0.467
Side walls ................. = -0.7
Roof ....................... = 0.0

______________________________________________________________________

G U S T E F F E C T S F A C T O R S

Basic wind velocity, (Km/h) = 80


Exposure category ......... = C
Exposed height, (m) ...... = 5.125

X-direction Y-direction
----------- -----------
Estimated natural frequency, f(Hz) = 4.022 4.022
Height / Length ratio, H/L ....... = .499 .429
Structure clasification .......... = RIGID RIGID

Background response index, Q ..... = .912 .916 (Eq. B.6.5-4)


Resonant response factor, R1 *.... = .06 .064 (Eq. B.6.5-8)
Gh: Rigid - Simplified analysis .. = .85 .85 (Sec B.6.5.8.1)
Gh: Rigid - Complete analysis .... = .875 .877 (Eq. B.6.5-2)
Gf: Flexible -Analytical(2% dampng)= 1.129 1.133 (Eq. B.6.5-2)
Gf: Flexible -Analytical(1% dampng)= 1.13 1.134 (Eq. B.6.5-2)

Gust effects factor, G ........... = .875 .877

* 1% damping ratio. For damping ratio ß, R = R1 * (0.01/ß)^½

______________________________________________________________________
EngSolutions RCB Version 9.1.2 - License No: A27996-A21317 Page No. 2
============================================================================================
Company: CMG Engineer: CMG
Project: VIENTO 14:11:01 25/09/2024
============================================================================================

V E L O C I T Y P R E S S U R E

Floor Height Pressure


- z, m qz, K/m2
------ ------- --------

cub 5.11 23.087


2 2.57 22.545
1 0.0 22.545

______________________________________________________________________

A C C I D E N T A L T O R S I O N F O R W I N D L O A DS

X-direction Y-direction
----------- -----------

Accidental eccentricity as a
percentage of building dimension, (%)= 15 15

WY is Envelope of: WX is Envelope of:


Case 1: Pwy + Ply Case 1: Pwx + Plx
Case 2: 0.75 (Pwy + Ply) + Mt Case 2: 0.75 (Pwx + Plx) + Mt
Mt=0.75(Pwy+Ply)Bx ex Mt=0.75(Pwx+Plx)By ey
NOTE: Load cases 3 and 4 are handled through load combinations

______________________________________________________________________

A C C I D E N T A L E C C E N T R I C I T Y W I N D L O A D S

X-DIRECTION (WY) Y-DIRECTION (WX)


----------------- ------------------
Level ex ey
- (m) (m)
----- --------- ---------

cub 1.54 1.79


2 1.54 1.79

WY is Envelope of: WX is Envelope of:


Case 1: Pwy + Ply Case 1: Pwx + Plx
Case 2: 0.75 (Pwy + Ply) + Mt Case 2: 0.75 (Pwx + Plx) + Mt
Mt=0.75(Pwy+Ply)Bx ex Mt=0.75(Pwx+Plx)By ey
NOTE: Load cases 3 and 4 are handled through load combinations

______________________________________________________________________
EngSolutions RCB Version 9.1.2 - License No: A27996-A21317 Page No. 3
============================================================================================
Company: CMG Engineer: CMG
Project: VIENTO 14:11:01 25/09/2024
============================================================================================

Wind nodal forces:


Pw = Σ pz Ai Pl = Σ ph Ai
Ps = Σ ph Ai Pr = Σ ph Ai
Ai = Nodal tributary area

W I N D F O R C E S: X - D I R E C T I O N

Floor Height Windward Leeward Side Roof


No z, m Pw, Ton Pl, Ton Ps, Ton Pr, Ton
------ ------- -------- -------- -------- --------
cub 5.11 0.25 0.15 0.19 0.0
2 2.57 0.48 0.31 0.37 0.0
1 0.0 0.17 0.11 0.19 0.0

Base shear, V:Σ(Pw+Pl) .. = 1.47 ton


Building Weight, W ....... = 140.50 ton (V/W = 0.010)
Overturning moment
From horizontal forces . = 4.09 ton-m
From roof forces ....... = 0.0 ton-m
Total moment, Mo ....... = 4.09 ton-m
Stabilizing moment, Ms.... = 649.34 ton-m (Mo/Ms = 0.006)

______________________________________________________________________
EngSolutions RCB Version 9.1.2 - License No: A27996-A21317 Page No. 4
============================================================================================
Company: CMG Engineer: CMG
Project: VIENTO 14:11:01 25/09/2024
============================================================================================

Wind nodal forces:


Pw = Σ pz Ai Pl = Σ ph Ai
Ps = Σ ph Ai Pr = Σ ph Ai
Ai = Nodal tributary area

W I N D F O R C E S: Y - D I R E C T I O N

Floor Height Windward Leeward Side Roof


No z, m Pw, Ton Pl, Ton Ps, Ton Pr, Ton
------ ------- -------- -------- -------- --------
cub 5.11 0.21 0.12 0.22 0.0
2 2.57 0.42 0.25 0.43 0.0
1 0.0 0.21 0.12 0.15 0.0

Base shear, V:Σ(Pw+Pl) .. = 1.33 ton


Building Weight, W ....... = 140.50 ton (V/W = 0.009)
Overturning moment
From horizontal forces . = 3.43 ton-m
From roof forces ....... = 0.0 ton-m
Total moment, Mo ....... = 3.43 ton-m
Stabilizing moment, Ms.... = 717.55 ton-m (Mo/Ms = 0.005)

______________________________________________________________________