RCCB- ID B type

The RCCB-ID B type residual current circuit breakers provide earth leakage protection, ensuring safety against electric shocks and fire risks. They are designed for three-phase networks and can handle continuous fault currents from various sources, including variable speed drives and battery chargers. The breakers comply with IEC/EN standards and offer features such as electrical indication and compatibility with Schneider Electric's variable speed drives.

Uploaded by

Uğur Yildirim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views

RCCB- ID B type

The RCCB-ID B type residual current circuit breakers provide earth leakage protection, ensuring safety against electric shocks and fire risks. They are designed for three-phase networks and can handle continuous fault currents from various sources, including variable speed drives and battery chargers. The breakers comply with IEC/EN standards and offer features such as electrical indication and compatibility with Schneider Electric's variable speed drives.

Uploaded by

Uğur Yildirim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Protection RCCB-ID B type

Earth leakage protection

IEC/EN 61008, VDE 0664

b The RCCB-ID 125 A residual current circuit breakers provide:


PB101616_SE-35

062075N_SE-33

v protection of persons against electric shock by direct contact (30 mA),


v protection of persons against electric shock by indirect contact (u 300 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).
B type
The RCCB-ID B type residual current circuit breakers provide:
b protection in the event of a continuous fault current on three-phase networks
generated by:
v controllers and variable speed drives,
v battery chargers and inverters,
16766 16940 v backed-up power supplies.

b They include and also guarantee protection against fault currents:


PB100572-18

v sinusoidal AC residual currents (AC type),


v pulsed DC residual currents (A type).

They can be adapted to all the application cases defined in standards IEC 60364 and
16939
EN 50178.
b Schneider Electric guarantees that the type B RCCB-ID works correctly in
combination with the variable speed drives manufactured by Schneider Electric.

OFsp auxiliary
b Electrical indication: by OFsp auxiliary mounted to the left.
It has a double changeover switch indicating the "open" or "closed" position of the
RCCB-ID B type .

Accessories
b 4P sealable screw shield.

Catalogue numbers
RCCB-ID B type residual current circuit breakers
Type B Width in 9 mm
module
4P Sensitivity 30 mA 300 mA 300 mA s 500 mA
Rating 25 A 16750 16751 - - 8
DB123726

40 A 16752 16753 16754 16755


63 A 16756 16757 16758 16759
80 A 16760 16761 16762 -
125 A 16763 16764 16765 16766

Voltage rating (Ue) 230/400 V


Operating frequency 50 Hz

Auxiliary
Type Width in 9 mm
module
Contact OFsp Contact Voltage
1A 110 V DC 16940 1
E91415

22 14
12 6A 230 V AC (AC15)

21
11

Accessory
Type Number of pole
Screw shield (set of 10) for upstream or downstream 4P 16939

 version: 1.1 CM902002E.indd


Protection RCCB-ID B type (cont.)
Earth leakage protection

Connection
b By tunnel terminals for:
Type Tightening Copper cables
DB123736

torque Rigid Flexible or ferrule


11 mm
6,5 mm

DB112804

DB112805
PZ2

RCCB-ID B type 3 N.m 1 x 1.5 to 50 mm2 1 x 1.5 to 35 mm2


2 x 1.5 to 16 mm2 2 x 1.5 to 16 mm2
OFsp 0.8 N.m 1 to 1.5 mm2 1 to 1.5 mm2

Technical data
OFsp contact status, depending on the Electrical characteristics
position of the residual current circuit According to IEC 60947
breaker Insulation voltage (Ui) 400 V
Type Pollution degree 3
RCCB-ID Closed b - - Rated impulse withstand voltage (Uimp) 4 kV
B type
Open - b - According to IEC/EN 61008-1
Tripped on - - b Making and breaking 25/40 A 500 A
fault capacity (Im/IDm) 63/80 A 800 A
Contact 22/21 Open Closed Closed
125 A 1250 A
OFsp 12/11
14/11 Closed Open Open Surge current withstand No selective s 250 Â
(8/20 μs) without tripping Selective s 3 kÂ
Conditional rated short 25/40 A with FU 80 A gG fuse 10,000 A
circuit current (Inc/IDc)
63 A with FU 100 A gG fuse 10,000 A
DB122842

80/125 A with FU 125 A gG fuse 10,000 A


Additional characteristics
Degree of protection Device only IP20
IP40 with screw shield
Device in modular enclosure IP40
Insulation classe II
Endurance (O-C) Electrical > 2 000 cycles
Mechanical > 5 000 cycles

Indication of the status of the Operating temperature -25°C to +40°C

RCCB-ID B type via the 3-position Storage temperature -40°C to +85°C

toggle and front panel indicator


b Closed (red indicator)
b Tripped on fault (green indicator)
b Open (green indicator)

Weight (g)
Residual current circuit breakers and auxiliary
Type RCCB-ID B type OFsp
4P 450 40

Dimensions (mm)
DB122838

1040302_1

2P 4P
RCCB-ID B type Contact OFsp

CM902002E.indd version: 1.1 