Read this document carefully before using this device. The guarantee will be expired by device INPUT
demages if you don't attend to the directions in the user manual. Also we don't accept any Input Type Scale Range Accuracy
compensations for personal injury, material damage or capital disadvantages. NTC Sensor Typ 103AT-2 EN 60751 -60.0...150.0 °C -76.0...302.0°F ± 1% (for full scale) ± 1 Digit
at 25 °C - 10 kOhm
ENVIRONMENTAL CONDITIONS
ENDA ET2411 ON/OFF HEAT CONTROLLER Ambient/Storage temperature 0 ... +50 / °C -25... +70 °C(without icing)
Relative Humidity Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Thank you for choosing ENDA ET2411 ON/OFF Heat Controller. Protection Class According to EN60529; Front panel: IP65 Rear panel : IP20
Height Max. 2000m
- 77 x 35mm sized. Do not use the device in locations subject to corrosive and flammable gasses.
- Single NTC sensor input. °F C1 ELECTRICAL CHARACTERISTICS
Supply 230V AC +10% -20%, 50/60Hz or 12/24V AC/DC 10%
-
-
Zero point input shift.
Selectable heating or cooling control for C1 relay output.
°C Power Consumption Max. 3VA
- Selectable heating or cooling control. SET Wiring Power connector : 2.5mm² screw-terminal, Signal connector : 1,5mm² screw-terminal conenction.
- In the case of sensor failure, relay state can be set to ON or OFF. Line Resistance Max. 100ohm
Data Retention EEPROM (Min. 10 years)
- Upper and lower setpoint limits can be adjusted.
- Temperature unit can be selected as °C or °F. ENDA ET2411 EMC EN 61326-1 : 2013 (Performance criterion B is satisfied for EN 61000-4-3)
Safety Requirements EN 61010-1 : 2010 (Pollution degree 2, overvoltage category II)
- CE marked according to European Norms.
4 digits, 12.5mm, 7 segment red LED
R HS Indicator
OUTPUT
Konform C1 Output For 5A Models : 250V AC, 5A (resistive load), NO control output.
For 8A Models : 250V AC, 8A (resistive load), NO and NC control output.
1 - Supply Voltage 2 - Relay Current Selection For 16A Models : 250V AC, 16A (resistive load), NO control output.
Life Expectancy for Relay For 5A Models : 5. Mio. Switching for no-load operation; 100.000 switching for 5A resistive load at 250VAC.
230........230V AC 05.....5A Relay Output For 8A Models : 30. Mio. Switching for no-load operation; 300.000 switching for 8A resistive load at 250VAC.
Order Code : ET2411 - - 024........24V AC/DC 08.....8A Relay Output For 16A Models : 30. Mio. Switching for no-load operation; 100.000 switching for 16A resistive load at 250VAC.
1 2 012........12V AC/DC 16...16A Relay Output
SM.........7-24VAC/9-30VDC CONTROL
Control Type Single-setpoint and alarm control.
Control Algorithm
A/D Converter 12 bit resolution, 100ms sampling time.
ENDA ET2411 is intended for installation within control panels. Make sure that the device is used only for Hysteresis Adjustable between 0.1 and 20.0°C/F.
intended purpose. The shielding must be grounded on the instrument side. During an installation, all of the
cables that are connected to the device must be free of electrical power. The device must be protected against HOUSING
inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is not exceeded. Housing Type Suitable for flush-panel mounting according to DIN 43 700.
Dimensions W77xH35xD61mm
All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables.
Weight Approx. 215g (After packing)
These cables should not be close to the power cables or components. The installation and electrical connections must
be carried out by a qualified staff and must be according to the relevant locally applicable regulations. Enclosure Materials Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
ENDA INDUSTRIAL ELECTRONICS SN: XXXXXXXXX ENDA INDUSTRIAL ELECTRONICS SN: XXXXXXXXX ENDA INDUSTRIAL ELECTRONICS SN: XXXXXXXXX
ET2411-230-08
DIGITAL THERMOSTAT
ET2411-230-16
DIGITAL THERMOSTAT
ET2411-SM-05
DIGITAL THERMOSTAT Dimensions
Made in Turkey 8 680407 715299 Made in Turkey 8 680407 715367 Made in Turkey 8 680407 715350 77mm Depth 5mm
250V AC 8A
RESISTIVE LOAD
250V AC 16A
RESISTIVE LOAD
250V AC 5A
RESISTIVE LOAD
61mm
C1
NTC C1
NTC C1
NTC
°F C1
For removing mounting clamps:
NOTE: Fuse
Note:
Connection
SUPPLY: F 100 mA Cable Flush mounting
Switch 1) Mains supply cords shall meet the requirements of Panel
184-253V AC 5 Line
250V AC
230V AC
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
Flush mounting 2 clamp Rubber
Packing
50/60Hz 3VA
11 12 10 9 8 7 6 5 4 3 2 1
6 Neutral Supply clamp
supply switch shall bring the identification of the Panel cut-out
Fuse should Note:1) Panel thickness should
C1
1
250V AC 8A
Running Mode
Measured temperature Default value C1 Set value
SET
105 C1.SE. 100 100 101 102 101 If no key is pressed within 3 seconds, Running Mode is entered.
Programming Menu
SET SET SET
2. / 2 ET2411-E-25032019