PM-ANALYZE New
PM-ANALYZE New
PM-QUALITY PM-ANALYZE
WinCC
PM-MAINT PM-OPEN
PM-LOGON
PM-ANALYZE
What is new in V10.4
Process Management System WinCC Add-ons
Unrestricted © Siemens 2024 WinCC Competence Center Mannheim
Disclaimer
© Siemens 2024
Subject to changes and errors. The information given in this document only contains general descriptions and/or
performance features which may not always specifically reflect those described, or which may undergo modification in
the course of further development of the products. The requested performance features are binding only when they are
expressly agreed upon in the concluded contract.
Security information
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and
continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute
one element of such a concept. For more information about industrial security, please visit
https://www.siemens.com/industrialsecurity.
PM-ANALYZE
New Features in Version 10.4
Automatic Backups
MQTT Station
• Online Configuration
• Compatible with
• WinCC Unified
• WinCC V8
• and PM-WEB
• Online Configuration
• Compatible with
• WinCC Unified
• WinCC V8
• and PM-WEB
Please note:
For remote access, it must be ensured that
a suitable PM-IDP user is created and
used.
Page 18 Unrestricted © Siemens 2024 WinCC Competence Center Mannheim
New in Version 10.4
Separation of Event Datasets and their Triggers
Triggers are not defined within the Event Datasets anymore, but under the new node “Events”.
An instance under “Events” can be used with any number of Event Datasets.
Advantages:
• Smaller project segments since source data is not archived there.
• Therefore: Faster querying of data in project segments and
reduced storage requirements.
• Faster aggregation of source data of temporary archiving.
• The Interpolation/Rasterize
function allows for process
values to be aligned on a time
based grid.
Various options can be used to
customize the interpolation
calculation.
• Retrieve alarms in all languages
defined in the project.
64-Bit
• New @LastValues Station holds the last value written to any of the process value
archives including aggregation archives
• The values of these tags are updated every time a new entry is made into an archive
• Multiple triggers can by combined (“or” linkage) as needed (e.g. Temp > 80 OR State = Heating)
• Event datasets can also be automatically imported from text files for third party integration
Line
• Event dataset can be used to record data
structures from multiple sources (e.g. a line) Trigger: Batch Start&End
Sterilizer
• Event datasets can be hierarchical Washer Temperature
SterilizerTime
Trigger: Every 10min &
Trigger: None
SetpointChanged = True
• Drag and drop between PM-SERVER and Windows desktop/explorer and text editors
• PM-SERVER to Windows desktop/explorer => generates xml export file
• Windows desktop/explorer to PM-SERVER => imports xml file
• PM-SERVER to PM-SERVER => copy
• Available for
• State model definitions & instances
• Calculation schemas & instances
• Event dataset definitions
• Range dataset definitions
• Calculations
• Tag archives
• Event datasets
• Range datasets
E-Mail: [email protected]
Internet: https://www.siemens.com/process-management