Br_multiEA_5100_en
Br_multiEA_5100_en
multi EA 5100
Elemental Analysis
2
Simplified operation
■ System self-checks enable unattended operation and reliable results
■ Extensive preset method library (ASTM, EPA, ISO, etc.)
■ Auto-protection for cost reduction by predictive maintenance
Streamlined performance
■ High sensitivity, fewer replicates – fast analyses, high throughput
■ Eliminate extensive pretreatment
■ Time and matrix-optimized analysis
Accessories
ABD – automatic boat drive with cooled sample port
■ Automatic introduction of liquid and solid samples
■ Supports analysis of light volatile and reactive samples
Autoinjector
■ Safe injection of liquid samples up to 100 µL
■ Ideal solution for small sample series
multi EA 5100
Your Entire C/N/S/X Lab in One Device
4
Vertical and horizontal combustion in one device Work efficiently with smart features
Benefit from double furnace technology and take advantage As part of the multiWin software, the multi EA 5100
of both combustion methods to achieve the best results for contains an extensive method library with over 100
every sample matrix. The system will adapt to your sample methods. This makes analyses according to international
thanks to the easy-to-use tilting mechanism. The use of standards such as ASTM, EPA, DIN, ISO, and EN easy.
vertical systems has become standard for the fast, precise Preconfigured methods eliminate time-consuming method
determination of liquids and gases, particularly in the trace development results in fast, correct measurements. C/N/S/X
range. However, as sample complexity, volatility and viscosity determination of multiple elements can be simply carried
increase, it is necessary to use the horizontal mode. out in a one time analysis cycle. The changeover between
C/N/S and Cl determination takes place automatically,
without the need for manual modification of the analyzer.
Sample injection:
liquid/LPG/gaseous
Ar/O2
O2
Sample injection:
NOx
CO2 O2 solid/liquid/LPG/gaseous
HCl
Ar/O2
SO₂
C/N/S analysis
S N C SO₂ CO2
NOx
HCl
Dryer
Cl
Coulometer Light guide with flame sensor Quartz boat Cooled sample inlet
Cl analysis – (EOX/TOX/AOX)
5
Cl N
S S C/TOC
(Coul) (UV)
Operation range*1 relative: relative: 10,000 mg/L relative: 10,000 mg/L relative: 40,000 mg/L relative: 100,000 mg/L
100 wt-% (organics) absolute: 100 µg N absolute: 100 µg S absolute: 200 µg S absolute: 1.00 mg Cl
10,000 mg/L (water)
absolute: 500 mg C
Limit of detection*1 relative: relative: 10 µg/L relative: 5 µg/L relative: 600 µg/L relative: 50 µg/L
100 µg/lL (organics) absolute: 0.4 ng N absolute: 0.2 ng S absolute: 0.2 ng S absolute: 10 ng Cl
200 µg/L (water)
absolute:
50 ng C (organics)
100 ng C (water)
Compliance*1 ISO 8245 // ASTM D5762, D4629, ASTM D5453, D6667, ASTM D3120, D3246 ASTM D5808,
DIN EN 1484 D6069, D7184 // D7183, D7551 // DIN // DIN EN ISO 16591 D4929-B, D7457 // EPA
DIN 51444 // UOP 936, EN 15486, 20846, 9076, 9020-B // ISO
971, 981 17178 // UOP 987- 9562 // DIN 38418-17,
Part A 38414-18
*1 depending on configuration, method settings, sample quantity, purity of the vessels, chemicals and gases used, and the qualification of the operator
7
intermediats, fuels, heating oil, distillation residues, cooling, process and waste waters
additives, biodiesel, bioethanol, etc. ■ TOX/AOX/EOX in soil, sewage sludge and sediments
■ Analysis of lubricants, transmission and transformer ■ EC/OC for particulate diesel engine emissions for
alcohols, aldehydes, ketones, etc. ■ N/S/Cl in alcohols, acetic and lactic acid
■ Analysis of raw materials such as butane, propane