The multi EA 5100 is a versatile device designed for the analysis of sulfur, nitrogen, chlorine, and carbon in various sample types, including solids, liquids, and gases. It features advanced technology for high-throughput analysis, self-check systems for reliability, and a wide range of applications without the need for device modification. The system is tailored for industries such as oil and gas, petrochemical, and environmental testing, ensuring efficient and accurate measurements.

Uploaded by

tin_tin_tin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views8 pages

Br_multiEA_5100_en

The multi EA 5100 is a versatile device designed for the analysis of sulfur, nitrogen, chlorine, and carbon in various sample types, including solids, liquids, and gases. It features advanced technology for high-throughput analysis, self-check systems for reliability, and a wide range of applications without the need for device modification. The system is tailored for industries such as oil and gas, petrochemical, and environmental testing, ensuring efficient and accurate measurements.

Uploaded by

tin_tin_tin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Your Entire C/N/S/X Lab in One Device

multi EA 5100
Elemental Analysis
2

Meet the multi EA 5100!


The multi EA 5100 is your flexible all-round solution for sulfur, nitrogen,
chlorine and carbon analysis in solids, liquids and gases. QC analysis, research
and contract labs will benefit from its combination of outstanding robustness
and sensitivity, plus quality, service and cost-effective 24/7 high-throughput
analysis in every matrix.

Applications beyond expectations


■  xtensive range of applications without device modification
E
■ C/N/S/X in solid, liquid and gaseous samples plus TOC,
AOX/TOX, EOX and EC/OC
■ Vertical and horizontal combustion combined in one system
■ Easy extension at any time

Simplified operation
■ System self-checks enable unattended operation and reliable results
■ Extensive preset method library (ASTM, EPA, ISO, etc.)
■ Auto-protection for cost reduction by predictive maintenance

Streamlined performance
■ High sensitivity, fewer replicates – fast analyses, high throughput
■ Eliminate extensive pretreatment
■ Time and matrix-optimized analysis

One-stop service solutions


■ Commissioning, training, maintenance and service contracts
■ Broad range of tailor-made calibration solutions and electrolytes
■ Online and on-site training courses
3

Accessories
ABD – automatic boat drive with cooled sample port
■ Automatic introduction of liquid and solid samples
■ Supports analysis of light volatile and reactive samples

MMS – Multi Matrix Sampler


MMS with liquids rack ■ Automatic introduction of up to 112 liquid or 35 solid
samples
■ Vertical and horizontal operation mode
■ Extendable for cooling or heating option

Autoinjector
■ Safe injection of liquid samples up to 100 µL
■ Ideal solution for small sample series

GSS module – Gas Sampling System


■ Introduction of gaseous samples
■ Doses of unpressurized or pressurized samples at variable
LPG 2.0 module
dosage speeds

LPG 2.0 module


■ For direct dosing of pressurized liquefied gases
■ Fully automatic dosage, evaporation, and injection

GSS/LPG combi module


■ For dosing of liquefied and pressurized gases
■ Separate sample branches prevent cross-contamination

multi EA 5100
Your Entire C/N/S/X Lab in One Device
4

Elevate Your Measurement Performance


Smart safety features and pre-configured methods simplify your analysis. Get
unparalleled application variety in elemental analysis with the multi EA 5100.

Versatile and future-proof Maximum operation safety guaranteed


The multi EA 5100 analyzes carbon, nitrogen, sulfur and The multi EA 5100 is equipped with a safety system that
chlorine in solids, liquids and gases without the need for guarantees the long lifetime of the individual components.
time-consuming device modification. The device enables The integrated Self Check System automatically monitors
the determination of important environmental parameters and optimizes relevant system parameters, guaranteeing
(TOC/AOX/TOX/EOX). The modular design allows the system a trouble-free and safe operation. The auto-protection
to be adapted to individual requirements. The base unit can feature effectively protects the system from damage caused
be extended with additional detection modules at any time. by particles, aerosols and liquids. The multi EA 5100
In addition, a wide range of accessories is offered to boost also offers predictive maintenance, which saves time on
analysis throughput or carry out gas/LPG analyses. maintenance effort and prevents system failures.

Vertical and horizontal combustion in one device Work efficiently with smart features
Benefit from double furnace technology and take advantage As part of the multiWin software, the multi EA 5100
of both combustion methods to achieve the best results for contains an extensive method library with over 100
every sample matrix. The system will adapt to your sample methods. This makes analyses according to international
thanks to the easy-to-use tilting mechanism. The use of standards such as ASTM, EPA, DIN, ISO, and EN easy.
vertical systems has become standard for the fast, precise Preconfigured methods eliminate time-consuming method
determination of liquids and gases, particularly in the trace development results in fast, correct measurements. C/N/S/X
range. However, as sample complexity, volatility and viscosity determination of multiple elements can be simply carried
increase, it is necessary to use the horizontal mode. out in a one time analysis cycle. The changeover between
C/N/S and Cl determination takes place automatically,
without the need for manual modification of the analyzer.

Sample injection:
liquid/LPG/gaseous

Ar/O2
O2

Sample injection:
NOx
CO2 O2 solid/liquid/LPG/gaseous
HCl
Ar/O2
SO₂

C/N/S analysis
S N C SO₂ CO2
NOx
HCl
Dryer

Cl
Coulometer Light guide with flame sensor Quartz boat Cooled sample inlet
Cl analysis – (EOX/TOX/AOX)
5

Outstanding Analysis and Service Quality


The multi EA 5100 guarantees competitive advantage of your lab in terms
of cost-effectiveness and analysis quality for years to come.

Increased uptime Outstanding support throughout the product life cycle


Fast analysis is possible in three minutes for liquids and six We offer you competent service and support throughout
minutes for solids. With a high sample throughput of over the life cycle of your product. We provide system
160 liquid samples and up to 90 solid samples per day, costs configuration tailored to your specific needs, instrument
are kept very low. Reduced consumption of consumables and commissioning, and method development. You‘re also
less time spent on maintenance, minimize costs even further. invited to take part in our comprehensive training, which
includes on-site user seminars and workshops. Benefit from
Optimal combustion for accurate measurements online training courses and a variety of tutorial videos which
The integrated flame sensor guarantees matrix-optimized, simplify analysis and device maintenance.
quantitative combustion and prevents soot formation, For direct regional support, our international network
thereby solving a problem common to other conventional of experts is at your disposal. We also offer individual
instruments. With this technology, samples can be analyzed maintenance and service contracts.
quickly and reliably, even if their characteristics are unknown.
6

Customize the Analyzer to Your Needs!


Mix and match the multi EA 5100 analysis modules to suit your needs –
and expand the system any
time you want.

Cl N

S S C/TOC
(Coul) (UV)

Ready for a variety of applications


The unmatched detector diversity of sulfur, nitrogen, carbon and chlorine opens up a wide range of applications and offers
the perfect solution for every elemental analysis. Individual detection systems can be combined and adpated as required.

Elements Carbon Nitrogen Sulfur Chlorine

Measuring principle NDIR spectrometry Chemiluminescence UV fluorescence Coulometry Coulometry

Operation range*1 relative: relative: 10,000 mg/L relative: 10,000 mg/L relative: 40,000 mg/L relative: 100,000 mg/L
100 wt-% (organics) absolute: 100 µg N absolute: 100 µg S absolute: 200 µg S absolute: 1.00 mg Cl
10,000 mg/L (water)
absolute: 500 mg C

Limit of detection*1 relative: relative: 10 µg/L relative: 5 µg/L relative: 600 µg/L relative: 50 µg/L
100 µg/lL (organics) absolute: 0.4 ng N absolute: 0.2 ng S absolute: 0.2 ng S absolute: 10 ng Cl
200 µg/L (water)
absolute:
50 ng C (organics)
100 ng C (water)

Compliance*1 ISO 8245 // ASTM D5762, D4629, ASTM D5453, D6667, ASTM D3120, D3246 ASTM D5808,
DIN EN 1484 D6069, D7184 // D7183, D7551 // DIN // DIN EN ISO 16591 D4929-B, D7457 // EPA
DIN 51444 // UOP 936, EN 15486, 20846, 9076, 9020-B // ISO
971, 981 17178 // UOP 987- 9562 // DIN 38418-17,
Part A 38414-18

*1 depending on configuration, method settings, sample quantity, purity of the vessels, chemicals and gases used, and the qualification of the operator
7

Meeting Industry Needs


The versatility and smart features of the multi EA 5100 make it a universal
talent that can be used in various fields, particularly in the oil and gas,
petrochemical and chemical sector.

For the chemical, oil and gas industry


and beyond
With its broad application spectrum and
smart features, the multi EA 5100 is
ideal for industrial control labs, contract
labs and state authorities in the oil
and gas, petrochemical and chemical
industries. Applications include process
control, material testing and waste
management. Features such as flame
sensor technology for matrix-optimized
sample digestion – including most
difficult matrices such as oils, VGO,
polymers and liquefied gases – and
the integrated method library are
indispensable for easy routine analysis.

Oil & Gas Environment


■ Analysis of mineral oil, natural gas, process ■ Determination of TOC/TOX/AOX/EOX in surface,

intermediats, fuels, heating oil, distillation residues, cooling, process and waste waters
additives, biodiesel, bioethanol, etc. ■ TOX/AOX/EOX in soil, sewage sludge and sediments
■ Analysis of lubricants, transmission and transformer ■ EC/OC for particulate diesel engine emissions for

oil, brake and hydraulic fluids, etc. monitoring air quality

Chemicals & Materials Food & Agriculture


■ Analysis of aromatic and aliphatic hydrocarbons ■ Carcinogenic Cl in fats, oils and waxes
■ Analysis of waxes, fatty acids, dyes, solvents such as ■ TN in sugar and starch

alcohols, aldehydes, ketones, etc. ■ N/S/Cl in alcohols, acetic and lactic acid
■ Analysis of raw materials such as butane, propane

and additives Power & Energy


■ Analyses for certification to N/S/Cl standards, ■ TS/TCl analysis of fuels such as coal, fuel oil, natural
e.g. for the petrochemical industry gas, derived fuels such as wood, straw etc.
■ Analysis of polymers (PP, PE, PC, caoutchouc) ■ TOC/TOX/AOX in waste water
Headquarters
Förster & Borries GmbH & Co. KG
© Analytik Jena AG
en · 02/2020 · 888-31004-2-B

Analytik Jena AG Pictures: ­Analytik J­ ena AG, p. 8: iStockphoto®/sdlgzps, Adobe©/YvanDube


Konrad-Zuse-Str. 1 Subjects to changes in design and scope of delivery as well as further technical development!
07745 Jena ⋅ Germany

Phone +49 3641 77 70


Fax +49 3641 77 9279
[email protected]
www.analytik-jena.com

You might also like