; 8051 Assembly Language Example

This document is an assembly language program for the 8051 microcontroller that interfaces with an LCD and a MAX30100 pulse oximeter using I2C communication. It initializes both devices, continuously reads BPM and SpO2 values from the MAX30100, and displays them on the LCD. The program includes subroutines for I2C initialization, reading data, and displaying values on the LCD.

Uploaded by

nikhilkotra1043
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views

; 8051 Assembly Language Example

This document is an assembly language program for the 8051 microcontroller that interfaces with an LCD and a MAX30100 pulse oximeter using I2C communication. It initializes both devices, continuously reads BPM and SpO2 values from the MAX30100, and displays them on the LCD. The program includes subroutines for I2C initialization, reading data, and displaying values on the LCD.

Uploaded by

nikhilkotra1043
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 2

; 8051 Assembly Language Example

ORG 0H ; Program start

; Define the LCD I2C Address (0x27)


LCD_ADDR EQU 0x27

; Pulse Oximeter (MAX30100) I2C Address (Use the actual address)


MAX30100_ADDR EQU 0xAE

; Declare variables for BPM and SpO2


BPM DATA 30H
SPO2 DATA 31H

; Initialize LCD (I2C) and MAX30100


INIT_LCD:
; I2C initialization code for LCD
CALL I2C_INIT
CALL LCD_CMD_INIT

INIT_MAX30100:
; I2C initialization code for MAX30100
CALL I2C_INIT
CALL MAX30100_INIT

; Main Loop
MAIN_LOOP:
; Read BPM and SpO2 values from MAX30100
CALL READ_MAX30100

; Update the LCD display with BPM and SpO2


CALL LCD_CLEAR
CALL DISPLAY_BPM
CALL DISPLAY_SPO2

; Wait some time (1 second or so)


CALL DELAY
SJMP MAIN_LOOP

; Read BPM and SpO2 values from MAX30100


READ_MAX30100:
; Read BPM from MAX30100 using I2C (example)
MOV A, MAX30100_ADDR
CALL I2C_READ
MOV BPM, A

; Read SpO2 from MAX30100 using I2C (example)


MOV A, MAX30100_ADDR
CALL I2C_READ
MOV SPO2, A

RET

; Display BPM on LCD


DISPLAY_BPM:
; Code to write BPM to the LCD (display the value stored in BPM)
CALL LCD_WRITE
RET
; Display SpO2 on LCD
DISPLAY_SPO2:
; Code to write SpO2 to the LCD (display the value stored in SPO2)
CALL LCD_WRITE
RET

; Delay Subroutine (for timing)


DELAY:
MOV R0, #200 ; Adjust as per required delay time
DELAY_LOOP:
NOP
NOP
DJNZ R0, DELAY_LOOP
RET

; I2C Initialization
I2C_INIT:
; Code to initialize I2C (this can include setting up clock and data pins)
RET

; LCD Command Initialization


LCD_CMD_INIT:
; Code to initialize LCD with command sequence (I2C)
RET

; LCD Write Command


LCD_WRITE:
; Code to send a byte to the LCD (using I2C)
RET

; I2C Read Command


I2C_READ:
; Code to read a byte from I2C (MAX30100 or LCD)
RET

END