CAT Comm Adaptor Setting- K317-7484DS Tool Group – CA..
CAT Comm Adaptor Setting- K317-7484DS Tool Group – CA..
html
1 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
Align and attach the DB25 connector end of the USB PC cable to the “PC cable” end connection on the Comm Adapter 3.
2 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
Plug the USB Connector end of the PC cable into the USB port of the PC
3 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
After connecting the Comm Adapter 3 to the PC, connect the DB15- style connector end of the data link cable to the “Data Link” connection on the Comm Adapter 3.
4 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
Connect the other end of the data link cable to the service connector on the product.
5 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
The lights on the front of the Comm Adapter 3 will sequentially glow from the top to the bottom of the device and the diagnostic test will begin. The service tool is now ready to be
started.
NOTE: The Power light on the Comm Adapter will glow if the data link is powered (machine power is on) or if the USB connector is plugged into the PC.
NOTE: For more information on the Comm Adapter 3, please refer to the Caterpillar Communications Adapter 3 Tool Operating Manual
In order for Electronic Technician to work with the Communication Adapter 3, the settings must be changed to select the Communication Adapter 3 as the
Communication Interface Device:
Step 1 Start Caterpillar Electronic Technician.
Step 2 Click the Stop Connect button when it appears. Step 3 Select the Utilities menu.
Step 4 Choose “Preferences...”
Step 5 Select the Communications tab.
Step 6 Select Caterpillar Comm Adapter 3 (RP1210) and click OK.
NOTE: Because a growing number of products require multiple data link service, the “Enable Dual Datalink Service” checkbox has been pre-selected. Servicing ECMs
on more than one data link requires this checkbox to be enabled. Failure to do this will result in undetected ECMs and reduced functionality
6 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
Communication Hardware
Adapters are service tools consisting of a portable hardware adapter and a software PC program designed to run under Microsoft® WindowsTM. MPSI Pro- Link is a portable
computer diagnostic analyzer. To service using Caterpillar Electronic Technician, one of the following devices is required:
• K317-7484DS Tool Group – Caterpillar Communication Adapter 3 For additional requirements, see “Setting up Caterpillar Communication Adapter 3”
• NOTE: Engines that do not have the service connector may also require the 140-9442 ATA\CDL T-Adapter.
Exceptions
The requirements for Hydraulic Excavators B-Series (HEX) are the following:
127-9797 - Cable Assembly HEX to PC Adapter cable In the Communications tab of the Preferences dialog box, select the Communication Adapter option from the Communication
Interface Device drop-down list. Then click the Advanced button. Select the 19200 baud rate radio button. Click OK
7 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
Requirements
Requirements:
Description
Part Number
Optional Cables:
Description
Part Number
8 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
9 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
Align and attach the DB25 connector end of the serial cable to the “PC Cable” end of the Comm Adapter II
Connect the other end (RS-232 end) of the serial cable to the communication port of the PC.
10 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
To connect the Communication Adapter II to the data link, perform the following steps:
Step 1 After connecting the Comm Adapter II to the PC, connect the DB15- style connector end of the data link cable to the “Data Link” end of the Comm Adapter II.
Step 2 Connect the other end of the data link cable to the product. If the data link is powered (machine power is on), the Power light on the Comm Adapter II will glow and the
diagnostic test will begin. The lights on the front of the Comm Adapter II will sequentially glow from the top to the bottom of the device. The service tool is now ready to be started.
11 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
NOTE: Use the Comm Adapter II Toolkit version 4.0.12 drivers to update the Comm Adapter II.
NOTE: Use the serial port only to upgrade the Communication Adapter II. Do not use the Parallel port.
Instructions
Step 1 Make sure the Comm Adapter II is connected to the PC and the Power light is on.
Step 2 Go to the Start menu on the computer. Choose All Programs ->
Caterpillar Comm Adapters -> Comm Adapter Toolkit.
Step 3 The Toolkit application will start up and display the Summary screen.
Step 4 Choose the Application Firmware Flash icon _______ . Then click the
Select File button. The Select Firmware Flash File dialog box is displayed.
Step 5 The following files should be listed on the right: ca2vi2.apf – application firmware
Step 6 Highlight the ca2v3i1.0.apf file and click the OK button. Step 7 Click the Begin Flash button to start the download.
Step 8 A dialog box showing the download progress will appear. The download should take less than 45 seconds.
NOTE: All protocol lights on the front of the Comm Adapter II will blink while the firmware is flashed.
Step 9 When the download is complete, a dialog box will appear, allowing a return to the Toolkit Summary screen, a return to the Flash screen, or an Exit from the toolkit.
12 of 13 3/17/2010 10:00 AM
K317-7484DS Tool Group – Caterpi http://www.dieselsolutions.com/k3177484ds_tool_group__caterpil.html
Step 2 Click the Stop Connect button when it appears. Step 3 Select the Utilities menu.
Step 6 Change the Communication Interface Device to “Caterpillar Comm Adapter II (Dual Data Link/Serial IP)” and click OK.
Step 7 “COM1” should be selected. This application firmware only supports Serial communications.
13 of 13 3/17/2010 10:00 AM