0% found this document useful (0 votes)
25 views5 pages

Process CalibratoR Mt100

The MicroTech MT100 Multifunction Process Calibrator is a versatile tool that can source and measure various process parameters including mA, volts, temperature, frequency, and resistance, making it ideal for calibration and troubleshooting. It features a user-friendly design with a backlit display, operates on a rechargeable battery, and is suitable for harsh field conditions. The device supports multiple operating modes and offers high accuracy, making it a comprehensive solution for process instrumentation needs.

Uploaded by

khoshgamir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views5 pages

Process CalibratoR Mt100

The MicroTech MT100 Multifunction Process Calibrator is a versatile tool that can source and measure various process parameters including mA, volts, temperature, frequency, and resistance, making it ideal for calibration and troubleshooting. It features a user-friendly design with a backlit display, operates on a rechargeable battery, and is suitable for harsh field conditions. The device supports multiple operating modes and offers high accuracy, making it a comprehensive solution for process instrumentation needs.

Uploaded by

khoshgamir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

MicroTech Multifuntion Process

Calibrator

With the MicroTech MT100 Multifunction Process Calibrator,


you can easily source and measure almost any process
parameter and process device sensors. Measure and source
mA, volts, temperature (RTDs and thermocouples), frequency
and ohms.

Whether you’re calibrating instruments, troubleshooting a


problem or running routine maintenance, MicroTech MT100
process calibrators can help you get the job done faster. It
does so many different tasks, so quickly and so well, it’s the
only process calibrator you need to carry

MicroTech MT100 can generate the following signals -


● DC Voltages from 0 to 11V & DC Mini Voltages from 0
to 110mV
● Current Signals from 0 to 24mA ● HART
● Resistance from 0 to 2200 ohms ● Modbus
● Frequency 0 to 10Hz
● Thermocouple Simulation Signal
● RTD like PT100, PT1000, Cus50
● 24V Fixed Voltage for Testing
MicroTech MT100 is ready to perform as a powerful, yet
easy-to-use field calibrator. Its simple controls, with menus,
make operation easy and the backlit display provides better
visibility in poor light. It features a small, streamlined shape
and a rugged, reliable design that makes it ideal for standing
up to harsh field conditions.

Applications
● Multifunctional Sensor Calibrator: Calibrate
temperature, pressure, voltage, current, resistance, and
frequency. Since it both measures and sources, you
can troubleshoot and calibrate all with one rugged tool
● Multifunctional Sensor Simulator: Simulate multiple
sensors for troubleshooting and debugging systems.
Using this calibrator, engineers can identify the fault in
the sensor, controller or wiring by simulating sensor
output signals and running carrying out test procedures.
● Hand-Held Operation. Small enough to fit easily into a
tool bag and to use in tight spaces. Runs an entire shift on a rechargeable Li-ion battery
pack. Great for testing on the field.
● 2 operating modes: Measure & Source (generate) —enable technicians to troubleshoot,
calibrate, or maintain instrumentation with just one tool.

Page 1
MicroTech MT100 Multifuntion
Process Calibrator
● The signal calibrator can output a user-defined signal
when a user enters into signal value through digit buttons.
● Simulation and measurement of thermocouple and temperature sensors like PT100,
PT1000, CU50.. etc.
● Debugging of industrial field PLCs
● Process Instrumentation: Signal Generators, Signal measurement, Valve Adjustment,
Inverter control
● PLC & Control Panel debugging by bypassing sensors and sensor calibrations
● LED & Equipment Testing or Control

Versatile Troubleshooting Tool

Engineers can power Sensor Transmitters under test using the inbuilt 24V loop supply with
simultaneous mA measurement so you can test a transmitter out of the circuit and better isolate
problems.

Source mA with simultaneous pressure measurement to conduct valve and I/P (Input
current/Output pressure) tests in a single device. You can also test flow meters with frequency and
CPM (counts per minute) functions and perform fast linearity tests with auto-step and auto-ramp
features so you can quickly verify the mA signal at different output levels.

It can output and measure 4 to 20mA Current, Voltage, Frequency Pulses, Thermocouple and
RTD Sensor. It is widely used as an mV mA calibrator, temperature calibrator, frequency signal
calibrator, 4-20mA loop calibrator, multimeter, etc. It supports full function operating mode and
user-defined output setting.

Features
● High accuracy of 0.025% +1/2 digits; widely used as frequency calibrator, mA mV loop
calibrator, temperature calibrator, etc.
● Have a full-function operating mode, the user can enter any value through digits buttons,
and the calibrator outputs a signal directly
● Signal output simulation and measurement: 0-10KHz frequency, 4-20mA source or passive
signal, 0-11V, 0-110mV, 20-400Ω, standard R, E, S, K, J, B, T, N type thermocouple, PT100,
CU50, 24V outputs, etc.
● Offers easy and convenient handheld operation. 2200mAH rechargeable battery inside, has
battery status indicator, very suitable and convenient to use indoors or outdoors in industrial
sites.
● High-resolution colour LCD display, has backlight for different lighting conditions, large
screen clear display
● Can be used as signal generator, frequency calibrator, and multifunction process calibrator.
● Have description in Hz, V, mV, mA, RTD, TC, Step, and Ω keys, it enables the user to
operate it easily
● Internal polarity Reverse connection and Over current protection; Protection voltage 30V

Page 2
MicroTech MT100 Multifuntion
Process Calibrator

Technical Specifications
Output Parameters
FUNC OUT UNIT RANGE SET STEP ACCURACY (SP: setting point)
DC. V V 0~11.00V 0.01/0.1/1 ±0.025%SP ±0.004V
DC. mV mV 0~110.00mV 0.1/1/10 ±0.025%SP ±0.02mV
Sink/Source/Prog
DC. mA 0~24.00mA 0.01/0.1/1/4 ±0.025%SP ±0.004mA
ram
0~400Ω 1/10/0100 ±0.025%SP ±0.3Ω
Ohm Ω
400~2200Ω 1/10/0100 ±0.05%SP ±1.5Ω
Frequency KHz 0-10 0.01/0.1/1 ±0.05%SP ±2Hz
R 0~1700℃
S 0~1600℃
B 500~1800℃ ±0.1%SP ±3℃

±0.05%SP ±0.5℃ (K)


K -200~1370℃
TC 1/10/0100
±0.05%SP ±0.3℃ (E)

±0.05%SP ±0.4℃ (J)


E -200~1000℃
J -200~1200℃ ±0.05%SP ±0.5℃(T)
T -200~400℃
N -200~1300℃ ±0.05%SP ±0.8℃ (N)
PT1000 -50~300℃ ±0.1%SP ±0.5℃
RTD Pt100 -200~850℃ 1/10/0100 ±0.1%SP ±0.8℃
Cu50 -50~150℃ ±0.1%SP ±1.5℃
24V 24V: Cannot be set.
Current
24V NONE
measurement:0~24.0
mA 00 mA

Page 3
MicroTech MT100 Multifuntion
Process Calibrator

Measurement Parameters

ACCURACY (RD: Read


FUNC UNIT RANGE RESOLUTION
number)

DC.V V -30~30.000V 0.001V ±0.025%RD ±0.004V

DC. mV mV -150~150.00mV 0.01mV ±0.025%RD ±0.02mV

DC. mA mA -30~30.000mA 0.001mA ±0.025%RD ±0.004mA

0~999.9Ω 0.1Ω ±0.025%RD ±0.2Ω


Ohm Ω
1000-2500 1Ω ±0.025%RD ±1Ω

Frequency KHz 0-10 0.001 ±0.05%RD ±2Hz

R 0~1700℃

S 0~1600℃ ±0.1%RD ±3℃ (R,S,B)

B 500~1800℃

K -200~1370℃
TC 0.1℃
E -200~1000℃ ±0.025%RD ±0.5℃ (K)
±0.025%RD ±0.3℃ (E)
J -200~1200℃ ±0.025%RD ±0.4℃ (J)
±0.05%RD ±0.5℃(T)
T -200~400℃ ±0.025%RD ±0.8℃ (N)

N -200~1300℃

Pt1000 -50~300℃ ±0.1%RD ±0.5℃

RTD Pt100 -200~850℃ 0.1℃ ±0.1%RD ±0.8℃

Cu50 -50~150℃ ±0.1%RD ±1.5℃

0~9990 engineering
unit (for current
Range switch mA measurement and (related to engine
measure the current
of 24V output)

Page 4
MicroTech MT100 Multifuntion
Process Calibrator

Terms and Conditions Agreement


Read and understand this catalogue.
Please read and understand this catalogue before purchasing the products. Please consult your MicroTech MT100
sales/technical representative if you have any questions or comments.
Warranties.
(a) Warranty. MicroTech MT100 does not offer any warranty/guarantee/replacement/returns for products once sold. Since these
products are used in research/testing/production with other components, it is beyond our scope to determine the working of our
product in your application. MicroTech disclaims all other warranties, express or implied.
(b) Limitations. MicroTech MT100 MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. THE BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS
OF THEIR INTENDED USE.
MicroTech MT100 further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right.
(c) Buyer Remedy. MicroTech MT100 sole obligation hereunder shall be, at MicroTech MT100s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii)
repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product;
provided that in no event shall MicroTech MT100 be responsible for warranty, repair, indemnity or any other claims or expenses
regarding the Products unless MicroTech MT100 analysis confirms that the Products were properly handled, stored, installed and
maintained and not subject to contamination, abuse, misuse or inappropriate modification or any other reason. Return of any
Products by Buyer must be approved in writing by MicroTech MT100 before shipment. MicroTech MT100 Companies shall not be
liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic
components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or
information is given orally or in writing, are not to be construed as an amendment or addition to the above warranty. contact your
MicroTech MT100 representative for published information.
Limitation on Liability; Etc.
MicroTech MT100 COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE
PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of MicroTech MT100 Companies exceed the individual price of the Product on which liability is
asserted. Suitability of Use. MicroTech MT100 Companies shall not be responsible for conformity with any standards, codes or
regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request,
MicroTech MT100 will provide applicable third party certification documents identifying ratings and limitations of use which apply to
the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination
with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining
appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application
responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE MicroTech MT100 PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
MicroTech MT100 Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof. Performance Data.
Data presented in MicroTech Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of MicroTech test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the MicroTech Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to
change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your MicroTech representative at any time to
confirm actual specifications of purchased Product. Errors and Omissions. Information presented by MicroTech Companies has
been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading
errors or omissions.

Page 5