Keli Pumps - Solar Products - Catalogue 2020
Keli Pumps - Solar Products - Catalogue 2020
CATALOGUE
SOLAR
PRODUCTS
2020
2 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
INDEX
PERIPHERAL VANE BOOSTER PUMP KIT DC SOLAR 4
BOREHOLE MOTORS 9
4” 0.75KW - 5.5KW 220V 3 PHASE
4” 7.5KW - 380V 3PHASE
6” 7.5KW - 37KW 380V 3 PHASE
This document contains hyperlinks. If you are using the electronic PDF copy you do not need to go through the entire
document to get to the required page, you can simply click on the required page on your index page. Click on the logo on
top to return to the Index page.
MATERIAL:
Pump Casing: Cast Iron
Motor body: Aluminium
Impeller: Brass
Motor: 100% Copper
PRODUCT FEATURE:
Clean water DC Booster pump
Flow: 1-2 m³/h
DC Brushless Motor
WORKING CONDITIONS:
Non-corrosive water
Max temperature: 40°c
PH: 6.5 - 8.5
LSQB2/26-
BRASS 36 275W 275W X 36V 33.33 2 26 6 1” 7.2
24/250
CONNECTION DIAGRAM
LSQB2/26-36/250
275 Watt x 36Volt
Booster Pump Set
Control Panel
2 x 12v Batteries
Regulator
- +
12v 12v
+ -
REGULATOR
• Use of the latest charging technologies combined with System can be connected to two
state of charge determination to enable optimal battery 12v deep cycle batteries (in series
maintenance and module power monitoring for up to 2880 = 24v) for night timeuse. This
Watt of connected power. will ensure that you have approx
• A large display informs the user about all operating modes 1 ½ hours continues duty without
with the aid of symbols. sunlight.
PRODUCT FEATURE:
180W
• Compact structure with high efficiency, low noise and pollutant free.
• Speed controller for accommodating low yield boreholes.
• Soft start electrical control panel provides protection against under-voltage, over
voltage, over-pumping, overloading and provides waterless automatic recovery
• Easy installation, maintenance-free, safe and reliable.
• DC Brushless Motor:
Max Water Submersion Depth : 20m (180W) & 50m (250W - 750W)
Max Flow: 2m3/h
Max Head: 110m
• Probe for monitoring water level in borehole.
• Probe for monitoring water level in tank.
APPLICATION:
Suitable for installations in boreholes, wells, rivers, dams and tanks with minimum ID
Ø 80mm.
250W - 750W
WORKING CONDITIONS:
• Non-corrosive water with a volume ratio of sand content not exceeding 1% and
the particle size not exceeding 0.5mm.
• Max pumped liquid temperature: 40°C
• PH capability: 6.5 - 8.5
*Note: For distance between PV Panels and Inverter, do not exceed 3 meters (cable length) when using 2.5mm2 cable.
3LSS1.2/85- l/min 20.33 18.33 16.66 14.16 11.66 8.33 5 3.33 1.66 - - -
0.35 0.47 36 2 x 275 36V X 550W
24/350 m3/h 1.2 1.1 1.0 0.85 0.7 0.5 0.3 0.2 0.1 - - -
l/min 33.33 33.33 31.33 27.83 24.33 20.83 18.33 14 12 7.5 5 1.66
3LSS2/110-72/750 0.75 1 45 3 x 330 45V X 990W
m3/h 2.0 2.0 1.88 1.67 1.46 1.25 1.1 0.84 0.72 0.45 0.3 0.1
275 Watt x 36 Volt 275 Watt x 36 Volt 2 x 275 Watt x 36Volt (72V) 3 x 330 Watt x 45Volt (90V)
PROBE
INSTALLATION Probe Installed
GUIDE: in Tank
6VP
4SD
4ST1
For detailed information on borehole range, refer to Pump Catalogues (4” & 6”)
• Stator replaceable
For detailed information on borehole motors, refer to Motor Catalogues (4” & 6”)
8 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
DC-AC
INVE RTER
is the next level solution for equipping of new or converting of existing boreholes that is capable of delivering flows
of 1000L/h to 22000L/h at total pump pressures of 2 to 30bar. The inverter works hand in hand with a 4” 220V 3PH
motor to accommodate standard NEMA 4” pump couplings for 0.75 to 5.5kW. The reason for the special 3 phase
motor voltage is the lowering of the DC input voltage to accommodate
smaller PV panel arrays.
If, for example your solution requires a 0.75kW motor, you would need at least 750W X 1.3 = 975W or rounded
up, 1000W to accommodate all losses and ensure maximum demand for a 6 hour daily cycle. The input voltage
requirement from the solar panel array is 220V to 370V DC (If a 380V 3PH motor had been used, the DC input voltage
requirement would be 420 to 710V DC +). A simple array of 4 x 250W/72V PV panels would deliver a perfect 1000W
and 288V DC.
caters for the high flow and pressure end of the market. This inverter supplies power to standard 380V 3PH motors
and the pumps in this range are able to deliver 10 to 80m³/h at total pressures of 2 to 45bar. The high DC input voltage
requirement is not a limitation, as the PV panel arrays are large enough to accommodate thus.
PARTS DESCRIPTIONS:
INSTALLATION
Installation Space
Power On Sequencing:
Disconnect Q2 firstly , and then wait at least 5 minuets until controller discharge (or digital LED and all indicators
extinguish ), then close Q1.Otherwise,will cause the damage of controller.
Notice:
(1) If there is no protection diode connected to the port of input-bus, it is forbidden to close photo voltaic cell switch
(“Q1”) and power grid switch (“Q2”) at the same time. Otherwise , will cause the damage of solar panels.
(2) When need to transform the power supply mode from power frequency tophotovoltaic cell; you only need to turn
off “Q1”firstly and then close “Q2”. Main circuit terminal functions are summarized according to the terminal to the
terminal symbols in the following table. Wire the terminal correctly for the desired purposes.
Remarks: when the actual water-level in the wells is higher than the horizontal line of high water-level ,“S1” and
“S2”will be connected to the “COM” as well as controller automatically will start the pump. On the
contrary, if the actual water-level is lower than the horizontal line of low water-level ,“S1” and “S2” will be
disconnected from “COM”as well as controller automatically stop the pump to prevent anhydrous idling.
Remarks :
when the actual water-level in the wells is higher than the horizontal line of high water-level “S1” and “S2” will be
connected to the “COM”as well as controller automatically start the pump. On the contrary, if the actual water-level
is lower than the horizontal line of low water-level ,“S1”and“S2”will be disconnected from “COM”as well as controller
automatically stop the pump to prevent
anhydrous idling.
Notice : if only use one detection signal of water-level in the wells , “S1”and “S2” must be connected together by conductor.
Remarks:
when the actual water-level in the reservoir is lower than the horizontal line of low water-level , “S3” and “S4” will
be disconnected from the “COM”as well as controller automatically start the pump.On the contrary, if the actual
water-level is higher than the horizontal line of high water-level ,“S3” and “S4” will be connected to “COM” as well as
controller automatically stop the pump to prevent water overflow.
Remarks :
when the actual water-level in the reservoir is lower than the horizontal line of low water-level
“S3” and “S4”will be disconnected from the “COM”as well as controller automatically start the
pump.On the contrary, if the actual water-level is higher than the horizontal line of high water-
level ,“S3”and“S4”will be connected to “COM”as well as controller automatically stop the pump to
prevent water overflow.
Remarks:
when the actual water-level in the reservoir is lower than the horizontal line of low water-level , “S3” and “S4” will be
disconnected from the “COM”as well as controller automatically start the pump. On the contrary, if the actual water-
level is higher than the horizontal line of high water-level ,“S3” and “S4” will
be connected to “COM” as well as controller automatically stop the pump to prevent water overflow.
Notice:
1 . If only use one detection signal of water-level in the reservoir , “S3”and “S4” must be connected together
by conductor.
2 . It is required to modify the wiring of floater switch’s NC or NO according to the parameter setting
(F0.12)
7.2.2 Power supply air switch trips off when power on:
• Inspect whether the input power supply is grounded or short circuit. Please solve the problem.
7.2.4 Controller displays normally when power on, but switch at the input side trips when running:
• Inspect whether the output side of controller is short circuit. If yes, ask for support.
• Inspect whether ground fault exists. If yes, solve it.
•If trip happens occasionally and the distance between motor and controller is too far, it is
recommended to install output AC reactor.
8.4 Warranty
For B503SLseries controller,our company provides 12 months warranty after the date of leave factory.
*Tips:
In fact, the application of the product is closely associated with solar sell and environment .only you
correctly preset the parameters of solar cell and additional use of the parameters(“F0.02 and F0.04” ) the highest
utilization efficiency can be achieved .
1.Firstly ,according to the solar sell panel to preset the parameters“ F0.05 and F0.06”. If you don’t want to
use the terminals“S1~S4”,“S1 and S2” must be connected to “COM”, otherwise it does not work normally.
2. Secondary, presetting the lower frequency limit “F0.02”of ensuring that the pump can work in this frequency.
3. After having the lower frequency limit ,you need to appropriately regulation the start-up voltage .Under the normal
condition of sun light ,if it starts and stops frequently ,you should properly increase the start-up voltage ,of course ,you
also can properly reduce the value of the lower frequency limit According to the environment as well as in combination
with proper these two parameters can use solar energy more efficiency.
Below is a guide line to determine the best angle for you panel.
The angle recommendation for various thermal regions are indicated and measured against the horizontal axis.
The lowest gradient is for winter installations. The highest is summer.
For remote installations, the midway point is recommended.
SU
M
M SU
ER M
AL M
LY ER
EA AL
RA LY
VE EA
WINT RA RA
ER GE VE
WINT RA
ER GE
72 CELL
MULTICRYSTALLINE MODULE
320 - 340W
POWER OUTPUT RANGE
17.5%
MAXIMUM EFFICIENCY
0~+5W
POSITIVE POWER TOLERANCE