0% found this document useful (0 votes)
63 views36 pages

Keli Pumps - Solar Products - Catalogue 2020

The Keli Pumps Solar Products Catalogue 2020 outlines various solar-powered pumping solutions, including peripheral vane booster pumps, borehole DC solar pumps, and borehole motors. The document provides technical specifications, features, and installation guidelines for each product, emphasizing their efficiency and suitability for non-corrosive water applications. It also includes information on solar panel requirements and system components for optimal performance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views36 pages

Keli Pumps - Solar Products - Catalogue 2020

The Keli Pumps Solar Products Catalogue 2020 outlines various solar-powered pumping solutions, including peripheral vane booster pumps, borehole DC solar pumps, and borehole motors. The document provides technical specifications, features, and installation guidelines for each product, emphasizing their efficiency and suitability for non-corrosive water applications. It also includes information on solar panel requirements and system components for optimal performance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

PRODUCT

CATALOGUE
SOLAR
PRODUCTS
2020
2 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
INDEX
PERIPHERAL VANE BOOSTER PUMP KIT DC SOLAR 4

3” BOREHOLE DC SOLAR PUMPS 6

4” & 6” SOLAR BOREHOLE PUMP RANGE 8


(4ST, 4SD, 6VP)

BOREHOLE MOTORS 9
4” 0.75KW - 5.5KW 220V 3 PHASE
4” 7.5KW - 380V 3PHASE
6” 7.5KW - 37KW 380V 3 PHASE

DC-AC INVERTER & MOTOR COMBINATION 10

SOLAR PANEL TECHNICAL DATA 33


SOLAR PANEL INSTALLATION GUIDE 33
SOLAR PANEL 34

This document contains hyperlinks. If you are using the electronic PDF copy you do not need to go through the entire
document to get to the required page, you can simply click on the required page on your index page. Click on the logo on
top to return to the Index page.

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 3


PERIPHERAL VANE DC SOLAR PUMP
3 LSQ B 2

MATERIAL:
Pump Casing: Cast Iron
Motor body: Aluminium
Impeller: Brass
Motor: 100% Copper

PRODUCT FEATURE:
Clean water DC Booster pump
Flow: 1-2 m³/h
DC Brushless Motor

WORKING CONDITIONS:
Non-corrosive water
Max temperature: 40°c
PH: 6.5 - 8.5

PUMP SOLAR PANEL INLET/


VOLTAGE MAX. FLOW MAX. HEAD MAX. SUCT WEIGHT
POWER REQUIREMENT OUTLET
MODEL IMPELLER

(V) (Watt) (WATT) (l/min) (m3/h) (m) (m) (inch) (kg)

LSQB2/26-
BRASS 36 275W 275W X 36V 33.33 2 26 6 1” 7.2
24/250

CONNECTION DIAGRAM
LSQB2/26-36/250
275 Watt x 36Volt
Booster Pump Set
Control Panel
2 x 12v Batteries
Regulator
- +
12v 12v
+ -

REGULATOR
• Use of the latest charging technologies combined with System can be connected to two
state of charge determination to enable optimal battery 12v deep cycle batteries (in series
maintenance and module power monitoring for up to 2880 = 24v) for night timeuse. This
Watt of connected power. will ensure that you have approx
• A large display informs the user about all operating modes 1 ½ hours continues duty without
with the aid of symbols. sunlight.

• The state of charge is represented, voltage and current is


displayed on LCD.

4 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


BOREHOLE DC SOLAR
PU M P S 3 L S S ( 3” )

MATERIAL 180W: MATERIAL 250W - 750W:


• 304 Stainless Steel Casing • 304 Stainless Steel Casing
• 304 Stainless Steel Shaft • 304 Stainless Steel Shaft
• 304 Stainless Steel Coupling • 304 Stainless Steel Coupling
• Cast Iron/Nickel plated pump body • 304 Stainless Steel Pump body
• 304 Stainless Steel Submersible motor • 304 Stainless Steel Submersible motor
• Graphite bearings • Graphite bearings
• 100% Copper windings • 100% Copper windings
• Wear resistant rubber stator • Wear resistant rubber stator

PRODUCT FEATURE:
180W
• Compact structure with high efficiency, low noise and pollutant free.
• Speed controller for accommodating low yield boreholes.
• Soft start electrical control panel provides protection against under-voltage, over
voltage, over-pumping, overloading and provides waterless automatic recovery
• Easy installation, maintenance-free, safe and reliable.
• DC Brushless Motor:
Max Water Submersion Depth : 20m (180W) & 50m (250W - 750W)
Max Flow: 2m3/h
Max Head: 110m
• Probe for monitoring water level in borehole.
• Probe for monitoring water level in tank.

APPLICATION:
Suitable for installations in boreholes, wells, rivers, dams and tanks with minimum ID
Ø 80mm.
250W - 750W
WORKING CONDITIONS:
• Non-corrosive water with a volume ratio of sand content not exceeding 1% and
the particle size not exceeding 0.5mm.
• Max pumped liquid temperature: 40°C
• PH capability: 6.5 - 8.5

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 5


MOTOR
POWER MAX FLOW MAX HEAD OUTLET CABLE SIZE
MODEL VOLTAGE
(WATT) (m3/h) (m) (INCH) between inverter and motor
(V)
3LSS1.5/50-24/180 24 180 1.5 50 3/4” 3 CORE 2.5mm2
3LSS1.2/60-24/250 24 250 1.2 60 3/4” 3 CORE 2.5mm2
3LSS1.2/85-24/350 24 350 1.2 85 3/4” 3 CORE 2.5mm2
3LSS2/110-72/750 72 750 2 110 3/4” 3 CORE 2.5mm2

*Note: For distance between PV Panels and Inverter, do not exceed 3 meters (cable length) when using 2.5mm2 cable.

POWER HEAD (M) SOLAR PANELS


MODEL
kW HP Flow 0 10 20 30 40 50 60 70 80 90 100 110 VOLTAGE POWER TOTAL

3LSS1.5/50- l/min 25 20 17 14 11 1.66 - - - - - -


0.18 0.24 36 1 x 275 36V x 275W
24/180 m3/h 1.5 1.2 1.02 0.84 0.66 0.1 - - - - - -

3LSS1.2/60- l/min 20.33 20 18.33 15.33 12.66 8.66 1.66 - - - - -


0.25 0.3 36 1 x 275 48V X 275W
24/250 m3/h 1.22 1.2 1.1 0.92 0.76 0.52 0.1 - - - - -

3LSS1.2/85- l/min 20.33 18.33 16.66 14.16 11.66 8.33 5 3.33 1.66 - - -
0.35 0.47 36 2 x 275 36V X 550W
24/350 m3/h 1.2 1.1 1.0 0.85 0.7 0.5 0.3 0.2 0.1 - - -

l/min 33.33 33.33 31.33 27.83 24.33 20.83 18.33 14 12 7.5 5 1.66
3LSS2/110-72/750 0.75 1 45 3 x 330 45V X 990W
m3/h 2.0 2.0 1.88 1.67 1.46 1.25 1.1 0.84 0.72 0.45 0.3 0.1

3LSS1.5/50-36/180 3LSS1.2/60-36/250 3 L S S 1 . 2 / 8 5 - 3 6 / 3 5 0 LSS1.2 3LSS2/110-45/750

275 Watt x 36 Volt 275 Watt x 36 Volt 2 x 275 Watt x 36Volt (72V) 3 x 330 Watt x 45Volt (90V)

PROBE
INSTALLATION Probe Installed
GUIDE: in Tank

Hang the probe inside


the tank and secure the
cable to the tank. Ensure
Probe Installed that the probe is hanging
in Borehole verticaly from probe
cable entry. This will
Secure the probe ensure that the pump
to the side of the switches on in the case
pump or pipe. This of low water in tank.
will ensure that the
pump will switch off
in case of low water
level in borehole.

6 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


SOLAR BOREHOLE PUMP
PERFO R M ANC E R ANG E S

6VP
4SD
4ST1

For detailed information on borehole range, refer to Pump Catalogues (4” & 6”)

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 7


BOREHOLE MOTORS
4” & 6”

4” 220V 3PHASE MOTORS: Type Motor Power Running dimensions

• 220V 3 Phase Power: 0.75 to 5.5 kW 220V -3 Phase kW HP Amps


Length Weight
(mm) (kg)
• Speed: 2850rpm
• Voltage: 220V 3 phase 4SD-0.75 0.75 1.0 4.0 344 8.0
• Insulation class: B 4SD-1.5 1.5 2.0 8.6 424 11.7
• Protection grade: P 68 4SD-2.2 2.2 3.0 11.3 344 8.0
• Highest temperature of Iiquid: 35°C 4SD-4.0 4 5.5 18.0 698 23.7

• Maximum solid handling: 40g/m3 4SD-5.5 5.5 7.5 24 788 28

• Motor casing: Stainless steel


• Maximum diameter: Φ 95 mm
With sandproof cover/pressure balance membrane/mechanical
seal for high performance. Flange and coupling according
to NEMA standard.

4” 380V MOTOR: Type Motor Power dimensions


Three Phase Running
kW HP Length (mm) Weight (kg)
• Three phase power: 7.5kW 380V~/50HZ Amps
• Speed: 2850rpm 4SD - 7.5 7.5 10.0 17 908 34
• Voltage: 380 ~ 415V/50Hz
• Insulation class: B
• Protection grade: IP 68
• Highest temperature of Iiquid: 35°C
• Maximum solid handling: 40g/m3
• Motor casing: Stainless steel
• Maximum diameter: Φ 95 mm
With sandproof cover/pressure balance membrane/mechanical seal for high performance.
Flange and coupling according to NEMA standard.

6” 380V WATER FILLED MOTOR: Motor PWL PWL weight weight


Power C.I. S.S. (motor only) (incl packaging)
• Three phase power: 5.5 - 37kW
S.S. 304 Cast Iron S.S. 304 Cast Iron
• Winding wire: Polywrapped winding (kW) (HP) (mm) (mm)
(kg) (kg) (kg) (kg)
• Degree of protection: IP68
5.5 7.5 747 727 46.0 49.0 51.2 54.2
• Maximum water temperature: 35°C
7.5 10 777 757 50.0 54.0 54.2 57.8
• Maximum starts per hour: 10 - 30 depending on
9.3 12.5 803 787 53.0 59.0 56.8 63.0
kW size 11 15 847 827 61.0 63.0 64.8 66.6
• Allowable voltage variation: +6% - 10% 13 17.5 897 877 64.0 67.0 67.7 70.7
• Motor shaft: Stainless steel 15 20 937 917 70.0 71.0 74.6 75.2
• Stator shell: Stainless steel 18.5 25 992 972 76.0 80.0 79.8 83.5
• Maximum immersion depth: Unlimited 22 30 1067 1047 90.0 90.0 94.2 94.3
• Mounting: Vertical 26 35 1127 1107 94.0 97.0 98.0 101.
• Motor cable length: 3m/3 Core with 30 40 1247 1227 102.0 100.0 108.0 105.0
separate earthcable 37.5 50 1347 1347 127.5 125.5 133.5 130.5
and 4 Core
• Cooling flow: V=0.2 m/s
• Coolant: Clear water

• Stator replaceable

For detailed information on borehole motors, refer to Motor Catalogues (4” & 6”)
8 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
DC-AC
INVE RTER

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 9


VEGA DC~AC INVERTER
(220TO370V DC ~ 220V 3PHASE AC)

is the next level solution for equipping of new or converting of existing boreholes that is capable of delivering flows
of 1000L/h to 22000L/h at total pump pressures of 2 to 30bar. The inverter works hand in hand with a 4” 220V 3PH
motor to accommodate standard NEMA 4” pump couplings for 0.75 to 5.5kW. The reason for the special 3 phase
motor voltage is the lowering of the DC input voltage to accommodate
smaller PV panel arrays.

If, for example your solution requires a 0.75kW motor, you would need at least 750W X 1.3 = 975W or rounded
up, 1000W to accommodate all losses and ensure maximum demand for a 6 hour daily cycle. The input voltage
requirement from the solar panel array is 220V to 370V DC (If a 380V 3PH motor had been used, the DC input voltage
requirement would be 420 to 710V DC +). A simple array of 4 x 250W/72V PV panels would deliver a perfect 1000W
and 288V DC.

VEGA DC~AC INVERTER


(420TO720V DC~380V 3PHASE AC)

caters for the high flow and pressure end of the market. This inverter supplies power to standard 380V 3PH motors
and the pumps in this range are able to deliver 10 to 80m³/h at total pressures of 2 to 45bar. The high DC input voltage
requirement is not a limitation, as the PV panel arrays are large enough to accommodate thus.

10 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


SPECIFICATION

OUTPUT 3AC 380V


Maximum input DC voltage 800VDC
Recommended DC input voltage range 420~720VDC
Recommended input working voltage 540VDC
The number of Input port 1
Rated output voltage 3AC 380V
Output frequency range 0~600Hz
Cooling method Air cooling
This controller should be installed with
altitude of lower than 1000m.
Altitude It will be degraded when the altitude is higher
than 1000m. For details, rated output current
should be degraded 1% for every 100m
Standard CE

OUTPUT 3AC 220V


Maximum input DC voltage 410VDC
Recommended DC input voltage range 220~370VDC
Recommended input working voltage 305VDC
The number of Input port 1
Rated output voltage 3AC 220V
Output frequency range 0~600Hz
Cooling method Air cooling
This controller should be installed with
altitude of lower than 1000m.
Altitude It will be degraded when the altitude is higher
than 1000m. For details, rated output current
should be degraded 1% for every 100m
Standard CE

DESCRIPTION OF NAME PLATE

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 11


SELECTION GUIDE
Output 3AC 380V

RATED OUTPUT RATED INPUT RATED OUTPUT MOTOR POWER


MODEL NO. SIZE
POWER CURRENT CURRENT (KW)
Output 3AC 380V
B503SL-4010 7.5 20 17 7.5 D
B503SL-4015 11 26 25 11 D
B503SL-4020 15 35 32 15 D
B503SL-4025 18.5 38 37 18.5 E
B503SL-4030 22 46 45 22 E
B503SL-4040 30 62 60 30 E
B503SL-4050 37 76 75 37 F

Output 3AC 220V

RATED OUTPUT RATED INPUT RATED OUTPUT MOTOR POWER


MODEL NO. SIZE
POWER CURRENT CURRENT (KW)
Output 3AC 220V
B503SL-4001 0.75 5.0 4.5 0.75 B
B503SL-4002 1.5 7.7 7 1.5 B
B503SL-4003 2.2 11.0 10 2.2 B
B503SL-4005 4.0 17.0 16 3.7 C
B503SL-4007 5.5 21.0 20 5.5 C

PARTS DESCRIPTIONS:

12 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


EXTERNAL DIMENSIONS

A (mm) B (mm) H (mm) W (mm) D (mm) Installation


Power (kW) Size
Installation Dimension External Dimension Hole (mm)
0.75 - 2.2 B 110.4 170.5 180 120 140 5.0
4 - 5.5 C 147.5 236 250 160 183 5.0
7.5 - 15 D 206 305.5 322 220 183 6.0
18.5 - 30 E 175 455 472 295 222 6.5
37 F 230 564.5 580 380 270 7.0

INSTALLATION
Installation Space

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 13


WIRING:
3.1 Schematic

3.2 Solar cell array power supply

14 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


3.3 Solar cell array and AC power supply

Power On Sequencing:
Disconnect Q2 firstly , and then wait at least 5 minuets until controller discharge (or digital LED and all indicators
extinguish ), then close Q1.Otherwise,will cause the damage of controller.
Notice:
(1) If there is no protection diode connected to the port of input-bus, it is forbidden to close photo voltaic cell switch
(“Q1”) and power grid switch (“Q2”) at the same time. Otherwise , will cause the damage of solar panels.
(2) When need to transform the power supply mode from power frequency tophotovoltaic cell; you only need to turn
off “Q1”firstly and then close “Q2”. Main circuit terminal functions are summarized according to the terminal to the
terminal symbols in the following table. Wire the terminal correctly for the desired purposes.

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 15


SPECIFICATIONS OF BREAKER, CABLE:

16 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


3.5 The wiring of water-level automatic control
3.5.1 The wiring to prevent pump from anhydrous idling

3.5.1.1 The wiring for floater water-level switch connected by cable


The common port ,which using floater water-level switch connected by cable, is fed to the terminal “COM” of B503
SL controller . And then ,select NO (Normally Open )and connect to “S1” (S1and S2 connected together ). If the NC
was connected to “S1”, the parameter “F0.12 ”should be set as follow: S1=1,S2=1.

Remarks: when the actual water-level in the wells is higher than the horizontal line of high water-level ,“S1” and
“S2”will be connected to the “COM” as well as controller automatically will start the pump. On the
contrary, if the actual water-level is lower than the horizontal line of low water-level ,“S1” and “S2” will be
disconnected from “COM”as well as controller automatically stop the pump to prevent anhydrous idling.

3.5.1.2 The wiring for floater water-level switch connected by rod


The floater water-level switch connected by rod is the normally open contact to output and its common wire is
connected to the terminal “COM”of B503SL controller.At the same time ,the low level-water wire is
connected to the terminal “S1” of B503SL controller and the high water-level wire is connected the terminal “S2” .If
the NC was selected,the parameter F0.12 should be set as follow: S1=1,S2=1.

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 17


Remarks:
when the actual water-level in the wells is higher than the horizontal line of high water-level ,“S1”and “S2” will be
connected to the “COM”as well as controller automatically start the pump .On the contrary, if the actual water-level
is lower than the horizontal line of low water-level ,“S1”and“S2”will be disconnected from“COM”as well as controller
automatically stop the pump to prevent anhydrous idling.

3.5.1.3 The wiring for water-level sensors


There are three signal leads as given (left image)for detecting water-level. The shortest signal line is 1,which is
corresponding to the horizontal line of high water-level ,is connected to the terminal “S2”of controller. The signal line 2
that is corresponding to the horizontal line of low water- level need to be connected to the terminal “S1” . The longest
line is 3 ,which is corresponding to the common port is connected to the terminal “COM”of controller.

Remarks :
when the actual water-level in the wells is higher than the horizontal line of high water-level “S1” and “S2” will be
connected to the “COM”as well as controller automatically start the pump. On the contrary, if the actual water-level
is lower than the horizontal line of low water-level ,“S1”and“S2”will be disconnected from “COM”as well as controller
automatically stop the pump to prevent
anhydrous idling.

Notice : if only use one detection signal of water-level in the wells , “S1”and “S2” must be connected together by conductor.

3.5.2 The wiring of reservoir

3.5.2.1 The wiring for floater water-level switch connected by cable


The common port ,which using floater water-level switch connected by cable ,,is fed to the terminal “COM” of B503 SL
controller . And then ,select NC and connect to“S3”(“S3”and “S4” connected together ). If the NO was connected to
“S3”, the parameter “F0.12 ”should be set as follow: S3=1,S4=1.

18 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


Remarks:
when the actual water-level in the reservoir is lower than the horizontal line of low water-level , “S3” and “S4” will
be disconnected from the “COM”as well as controller automatically start the pump .On the contrary, if the actual
water-level is higher than the horizontal line of high water-level ,“S3” and “S4” will be connected to “COM” as well as
controller automatically stop the pump to prevent water overflow.

3.5.2.2 the wiring for floater water-level switch connected by rod


The floater water-level switch connected by rod is the normally open contact to output and its common wire is
connected to the terminal “COM”of B503SL controller.At the same time ,the low level-water wire is
connected to the terminal “S3” of B503SL controller and the high water-level wire is connected the terminal “S4” .If
the NC was selected,the parameter F0.12 should be set as follow: S3=1,S4=1.

Remarks:
when the actual water-level in the reservoir is lower than the horizontal line of low water-level , “S3” and “S4” will
be disconnected from the “COM”as well as controller automatically start the pump.On the contrary, if the actual
water-level is higher than the horizontal line of high water-level ,“S3” and “S4” will be connected to “COM” as well as
controller automatically stop the pump to prevent water overflow.

3.5.2.3 the wiring for water-level sensors


There are three signal leads as given (left image)for detecting water-level. The shortest signal line is 1,which is
corresponding to the horizontal line of high water-level ,is connected to the terminal “S4”of controller. The signal
line 2 that is corresponding to the horizontal line of low waterlevel need to be connected to the
terminal “S3” . The longest line is 3 ,which is corresponding to the common port is connected to the terminal
“COM”of controller.

Remarks :
when the actual water-level in the reservoir is lower than the horizontal line of low water-level
“S3” and “S4”will be disconnected from the “COM”as well as controller automatically start the
pump.On the contrary, if the actual water-level is higher than the horizontal line of high water-
level ,“S3”and“S4”will be connected to “COM”as well as controller automatically stop the pump to
prevent water overflow.

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 19


3.5.3 the wiring for floater water-level switch mounted on a side
The floater water-level switch mounted on a side is the normally open contact to output and its common wire is
connected to the terminal “COM”of B503SL controller.At the same time ,the low level-water wire is
connected to the terminal “S3” of B503SL controller and the high water-level wire is connected the terminal “S4”.If the
NC was selected,the parameter F0.12 should be set as follow: S3=1,S4=1.

Remarks:
when the actual water-level in the reservoir is lower than the horizontal line of low water-level , “S3” and “S4” will be
disconnected from the “COM”as well as controller automatically start the pump. On the contrary, if the actual water-
level is higher than the horizontal line of high water-level ,“S3” and “S4” will
be connected to “COM” as well as controller automatically stop the pump to prevent water overflow.

Notice:
1 . If only use one detection signal of water-level in the reservoir , “S3”and “S4” must be connected together
by conductor.
2 . It is required to modify the wiring of floater switch’s NC or NO according to the parameter setting
(F0.12)

20 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


4.1 Keypad Description

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 21


22 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 23
24 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
5. Parameter Function

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 25


26 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 27
28 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
7.2 Common Faults and Solutions
Controller may have following faults or malfunctions during operation, please refer to the
following solutions:

7.2.1 No display after power on:


• Inspect whether the voltage of power supply is the same as the controller rated voltage or not
with multi-meter. If the power supply has problem, inspect and solve it.
• Check the CHARGE light. If the light is off, Please ask for support. If the light is on, the fault
maybe lies in the switching power supply. Please ask for support.

7.2.2 Power supply air switch trips off when power on:
• Inspect whether the input power supply is grounded or short circuit. Please solve the problem.

7.2.3 Motor doesn’t move after controller running:


• Inspect if there is balanced three-phase output among U, V, W. If yes, then motor could be
damaged, or mechanically locked. Please solve it.
• If the output is unbalanced or lost, the controller drive board or the output module may be
damaged, ask for support.

7.2.4 Controller displays normally when power on, but switch at the input side trips when running:
• Inspect whether the output side of controller is short circuit. If yes, ask for support.
• Inspect whether ground fault exists. If yes, solve it.
•If trip happens occasionally and the distance between motor and controller is too far, it is
recommended to install output AC reactor.

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 29


30 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1
8.2 Periodic Maintenance
Customer should check the drive every 3 months or 6 months according to the actual environment
8.2.1 Check whether the screws of control terminals are loose. If so, tighten them with a screwdriver;
8.2.2 Check whether the main circuit terminals are properly connected; whether the mains cables are overheated;
8.2.3 Check whether the power cables and control cables are damaged, check especially for any
wear on the cable tube;
8.2.4 Check whether the insulating tapes around the cable lugs are stripped;
8.2.5 Clean the dust on PCBs and air ducts with a vacuum cleaner;
8.2.6 For drives that have been stored for a long time, it must be powered on every 2 years. When supplying AC power
to the drive, use a voltage regulator to raise the input voltage to rated input voltage gradually. The drive should be
powered for 5 hours without load.
8.2.7 Before performing insulation tests, all main circuit input/output terminals should be short-
circuited with conductors. Then proceed insulation test to the ground. Insulation test of single
main circuit terminal to ground is forbidden; otherwise the drive might be damaged. Please
use a 500V Mega-Ohm-Meter.
8.2.8 Before the insulation test of the motor, disconnect the motor from the drive to avoid
damaging it.

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 31


8.3 Replacement of wearing parts
Fans and electrolytic capacitors are wearing part, please make periodic replacement to ensure long term, safety and
failure-free operation. The replacement periods are as follows:
> Fan: Must be replaced when using up to 20,000 hours;
> Electrolytic Capacitor: Must be replaced when using up to 30,000~40, 000 hours.

8.4 Warranty
For B503SLseries controller,our company provides 12 months warranty after the date of leave factory.

*Tips:
In fact, the application of the product is closely associated with solar sell and environment .only you
correctly preset the parameters of solar cell and additional use of the parameters(“F0.02 and F0.04” ) the highest
utilization efficiency can be achieved .

1.Firstly ,according to the solar sell panel to preset the parameters“ F0.05 and F0.06”. If you don’t want to
use the terminals“S1~S4”,“S1 and S2” must be connected to “COM”, otherwise it does not work normally.

2. Secondary, presetting the lower frequency limit “F0.02”of ensuring that the pump can work in this frequency.

3. After having the lower frequency limit ,you need to appropriately regulation the start-up voltage .Under the normal
condition of sun light ,if it starts and stops frequently ,you should properly increase the start-up voltage ,of course ,you
also can properly reduce the value of the lower frequency limit According to the environment as well as in combination
with proper these two parameters can use solar energy more efficiency.

32 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


It is recommended to install your solar panel to face North. This ensures the longest duration of sunlight exposure.

Below is a guide line to determine the best angle for you panel.
The angle recommendation for various thermal regions are indicated and measured against the horizontal axis.
The lowest gradient is for winter installations. The highest is summer.
For remote installations, the midway point is recommended.

NORTHERN SOUTH AFRICA SOUTHERN SOUTH AFRICA


INSTALLATION INSTALLATION

SU
M
M SU
ER M
AL M
LY ER
EA AL
RA LY
VE EA
WINT RA RA
ER GE VE
WINT RA
ER GE

26° 19.5° 13°


37° 31.5° 26°

OPTIMAL ANGLE FOR FIXED SOLAR PANELS


DEPENDING ON INSTALLATION POSITION

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 33


SOLAR PANELS

72 CELL
MULTICRYSTALLINE MODULE

320 - 340W
POWER OUTPUT RANGE

17.5%
MAXIMUM EFFICIENCY

0~+5W
POSITIVE POWER TOLERANCE

IDEAL FOR LARGE SCALE INSTALLATIONS


• High powerful footprint reduces installation time and BOS costs.
• 1000V UV/1000V IEC certified.

ONE OF THE INDUSTRY’S MOST TRUSTED MODELS


• Field proven performance.
• Strong, reliable supplier.

HIGHLY RELIABLE DUE TO STRINGENT QUALITY CONTROL


• Over 30 in-house tests (UV, TC, HF, and many more).
• In-house testing goes well beyond certification requirements.
• PID resistant.
• 100% EL double inspection.

CERTIFIED TO WITHSTAND THE MOST CHALLENGING


ENVIRONMENTAL CONDITIONS
• 2400 Pa wind load.
• 5400 Pa snow load.
• 35mm hail stones at 97km/h.

34 KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1


DC-AC
INVE RTER

ELECTRICAL DATA (STC)


PEAK POWER WATTS-Pmax (WP)* 320 325 330 335 340
POWER OUTPUT TOLERANCE Pmax (W) 0 ~ +5
MAXIMUM POWER VOLTAGE-Vmpp (V) 37.1 37.2 37.4 37.6 37.8
MAXIMUM POWER CURRENT-Impp (A) 8.63 8.73 8.83 8.91 8.99
OPEN CIRCUIT VOLTAGE-Voc (V) 45.5 45.6 45.8 46.0 46.2
SHORT CIRCUIT VOLTAGE-Isc (A) 9.15 9.19 9.28 9.35 9.42
MODULE EFFICIENCY ∩m (%) 16.5 16.7 17.0 17.2 17.5
STC: 1000W/m irradiance, 25°C cell temperature, AM 1.5.
2

*Measuring tolerance: ±3%

ELECTRICAL DATA (NOCT)


MAXIMUM POWER Pmax (Wp) 237 241 245 249 252
MAXIMUM POWER VOLATGE-Vmpp (V) 34.3 34.4 34.6 34.8 35.0
MAXIMUM POWER CURRENT-Impp (A) 6.92 7.00 7.08 7.14 7.21
OPEN CIRCUIT VOLTAGE-Voc (V) 42.1 42.2 42.4 42.6 42.8
SHORT CIRCUIT VOLTAGE-Isc (A) 7.39 7.42 7.49 7.55 7.60
NOCT 800W/m irradiance, Ambient temperature 20°C, Wind Speed 1m/s.
2

MECH ANICAL DATA


SOLAR CELLS Multicrystalline 156.75 x 156.75mm (6 inches)
CELL ORIENTATION 72 cells (6 x 12)
MODULE DIMENSIONS 1960 x 992 x 40mm (77.2 x 93.1 x 1.57 inches)
WEIGHT 22.5kg (49.6lb)
GLASS 3.2mm (0.13 inches), High Transmission, AR Coated
Tempered Glass
BACKSHEET White
FRAME Silver Anodized Aluminium Alloy
J-BOX IP 67 OR IP 68 Rated, 3 Bypass diodes
Photovoltaic Technology Cable 4.0mm²
CABLES
(0.006 inches²)
CONNECTOR TS4/QC4

TEMPERATURE RATINGS M AXIMUM RATINGS


NOCT (Nominal Operating Cell Operational Temperature
Temperature) 44°C (±2°C) -40~+85°C
Temperature Coefficient of Pmax -0.41%/°C 1000V DC (IEC)
Maximum System Voltage 1000V DC (UL)
Temperature Coefficient Voc -0.32%/°C
Temperature Coefficient Isc 0.05%/°C Max Series Fuse Rating 15A

KELI PUMPS | SOLAR PRODUCTS | CATALOGUE 2020 | V1 35

You might also like