0% found this document useful (0 votes)
75 views

q10

The document outlines the limited warranty and liability terms for a digital multimeter, which includes a one-year warranty from the date of purchase, excluding coverage for certain damages and misuse. It provides detailed safety information, operational instructions, and measurement guidelines for various functions of the multimeter. Additionally, it includes maintenance tips, specifications, and instructions for replacing batteries and fuses.

Uploaded by

Hạnh Bùi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views

q10

The document outlines the limited warranty and liability terms for a digital multimeter, which includes a one-year warranty from the date of purchase, excluding coverage for certain damages and misuse. It provides detailed safety information, operational instructions, and measurement guidelines for various functions of the multimeter. Additionally, it includes maintenance tips, specifications, and instructions for replacing batteries and fuses.

Uploaded by

Hạnh Bùi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

et? t.

PTSNe fis le me pbrveererngest tr


LIMITED WARRANTY
AND LIMITATION OF LIABILITY

Customers enjoy one-year warranty


from the date of purchase.

This warranty does not cover fuses,


disposable batteries, damage from
misuse accident, neglect, alteration,
contamination, or abnormal conditions
of operation or handling, — including
failures caused by use outside of the
product's specifications, or normal wear
and tear of mechanical components.
Table of Contents Page

INtrOGUCTION. 0.2... cece ec ceeeeeceeeeeeeeeeeeeeetaeeeeeeeeeeees 1


Safety: INMOMMAVON resccesssecwsseecworcserearerssessererseewes 1

Instrument: OVEWICW isvesccesremmnreemscres 3


UCD" Display sxervcererrsst tithe 3

FUNCTION, BULONS......::c.c0scsecceneecsssscsssesedsectens 5
Rotary: BUUONS tacts ectutnniwn eames 6
Input? Term ihalSseccssnversscsseseessreesnaeseseszersees 8

Measurements Instruction......0.....ccceceeeeeeeeeeeeee 9

Measure AC/DC Voltage............ccccecceeeeteeeees 9


Measure AC/DC Current..............cccseceeseeeeeeee 9
Measure Resistance ieiccsssssesscerneraceccn: 10
Test Diodes and Continuity............00.....000 10
Measure Capacitance................cccccceceeeeeeees 11

Measure Frequency and Duty Cycle............. 12

Measure Temperature.................:ccccccesseeeeeees 13

Test NCV...... 0... cceccec eee e cee eseeeeeeeeneenes 13


NEG tes tiecovccecorscorswexssucasseesosssaesnaresensiens 14
Square wave test...........ccececeeeeeeeeeesteeteeeees 14
Maintenance s.iscininnndeiwdeieninceieens 15
Clean the Produ Ctasscccecereere
eres ceeeessesise 15
Replace the Batteries.................
ce eeeeeeeeeeeee 15
Replace: the FUSS sisssccccecesssececcusseververserncecss 16
Specifications.............cccceeeeeeesesseeeceeeeeeeeeeeeeeeeees A7
General Specifications....................sssssccseee 17
Mechanical Specifications...............ccccceeeee 17
Environmental Specifications................... 17
Electrical Specifications cscscescecesmerncwn: 18
Introduction
This product is a 9999 counts true RMS auto-
ranging digital multimeter.
Safety Information
To avoid possible electrical shock, fire, or
personal injury, please read all safety information
before you use the product. Please use the
product only as_ specified, or the protection
supplied by the product can be compromised.
* Examine the case before you use the product.
Look for cracks or missing plastic. Carefully look
at the insulation around the terminals.
* The measurement must be made with correct
input terminals and functions and within the
allowable measuring range.
* Do not use the product around explosive gas,
vapor, or in damp or wet environments.
Keep fingers behind the finger guards on the
probes.
When the product has already been connected
to the line being measured, do NOT touch the
input terminal that is not in service.
Disconnect the test leads from the circuit before
changing the mode.
When the voltage to be measured exceeds 36V
DC or 25V AC, the operator shall be careful
enough to avoid electric shock.
Misuse of mode or range can lead to hazards,
be cautious. “ 9” will be shown on the display
when the input is out of range.
Low level of a battery will result in incorrect
readings. Change the batteries when battery
level is low. Do not make measurements when
the battery door is not properly placed.
Instrument Overview
LCD a ,

Auto range. The product selects


the range with the best resolution.
Manual range. The user selects
the range.
Capacitance test. (Farad)
| A {Relative mode.
S| Pt | Diode test.
© ))] Continuity test.
@) % Duty cycle test.
&) -ABAG Secondary measurements display.

Alternating current.
Direct current.
3
Frequency test. (Hertz)

nd |
Temperature test. (Celsius)
®

Temperature test. (Fahrenheit)

(4) | -t—Eo | Analog bar graph.


0D Resistance test. (Ohm)

A Current test. (Ampere)

@m| ¥ Voltage test. (Volt)

(®) |-ABBA Primary measurement display.


The product measures both
(>) |T-RMS sinusoidal and nonsinusoidal ac
waveforms accurately.
(20) (| Low battery. Replace batteries.
(DD) Eel Negative readings.

(22) HOLD Display freezes present reading.

@3 | V.F.C Frequency converter test.


Display maximum value.
Display minimum value.

nkMpm Measurement units.

4
Function Buttons
(2) (3)

()——»_ SELECT RANGE = wan


VAC

, NCV
Q
mv A

Short press to switch among functions.


Long press to enter in V.F.C function.
Short press to change range.
Push for more than 2 seconds to enter the
relative mode. The product will store the present
2) reading as a reference for subsequent readings.
The display is zeroed, and the stored reading is
subtracted from all subsequent readings. Long-
push again to exit the relative mode.

Press this button to switch MAX/MIN test. Long


(3)
press 2 second to quit MAX/MIN mode.

Push once to hold the current reading on the


display; push again to continue normal operation.
Long press beyond 2 seconds to turn on
flashlight ; long press again to turn off flashlight.

5
Rotary button

> NCV
Q
ave A

we

Vv mA

OFF BA

cE
9998 COUNTS
A

Turn off the product at this position.


* The product automatically powers
off after 15 minutes of inactivity.
* The built-in beeper beeps 5 times
1 minute before auto power off.
* To restart the product from auto
power off, press the SELECT
OFF button or turn the rotary switch
back to the OFF position and then
to a needed position.
* To disable the Auto Power Off
function, hold down the SELECT
button when turning on_ the
product, you will hear five beeps if
you have successfully disabled
the function.
6
AC voltage <750V
VEC DC voltage <1000V
Frequency 210V, 1~100KHz
Duty cycle: 1%~99%
V.F.C

AC voltage <99.99mV
DC voltage <99.99mV
Frequency $10V, 1~10MHz
mv @
Duty cycle: 1%~99%
Temperature: -20~1000° C (-4~1832)°F

Resistance: <99.99MQ
Continuity: beeper will beep when resistance
less than 50 Q
a Diode test. Displays [JLabove 3V
Capacitance: <9.999mF

NCV NCV
Square wave:
50Hz/100Hz/200Hz/300Hz/400Hz/
500Hz/600Hz/700Hz/800Hz/900Hz/
1000Hz/2000Hz/3000HzZ/4000Hz/
5000Hz

DC current: S99. 99mA.


mA AC current: S99. 99mA.

DC current: <999.9RA
HA AC current: <999.9HA

A DC current: <9. 999A


AC current: <9. 999A
Input Terminals

ag
mmx COM VQHz4t

Input terminal for AC/DC current


measurements to 9.999A.

Input terminal for AC/DC current


u A/mA
measurements to 99.99mA.

Common (return) terminal for all


COM
measurements.

Input terminal for the measurements of:


. Diode
ANOaRWDND=

. Continuity
. Square wave
Oe
VOQHz4+ . Temperature
. AC/DC voltage
. Resistance
. Frequency
. Capacitance

8
Measurements Instruction
Measure AC/DC Voltage
1. Connect the black test lead to the COM Terminal
and the red lead to the %i%! Terminal.
. TO measure voltage under 99.99mV, turn the
rotary to ww .TO measure voltage higher than
99.99mV, turn the rotary to ¥ , press
SELECT to turn to AC voltage test mode.
. Touch the probes to the correct test points of
the circuit to measure the voltage.
4. Read the measured voltage on the screen.

*Do not measure voltage that exceeds the extremes


as indicated in the Specifications.
*Do not touch high voltage circuit during measurements.

Measure AC/DC Current


1: Connect the black test lead to the COM Terminal
and the red lead to the A or HA /mA Terminal
(choose based on the value of the current to be
measured);
2 Tum the rotaryto «a, ™ Ora ;
3. Break the circuit path to be measured,
connect the test leads across the break and
apply power;
4. Read the measured current on the display.
9
*Do not measure current that exceeds the extremes
as indicated in the Specifications.
*Use the AmA Terminal when you are measuring an
unknown current. Then switch to the pA Terminal
if necessary.
*Do not input voltage at this setting.
Measure Resistance ‘
1. Connect the black test lead to the COM Terminal
and the test lead to the yo! Terminal;
2. Turn the rotary to », press “SELECT” to the
Resistance Mode. The screen will show “ 9”:
3. Touch the probes to the desired test points of
the circuit to measure the resistance;
4. Read the measured resistance on the display.
*Disconnect circuit power and discharge all
capacitors before you test resistance.
*Do not input voltage at this setting.

Test Diodes and Continuity


1. Connect the black test lead to the COM Terminal and ,
the red lead to the 7333! Terminal;
2. Turn the rotary to “> > ‘Press “SELECT” to the
continuity Mode; ‘
3. To test continuity, touch the probes to the desired
test points of the circuit. The built-in beeper will
beep when there is a short circuit;
10
To test diodes, connect the red probe to the anode
side and the black probe to the cathode side of
the diode being tested. Then read the forward bias
voltage value on the display. If the polarity of the
test leads is reversed with diode polarity or the
diode is broken, the display reading shows “OL”.

*Do not input voltage at this setting.


*Disconnect circuit power and discharge all
capacitors before you test diode.

Measure Capacitance
fi. Connect the black test lead to the COM Terminal and
the red lead to the ai! Terminal;
. Turnthe rotary to *) , press “SELECT” to the
capacitance Mode;
. Connect the red probe to the anode side and the
black probe to the cathode side of the diode being
tested;
4. Read the measured capacitance value on the
display once the reading is stabilized.

*Disconnect circuit power and discharge all


capacitors before you test diode.

11
Measure Frequency and Duty Cycle
1. Connect the black test lead to the COM Terminal and
the red lead to the ¥3i* Terminal;
2. Turn the rotary switch to “* , press SELECT
to frequency test function (210V , 1~100KHZz); or
turn the rotary switch to . 4g , press SELECT
to frequency test function ($10V , 1~5MHz);
3. If the frequency between 100kHz and 5MHz,
press SELECT to enter AC mV position. Touch
the probes to the desired test points, now the vice
display will show frequency; Then press the
SELECT again, the main display will show
frequency and vice display will show duty cycle.

12
Measure Temperature
1. Connect the black test lead to the COM Terminal
and the red lead tothe ¥3%% Terminal;
2. Turn the rotary to mv press “SELECT” to
the temperature Mode; Now the main display
will show Celsius and the vice display will
show Fahrenheit;
3. Touch the probes to the desired test points;
4. Read the measured temperature on the display.

*Do not input voltage at this setting.

Test NCV
1. Turn the rotary to NCV position, press “SELECT”
to the temperature Mode;
2. Hold the product and move it around, the built-in
beeper will beep when the inner sensor detects
AC voltage nearby. The stronger the voltage
is, the quicker the beeper beeps.

13
Measure V.F.C

1. Connect the black test lead to the COM Terminal and


the redlead tothe {ait Terminal;
2. Turn the rotary to {| ,longpress ‘to enter
V.F.C mode, the screen will show voltage when put
the test leads at the correct circuit.

Measure square wave

1. Connect the black test lead to the COM Terminal and

the redlead tothe %3! Terminal;


. Turn the rotary switch to sis , and the default

output frequency is 50Hz. To change the output

frequency, press the SEL button.

. Touch the probes to the desired test points.

*Do not input voltage at this setting.

14
Maintenance
Beyond replacing batteries and fuses, do not
attempt to repair or service the product unless you
are qualified to do so and have the relevant
calibration, performance test, and_ service
instructions.

Clean the Product


Wipe the product with a damp cloth and mild
detergent. Do not use abrasives or solvents. Dirt
or moisture in the terminals can affect readings.
*Remove the input signals before you clean the
product.

Replace the Batteries


When ‘A ” is shown on the display, batteries shall
be replaced as below:
1. Remove the test leads and turn off the product
before replacing the batteries.

15
Loosen the screw on the battery door and
remove the battery door.
Replace the used batteries with new batteries
of the same type.
Place the battery door back and fasten the
screw.

Replace the Fuses


When a fuse is blown or do not work properly, it
shall be replaced as below:
A. Remove the test leads and turn off the product
before replacing the fuse.
Loosen the four screws on the back cover and
the screw on the battery door, then remove the
battery door and the back cover.
Replace the fuse with a new fuse of the same
type.
Place the back cover and the battery door
back and fasten the screws.

16
Specifications

General Specifications
Display (LCD) 9999 Counts
Ranging Auto/Manual
Material ABS+TPE
Update Rate 3 Times/Second
Ture RMS Vv
Data Hold Vv
Backlight Vv
Low Battery Indication Vv
Auto Power Off Vv

Mechanical Specifications
Dimension 147*76*37mm
Weight 191g (without batteries)
Battery Type 1.5V AAA Battery * 3
Warranty One year

Environmental Specifications
. Temperature 0~40°C
Operating =
Humidity <75%
Temperature -20~60°C
Storage a
Humidity <80%

17
Electrical Specifications

Function Range Resolution | Accuracy

999.9mV 0.1mV

DC Voltage 9.999V 0.001V

(V) 99.99V 0.01V


+(0.5%+3)
999.9V 0.1V

DC Voltage 9.999mV 0.001mV

(MV) | 99.99mv__| 0.01mv


999.9mV 0.1mV

AC Voltage 9.999V 0.001V

(V) 99.99V 0.01V


+(1.0%+3)
750.0V 0.1V

AC Voltage 9.999mV 0.001mV

(mV) | 99.99mv | 0.01mv


*Frequency response of ACV: 40Hz-1kHz

18
Function Range Resolution | Accuracy

DC Current | 9-999A 0.001A


(A/mA) | .999.9mA | 0.1mA
99.99mA 0.01mA
+(1.0%+3)
DC Current | 9-999MA | 0.001mA

(HA/mA) | 99.9918 | 0.01uA


999.9yA 0.1pA

AC Current | 9-999A 0.001A


(A/mA) | 999.9mA_ | 0.1mA
99.99mA 0.01mA
+(1.2%+3)
AC Current |9:-999MA | 0.001mA
(wA/mA) | 99.99uA | 0.01pA
999.9uA | 0.1pA
Frequency response of AC Current: 40Hz-1kHz

19
Function Range Resolution | Accuracy

99.990 0.010 +(1.0%+3)

999.90 0.10

9.999kQ 0.001kQ
+(0.5%+3)
Resistance | 99.99kQ 0.01kQ

999.9kO 0.1kQ
9.999MQ | 0.001MQ +(1.5%+3)

99.99MQ_ | 0.01MQ +(3.0%+5)

9.999nF 0.001nF +(5.0%+20)

99.99nF 0.01nF

999.9nF 0.1nF

Capacitance | 9.999uF 0.001 pF +(2.0%+5)

99.991F 0.01,F

999.9uF 0.1 pF

9.999mF | 0.001mF +(5.0%+5)


Function Range Resolution | Accuracy

9.999Hz 0.001Hz

99.99Hz 0.01Hz
Frequency
(Measures 999.9Hz 0.1Hz
only to
100kHz 9.999kHz 0.001kHz | ++(0.1%+2)
9

under the | 99.99kHz 0.01kHz


ACV setting)
999.9kHz 0.1kHz

5.000MHz 0.001MHz

Duty Cycle | 1%~99% 0.1% +(0.1%+2)

(-20~1000)°C | 1°C
Temperature +(2.5%+5 )
(-4~1832) °F 1°F

Diode Vv

Continuity Vv

NCV Vv

Square wave Vv

N:E:C Vv
2A

You might also like