0% found this document useful (0 votes)
21 views1 page

S24009 - 213 - Revised Schedule of Footings & Columns

The document provides detailed specifications for the design and reinforcement of columns and footings for a proposed residential building, including dimensions, materials, and construction notes. It outlines the types of footings, reinforcement schedules, and general notes regarding concrete grades and steel specifications. The drawing is copyrighted and should not be reproduced without consent, and it emphasizes the importance of correlating with architectural and service drawings.

Uploaded by

mohdrayhan9786
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views1 page

S24009 - 213 - Revised Schedule of Footings & Columns

The document provides detailed specifications for the design and reinforcement of columns and footings for a proposed residential building, including dimensions, materials, and construction notes. It outlines the types of footings, reinforcement schedules, and general notes regarding concrete grades and steel specifications. The drawing is copyrighted and should not be reproduced without consent, and it emphasizes the importance of correlating with architectural and service drawings.

Uploaded by

mohdrayhan9786
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

COLUMN COLUMN

(As per design)


(As per design)
SCHEDULE OF COLUMNS
COLUMN BARS COLUMN BARS
(As per design) (As per design)

9" PLINTHBEAM PLINTHBEAM


(As per design) (As per design)
9" GND.LVL. GND.LVL. GND.LVL. GND.LVL.
10-T16 9"
8-T16 PEDESTAL

UPTO HARD MOORUM-MINIMUM 5'-0"


STIRRUPS

UPTO HARD MOORUM-MINIMUM 5'-0"


( 3' Height )
(As per design)
21"
6-T16 STIRRUPS

18"
PEDESTAL (As per design)

15"
(3'0" Height)

OR AS PER DESIGN
OR AS PER DESIGN
PEDESTAL
T8 @ 7" c/c T8 @ 7" c/c
T8 @ 7" c/c PEDESTAL TIES REINFORCEMENT
( 2 SETS ) ( 1 SET + PEDESTAL
( 2 SETS ) PEDESTAL
1 HOOK ) REINFORCEMENT
STIRRUPS (@ 3" c/c) STIRRUPS (@ 3" c/c)
C1 C2 C3
( c4 & c7 ) ( c2, c3, c5

D2
c9, c10, c11, c12 & c13) (c1, c6, c8 & c14)
M20

D1
Ld M20
3" Ld Ld

D1
3" 3"
SCHEDULE OF FOOTINGS

4"
4"
P.C.C. BED (M10) P.C.C. BED (M10)
PEDESTAL DETAILS CROSS SECTION OF SQUARE FOOTING
MARK TYPE SIZE D1 D2 REINFORCEMENT REMARKS CROSS SECTION OF SHOE FOOTING
SIZE MAIN BARS TIES (NOT TO SCALE) (NOT TO SCALE)
WIDTH WIDTH
F1 SQUARE 21" x 21" 8-T12
6'0" x 6'0" 20" -- T10 @ 5" c/c B/W T8 @ 7" c/c c4 & c7
FOOTING PCC BED
PCC BED
F2 SHOE
FOOTING
4'0" x 6'6" 9" 15" T10 @ 5" c/c B/W 18" x 18" 8-T10 T8 @ 7" c/c c2, c3, c5, c6 FOOTING
c8, c9 & c13
FOOTING PEDESTAL
F3 SQUARE 4'0" x 4'0" 16" -- T10 @ 5" c/c B/W 15" x 15" 6-T10 T8 @ 7" c/c c1, c12 & c14
FOOTING PEDESTAL
BARS
COMBINED T10 @ 5" c/c ( TOP B/W ) PEDESTAL FOOTING
F4 -- --- --- --- c10-c11
FOOTING 5'0" x 9'6" 20''

LENGTH
T10 @ 5" c/c ( BOT. B/W ) BARS
PEDESTAL

LENGTH
Note: BARS
NOTES : No Pedestal For Lift COLUMN COLUMN

1. GRADE OF CONCRETE : M20 - FOR ALL FOOTINGS, PEDESTALS & COLUMNS. Columns ( "c10, c11 & c13" ) COLUMN BARS
2. GRADE OF STEEL : Fe550 (TMT) COLUMN
3. MINIMUM CLEAR COVER TO MAIN REINF. : COLUMNS - 40mm BARS
FOOTINGS - 50mm
4. LAP LENGTH : COLUMNS - 47 Dia FOOTING BARS
5. ALL FOOTINGS & COLUMNS DESIGNED FOR "GROUND FLOOR + 4 UPPER FLOORS"
6. S.B.C. OF SOIL ASSUMED AS = 350 KN/SQ.M. THE SAME SHALL BE PLAN OF SQUARE FOOTING
CONFIRMED WITH SOIL TEST REPORT BEFORE EXECUTION. (NOT TO SCALE)
7. PROVIDE 4" THICK P.C.C BED OF CONCRETE GRADE M10.
8. CORRELATE THIS DRAWING WITH ARCHITECTURAL AND SERVICES DRAWINGS.
PLAN OF SHOE FOOTING
9. ANY DISCREPANCY TO BE BROUGHT TO CONSULTANTS ATTENTION. (NOT TO SCALE)

GENERAL NOTES: ARCHITECT & STRUCTURAL CONSULTANT: CLIENT: TITLE:


This drawing, the designs and details shown are the copyright
of GM A S S O C I AT E S . and shall not be copied or MR.NIZAMUDDIN
reproduced in any form without their written consent.
SHAIK MUNEER HUSSAIN SCHEDULE OF FOOTINGS & COLUMNS
CHIEF CONSULTANT
1. This Drawing is not to be scaled.
2. All dimensions shown are in Feets & Inches, and do not take into GM A S S O C I A T E S PROJECT:
DRAWN CHECKED APPROVED DATE SCALE
account applied finishes, unless specifically indicated otherwise.
3. Any omissions or discrepancies found shall be reported to the S T R U C T U R A L E N G I N E E R S MAN MUNEER MUNEER 12.02.2024 N.T.S
# 8-2-610/A/401, Fourth Floor, o +91 40 400 25 333 PROPOSED RESIDENTIAL
Architect / Engineer immediately.
4. Levels are given in Feets to two decimal places. Silver Tower Banjara, Road # 11, e [email protected] BUILDING @ KUKATPALLY JOB. No. DRAWING No. SHEET No. SIZE REV
5. This drawing is to be read in conjunction with the relevant Banjara Hills, Hyderabad - 34. e [email protected]
REV DATE DESCRIPTION DRWN CHKD APPR S24009 S24009 - 213 -- -- A3 1
architectural, services, specification and schedules.