S24009 - 213 - Revised Schedule of Footings & Columns
S24009 - 213 - Revised Schedule of Footings & Columns
18"
PEDESTAL (As per design)
15"
(3'0" Height)
OR AS PER DESIGN
OR AS PER DESIGN
PEDESTAL
T8 @ 7" c/c T8 @ 7" c/c
T8 @ 7" c/c PEDESTAL TIES REINFORCEMENT
( 2 SETS ) ( 1 SET + PEDESTAL
( 2 SETS ) PEDESTAL
1 HOOK ) REINFORCEMENT
STIRRUPS (@ 3" c/c) STIRRUPS (@ 3" c/c)
C1 C2 C3
( c4 & c7 ) ( c2, c3, c5
D2
c9, c10, c11, c12 & c13) (c1, c6, c8 & c14)
M20
D1
Ld M20
3" Ld Ld
D1
3" 3"
SCHEDULE OF FOOTINGS
4"
4"
P.C.C. BED (M10) P.C.C. BED (M10)
PEDESTAL DETAILS CROSS SECTION OF SQUARE FOOTING
MARK TYPE SIZE D1 D2 REINFORCEMENT REMARKS CROSS SECTION OF SHOE FOOTING
SIZE MAIN BARS TIES (NOT TO SCALE) (NOT TO SCALE)
WIDTH WIDTH
F1 SQUARE 21" x 21" 8-T12
6'0" x 6'0" 20" -- T10 @ 5" c/c B/W T8 @ 7" c/c c4 & c7
FOOTING PCC BED
PCC BED
F2 SHOE
FOOTING
4'0" x 6'6" 9" 15" T10 @ 5" c/c B/W 18" x 18" 8-T10 T8 @ 7" c/c c2, c3, c5, c6 FOOTING
c8, c9 & c13
FOOTING PEDESTAL
F3 SQUARE 4'0" x 4'0" 16" -- T10 @ 5" c/c B/W 15" x 15" 6-T10 T8 @ 7" c/c c1, c12 & c14
FOOTING PEDESTAL
BARS
COMBINED T10 @ 5" c/c ( TOP B/W ) PEDESTAL FOOTING
F4 -- --- --- --- c10-c11
FOOTING 5'0" x 9'6" 20''
LENGTH
T10 @ 5" c/c ( BOT. B/W ) BARS
PEDESTAL
LENGTH
Note: BARS
NOTES : No Pedestal For Lift COLUMN COLUMN
1. GRADE OF CONCRETE : M20 - FOR ALL FOOTINGS, PEDESTALS & COLUMNS. Columns ( "c10, c11 & c13" ) COLUMN BARS
2. GRADE OF STEEL : Fe550 (TMT) COLUMN
3. MINIMUM CLEAR COVER TO MAIN REINF. : COLUMNS - 40mm BARS
FOOTINGS - 50mm
4. LAP LENGTH : COLUMNS - 47 Dia FOOTING BARS
5. ALL FOOTINGS & COLUMNS DESIGNED FOR "GROUND FLOOR + 4 UPPER FLOORS"
6. S.B.C. OF SOIL ASSUMED AS = 350 KN/SQ.M. THE SAME SHALL BE PLAN OF SQUARE FOOTING
CONFIRMED WITH SOIL TEST REPORT BEFORE EXECUTION. (NOT TO SCALE)
7. PROVIDE 4" THICK P.C.C BED OF CONCRETE GRADE M10.
8. CORRELATE THIS DRAWING WITH ARCHITECTURAL AND SERVICES DRAWINGS.
PLAN OF SHOE FOOTING
9. ANY DISCREPANCY TO BE BROUGHT TO CONSULTANTS ATTENTION. (NOT TO SCALE)