DWG 2

The document outlines safety, health, and environmental information related to construction, maintenance, and demolition activities, emphasizing the need for structural supports to prevent instability. It includes mandatory instructions for contractors regarding dimensions, materials, and compliance with relevant standards. Additionally, it specifies the requirements for structural steelwork, concrete, and masonry to ensure safety and compliance with building regulations.

Uploaded by

sajeevan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views

DWG 2

The document outlines safety, health, and environmental information related to construction, maintenance, and demolition activities, emphasizing the need for structural supports to prevent instability. It includes mandatory instructions for contractors regarding dimensions, materials, and compliance with relevant standards. Additionally, it specifies the requirements for structural steelwork, concrete, and masonry to ensure safety and compliance with building regulations.

Uploaded by

sajeevan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SAFETY, HEALTH & ENVIRONMENTAl INFORMATION

In addition to the hazards/risks normally associated with the types of work detailed
on this drawing, note the following :

1 2 3 CONSTRUCTION
Structural instability during erection. Provide appropriate temporary supports or bracing.

Max.2810 Max.5620 MAINTENANCE / CLEANING


None identified.

DECOMMISSIONING / DEMOLITION

Catnic Heavy Duty Lintel Catnic Heavy Duty Lintel Structural instability during demolition. Provide appropriate temporary supports.

CN81C CN81C It is assumed that all works will be carried out by a competent contractor working, where
appropriate, to an approved method statement

A Important Notes: HEALTH & SAFETY RESIDUAL RISKS


- All dimensions shown are approximate. Mandatory Instructions
- Actual dimensions to be determined on the site by the Prohibitive Instruction
contractor prior to fabrication of steelwork. Warning
- Any deviation greater than 100mm shall be brought to NOTES

Doubled up rafters Doubled up rafters the attention of the structural engineer.


1. This drawing is to be read in conjunction with all relevant structural, architectural,
building services, cladding , roofing and other specialist supplier drawings and specification.
2. All DPM, DPC, Weather-proofing and finishes to be detailed by the project Architect. These
- Check stair headroom prior to fabrication of steelwork. drawings are to be used for building structure information only.
3. All dimensions are in millimeters unless noted otherwise.
Contact architect for any issues associated with stair 4.
5.
All levels are in meters unless noted otherwise.
All dimensions to be checked on site by the Contractor and any discrepancies
setting out and headroom. made known to the engineers prior to commencement of works.

- All steelwork except roof steelwork to be protected to STEELWORK

Max.4910
1 All Structural Steelwork including Connection design to be in accordance with EC3.
B4 achieve a minimum 30m minute fire rating. 2 The national structural steelwork specification (NSSS) for building construction 8th edition
applies to this project.
3 Technical requirements for execution of steel structures to be in accordance with
BS EN 1090-2, execution class, Exc2.
4 All fabricated steelwork delivered to site to be CE marked in compliance with BS EN 1090-1.

STRUCTURAL STEELWORK MEMBER SIZES KEY 5 All steelwork to be hot rolled section to BS EN 10025 or hot finished structural hollow sections

47x195 C24 Rafters @ 400 crs. 6.


to BS EN 10210
STEEL GRADES;
· All Structural Hollow Sections to be Grade S355 JOH

Column C1 = 203x203x52 UC - Grade S355 JO ·


·
All Hot rolled sections up to 16mm flange thickness = Grade S275
Hot rolled sections 16- 21mm flange thickness = Grade S275JR

Beam B1 = 203x203x52 UC - Grade S355 JO ·


·
Hot rolled sections above 21 mm flange thickness = Grade S275JO
All connecting plates to be Grade S275 Unless noted otherwise
7 Steelwork connection to be designed by the steelwork supplier using the connection design
Beam B2 = 203x203x46 UC - Grade S355 JO forces provided on the structural engineer's drawings. Please obtain project structural
engineer's for approval prior to fabrication.
Beam B3 = 152x152x30 UC - Grade S355 JO 8 In any instance all bolted connections to have minimum 4No. M16 Grade 8.8 bolts.
9 All Bolts to be Grade 8.8

New picture moment frame comprising Beam B4 = 203x102x23 UB - Grade S355 JO 10


11
All welds to be minimum 6mm continuous fillet weld.
All Moment Connections to have HSFG Bolts. Connection Plates, Beam Flange Mating

two columns,upper beams & foundation Beam B5 = 203x133x30 UB - Grade S355 JO Surfaces to be unpainted for all bolted moment connections.

The wall needs to be 215 thick solid wall to beam.Steel sizes:203x203 UC 52 (S275) CONCRETE

match the wall above. The architect to PS1 - 300x100x215 deep Concrete padstones 1 All reinforced concrete to be strength class C32/40 (RC 40) having a minimum

confirm the wall thickness


B PS2 - 215x100x215 deep concrete pad stones 2
cement/combination content of 340kg/m³ and a max W/C ratio of 0.50 and
Max aggregate size of 20mm.
Design Sulphate class is DS 4 (to be confirmed)
3 For special surface finishes refer to architects details.

before the work commences. Catnic Heavy Duty Lintel C1 B1 C1 4


5
All structural concrete to be cast on 50mm blinding concrete where appropriate.
Blinding concrete to be strength class C8/10 (designated mix GEN 1).
Catnic Heavy Duty Lintel

6 For details of cast-in elements such as gullies, ducts, pipes, manholes,conduits,


CN81C 7
light fitting and lightning protection etc. refer to the relevant services drawings.
Construction materials placed on slabs must be spread out so as not to exceed the
super-imposed dead load and imposed load allowed for in the design.

Max.2640
MASONRY
CN81C

1 All external brickwork to be freeze/thaw resistant (F2,S2 or F2,S1 to BS EN 771) where there
is a high risk of prolonged wetting and freezing. Bricks of compressive strength Class 20 (to
BS EN 771-2) are suitable for most applications. Bricks of strength Class 30 and declared as
freeze/thaw resistant (to BS EN 771-2) are recommended in areas of severe freeze/thaw
exposure or for use where bricks may be persistently wet (eg parapets, chimneys, sills and
below dpc).
2 Blocks should comply with BS EN 771 and be used in accordance with BS EN 1996-2, with a
compressive strength of 7.3 N/mm².
3 All mortar shall be designation (iii), (M4) 1:1:5½ cement: lime: sand, except below ground
where mortar designation (ii), (M6) 1:½:4 cement: lime: sand, is to be used.
4 Preliminary compressive strength tests shall be carried out on the mortar in accordance with
BS 5628: part 1: appendix a1.Regular testing of the mortar during construction shall be
carried out.

C 5 All cavity walls to have stainless steel wall ties at 900mm horizontal and 450mm vertical
centers and must embed at least 50mm in to each leaf.

47x195(C16) floor joists at 400 crs

Max3730
1.0 12.06.2024 Issued for Construction SU SS BK
Ver Date Description Of Change Drn Chk App

Structural Design Bureau


S
D D
Structural & Civil Engineering Consultants

B
E www.sdblimited.com

Max.300
Structural Design Bureau Limited
Suite 5, Park House, 1-4 Park Terrace, Worcester Park, Surrey KT4 7JZ
Tel: +44(0)208 240 9987
Catnic Heavy Duty Lintel Email: [email protected]
Key Plan

CN81C

Client Scale
Martin Kacmar 1:30
Project Name
5 Arundel Avenue, Morden SM4 4DR

High Level Ground Floor (1st Floor) Title

Proposed Rear & Side Extension


First Floor (High Level Ground Floor)

General Arrangement General Arrangement


Company
SDB LTD
Drawn By
SU
Location-Level-Sub series/System-Identifier
Chk/Approved
SS
Drawn Date
12.06.2024
Status
IFC
Version

SDB 1792-10-GA-S-001 1.0