Vemat Ie3 en x5 Final-1
Vemat Ie3 en x5 Final-1
al Purpose
3-phase
Induction Moto
Comply with the new efficiency classes
for low-voltage three-phase motors
IEC 60034-30 standard
and EU Regulation 640/2009, 4/2014
Ener
gy Efficient
Motors
series 3VTB
Product Catalogue
General Purpose 3-phase Induction Motors
02
General Purpose 3-phase Induction Motors
General Purpose 3-phase Induction Motors
Contents
Efficiency of motors
Ratings-tolerances
Standards
Insulation classification
Terminal box
Degree of protection
Mounting arrangements
Bearings
Housing, endshields
Ordering information
04
General Purpose 3-phase Induction Motors
INTRODUCTION
New efficiency classes for the low-voltage three-phase motors (IE = International Efficiency).
Along with the international discussion on energy efficiency a worldwide harmonized energy efficiency
standard classification system has been established for low-voltage three-phase asynchronous motors.
For many years low-voltage three-phase motors in the European Union have been sold in three efficiency classes
EFF3, EFF2 and EFF1. Aside from this, many different efficiency classification systems have been introduced and
well-proven in many countries all over the world.
This was the reason for the International Electrotechnical Commission IEC to develop and publish an energy
efficiency standard which replaces all previous national issues. In parallel IEC developed and issued a new
standard for determining motor efficiency. The new standard IEC 60034-30-1 defines and harmonizes worldwide
the efficiency classes IE1, IE2, IE3 and IE4 for low-voltage three-phase motors in the power range from 0.12 kW
to 1000 kW (2p=2, 4, 6, 8)
According to the Comission Regulation (EC) No 640/2009 (introduced in July 2009) including
Comission Regulation (EC) No 4/2014 the required efficiency class of general-purpose motors
with 2p=2, 4, 6 (introduced to the market in the future) will be as follows:
Electronic speed control is carried out using a frequency converter (VSD) that adjusts the
speed of the motor - and therefore the torque produced - based on the energy needed.
05
General Purpose 3-phase Induction Motors
EFFICIENCY OF MOTORS
The present catalogue describes the electric motors which belong to the efficiency class IE3 (Premium
Efficiency) and motors excluded from the Regulations (EC) 640/2009 and 4/2014 (motors with 2p = 8, 10, 12
and with rated output below 0.75kW and above 375kW).
94
Efficiency [%]
86
78
70
0,1 1 10 100 400
PN [kW]
The efficiency class system specified under IEC 60034-30-1 is valid for low voltage three phase
squirrel cage induction motors with the following specifications:
Motors with flanges, feet and/or shafts with mechanical dimensions different from IEC 60072-1
are also covered by this standard.
06
General Purpose 3-phase Induction Motors
RATINGS - TOLERANCES
Permissible deviations between real values and catalogue values according to the IEC 60034-1:
STANDARDS
The electric motors are manufactured according to the international standards:
The resulting efficiency values differ from those obtained under the previous
IE1
IEC 60034-2:1996 testing standard.
It must be noted that the efficiency values are only comparable if they are obtained
using the same measuring method.
IE2
EU Regulation 640/2009 and 4/2014 adapted on 6 January 2014
Commission Regulation 640/2009, adapted on 22 July 2009, specifies the
requirements regarding the ecodesign of electric motors and the use of electronic
speed control (VSD). IE3
All the motors are manufactured according to
Quality Assurance System consistent with ISO 9001.
ISO9001
IEC
The motors covered by the present catalogue comply with the regulations
and standards effective in other countries, consistent with IEC standards.
All the motors described in the present catalogue are provided with CE mark.
07
General Purpose 3-phase Induction Motors
INSULATION CLASSIFICATION
The insulation system of an electric motor is determined by a given insulation Symbols of thermal resistance classes
class on the basis of its thermal resistance. (permissible insulation temperatures
This thermal resistance should be guaranteed by the entire set of electric at 40°C ambient temperature)
insulating materials used in the motor insulating system.
Symbol Temperature [° C]
Thermal resistance classification is related to the temperature of the hotspot
in the insulation occurring during rated operating conditions of the electric
motor, allowing for the highest permissible rise in average temperature. A 105
This rise should be selected so that at the highest permissible ambient E 120
temperature, the temperature of the hotspot in insulation will not exceed the B 130
value assigned to a given thermal resistance class.
F 155
H 180
Ambient temperature
Insulation class F in an electric motor means that
at ambient temperature of 40°C the temperature
Maximal rise of the winding may be max. 105°C with the
temperature rise
additional temperature margin of 10°C
A Temperature margin (under specified measuring conditions in
40° 60° 5°
accordance with the IEC 60034-1 standard).
Insulation class
B
40° 75° 5°
Class F
The standard motors made by Vemat in their basic
40° 80° 10°
version have the insulation class F while the
temperature rise is for class B.
F This means longer life for motors.
40° 105° 10°
For special request we can deliver motors equipped
with insulation class H.
H
40° 125° 15° Strengthened insulation system gives possibility
to safe operation with frequency converters.
MOTOR FEET
Motors with frame size Ł 132 have screwed feet.
Motors with frame size > 132 up to 315 have screwed feet or feet integrated with the motor housing.
Motors with frame size from 355 have feet integrated with the motor housing.
TERMINAL BOX
The terminal boxes of low voltage motors have threaded inlet Low voltage high-power motors contain terminal boxes with
holes designed for mounting cable glands. cable gland seals.
The box contains a terminal board with marked terminals
making possible connection of supply cables. The circuits of thermal protection and anticondensation heaters
are connected to separate terminal boxes.
In addition, terminal boxes may be provided with additional
terminals connected to the ends of thermal protection or Inside the boxes there are special clamps used to ground the
anticondensation heater circuits and extra glands to connect supply cable armouring.
these circuits.
00 No protection
0 Not protected
Not protected 01 150 g Striking energy:
0 1 Protected against vertically 0.15 J
10 cm
falling drops of water
Protected against
solid bodies larger than 200 g
1 50 mm Protected against 02 Striking energy:
15 10 cm
2 15 vertically falling 0.20 J
drops of water up to 15°
Protected against
solid bodies 60 60
03 250 g Striking energy:
2 Protected against
larger than 0.37 J
12 mm 3 rain up to 60° 15 cm
250 g
Protected against Protected against 06 Striking energy:
5 deposition of dust 6 temporary 40 cm 1J
immersion
1.25 kg
All Vemat standard motors are manufactured with IP 55 degree of protection 08 Striking energy:
according to the standard in force (IEC 60034-5). The following table lists its 40 cm 5J
characteristics.
Each size 80 to 180 motor is equipped with seal rings (Simmerring or V-ring) 2.5 kg
on drive side and on non drive side. Labyrinth seals protect the motors from
size 200 and above. 09 40 cm
Striking energy:
10 J
The terminal box is sealed with a gasket.
5 kg
Motors with a higher degree of protection are 10
40 cm
Striking energy:
20 J
available on request.
09
General Purpose 3-phase Induction Motors
MOUNTING ARRANGEMENTS
Designation Designation
56 ÷ 315
IM 3001 IM B5 without 3VTB 315 M6B,C,D IM 3611 IM V18 56 ÷ 180
without VTB 315 M8C,D
10
General Purpose 3-phase Induction Motors
PERMISSIBLE LOADS ON THE SHAFT END
Frame Number Horizontal Vertical Frame Number Horizontal Vertical
size of poles operation operation size of poles operation operation
Fp Fp
FR X FR X
Fa2 Fa2
Xmax X0 Xmax X0
Fa1 Fa1
FR(x = 0) FR(x = max) Fp Fa1 Fa2 FR(x = 0) FR(x = max) Fp Fa1 Fa2
[kN] [kN] [kN] [kN]
VTB 56 2 0,20 0,16 0,04 0,03 0,05 3VTB 200 LA 2 2,91 2,44 2,24 1,72 2,92
VTB 56 4 0,25 0,20 0,05 0,04 0,06 3VTB 200 LB 2 2,85 2,39 2,23 1,67 2,93
VTB 56 6 0,25 0,20 0,06 0,05 0,07 3VTB 200 L 4 3,61 3,03 2,81 2,12 3,70
VTB 63 2 0,20 0,16 0,04 0,04 0,06 3VTB 200 LA 6 4,31 3,62 3,62 2,92 4,56
VTB 63 4 0,25 0,20 0,06 0,05 0,07 3VTB 200 LB 6 4,06 3,40 3,54 2,71 4,65
VTB 63 6 0,27 0,22 0,06 0,05 0,07 3VTB 225 S 4 4,18 3,40 3,19 2,42 4,16
VTB 63 8 0,27 0,22 0,07 0,06 0,08 3VTB 225 M 2 3,31 2,81 2,53 1,93 3,29
VTB 71 2 0,29 0,24 0,07 0,05 0,09 3VTB 225 M 4 3,97 3,23 3,13 2,26 4,24
VTB 71 4 0,36 0,30 0,09 0,07 0,11 3VTB 225 M 6 4,57 3,72 3,98 2,95 5,33
VTB 71 6 0,40 0,35 0,10 0,08 0,12 3VTB 250 M 2 4,09 3,39 3,11 2,33 4,13
VTB 71 8 0,40 0,35 0,11 0,09 0,13 3VTB 250 M 4 4,90 4,06 3,85 2,68 5,36
3VTB 80 2 0,33 0,27 0,09 0,06 0,12 3VTB 250 M 6 5,92 4,90 4,99 3,81 6,55
3VTB 80 4 0,44 0,37 0,12 0,09 0,15 3VTB 280 S 2 3,94 3,34 3,07 2,01 4,43
VTB 80 6 0,51 0,42 0,14 0,11 0,17 3VTB 280 S 4 6,69 5,67 5,01 3,65 6,77
VTB 80 8 0,51 0,42 0,17 0,15 0,20 3VTB 280 S 6 7,86 6,67 5,79 4,32 7,70
3VTB 90 2 0,68 0,44 0,68 0,35 0,38 3VTB 280 M 2 3,80 3,22 3,03 1,89 4,49
3VTB 90 4 0,78 0,44 0,78 0,35 0,38 3VTB 280 M 4 6,15 5,22 4,86 3,16 7,04
3VTB 90 6 0,96 0,44 0,96 0,35 0,38 3VTB 280 M 6 7,69 6,52 5,75 4,19 7,75
3VTB 100 2 0,88 0,46 0,90 0,28 0,40 3VTB 315 S 2 3,56 3,08 2,96 1,63 4,69
3VTB 100 4 1,06 0,46 0,98 0,38 0,40 3VTB 315 S 4 5,75 4,82 4,74 2,71 7,37
3VTB 100 6 1,20 0,46 1,10 0,38 0,40 3VTB 315 S 6 7,21 6,04 5,61 3,84 8,14
3VTB 112 2 1,00 0,48 1,00 0,40 0,45 3VTB 315 MA 2 3,07 2,65 2,82 1,23 4,89
3VTB 112 4 1,45 0,48 1,40 0,40 0,45 3VTB 315 MB 2 2,67 2,31 2,71 0,91 5,05
3VTB 112 6 1,62 0,48 1,60 0,40 0,45 3VTB 315 MA 4 5,40 4,52 4,64 2,41 7,53
3VTB 132 2 1,82 0,66 1,90 0,43 0,60 3VTB 315 MB 4 5,16 4,33 4,58 2,20 7,64
3VTB 132 4 2,10 0,66 2,20 0,45 0,60 3VTB 315 MA 6 6,75 5,66 5,48 3,22 8,40
3VTB 132 6 2,80 0,66 2,80 0,50 0,60 3VTB 315 MB 6 6,27 5,33 5,34 2,68 8,78
3VTB 160 2 2,22 0,98 2,30 0,92 0,95 3VTB 315 MC 2 2,84 2,48 2,71 0,63 5,37
3VTB 160 4 2,40 0,98 2,40 0,92 0,95 3VTB 315 MC 4 6,27 5,33 4,34 1,46 8,06
3VTB 160 6 2,85 1,10 2,90 0,98 1,00 3VTB 315 MC 6 7,57 6,44 5,08 1,87 9,23
3VTB 180 2 2,92 1,30 3,00 1,10 1,20 3VTB 315 MD 6 7,47 6,36 5,05 1,82 9,22
3VTB 180 4 3,60 1,30 3,60 1,10 1,30
3VTB 180 6 4,00 1,80 4,10 1,40 1,70
PERMISSIBLE LOADS ON THE SHAFT END for motors VTB (2p = 8 ÷ 12)
FR(x = 0) FR(x = max) Fp Fa1 Fa2 FR(x = 0) FR(x = max) Fp Fa1 Fa2
[kN] [kN] [kN] [kN]
VTB 200L8 8 5,10 4,20 4,10 3,40 5,00 VTB 280S8 8 8,30 6,90 6,60 5,20 8,50
VTB 200L10A 10 5,50 4,60 4,20 3,50 5,10 VTB 280S10 10 9,30 7,70 6,70 5,40 8,40
VTB 200L10B 10 5,50 4,50 4,10 3,40 5,10 VTB 280S12 12 9,80 8,10 7,00 5,70 8,70
VTB 200L12 12 5,90 4,90 4,40 3,70 5,40 VTB 280M8 8 8,00 6,60 6,50 4,90 8,60
VTB 225S8 8 5,90 4,70 4,70 3,90 5,70 VTB 280M10 10 8,80 7,30 6,50 5,20 8,20
VTB 225S10 10 6,50 5,10 4,70 4,00 5,60 VTB 280M12 12 9,20 7,60 6,80 5,00 9,30
VTB 225S12 12 6,70 5,30 4,80 4,20 6,00 VTB 315S8 8 8,40 7,00 7,00 5,00 9,60
VTB 225M8 8 5,70 4,60 4,60 3,70 5,80 VTB 315S10 10 9,30 7,70 7,60 5,60 10,20
VTB 225M10 10 6,30 4,90 5,70 4,40 7,40 VTB 315S12 12 9,80 8,10 8,00 5,90 10,80
VTB 225M12 12 6,70 5,30 4,90 3,90 6,20 VTB 315M8A 8 8,20 6,80 6,90 4,80 9,70
VTB 250M8 8 6,90 5,60 5,60 4,30 7,20 VTB 315M8B 8 7,70 6,40 6,80 4,30 10,00
VTB 250M10 10 7,50 6,20 5,70 4,40 7,40 VTB 315M10 10 8,40 7,00 7,30 4,80 10,70
VTB 250M12 12 8,10 6,70 6,10 4,80 7,80 VTB 315M12A 12 9,30 7,70 7,90 5,50 11,10
VTB 315M12B 12 9,10 7,60 7,80 5,30 11,20
11
General Purpose 3-phase Induction Motors
Mechanical Size Type of construction No. of poles, 2p D.E. bearing N.D.E. bearing
Horizontal mounting
Permissible radial forces Permissible axial forces
FX0 FXmax FA
Motor type Number of poles Length of shaft extension E(mm) kN kN kN
VTB 400
VTB 450 4÷8 on request
VTB 500
where: P - motor output [kW] where: FX0 - value of FR force acting on the beginning of the shaft end
DK - belt pulley diameter [m] FXMAX - value of FR force acting on the end of the shaft end
n - speed [rpm] E - lenght of the shaft end
k - belt tension factor:
for V-belts k=2,2
for flat belts k=3
12
General Purpose 3-phase Induction Motors
lubrication on the
rotation of the
cable outlets
protection of
Temperature
terminal box
the terminal
Position of
Number of
Number of
sensors in
protection
Degree of
terminals
bearings
Optional
Thermal
winding
Bearing
Glands
Frame
size
box
run
56 IP 55 top 6 1 180° M 20 on request no no
63 IP 55 top 6 1 180° M 20 on request no no
71 IP 55 top 6 1 180° M 20 on request no no
80 IP 55 top 6 1 180° M 20 on request no no
90 IP 55 top 6 2 180° M 20 on request no no
100 IP 55 top 6 2 180° M 20 on request no no
112 IP 55 top 6 2 180° M 25 on request no no
132 IP 55 top 6 2 180° M 25 on request no no
160 IP 55 top 6 2 180° M 40 on request on request on request
180 IP 55 top 6 2 180° M 40 on request on request on request
200 IP 55 top * 6 2 4 × 90° M 50 PTC yes on request
225 IP 55 top * 6 2 4 × 90° M 50 PTC yes on request
250 IP 55 top * 6 2 4 × 90° M 63 PTC yes on request
280 IP 55 top * 6 2 4 × 90° M 63 PTC yes on request
315 IP 55 top * 6 2 4 × 90° M 76 PTC yes on request
355ML IP 55 top 6 2 4 × 90° M 76 PTC Mark A yes on request
355H IP 55 top 6 2 4 × 90° M 90 Pt 100 yes Pt 100
400 IP 55 top 6 (bars) 3 180° 3×f55 Pt 100 yes Pt 100
450 IP 55 top 3 (bars) 3 180° 3×f55 Pt 100 yes Pt 100
500 IP 55 top 3 (bars) 3 180° 3×f55 Pt 100 yes Pt 100
* terminal box on right side for VTB 200-315 motors series
BEARINGS
Frame Number Bearings Frame Type of No. of D.E. N.D.E.
The bearings in basic version of motors for horizontal and verical duty,
version of motors
3VTB 90 2÷6 6205 2Z C3
3VTB 355 H IM1001 (B3) 2 6217 C3 6217 C3
3VTB 100 2÷6 6206 2Z C3
3VTB 112 2÷6 6306 2Z C3 3VTB 355 H IM2001 (B35) 4÷6 6322 C3 6322 C3
3VTB 132 2÷6 6308 2Z C3
3VTB 355 H IM3011 (V1) 4÷6 6322 C3 6322 C3
3VTB 160 2÷6 6309 2Z C3
3VTB 180 2÷6 6311 2Z C3
3VTB 200 2÷6 6312 C3 Frame Type of No. of D.E. N.D.E.
excluding 3VTB 315 with 2p=2.
13
General Purpose 3-phase Induction Motors
In motors series VTB of frame size 80, 90 and 100mm: on request end shields may be made of cast iron.
In motors series 3VTB of frame size 80 and 90mm: on request end shields may be made of cast iron.
In motors of frame size 132: feet may be integrated with housing.
Motor housing
aluminium
aluminium cast iron
cast iron
14
General Purpose 3-phase Induction Motors
3VTB 315 M 4 B
VTB 315 M 8 B
A=Lower power
B=Higher power
C,D=Increased Power
No. of poles
(Speed)
Frame
length
L=long
M=medium
S=short
Shaft h
(in B3)
ORDERING INFORMATION
Orders for motors should specify: When ordering high-power or special purpose motors one
should also indicate:
and information concerning additional accessories e.g. full designation of the motor type including its serial
number (provided on the nameplate) or catalogue number,
degree of protection,
thermal protection,
mounting arrangement,
anticondensation heaters,
name of part,
vibration sensors,
number of pieces.
etc.
15
General Purpose 3-phase Induction Motors
rotor current
Breakdown
rotor torque
Moment of
Efficiency
Locked
current
Weight
Locked
output
torque
torque
Power
Inertia
speed
Rated
Rated
Rated
factor
Type
Item
load
Full
PN nN TN hN [%] cos jN IN at rated voltage [A] TL/TN IL/IN TB/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] 230V 380V 400V [-] [-] [-] [kgm2] [kg]
16
General Purpose 3-phase Induction Motors
Totally Enclosed Motors IP 55
rotor current
Breakdown
rotor torque
Moment of
Efficiency
Locked
current
Weight
Locked
output
torque
torque
Power
Inertia
speed
Rated
Rated
Rated
factor
Type
Item
load
Full
PN nN TN hN [%] cos jN IN at rated voltage [A] TL/TN IL/IN TB/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] 230V 380V 400V [-] [-] [-] [kgm2] [kg]
17
General Purpose 3-phase Induction Motors
rotor current
rotor torque
Breakdown
Moment of
Efficiency
Locked
current
Weight
Locked
output
torque
torque
Inertia
Power
speed
Rated
Rated
Rated
factor
Type
Item
load
Full
PN nN TN hN [%] cos jN IN at rated voltage [A] TL/TN IL/IN TB/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] 230V 380V 400V [-] [-] [-] [kgm2] [kg]
81 VTB 56-6B 0,06 0,08 870 0,64 44 46 50 0,65 1,1 0,65 0,65 1,3 1,8 1,5 0,00019 2,8
82 VTB 63-6A 0,09 0,12 820 1,05 26 32 40 0,75 0,8 0,45 0,45 1,15 1,9 1,3 0,00024 3,5
83 VTB 63-6B 0,12 0,17 870 1,30 38 44 50 0,65 1,15 0,65 0,65 1,3 1,8 1,1 0,00031 4,1
84 VTB 71-6A 0,18 0,25 890 1,93 47 54 57 0,68 1,3 0,75 0,75 1,9 2,6 1,9 0,00074 4,8
85 VTB 71-6B 0,25 0,33 860 2,78 45 52 55 0,79 1,75 1,0 1,0 1,6 2,0 1,6 0,00095 5,6
86 VTB 80-6A 0,37 0,50 910 3,88 61 63 64 0,65 2,4 1,4 1,4 2,0 3,0 2,1 0,00169 7,4
87 VTB 80-6B 0,55 0,75 900 5,84 62 65 67 0,70 3,1 1,8 1,8 1,9 2,7 2,0 0,00207 8,7
88 3VTB 90S6 0,75 1 940 7,6 77,2 79,3 78,9 0,71 3,4 2,0 1,9 2,1 4,5 2,6 0,0032 16 IE3
89 3VTB 90L6 1,1 1,5 940 11,1 79,9 81,9 81,0 0,70 4,9 2,9 2,8 2,1 4,5 2,6 0,0090 19 IE3
90 3VTB 100L6 1,5 2 960 14,9 81,1 82,8 82,5 0,74 6,2 3,7 3,5 2,6 6,2 3,3 0,0100 23,5 IE3
91 3VTB 112M6 2,2 3 960 21,9 83,9 84,9 84,3 0,76 8,6 5,2 5,0 2,1 5,9 2,6 0,0177 34 IE3
92 3VTB 132S6 3 4 965 29,7 85,0 87,2 87,0 0,81 10,7 6,5 6,1 2,2 6,6 2,9 0,0440 54 IE3
93 3VTB 132M6A 4 5,5 965 39,8 89,1 89,2 88,0 0,81 14,1 8,5 8,1 2,3 6,6 3,0 0,0579 62 IE3
94 3VTB 132M6B 5,5 7,5 960 54,7 88,9 89,1 88,0 0,81 19,4 11,7 11,1 2,4 6,7 3,1 0,0637 66 IE3
95 3VTB 160M6 7,5 10 970 73,8 89,0 89,9 89,5 0,82 25,7 15,5 14,8 2,1 6,8 2,9 0,1020 134 IE3
96 3VTB 160L6 11 15 970 108,3 89,6 90,5 90,3 0,82 37,3 22,6 21,4 2,2 7,0 3,0 0,1230 146 IE3
97 3VTB 180L6 15 20 980 146,2 90,0 91,3 91,2 0,81 60,0 30,9 29,3 3,3 7,3 2,8 0,2760 198 IE3
98 3VTB 200L6A 18,5 25 988 179 91,3 92,0 91,7 0,81 63 38 36 2,0 5,8 2,4 0,50 285 IE3
99 3VTB 200L6B 22 30 987 213 91,7 92,2 92,2 0,82 73 44 42 2,0 5,7 2,1 0,64 309 IE3
100 3VTB 225M6 30 40 989 290 92,3 92,9 92,9 0,83 98 53 55 1,9 6,4 2,3 0,89 392 IE3
101 3VTB 250M6 37 50 991 357 92,2 93,4 93,3 0,82 121 73 70 2,0 6,7 2,6 1,23 440 IE3
102 3VTB 280S6 45 60 993 433 92,9 93,8 93,7 0,81 149 90 86 2,3 7,3 2,6 1,70 635 IE3
103 3VTB 280M6 55 75 992 529 93,8 94,4 94,1 0,82 179 108 103 2,3 6,8 2,6 1,90 695 IE3
104 3VTB 315S6 75 100 992 722 94,6 95,0 94,7 0,82 242 147 139 2,4 7,1 2,6 2,40 900 IE3
105 3VTB 315M6A 90 125 993 866 95,1 95,4 95,1 0,82 290 175 167 2,6 7,6 2,7 2,93 965 IE3
106 3VTB 315M6B 110 150 992 1059 95,2 95,6 95,2 0,82 354 214 203 2,8 7,5 2,8 3,46 1110 IE3
107 3VTB 315M6C 132 175 992 1271 95,4 95,8 95,4 0,83 - 253 241 2,5 7,0 2,5 4,21 1230 IE3
108 3VTB 315M6D 160 220 992 1540 95,2 95,7 95,6 0,78 - 310 180 3,3 8,0 2,7 4,36 1235 IE3
109 3VTB 355 ML6A 200 270 989 1931 95,3 95,9 95,8 0,86 - 350 202 2,0 7,1 2,3 7,20 1740 IE3
110 3VTB 355 ML6B 250 340 990 2412 95,5 96,0 95,8 0,86 - 438 253 2,1 7,2 2,4 8,60 1950 IE3
111 3VTB 355 H6C 315 430 992 3033 96,0 96,3 96,1 0,86 - 550 318 2,0 7,1 2,2 12,70 2390 IE3
112 3VTB 355 H6D 355 480 991 3421 95,9 96,3 96,1 0,86 - 620 358 1,9 7,0 2,3 13,60 2500 IE3
113 VTB 400H6Bs 400 540 992 3851 95,6 96,3 96,3 0,84 - - 714 1,7 6,8 2,2 18,2 3050
114 VTB 400H6Cs 450 610 993 4328 95,8 96,3 96,0 0,83 - - 815 1,5 7,5 2,5 19,4 3250
115 VTB 450H6As 500 680 994 4804 96,6 96,9 96,8 0,88 - - 4912 1,2 6,7 2,6 36,5 3800
116 VTB 450H6Bs 560 760 994 5380 96,7 97,0 96,9 0,88 - - 5492 1,2 6,8 2,6 40,6 4300
117 VTB 450H6Cs 630 850 994 6053 96,7 97,1 97,0 0,89 - - 6112 1,3 7,0 2,6 45,0 4500
118 VTB 450H6Ds 710 960 994 6821 96,5 96,8 96,8 0,89 - - 6902 1,4 7,4 2,6 50,0 4890
119 VTB 500H6As 800 1080 995 7678 96,7 97,1 97,0 0,86 - - 8022 0,9 5,8 2,4 61,5 6200
120 VTB 500H6Bs 900 1210 995 8638 96,8 97,1 97,0 0,87 - - 8932 1,0 6,0 2,2 67,5 6550
121 VTB 500H6Cs 1000 1350 995 9598 96,4 97,0 97,1 0,86 - - 10022 1,0 6,4 2,5 70,0 6700
122 VTB 500H6Ds 1120 1510 996 10739 96,4 97,1 97,2 0,85 - - 11342 1,1 7,0 2,6 80,0 7130
123 VTB 500H6Es 1250 1680 996 11985 96,4 97,1 97,2 0,85 - - 12662 1,1 7,1 2,6 84,6 7460
18
General Purpose 3-phase Induction Motors
Weight (IMB3)
rotor current
rotor torque
Breakdown
Moment of
Efficiency
Locked
Locked
current
torque
torque
output
Power
inertia
speed
Rated
Rated
Rated
factor
Type
Item
load
Full
PN nN TN hN [%] at % of full load cos jN IN at rated voltage TL/TN IL/IN Tb/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] [A]230V [A]380V [A]400V [-] [-] [-] [kgm2] [kg]
124 VTB 63-8A 0,04 0,05 670 0,57 20 31 35 0,60 0,6 0,35 0,35 1,6 1,7 1,7 0,00024 3,5
125 VTB 63-8B 0,06 0,08 660 0,87 20 24 28 0,48 1,1 0,65 0,65 1,4 1,5 1,6 0,000307 4,1
126 VTB 71-8A 0,09 0,12 680 1,26 25 31 35 0,5 1,3 0,75 0,75 1,9 1,9 1,9 0,000736 4,7
127 VTB 71-8B 0,12 0,17 670 1,71 40 45 47 0,63 1,25 0,7 0,7 1,7 1,9 1,8 0,000946 5,6
128 VTB 80-8A 0,18 0,25 680 2,53 43 51 53 0,57 1,55 0,9 0,9 1,8 2,3 2,0 0,001693 7,2
129 VTB 80-8B 0,25 0,33 680 3,51 52 55 57 0,6 2,1 1,2 1,2 1,7 2,5 1,7 0,00207 8,7
130 VTB 90S-8 0,37 0,5 695 5,08 54,2 60,8 63,4 0,59 2,5 1,5 1,4 1,7 2,9 2,3 0,0021 13,4
131 VTB 90L-8 0,55 0,75 675 7,78 60,4 65,3 65 0,64 3,3 2 1,9 1,7 2,8 1,9 0,0024 15,3
132 VTB 100L-8A 0,75 1 710 10,1 65,9 70,5 71,1 0,66 4 2,4 2,3 1,4 3,5 1,9 0,009 23,6
133 VTB 100L-8B 1,1 1,5 705 14,9 67,6 71,8 72,2 0,65 5,9 3,6 3,4 1,6 3,6 1,9 0,01 26,3
134 VTB 112M-8 1,5 2 720 19,9 72,5 76,2 76,8 0,71 6,9 4,2 4,0 1,9 4,6 2,3 0,0192 31
135 VTB 132S-8 2,2 3 710 29,6 75,4 78,2 78 0,74 9,6 5,8 5,5 2,0 4,7 2,4 0,033 53
136 VTB 132M-8 3 4 710 40,4 78,5 80,7 80 0,74 12,7 7,7 7,3 2,3 5,0 3,0 0,044 65
137 VTB 160M-8A 4 5,5 705 54,2 81,5 82,7 81,5 0,76 16,2 9,8 9,3 2,2 5,0 2,7 0,06 85
138 VTB 160M-8B 5,5 7,5 710 74 82,1 83,7 83 0,75 22,2 13,4 12,8 2,7 5,5 3,0 0,077 95
139 VTB 160L-8 7,5 10 705 102 84,5 85,5 84,5 0,78 28,6 17,3 16,4 2,7 5,8 3,0 0,102 115
140 VTB 180L-8 11 15 730 144 87,7 89,2 89 0,76 40,8 24,7 23,5 2,0 5,5 2,4 0,213 165
141 VTB 200L8 15 20 733 195 88,8 90 89,5 0,83 51 30,5 29,1 2,2 5,5 2,1 0,45 255
142 VTB 225S8 18,5 25 735 240 88,8 90 89,5 0,81 64 39 37 2,0 5,6 2,0 0,58 280
143 VTB 225M8 22 30 735 286 90,0 90,8 90,4 0,80 76 46 44 2,0 5,2 1,8 0,68 315
144 VTB 250M8 30 40 738 388 91,0 92 91,5 0,84 98 59 56 2,5 6,3 2,1 1,27 430
145 VTB 280S8 37 50 737 479 92,0 93,1 92,8 0,83 121 73 69 2,0 5,3 1,8 1,47 535
146 VTB 280M8 45 60 737 583 92,0 92,8 92,5 0,84 145 88 84 2,1 5,4 2,0 1,8 590
147 VTB 315S8 55 75 735 715 92,0 93,0 92,7 0,81 184 111 106 2,0 5,3 1,9 2,16 720
148 VTB 315M8A 75 100 737 972 92,5 93,5 93,2 0,82 246 149 142 2,5 6,2 1,9 2,29 750
149 VTB 315M8B 90 125 737 1166 92,5 93,5 93,2 0,82 296 179 170 2,4 6,5 1,9 2,86 840
150 VTB 315M8C1 110 150 737 1425 92,3 93,1 93,3 0,79 375 227 215 2,3 5,4 2,2 3,46 1105
151 VTB 315M8D1 132 175 734 1717 92,7 93,3 93,2 0,81 439 266 252 2,3 5,4 2,2 3,69 1136
152 VTB 355ML8A 160 220 739 2068 95,1 95,5 95,0 0,80 - - 305 1,6 5,8 2,0 7,0 1680
153 VTB 355ML8B 200 270 740 2581 95,1 95,6 95,2 0,79 - - 384 1,8 6,2 2,1 7,7 1750
154 VTB 355H8Ds 250 340 742 3218 95,5 96,0 95,6 0,78 - - 484 1,3 6,0 2,0 12,9 2440
155 VTB 355H8Es 315 430 742 4054 95,6 96,0 95,8 0,78 - - 609 1,3 6,0 2,0 16,0 2590
156 VTB 400H8Ds 355 480 742 4569 95,3 95,9 95,9 0,77 - - 695 1,2 5,8 2,0 18,8 3200
157 VTB 400H8Es 400 540 742 5148 95,4 96,0 96,0 0,77 - - 782 1,2 5,9 2,0 21,0 3350
158 VTB 450H8Bs 450 610 746 5761 95,5 96,3 96,4 0,78 - - 5012 1,0 5,8 2,1 41,6 4400
159 VTB 450H8Cs 500 680 746 6401 95,5 96,3 96,4 0,78 - - 5572 1,0 5,8 2,1 46,0 4600
160 VTB 450H8Ds 560 760 746 7169 95,6 96,4 96,5 0,78 - - 6232 1,0 5,7 2,1 49,0 4770
161 VTB 450H8Es 630 850 746 8065 95,8 96,4 96,5 0,79 - - 6922 1,0 5,6 2,0 53,8 4980
162 VTB 500H8Bs 710 960 746 9089 96,0 96,6 96,7 0,81 - - 7582 1,0 6,0 2,4 92,4 6680
163 VTB 500H8Cs 800 1080 746 10241 96,0 96,6 96,7 0,80 - - 8652 1,1 6,3 2,5 95,8 6800
164 VTB 500H8Ds 900 1210 746 11522 96,1 96,8 96,9 0,80 - - 9712 1,0 6,0 2,4 108 7240
165 VTB 500H8Es 1000 1350 746 12802 96,1 96,8 96,9 0,80 - 10792 1,1 6,5 2,5 118 7570
1 insulation class H
2 at rated voltage 690 V
19
General Purpose 3-phase Induction Motors
Weight (IMB3)
rotor current
rotor torque
Breakdown
Moment of
Efficiency
Locked
Locked
current
torque
torque
output
Power
inertia
speed
Rated
Rated
Rated
factor
Type
Item
load
Full
PN nN TN hN [%] at % of full load cos jN IN at rated voltage TL/TN IL/IN Tb/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] [A]230V [A]380V [A]400V [-] [-] [-] [kgm2] [kg]
166 VTB 200L10A 7,5 10 580 123 82,5 84 85 0,68 32,5 19,7 18,7 1,7 3,5 2,1 0,4 240
167 VTB 200L10B 11 15 590 178 84,7 86,7 87,5 0,68 46,5 28,1 26,7 3,2 5,9 2,4 0,47 255
168 VTB 225S10 13 18 592 210 87,5 89,3 90,5 0,67 54 32,5 31 1,8 3,8 2 0,6 280
169 VTB 225M10 15 20 590 243 86 88 89 0,67 63 38 36,5 2,8 5,4 2 0,76 315
170 VTB 225M10z 18,5 25 590 299 84,3 87,1 87,7 0,64 83 50 47,5 2,8 5,5 2,1 0,76 325
171 VTB 250M10 22 30 592 355 87,5 89,6 90 0,70 88 53 50 3 5,8 2 1,27 430
172 VTB 280S10A 30 40 586 489 85,3 87,3 88,8 0,71 119 72 69 2 4,5 1,7 1,35 525
173 VTB 280S10B 37 50 583 606 87 90 91 0,75 136 82 78 1,9 4,5 1,5 1,61 565
174 VTB 280M10 45 60 587 732 88 90,5 91,6 0,76 162 98 93 2 4,5 1,6 2,03 630
175 VTB 315S10 45 60 588 731 90 91,5 92,1 0,71 173 105 99 2 4,1 2 2,16 720
176 VTB 315S10z 55 75 583 901 88 90,5 91,5 0,75 201 122 116 1,7 4,7 1,9 2,86 840
177 VTB 315M10 75 100 583 1229 88 90,5 91,5 0,75 274 166 158 1,8 4,9 1,5 3,01 895
178 VTB 400H10As 200 270 594 3216 94,4 95,1 95,0 0,82 - - 371 1,0 5,4 2,5 25,6 3010
179 VTB 400H10Bs 250 340 594 4019 94,4 95,2 95,2 0,79 - - 480 1,1 5,6 2,6 31,3 3270
180 VTB 450H10As 315 430 594 5064 94,9 95,5 95,5 0,81 - - 3412 1,0 5,9 2,2 49,4 4050
181 VTB 450H10Bs 355 480 594 5708 95,0 95,7 95,7 0,81 - - 3842 1,0 6,0 2,3 53,9 4130
182 VTB 450H10Cs 400 540 594 6431 95,0 95,7 95,7 0,81 - - 4322 1,1 6,4 2,3 58,3 4300
183 VTB 500H10As 450 610 594 7235 95,1 95,8 95,7 0,81 - - 4862 1,4 6,3 2,1 74,1 5420
184 VTB 500H10Bs 500 680 594 8039 95,2 95,9 95,8 0,82 - - 5332 1,5 6,6 2,2 85,5 5700
185 VTB 500H10Cs 560 760 593 9019 95,4 95,9 95,8 0,82 - - 5972 1,3 6,2 2,0 94,2 5950
186 VTB 500H10Ds 630 850 594 10129 95,5 96,0 96,0 0,82 - - 6702 1,7 6,9 2,2 108 6400
187 VTB 200L12 9 12 490 175 75,3 80,1 81,8 0,55 50 30,5 28,9 2,7 4,3 2,5 0,47 255
188 VTB 225S12 11 15 490 214 83,1 85,0 86,0 0,63 51 31 29,3 1,7 3,5 1,7 0,58 315
189 VTB 225M12 13 18 475 261 81,5 82,2 82,5 0,59 67 40,5 38,5 1,7 3,5 1,7 0,68 320
190 VTB 225M12z 15 20 491 292 80,5 83,5 84,4 0,58 77 46,5 44 2,7 4,6 1,8 0,68 350
191 VTB 250M12 18,5 25 490 361 84,0 86,0 87,8 0,65 81 49,5 47 1,7 3,5 1,8 1,27 430
192 VTB 280S12 22 30 491 428 86,9 89,2 89,6 0,61 101 61 58 2,3 4,5 1,8 1,47 535
193 VTB 280M12 30 40 490 585 85,6 88,2 89,0 0,62 136 83 78 1,8 3,5 1,8 1,8 570
194 VTB 315S12 37 50 492 718 87,5 89,9 90,4 0,58 177 107 102 2,6 4,5 1,9 2,29 730
195 VTB 315M12A 45 60 490 877 87,9 89,0 90,1 0,58 216 131 124 2 3,5 1,8 2,86 870
196 VTB 315M12B 55 75 490 1072 87,5 90,0 89,5 0,58 266 161 153 2,5 4,4 1,8 3,01 885
197 VTB 450H12As 160 220 495 3087 94,1 95,0 95,0 0,79 - - 308 0,9 5,9 2,6 30,0 3470
198 VTB 450H12Bs 200 270 495 3859 94,7 94,9 94,9 0,80 - - 381 0,9 5,7 2,3 33,7 3600
199 VTB 450H12Cs 250 340 493 4843 94,7 95,0 94,7 0,82 - - 465 0,8 5,1 2,2 40,0 3750
20
General Purpose 3-phase Induction Motors
Dimensions for FOOT MOUNTED MOTORS - IM B3
A-A
F
D
GA
HD
H
A
HA
E C B K AA
BB A
L AB
Motor type A B C D E F GA H K AA AB BB HA HD L
VTB 90S ... 140 100 56 24j6 50 8h9 27 90 10 10 50 170 153 220 305
VTB 90L ... 140 125 56 24j6 50 8h9 27 90 10 10 50 170 153 220 330
VTB 100L ... 160 140 63 28j6 60 8h9 31 100 14 12 45 200 172 240 376
VTB 112M ... 190 140 70 28j6 60 8h9 31 112 14 12 54 230 174 276 384
VTB 132S ... 216 140 89 38k6 80 10h9 41 132 16 12 56 278 182 310 463
VTB 132S-2B 216 140 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501
VTB 132M ... 216 178 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501
VTB 160M ... 254 210 108 42k6 110 12h9 45 160 20 15 60 305 256 370 612
VTB 160L ... 254 254 108 42k6 110 12h9 45 160 20 15 60 305 300 370 656
VTB 180M ... 279 241 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705
VTB 180L ... 279 279 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705
21
General Purpose 3-phase Induction Motors
HD
A
H
HA
A-A
D
BA1 BA2 AA K
F
GA E C B A
B1 AB
BB
L
3VTB200 318 305 - 133 55 110 16 59 200 32 19 80 400 113 113 380 520 850
3VTB225S4 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 930
3VTB225M2 356 286 311 149 55 110 16 59 225 34 19 85 440 115 115 380 570 900
3VTB225M4-6 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 930
3VTB250M2 406 349 - 168 60 140 18 64 250 37 24 90 480 135 135 445 635 1010
3VTB250M4-6 406 349 - 168 65 140 18 69 250 37 24 90 480 135 135 445 635 1040
3VTB280S2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 1135
3VTB280S4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 1135
3VTB280M2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 1135
3VTB280M4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 1135
3VTB315S2 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 1235
3VTB315S4-6 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 1265
3VTB315M2A;B 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 1235
3VTB315M4A;B;6A 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 1265
3VTB280M6B 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 1355
3VTB315M2C 508 406 457 216 70 140 20 74,5 315 48 28 135 610 135 205 600 805 1290
3VTB315M4C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 1320
3VTB315M6C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 1320
3VTB315M6D 508 406 457 216 90 170 25 95 315 48 28 135 610 135 205 600 805 1320
3VTB 355 ML (2) 610 560 630 254 80 170 22 85 355 50 28 150 720 250 300 890 935 1580
3VTB 355 ML (4, 6) 610 560 630 254 100 210 28 106 355 50 28 150 720 250 300 890 935 1620
3VTB 355 H (2) 610 900 - 200 70 140 20 74.5 355 45 28 160 730 265 265 1045 995 1800
3VTB 355 H (4, 6) 610 900 - 200 100 210 28 106 355 45 28 160 730 265 265 1045 995 1870
22
General Purpose 3-phase Induction Motors
Dimensions for FOOT MOUNTED MOTORS - IM B3
A-A
AC
F
D
GA
HD
A
HA
H
BA AA K
E C B A
BB AB
L
Motor type A B C D E F GA H HA K AA AB AC BA BB HD L
VTB 200 L8-12 318 305 133 55m6 110 16h9 59 200 32 19 80 400 450 100 380 485 825
VTB 225 S8-12 356 286 149 60m6 140 18h9 64 225 34 19 85 445 505 110 355 535 865
VTB 225 M8-12 356 311 149 60m6 140 18h9 64 225 34 19 85 445 505 110 380 535 890
VTB 250 M8-12 406 349 168 65m6 140 18h9 69 250 36 24 90 495 540 120 420 590 965
VTB 280 S8-12 457 368 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040
VTB 280 M8-12 457 419 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040
VTB 315 S8-12 508 406 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210
VTB 315 M8-12 508 457 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210
AD
A-A
HD
A
D
GA A
H
HA
BA BA AA K
E C B A
BB AB
L
VTB 355...s 2 610 900 200 70 140 20 74,5 355 45 28 160 730 - 265 1045 995 1800
VTB 355...s 4÷8 610 900 200 100 210 28 106 355 45 28 160 730 - 265 1045 995 1870
VTB 400...s 2 686 1000 224 80 170 22 85 400 50 35 175 840 520 265 1160 1255 1980
VTB 400...s 4÷8 686 1000 224 110 210 28 116 400 50 35 175 840 520 265 1160 1255 1960
VTB 450...s 4÷12 750 1120 254 110 210 28 116 450 60 35 205 940 560 340 1320 1356 2105
VTB 500...s 4÷10 850 1250 280 120 210 32 127 500 70 42 223 1050 560 300 1450 1470 2430
23
General Purpose 3-phase Induction Motors
T LA
HB
A-A A
R=O M
F
D
N
P
GA A S
45
°
E
L 22,5° 45°
24
General Purpose 3-phase Induction Motors
Type of motor D E F GA M N P LA T S HB L
VTB 90S ... 24j6 50 8h9 27 165 130j6 200 8 3,5 12 130 305
VTB 90L ... 24j6 50 8h9 27 165 130j6 200 8 3,5 12 130 330
VTB 100L ... 28j6 60 8h9 31 215 180j6 250 11 4 15 140 376
VTB 112M ... 28j6 60 8h9 31 215 180j6 250 12 4 15 164 384
VTB 132S ... 38k6 80 10h9 41 265 230j6 300 12 4 15 178 463
VTB 132S-2B 38k6 80 10h9 41 265 230j6 300 12 4 15 178 501
VTB 132M ... 38k6 80 10h9 41 265 230j6 300 12 4 15 178 501
VTB 160M ... 42k6 110 12h9 45 300 250j6 350 13 5 19 210 612
VTB 160L ... 42k6 110 12h9 45 300 250j6 350 13 5 19 210 656
VTB 180M ... 48k6 110 14h9 51,5 300 250j6 350 13 5 19 228 705
VTB 180L ... 48k6 110 14h9 51,5 300 250j6 350 13 5 19 228 705
AC
AD
T LA
S
A-A
A M
F
D
N
P
R=O
GA
A
45
°
22,5° 45°
E
Motor type D E F GA AC AD L LA M N P T S
Holes
VTB 200 L8-12 55m6 110 16h9 59 450 340 825 16,5 350 300j6 400 5 18 4
VTB 225 S8-12 60m6 140 18h9 64 505 360 865 18 400 350j6 450 5 18 8
VTB 225 M8-12 60m6 140 18h9 64 505 360 890 18 400 350j6 450 5 18 8
VTB 250 M8-12 65m6 140 18h9 69 540 405 965 19 500 450j6 550 5 18 8
VTB 280 S8-12 75m6 140 20h9 79,5 620 440 1040 20 500 450j6 550 5 18 8
VTB 280 M8-12 75m6 140 20h9 79,5 620 440 1040 20 500 450j6 550 5 18 8
VTB 315 S8-12 80m6 170 22h9 85 620 440 1210 22 600 550j6 660 6 22 8
VTB 315 M8-12 80m6 170 22h9 85 620 440 1210 22 600 550j6 660 6 22 8
25
General Purpose 3-phase Induction Motors
A-A
F
GA
HB
M
LA
A R=0
T
E
A
S
N
P
VTB 355...s* 4÷8 100 210 28 106 640 1955 24 740 680 800 22 6
VTB 400...s* 4÷8 110 210 28 116 725 2016 37 940 880 1000 23 6
VTB 450...s* 4÷12 110 210 28 116 835 2162 30 1080 1000 1150 28 6
VTB 500...s* 4÷12 120 210 32 127 835 2505 30 1080 1000 1150 28 6
S
A-A
A
R=O M
F
HD
4x90°
D
N
P
GA A
HA
H
E C B K AA
BB A
L AB
Motor type A B C D E F GA H K M N P S LA T AA AB BB HA HD L
VTB 56-.A 90 71 36 9j6 20 3h9 10,2 56 8 100 80j6 120 7 8 3 30 110 92 7 154 183
VTB 56-.B 90 71 36 9j6 20 3h9 10,2 56 8 100 80j6 120 7 8 3 30 110 92 7 154 193
VTB 63-.A 100 80 40 11j6 23 4h9 12,5 63 10 115 95j6 140 10 9 3 36 124 106 8,5 165 200
VTB 63-.B 100 80 40 11j6 23 4h9 12,5 63 10 115 95j6 140 10 9 3 36 124 106 8,5 165 210
VTB 71-.A 112 90 45 14j6 30 5h9 16 71 10 130 110j6 160 10 9 3,5 45 142 116 8 182 223
VTB 71-.B 112 90 45 14j6 30 5h9 16 71 10 130 110j6 160 10 9 3,5 45 142 116 8 182 245
VTB 80-.A 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 266
VTB 80-.B 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 278
3VTB 80-.A 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 278
3VTB 80-.B 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 306
3VTB 90S-2,4,6 140 100 56 24j6 50 8h9 27 90 10 165 130j6 200 12 8 3,5 47 182 153 10 238 331
3VTB 90L-2 140 125 56 24j6 50 8h9 27 90 10 165 130j6 200 12 8 3,5 47 182 153 10 238 331
3VTB 90L-4,6 140 125 56 24j6 50 8h9 27 90 10 165 130j6 200 12 8 3,5 47 182 153 10 238 356
3VTB 100L-2,6 160 140 63 28j6 60 8h9 31 100 12 215 180j6 250 15 11 4 52 202 170 12 257 377
3VTB 100L-4A,4B 160 140 63 28j6 60 8h9 31 100 12 215 180j6 250 15 11 4 52 202 170 12 257 417
3VTB 112M-2,6 190 140 70 28j6 60 8h9 31 112 12 215 180j6 250 15 12 4 52 222 170 14 280 398
3VTB 112M-4 190 140 70 28j6 60 8h9 31 112 12 215 180j6 250 15 12 4 52 222 170 14 280 425
3VTB 132S 216 140 89 38k6 80 10h9 41 132 12 265 230j6 300 15 12 4 61 266 220 18 329 512
3VTB 132M 216 178 89 38k6 80 10h9 41 132 12 265 230j6 300 15 12 4 61 266 220 18 329 512
3VTB 160M 254 210 108 42k6 110 12h9 45 160 15 300 250j6 350 19 13 5 81 320 200 25 383 643
3VTB 160L 254 254 108 42k6 110 12h9 45 160 15 300 250j6 350 19 13 5 81 320 300 25 383 643
3VTB 180M 279 241 121 48k6 110 14h9 51,5 180 15 300 250j6 350 19 13 5 92 353 320 27 414 723
3VTB 180L 279 279 121 48k6 110 14h9 51,5 180 15 300 250j6 350 19 13 5 92 353 320 27 414 723
26
General Purpose 3-phase Induction Motors
Motor type A B C D E F GA H HA K AA AB BB HD L LA M N P T S
VTB 90S ... 140 100 56 24j6 50 8h9 27 90 10 10 50 170 153 220 305 8 165 130j6 200 3,5 12
VTB 90L ... 140 125 56 24j6 50 8h9 27 90 10 10 50 170 153 220 330 8 165 130j6 200 3,5 12
VTB 100L ... 160 140 63 28j6 60 8h9 31 100 14 12 45 200 172 240 376 11 215 180j6 250 4 15
VTB 112M ... 190 140 70 28j6 60 8h9 31 112 14 12 54 230 174 276 384 12 215 180j6 250 4 15
VTB 132S ... 216 140 89 38k6 80 10h9 41 132 16 12 56 278 182 310 463 12 265 230j6 300 4 15
VTB 132S-2B 216 140 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501 12 265 230j6 300 4 15
VTB 132M ... 216 178 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501 12 265 230j6 300 4 15
VTB 160M ... 254 210 108 42k6 110 12h9 45 160 20 15 60 305 256 370 612 13 300 250j6 350 5 19
VTB 160L ... 254 254 108 42k6 110 12h9 45 160 20 15 60 305 300 370 656 13 300 250j6 350 5 19
VTB 180M ... 279 241 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705 13 300 250j6 350 5 19
VTB 180L ... 279 279 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705 13 300 250j6 350 5 19
T LA
A-A M
HD
A R=0
N
P
D
GA A 45
°
H
45°
HA
22,5°
BA1 BA2 AA K
E C B A
B1 AB
BB
L
3VTB 200 318 305 - 133 55 110 16 59 200 32 19 80 400 113 113 380 520 16,5 400 350 300 5 850 19 4
3VTB 225S4 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 18 450 400 350 5 930 19 8
3VTB 225M2 356 286 311 149 55 110 16 59 225 34 19 85 440 115 115 380 570 18 450 400 350 5 900 19 8
3VTB 225M4-6 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 18 450 400 350 5 930 19 8
3VTB 250M2 406 349 - 168 60 140 18 64 250 37 24 90 480 135 135 445 635 23 550 500 450 5 1010 19 8
3VTB 250M4-6 406 349 - 168 65 140 18 69 250 37 24 90 480 135 135 445 635 23 550 500 450 5 1040 19 8
3VTB 280S2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 280S4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 280M2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 280M4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 315S2 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1235 24 8
3VTB 315S4-6 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1265 24 8
3VTB 315M2A;B 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1235 24 8
3VTB 315M4A;B;6A 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1265 24 8
3VTB 315M6B 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1355 24 8
3VTB 315M2C 508 406 457 216 70 140 20 74,5 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1290 24 8
3VTB 315M4C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1320 24 8
3VTB 315M6C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1320 24 8
3VTB 315M6D 508 406 457 216 90 170 25 95 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1320 24 8
3VTB 355 ML (2) 610 560 630 254 80 170 22 85 355 50 28 150 720 250 300 890 935 24 800 740 680 6 1580 22 8
3VTB 355 ML (4,6) 610 560 630 254 100 210 28 106 355 50 28 150 720 250 300 890 935 24 800 740 680 6 1620 22 8
3VTB 355 H (2) 610 900 - 254 70 140 20 74,5 355 45 28 160 730 265 265 1045 995 24 800 740 680 6 1854 22 8
3VTB 355 H (4,6) 610 900 - 254 100 210 28 106 355 45 28 160 730 265 265 1045 995 24 800 740 680 6 1924 22 8
VTB 355 ML8 610 560 630 254 100 210 28 106 355 50 28 150 720 250 300 890 935 24 800 740 680 6 1620 22 8
27
General Purpose 3-phase Induction Motors
Dimensions for FOOT/FLANGE MOUNTED MOTORS - IM B35
A-A
F
D
AC
GA
T LA
S
M
A
HD
N
P
R=O 45
°
HA
H
A 22,5° 45°
BA AA K
E C B A
BB AB
L
Motor type A B C D E F GA H HA K AA AB AC BA BB HD L LA M N P T S
Holes
VTB 200 L8-12 318 305 133 55m6 110 16h9 59 200 32 19 80 400 450 100 380 485 825 16,5 350 300 400 5 18 4
VTB 225 S8-12 356 286 149 60m6 140 18h9 64 225 34 19 85 445 505 110 355 535 865 18 400 350 450 5 18 8
VTB 225 M8-12 356 311 149 60m6 140 18h9 64 225 34 19 85 445 505 110 380 535 890 18 400 350 450 5 18 8
VTB 250 M8-12 406 349 168 65m6 140 18h9 69 250 36 24 90 495 540 120 420 590 965 19 500 450 550 5 18 8
VTB 280 S8-12 457 368 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040 20 500 450 550 5 18 8
VTB 280 M8-12 457 419 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040 20 500 450 550 5 18 8
VTB 315 S8-12 508 406 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210 22 600 550 660 6 22 8
VTB 315 M8-12 508 457 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210 22 600 550 660 6 22 8
A-A AD
D
T LA GA
HD
S
A R=0
M
N
P
A
H
HA
BA BA AA K
E C B A
BB AB
L
Type of Poles
motor A B C D E F GA H HA K AA AB AD BA BB HD L LA M N P S T
VTB 355...s 2 610 900 254 70 140 20 74.5 355 45 28 160 730 344 265 1045 995 1854 24 740 680 800 22 6
VTB 355...s 4÷8 610 900 254 100 210 28 106 355 45 28 160 730 344 265 1045 995 1924 24 740 680 800 22 6
VTB 400...s 2 686 1000 280 80 170 22 85 400 50 35 175 840 520 265 1160 1255 2031 30 940 880 1000 25 6
VTB 400...s 4÷8 686 1000 280 110 210 28 116 400 50 35 175 840 520 265 1160 1255 2016 30 940 880 1000 25 6
VTB 450...s 4÷12 750 1120 315 110 210 28 116 450 60 35 205 940 560 340 1320 1356 2162 30 1080 1000 1150 28 6
VTB 500...s 4÷10 850 1250 355 120 210 32 127 500 70 42 223 1050 560 300 1450 1470 2505 30 1080 1000 1150 286
28
General Purpose 3-phase Induction Motors
Dimensions for FLANGE MOUNTED MOTORS - IM B14
45°
T LE
HB
A
A-A
4x90°
R=O
F
M
N
P
D
GA
A
E
S
L
VTB 56- .A1 B14/C1 9j6 20 3h9 10,2 85 70j6 105 M6 2,5 15 98 183
VTB 56- .A2 B14/C2 9j6 20 3h9 10,2 65 50j6 80 M5 2,5 12,5 98 183
VTB 56- .B1 B14/C1 9j6 20 3h9 10,2 85 70j6 105 M6 2,5 15 98 193
VTB 56- .B2 B14/C2 9j6 20 3h9 10,2 65 50j6 80 M5 2,5 12,5 98 193
VTB 63- .A1 B14/C1 11j6 23 4h9 12,5 100 80j6 120 M6 3 14 102 200
VTB 63- .A2 B14/C2 11j6 23 4h9 12,5 75 60j6 90 M5 2,5 9,5 102 200
VTB 63- .B1 B14/C1 11j6 23 4h9 12,5 100 80j6 120 M6 3 14 102 210
VTB 63- .B2 B14/C2 11j6 23 4h9 12,5 75 60j6 90 M5 2,5 9,5 102 210
VTB 71- .A1 B14/C1 14j6 30 5h9 16 115 95j6 140 M8 3 14 111 223
VTB 71- .A2 B14/C2 14j6 30 5h9 16 85 70j6 105 M6 2,5 12 111 223
VTB 71- .B1 B14/C1 14j6 30 5h9 16 115 95j6 140 M8 3 14 111 245
VTB 71- .B2 B14/C2 14j6 30 5h9 16 85 70j6 105 M6 2,5 12 111 245
VTB 80- .A1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 120 266
VTB 80- .A2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 120 266
VTB 80- .B1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 120 278
VTB 80- .B2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 120 278
3VTB 80- .A1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 119 278
3VTB 80- .A2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 119 306
3VTB 80- .B1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 119 278
3VTB 80- .B2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 119 306
3VTB 90S 2,4,6,L2 B14/C1 24j6 50 8h9 27 130 110j6 160 M8 3,5 10 148 331
3VTB 90S 2,4,6,L2 B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 148 331
3VTB 90L 4,6 B14/C1 24j6 50 8h9 27 130 110j6 160 M8 3,5 10 148 356
3VTB 90L 4,6 B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 148 356
3VTB 100L2,6 B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 157 377
3VTB 100L2,6 B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 157 377
3VTB 100L4A,4B B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 157 417
3VTB 100L4A,4B B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 157 417
3VTB 112M2,6 B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 168 398
3VTB 112M2,6 B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 168 398
3VTB 112M4 B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 168 425
3VTB 112M4 B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 168 425
3VTB 132S B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 197 512
3VTB 132S B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 197 512
3VTB 132M B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 197 512
3VTB 132M B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 197 512
29
General Purpose 3-phase Induction Motors
45°
T LE
HB
A
A-A
4x90°
R=O
F
M
N
P
D
GA
A
E
S
L
VTB 90S ... B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 130 305
VTB 90L ... B14/C1 24j6 50 8h9 27 130 110j6 160 M8 3,5 10 130 330
VTB 90L ... B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 130 330
VTB 100L ... B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 140 376
VTB 100L ... B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 140 376
VTB 112M ... B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 164 384
VTB 112M ... B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 164 384
VTB 132S ... B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 178 463
VTB 132S ... B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 178 463
VTB 132S-2B B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 178 501
VTB 132S-2B B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 178 501
VTB 132M ... B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 178 501
VTB 132M ... B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 178 501
VTB 160M ... B14/C1 42k6 110 12h9 45 265 230j6 300 M12 4 13 210 612
VTB 160M... B14/C2 42k6 110 12h9 45 215 180j6 250 M12 4 20 210 612
VTB 160L ... B14/C1 42k6 110 12h9 45 265 230j6 300 M12 4 13 210 656
VTB 160L ... B14/C2 42k6 110 12h9 45 215 180j6 250 M12 4 20 210 656
30
General Purpose 3-phase Induction Motors
3
7
4
6 8
22
5 9
21
12 10
14 11
23 Item Description
20 15 1 terminal box cover
2 rubber gasket
3 terminal board
4 terminal box
19 5 rubber gasket
6 gland
16 13 7 terminal box complete
8 fan cover
9 fan
15 10 tie rod
11 NDE shield
12 stator
13 foot
18 17 14 spring washer
15 bearing
16 rotor
17 DE shield
18 shaft seal
19 key
20 flange B5
21 flange B14/C1
22 flange B14/C2
23 name plate
DE - drive end
NDE - non drive end
31
General Purpose 3-phase Induction Motors
15
17
25
18
20 19
16
7
24 14
13
22 12
11
3
23 10
21
5
Item Description
1 DE shield
2 2 rotor
6 8 3 shaft seal
5 4 shaft seal cover
9 5 bearing
1 6 key
3 7 name plate
4 81 sx foot
91 dx foot
10 NDE shield
11 fan
12 seeger ring
13 fan cover
14 rubber gasket
15 terminal box cover
16 terminal board
17 rubber gasket
18 terminal box
19 glands
20 terminal box complete
21 spring washer
22 stator
232 flange B14/C2
242 flange B14/C1
25 flange B5
32
General Purpose 3-phase Induction Motors
13
12
15 11
10
25 14 24b 21b
24a 16
4b 9
17
18
26
3b
8b
22b
7a 19
4a 7b 23b
20
24a
6
2
Item Description
5 1 DE shield
2 rotor
3a,b shaft seal
22a 23a 4a,b bearing
5 key
6 housing with feet
1
7a,b internal bearing cap
3a 8a 8a,b external bearing cap
9 NDE shield
10 fan
21a
11 seeger ring
12 fan cover
13 terminal box cover
14 terminal board
15 rubber gasket
16 terminal box housing
17 rubber gasket
18 cable glands
19 fan cover support
20 spring washer
21a,b seeger ring
22a,b grease shield
23a,b bearing internal ring
24a,b grease nipple
25 flange B5
26 rubber gasket
DE - drive end
NDE - non drive end
33
General Purpose 3-phase Induction Motors
12
11
10
22
26
13
9
6
7
2 3
5
7 8b
25
23
1
4 24
23
8a 20
22 14
16
19
25 17
18
Item Description
27 15 1 DE shield
2 rotor
3 shaft seal
4 DE bearing
5 key
6 housing with feet
3 24 7 internal bearing cap
8a,b external bearing cap
21 9 NDE shield
10 fan
11 seeger ring
12 fan cover
13 NDE bearing
14 terminal box cover
15 terminal cover support
16 rubber gasket
17 terminal box housing
18 rubber gasket
19 cable glands
20 fan cover support
21 spring washer
22 seeger ring
23 grease shield *
24 bearing internal ring *
25 DE grease nipple
26 NDE grease nipple
27 flange B5
34
General Purpose 3-phase Induction Motors
PRODUCT RANGE
Three-phase motors with from 0,04kW up to 1400kW general purpose, pumps,
INDUCTION MOTORS
GENERAL PURPOSE
(Efficiency classes
IE1, IE2, IE3, IE4)
high voltage and high efficiency drives used for own needs
motors series VTB with cast-iron of power plants
HIGH VOLTAGE
AC and DC brakes.
areas endangered
by explosion (without methane)
where a mixture of
explosive gas
and vapours may occur
Low voltage NEMA motors from 1HP up to 250HP general industrial application,
SIE series (in compliance with pumps, fans
NEMA MOTORS
35
VEMAT MOTORI S.r.l. - Registered office: Via Pantano, 2 - 20122 Milano - Italy
Productive unit and administrative offices: Via Gualda, 10 Z.I. - 36075 Montecchio Maggiore (VI) - Italy
Tel. +39 0444 491973 r.a. - Fax +39 0444 491978 - e-mail: [email protected] - www.vemat.it