0% found this document useful (0 votes)
17 views

Vemat Ie3 en x5 Final-1

The document is a product catalogue for General Purpose 3-phase Induction Motors, detailing compliance with efficiency standards IEC 60034-30 and EU Regulations 640/2009 and 4/2014. It includes information on motor specifications, efficiency classes, technical data, and various features such as insulation classification, vibration levels, and mounting arrangements. The catalogue emphasizes the importance of energy efficiency and provides guidelines for selecting appropriate motors based on their efficiency ratings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

Vemat Ie3 en x5 Final-1

The document is a product catalogue for General Purpose 3-phase Induction Motors, detailing compliance with efficiency standards IEC 60034-30 and EU Regulations 640/2009 and 4/2014. It includes information on motor specifications, efficiency classes, technical data, and various features such as insulation classification, vibration levels, and mounting arrangements. The catalogue emphasizes the importance of energy efficiency and provides guidelines for selecting appropriate motors based on their efficiency ratings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

Gener

al Purpose
3-phase
Induction Moto
Comply with the new efficiency classes
for low-voltage three-phase motors
IEC 60034-30 standard
and EU Regulation 640/2009, 4/2014
Ener
gy Efficient
Motors
series 3VTB

Product Catalogue
General Purpose 3-phase Induction Motors

02
General Purpose 3-phase Induction Motors
General Purpose 3-phase Induction Motors

Contents

General information pages 5-14

Introduction to 3VTB motors

Efficiency of motors

Ratings-tolerances

Standards

Insulation classification

Terminal box

Vibration and noise level

Degree of protection

Mounting arrangements

Bearings

Permissible loads on the shaft end

Housing, endshields

Description of the customised executions

Ordering information

Technical data pages 16-20

Dimensional drawings pages 21-30

List of motor parts pages 31-34

Production program page 35

04
General Purpose 3-phase Induction Motors

INTRODUCTION

New efficiency classes for the low-voltage three-phase motors (IE = International Efficiency).

Along with the international discussion on energy efficiency a worldwide harmonized energy efficiency
standard classification system has been established for low-voltage three-phase asynchronous motors.
For many years low-voltage three-phase motors in the European Union have been sold in three efficiency classes
EFF3, EFF2 and EFF1. Aside from this, many different efficiency classification systems have been introduced and
well-proven in many countries all over the world.

This was the reason for the International Electrotechnical Commission IEC to develop and publish an energy
efficiency standard which replaces all previous national issues. In parallel IEC developed and issued a new
standard for determining motor efficiency. The new standard IEC 60034-30-1 defines and harmonizes worldwide
the efficiency classes IE1, IE2, IE3 and IE4 for low-voltage three-phase motors in the power range from 0.12 kW
to 1000 kW (2p=2, 4, 6, 8)

IE1 = Standard Efficiency

IE2 = High Efficiency

IE3 = Premium Efficiency


According to IEC 60034-30-1 standard the efficiency has to be determined according to the new
requirements given in the IEC 60034-2-1 standard.

According to the Comission Regulation (EC) No 640/2009 (introduced in July 2009) including
Comission Regulation (EC) No 4/2014 the required efficiency class of general-purpose motors
with 2p=2, 4, 6 (introduced to the market in the future) will be as follows:

From 1 January 2017: motors with a rated output between


0.75 - 375 kW shall have a minimum efficiency class of IE3,
or IE2 if they are operated/equipped with electronic
speed control (VSD).

Electronic speed control is carried out using a frequency converter (VSD) that adjusts the
speed of the motor - and therefore the torque produced - based on the energy needed.

05
General Purpose 3-phase Induction Motors

EFFICIENCY OF MOTORS
The present catalogue describes the electric motors which belong to the efficiency class IE3 (Premium
Efficiency) and motors excluded from the Regulations (EC) 640/2009 and 4/2014 (motors with 2p = 8, 10, 12
and with rated output below 0.75kW and above 375kW).

Comparison between the efficiency of Vemat motors (for example 2p=4)


and efficiency class IE2/IE3 requirements according to the IEC 60034-30-1.

94
Efficiency [%]

86

78

70
0,1 1 10 100 400
PN [kW]

IE3 Premium Efficiency (Vemat)


IE2 High Efficiency (Vemat)

The efficiency class system specified under IEC 60034-30-1 is valid for low voltage three phase
squirrel cage induction motors with the following specifications:

· Rated voltage up to 1.000 V


· Rated output between 0.12 kW and 1000 kW
· Either 2, 4, 6 or 8 poles
· Rated on the basis of continuous duty (S1)
Supplied directly from mains
With ambient temperature within the range of -30°C ÷ + 60°C
With altitude up to 4000 m. a.s.l.

Motors with flanges, feet and/or shafts with mechanical dimensions different from IEC 60072-1
are also covered by this standard.

06
General Purpose 3-phase Induction Motors
RATINGS - TOLERANCES

Permissible deviations between real values and catalogue values according to the IEC 60034-1:

Power factor cos j Dcosj = -1/6 (1- cosjN)


Efficiency h Dh = -15%(100-hN) for PNŁ150kW
Dh = -10%(100-hN) for PN>150kW
Speed n Dn = ±20%(ns-nN) for PN>1kW
Dn = ±30%(ns-nN) for PNŁ1kW
Locked rotor current IL/IN D(IL/IN) = +20% (IL/IN)
Locked rotor torque TL/TN min (TL/TN) = -15% (TL/TN)
max (TL/TN) = +25% (TL/TN)
Breakdown torque TB/TN D(TB/TN) = -10% (TB/TN)
Moment of inertia J [kgm2] DJ = ±10% J
Sound pressure level LpA [dB] DLpA = +3 dB /A/

STANDARDS
The electric motors are manufactured according to the international standards:

Rating and performance IEC 60034-1


Methods for determining losses and efficiency IEC 60034-2-1
Classification of degrees of protection IEC 60034-5
Methods of cooling IEC 60034-6
Symbols of construction and mounting arrangements IEC 60034-7
Terminal markings and direction of rotation IEC 60034-8
Noise limits IEC 60034-9
Dimensions and output of electric machines IEC 60072-1
Vibration limits IEC 60034-14

New IEC standards regarding efficiency classes (IEC 60034-30-


1) and efficiency measurements (IEC 60034-2-1)

The resulting efficiency values differ from those obtained under the previous
IE1
IEC 60034-2:1996 testing standard.
It must be noted that the efficiency values are only comparable if they are obtained
using the same measuring method.
IE2
EU Regulation 640/2009 and 4/2014 adapted on 6 January 2014
Commission Regulation 640/2009, adapted on 22 July 2009, specifies the
requirements regarding the ecodesign of electric motors and the use of electronic
speed control (VSD). IE3
All the motors are manufactured according to
Quality Assurance System consistent with ISO 9001.
ISO9001
IEC
The motors covered by the present catalogue comply with the regulations
and standards effective in other countries, consistent with IEC standards.

All the motors described in the present catalogue are provided with CE mark.

07
General Purpose 3-phase Induction Motors

INSULATION CLASSIFICATION
The insulation system of an electric motor is determined by a given insulation Symbols of thermal resistance classes
class on the basis of its thermal resistance. (permissible insulation temperatures
This thermal resistance should be guaranteed by the entire set of electric at 40°C ambient temperature)
insulating materials used in the motor insulating system.
Symbol Temperature [° C]
Thermal resistance classification is related to the temperature of the hotspot
in the insulation occurring during rated operating conditions of the electric
motor, allowing for the highest permissible rise in average temperature. A 105
This rise should be selected so that at the highest permissible ambient E 120
temperature, the temperature of the hotspot in insulation will not exceed the B 130
value assigned to a given thermal resistance class.
F 155
H 180

Ambient temperature
Insulation class F in an electric motor means that
at ambient temperature of 40°C the temperature
Maximal rise of the winding may be max. 105°C with the
temperature rise
additional temperature margin of 10°C
A Temperature margin (under specified measuring conditions in
40° 60° 5°
accordance with the IEC 60034-1 standard).
Insulation class

B
40° 75° 5°
Class F
The standard motors made by Vemat in their basic
40° 80° 10°
version have the insulation class F while the
temperature rise is for class B.
F This means longer life for motors.
40° 105° 10°
For special request we can deliver motors equipped
with insulation class H.
H
40° 125° 15° Strengthened insulation system gives possibility
to safe operation with frequency converters.

MOTOR FEET
Motors with frame size Ł 132 have screwed feet.
Motors with frame size > 132 up to 315 have screwed feet or feet integrated with the motor housing.
Motors with frame size from 355 have feet integrated with the motor housing.

TERMINAL BOX
The terminal boxes of low voltage motors have threaded inlet Low voltage high-power motors contain terminal boxes with
holes designed for mounting cable glands. cable gland seals.
The box contains a terminal board with marked terminals
making possible connection of supply cables. The circuits of thermal protection and anticondensation heaters
are connected to separate terminal boxes.
In addition, terminal boxes may be provided with additional
terminals connected to the ends of thermal protection or Inside the boxes there are special clamps used to ground the
anticondensation heater circuits and extra glands to connect supply cable armouring.
these circuits.

VIBRATION LEVEL AND NOISE LEVEL


The rotor balancing method guarantees that a standard vibration level A is maintained in accordance with
the IEC 60034-14 and a standard sound power level is maintained in accordance with the IEC 60034-9.
On customer’s demand the motors can be made with reduced vibration or noise level. level A
08
General Purpose 3-phase Induction Motors
INTERNATIONAL PROTECTION MARKING IP

According to the IEC 60034-5 standard the electric motors are


provided with IP code which determines the degree of protection
(ensured by the housing) against penetration of solid matter and
fluids.
IP55
PROTECTION AGAINST PENETRATION PROTECTION AGAINST
OF SOLID MATTER PENETRATION OF FLUIDS IK MECHANICAL PROTECTION

1st digit DESCRIPTION 2nd digit DESCRIPTION 3rd digit DESCRIPTION

00 No protection

0 Not protected
Not protected 01 150 g Striking energy:
0 1 Protected against vertically 0.15 J
10 cm
falling drops of water

Protected against
solid bodies larger than 200 g
1 50 mm Protected against 02 Striking energy:
15 10 cm
2 15 vertically falling 0.20 J
drops of water up to 15°

Protected against
solid bodies 60 60
03 250 g Striking energy:
2 Protected against
larger than 0.37 J
12 mm 3 rain up to 60° 15 cm

Protected against 250 g


3 solid bodies Protected against 04 Striking energy:
larger 4 rain falling from any 0.50 J
20 cm
than 2.5 mm direction

Protected against 350 g


4 solid bodies Protected against 05 Striking energy:
5
larger sprayed water 20 cm 0.70 J
than 1 mm from any direction

250 g
Protected against Protected against 06 Striking energy:
5 deposition of dust 6 temporary 40 cm 1J
immersion

7 Protected against immersion 0.5 kg


Totally between 0.15 and 1 m 07 Striking energy:
6 protected against 40 cm
deposition of dust 8 Protected against immersion at 2J
preset pressure and time

1.25 kg
All Vemat standard motors are manufactured with IP 55 degree of protection 08 Striking energy:
according to the standard in force (IEC 60034-5). The following table lists its 40 cm 5J
characteristics.

Each size 80 to 180 motor is equipped with seal rings (Simmerring or V-ring) 2.5 kg
on drive side and on non drive side. Labyrinth seals protect the motors from
size 200 and above. 09 40 cm
Striking energy:
10 J
The terminal box is sealed with a gasket.
5 kg
Motors with a higher degree of protection are 10
40 cm
Striking energy:
20 J
available on request.

09
General Purpose 3-phase Induction Motors

MOUNTING ARRANGEMENTS

According to the IEC 60034-7 standard

Horizontal shaft Vertical shaft

Designation Designation

Frame size Frame size


Code II Code I Code II Code I

IM 1001 IM B3 56 ÷ 500 IM 1011 IM V5 56 ÷ 315


without 3VTB 315 6B,C,D
without VTB 315 M8C,D

IM 1051 IM B6 56 ÷ 280 IM 1031 IM V6 56 ÷ 315


without 3VTB 315M 6B,C,D
without VTB 315 M8C,D

IM 1061 IM B7 56 ÷ 280 IM 2011 IM V15 56 ÷ 355


or IM 2111

IM 1071 IM B8 56 ÷ 280 IM 2031 IM V36 56 ÷ 355


or IM 2131

IM 2001 IM B35 56 ÷ 500 IM 3011 IM V1 56 ÷ 500

IM 2101 IM B34 56 ÷ 132 IM 3031 IM V3 56 ÷ 280

56 ÷ 315
IM 3001 IM B5 without 3VTB 315 M6B,C,D IM 3611 IM V18 56 ÷ 180
without VTB 315 M8C,D

IM 3601 IM B14 56 ÷ 132 IM 3631 IM V19 56 ÷ 180

* Other mounting arrangements available on special request

10
General Purpose 3-phase Induction Motors
PERMISSIBLE LOADS ON THE SHAFT END
Frame Number Horizontal Vertical Frame Number Horizontal Vertical
size of poles operation operation size of poles operation operation

Fp Fp
FR X FR X

Fa2 Fa2

Xmax X0 Xmax X0
Fa1 Fa1

FR(x = 0) FR(x = max) Fp Fa1 Fa2 FR(x = 0) FR(x = max) Fp Fa1 Fa2
[kN] [kN] [kN] [kN]

VTB 56 2 0,20 0,16 0,04 0,03 0,05 3VTB 200 LA 2 2,91 2,44 2,24 1,72 2,92
VTB 56 4 0,25 0,20 0,05 0,04 0,06 3VTB 200 LB 2 2,85 2,39 2,23 1,67 2,93
VTB 56 6 0,25 0,20 0,06 0,05 0,07 3VTB 200 L 4 3,61 3,03 2,81 2,12 3,70
VTB 63 2 0,20 0,16 0,04 0,04 0,06 3VTB 200 LA 6 4,31 3,62 3,62 2,92 4,56
VTB 63 4 0,25 0,20 0,06 0,05 0,07 3VTB 200 LB 6 4,06 3,40 3,54 2,71 4,65
VTB 63 6 0,27 0,22 0,06 0,05 0,07 3VTB 225 S 4 4,18 3,40 3,19 2,42 4,16
VTB 63 8 0,27 0,22 0,07 0,06 0,08 3VTB 225 M 2 3,31 2,81 2,53 1,93 3,29
VTB 71 2 0,29 0,24 0,07 0,05 0,09 3VTB 225 M 4 3,97 3,23 3,13 2,26 4,24
VTB 71 4 0,36 0,30 0,09 0,07 0,11 3VTB 225 M 6 4,57 3,72 3,98 2,95 5,33
VTB 71 6 0,40 0,35 0,10 0,08 0,12 3VTB 250 M 2 4,09 3,39 3,11 2,33 4,13
VTB 71 8 0,40 0,35 0,11 0,09 0,13 3VTB 250 M 4 4,90 4,06 3,85 2,68 5,36
3VTB 80 2 0,33 0,27 0,09 0,06 0,12 3VTB 250 M 6 5,92 4,90 4,99 3,81 6,55
3VTB 80 4 0,44 0,37 0,12 0,09 0,15 3VTB 280 S 2 3,94 3,34 3,07 2,01 4,43
VTB 80 6 0,51 0,42 0,14 0,11 0,17 3VTB 280 S 4 6,69 5,67 5,01 3,65 6,77
VTB 80 8 0,51 0,42 0,17 0,15 0,20 3VTB 280 S 6 7,86 6,67 5,79 4,32 7,70
3VTB 90 2 0,68 0,44 0,68 0,35 0,38 3VTB 280 M 2 3,80 3,22 3,03 1,89 4,49
3VTB 90 4 0,78 0,44 0,78 0,35 0,38 3VTB 280 M 4 6,15 5,22 4,86 3,16 7,04
3VTB 90 6 0,96 0,44 0,96 0,35 0,38 3VTB 280 M 6 7,69 6,52 5,75 4,19 7,75
3VTB 100 2 0,88 0,46 0,90 0,28 0,40 3VTB 315 S 2 3,56 3,08 2,96 1,63 4,69
3VTB 100 4 1,06 0,46 0,98 0,38 0,40 3VTB 315 S 4 5,75 4,82 4,74 2,71 7,37
3VTB 100 6 1,20 0,46 1,10 0,38 0,40 3VTB 315 S 6 7,21 6,04 5,61 3,84 8,14
3VTB 112 2 1,00 0,48 1,00 0,40 0,45 3VTB 315 MA 2 3,07 2,65 2,82 1,23 4,89
3VTB 112 4 1,45 0,48 1,40 0,40 0,45 3VTB 315 MB 2 2,67 2,31 2,71 0,91 5,05
3VTB 112 6 1,62 0,48 1,60 0,40 0,45 3VTB 315 MA 4 5,40 4,52 4,64 2,41 7,53
3VTB 132 2 1,82 0,66 1,90 0,43 0,60 3VTB 315 MB 4 5,16 4,33 4,58 2,20 7,64
3VTB 132 4 2,10 0,66 2,20 0,45 0,60 3VTB 315 MA 6 6,75 5,66 5,48 3,22 8,40
3VTB 132 6 2,80 0,66 2,80 0,50 0,60 3VTB 315 MB 6 6,27 5,33 5,34 2,68 8,78
3VTB 160 2 2,22 0,98 2,30 0,92 0,95 3VTB 315 MC 2 2,84 2,48 2,71 0,63 5,37
3VTB 160 4 2,40 0,98 2,40 0,92 0,95 3VTB 315 MC 4 6,27 5,33 4,34 1,46 8,06
3VTB 160 6 2,85 1,10 2,90 0,98 1,00 3VTB 315 MC 6 7,57 6,44 5,08 1,87 9,23
3VTB 180 2 2,92 1,30 3,00 1,10 1,20 3VTB 315 MD 6 7,47 6,36 5,05 1,82 9,22
3VTB 180 4 3,60 1,30 3,60 1,10 1,30
3VTB 180 6 4,00 1,80 4,10 1,40 1,70

PERMISSIBLE LOADS ON THE SHAFT END for motors VTB (2p = 8 ÷ 12)
FR(x = 0) FR(x = max) Fp Fa1 Fa2 FR(x = 0) FR(x = max) Fp Fa1 Fa2
[kN] [kN] [kN] [kN]

VTB 200L8 8 5,10 4,20 4,10 3,40 5,00 VTB 280S8 8 8,30 6,90 6,60 5,20 8,50
VTB 200L10A 10 5,50 4,60 4,20 3,50 5,10 VTB 280S10 10 9,30 7,70 6,70 5,40 8,40
VTB 200L10B 10 5,50 4,50 4,10 3,40 5,10 VTB 280S12 12 9,80 8,10 7,00 5,70 8,70
VTB 200L12 12 5,90 4,90 4,40 3,70 5,40 VTB 280M8 8 8,00 6,60 6,50 4,90 8,60
VTB 225S8 8 5,90 4,70 4,70 3,90 5,70 VTB 280M10 10 8,80 7,30 6,50 5,20 8,20
VTB 225S10 10 6,50 5,10 4,70 4,00 5,60 VTB 280M12 12 9,20 7,60 6,80 5,00 9,30
VTB 225S12 12 6,70 5,30 4,80 4,20 6,00 VTB 315S8 8 8,40 7,00 7,00 5,00 9,60
VTB 225M8 8 5,70 4,60 4,60 3,70 5,80 VTB 315S10 10 9,30 7,70 7,60 5,60 10,20
VTB 225M10 10 6,30 4,90 5,70 4,40 7,40 VTB 315S12 12 9,80 8,10 8,00 5,90 10,80
VTB 225M12 12 6,70 5,30 4,90 3,90 6,20 VTB 315M8A 8 8,20 6,80 6,90 4,80 9,70
VTB 250M8 8 6,90 5,60 5,60 4,30 7,20 VTB 315M8B 8 7,70 6,40 6,80 4,30 10,00
VTB 250M10 10 7,50 6,20 5,70 4,40 7,40 VTB 315M10 10 8,40 7,00 7,30 4,80 10,70
VTB 250M12 12 8,10 6,70 6,10 4,80 7,80 VTB 315M12A 12 9,30 7,70 7,90 5,50 11,10
VTB 315M12B 12 9,10 7,60 7,80 5,30 11,20

11
General Purpose 3-phase Induction Motors

VERSION WITH ROLLER BEARINGS for motors 355

Mechanical Size Type of construction No. of poles, 2p D.E. bearing N.D.E. bearing

3VTB 355 ML IM1001 (B3) 4÷6 NU222 EM1C3 6222 C3


3VTB 355 H IM1001 (B3) 4÷6 NU322 EM1C3 6322 C3

Horizontal mounting
Permissible radial forces Permissible axial forces
FX0 FXmax FA
Motor type Number of poles Length of shaft extension E(mm) kN kN kN

3VTB 355 ML 4 210 22 18 5


6 210 23 15 5,5

3VTB 355 H 4 210 27 17 6


6 210 29 15 7

VERSION WITH ROLLER BEARINGS for motors VTB355-500


Mechanical Size Type of construction No. of poles, 2p D.E. bearing N.D.E. bearing
VTB 355 IM1001 (B3) 8 NU222 EM1C3 6222 C3
VTB 355..s IM1001 (B3) 4÷8 NU322 EM1C3 6322 C3
VTB 400..s IM1001 (B3) 4 ÷ 10 on request on request
VTB 450..s IM1001 (B3) 4 ÷ 12 on request on request
VTB 500..s IM1001 (B3) 4 ÷ 10 on request on request

Horizontal mounting Vertical operation


Permissible radial forces Permissible axial forces
FX0 FXmax FA
Motor type Number of poles Length of shaft extension E(mm) kN kN kN

VTB 355 8 210 24 14 6 on request

VTB 355..s 4 210 27 17 6 on request


8 210 30 15 8 on request

VTB 400
VTB 450 4÷8 on request
VTB 500

PERMISSIBLE LOADS ON THE SHAFT END


Value of radial force FR acting on the shaft end for a Value of force FR acting on any point of the shaft end
given belt pulley diameter is calculated according to (between points X=max and X=0) may be calculated
the following formula: according to the following formula:

where: P - motor output [kW] where: FX0 - value of FR force acting on the beginning of the shaft end
DK - belt pulley diameter [m] FXMAX - value of FR force acting on the end of the shaft end
n - speed [rpm] E - lenght of the shaft end
k - belt tension factor:
for V-belts k=2,2
for flat belts k=3

12
General Purpose 3-phase Induction Motors

Other specifications dependent on the frame size:

lubrication on the
rotation of the
cable outlets

protection of
Temperature
terminal box
the terminal
Position of

Number of

Number of

sensors in
protection
Degree of

terminals

bearings
Optional

Thermal
winding

Bearing
Glands
Frame
size

box

run
56 IP 55 top 6 1 180° M 20 on request no no
63 IP 55 top 6 1 180° M 20 on request no no
71 IP 55 top 6 1 180° M 20 on request no no
80 IP 55 top 6 1 180° M 20 on request no no
90 IP 55 top 6 2 180° M 20 on request no no
100 IP 55 top 6 2 180° M 20 on request no no
112 IP 55 top 6 2 180° M 25 on request no no
132 IP 55 top 6 2 180° M 25 on request no no
160 IP 55 top 6 2 180° M 40 on request on request on request
180 IP 55 top 6 2 180° M 40 on request on request on request
200 IP 55 top * 6 2 4 × 90° M 50 PTC yes on request
225 IP 55 top * 6 2 4 × 90° M 50 PTC yes on request
250 IP 55 top * 6 2 4 × 90° M 63 PTC yes on request
280 IP 55 top * 6 2 4 × 90° M 63 PTC yes on request
315 IP 55 top * 6 2 4 × 90° M 76 PTC yes on request
355ML IP 55 top 6 2 4 × 90° M 76 PTC Mark A yes on request
355H IP 55 top 6 2 4 × 90° M 90 Pt 100 yes Pt 100
400 IP 55 top 6 (bars) 3 180° 3×f55 Pt 100 yes Pt 100
450 IP 55 top 3 (bars) 3 180° 3×f55 Pt 100 yes Pt 100
500 IP 55 top 3 (bars) 3 180° 3×f55 Pt 100 yes Pt 100
* terminal box on right side for VTB 200-315 motors series

BEARINGS
Frame Number Bearings Frame Type of No. of D.E. N.D.E.
The bearings in basic version of motors for horizontal and verical duty,

size of poles Size construction poles, 2p bearing bearing

for horizontal and verical duty.


VTB 56 2÷6 6201 2Z
3VTB 355 ML IM1001 (B3) 2 6217 C3 6217 C3
VTB 63 2÷8 6202 2Z
VTB 71 2÷8 6203 2Z 3VTB 355 ML IM2001 (B35) 4÷6 6222 C3 6222 C3

The bearings in basic


3VTB 80 2÷6 6204 2Z C3 3VTB 355 ML IM3011 (V1) 4÷6 6322 C3 6322 C3

version of motors
3VTB 90 2÷6 6205 2Z C3
3VTB 355 H IM1001 (B3) 2 6217 C3 6217 C3
3VTB 100 2÷6 6206 2Z C3
3VTB 112 2÷6 6306 2Z C3 3VTB 355 H IM2001 (B35) 4÷6 6322 C3 6322 C3
3VTB 132 2÷6 6308 2Z C3
3VTB 355 H IM3011 (V1) 4÷6 6322 C3 6322 C3
3VTB 160 2÷6 6309 2Z C3
3VTB 180 2÷6 6311 2Z C3
3VTB 200 2÷6 6312 C3 Frame Type of No. of D.E. N.D.E.
excluding 3VTB 315 with 2p=2.

3VTB 225 2÷6 6313 C3


Size construction poles, 2p bearing bearing
3VTB 250 2÷6 6315 C3
VTB 355 IM1001 (B3) 8 6222 C3 6222 C3
3VTB 280 2 6315 C3
3VTB 280 4÷6 6318 C3 VTB 355 IM2001 (B35) 8 6222 C3 6222 C3
3VTB 315S,MA,MB 2 6315 C3 VTB 355 IM3011 (V1) 8 6322 C3 6322 C3
3VTB 315MC 2 6316 C3 VTB 355..s IM1001 (B3) 2 6217 C3 6217 C3
3VTB 315S,MA,MB 4÷6 6318 C3 VTB 355..s IM2001 (B35) 4÷8 6322 C3 6322 C3
3VTB 315MC,MD 4÷6 6320 C3/6318 C3
VTB 355..s IM3001 (V1) 4÷8 6322 C3 6322 C3
VTB 400..s IM1001 (B3) 2
VTB 400..s IM2001 (B35) 4 ÷ 10
BEARINGS for 2Sg (2p = 8 ÷ 12) VTB 400..s IM3011 (V1) 4 ÷ 10
Frame Number Bearings VTB 450..s IM1001 (B3) 4 ÷ 12
size of poles
VTB 450..s IM2001 (B35) 4 ÷ 12 on request
VTB 200 8 ÷ 12 6312 C3
VTB 450..s IM3011 (V1) 4 ÷ 12
VTB 225 8 ÷ 12 6313 C3
VTB 250 8 ÷ 12 6315 C3 VTB 500..s IM1001 (B3) 4 ÷ 10

VTB 280 8 ÷ 12 6317 C3 VTB 500..s IM2001 (B35) 4 ÷ 10


VTB 315 8 ÷ 12 6318 C3 VTB 500..s IM3011 (V1) 4 ÷ 10

13
General Purpose 3-phase Induction Motors

HOUSING, END SHIELDS, FEET


Frame Motor End Feet
size [mm] housing shields

56 Aluminium Aluminium Aluminium - screwed


63 Aluminium Aluminium Aluminium - screwed
71 Aluminium Aluminium Aluminium - screwed
3VTB 80 Aluminium Aluminium Aluminium - screwed
3VTB 90 Aluminium Aluminium Aluminium - screwed
3 VTB100 Aluminium Aluminium Aluminium - screwed
3VTB 112 Aluminium Cast iron Aluminium - screwed
3VTB 132 Aluminium / cast iron Cast iron Aluminium - screwed
3VTB 160 Cast iron Cast iron Cast iron - screwed or integrated
3VTB 180 Cast iron Cast iron Cast iron - screwed or integrated
3VTB 200 Cast iron Cast iron Cast iron - screwed or integrated
3VTB 225 Cast iron Cast iron Cast iron - screwed or integrated
3VTB 250 Cast iron Cast iron Cast iron - screwed or integrated
3VTB 280 Cast iron Cast iron Cast iron - screwed or integrated
3VTB 315 Cast iron Cast iron Cast iron - screwed or integrated
355 Cast iron Cast iron Cast iron - integrated
400 Cast iron Cast iron Cast iron - integrated
450 Cast iron Cast iron Cast iron - integrated
500 Cast iron Cast iron Cast iron - integrated

In motors series VTB of frame size 80, 90 and 100mm: on request end shields may be made of cast iron.
In motors series 3VTB of frame size 80 and 90mm: on request end shields may be made of cast iron.
In motors of frame size 132: feet may be integrated with housing.

Motor housing
aluminium
aluminium cast iron

80 90 100 112 132

cast iron

132 160 180 200 225 250 280 315 355

400 450 500

14
General Purpose 3-phase Induction Motors

DESCRIPTION OF THE CATALOGUE VERSION

3VTB 315 M 4 B
VTB 315 M 8 B

A=Lower power
B=Higher power
C,D=Increased Power

No. of poles
(Speed)
Frame
length
L=long
M=medium
S=short

Shaft h
(in B3)

3VTB-VTB 3VTB-VTB 3VTB-VTB


feet mounting flange mounting feet-flange mounting

ORDERING INFORMATION
Orders for motors should specify: When ordering high-power or special purpose motors one
should also indicate:

motor type designation, required direction of rotation,


rated output, required degree of interior protection,
rated speed, method of start-up,
operating duty, method of coupling with the driven unit (gears,
dimensions of belt pulleys, etc.),
supply voltage and connection,
type of machine driven (nature of load), including the
frequency,
moment of inertia J or flywheel effect GD2 brought to the
mounting arrangements, end shield material, motor shaft,
degree of protection, other customer’s specifications.
type of driven machine,
other details regarding special requests, When ordering spare parts one should specify:

and information concerning additional accessories e.g. full designation of the motor type including its serial
number (provided on the nameplate) or catalogue number,
degree of protection,
thermal protection,
mounting arrangement,
anticondensation heaters,
name of part,
vibration sensors,
number of pieces.
etc.

As part of our development program, we reserve the right


to alter or amend any of the specifications without giving prior notice

15
General Purpose 3-phase Induction Motors

Totally Enclosed Motors IP 55

rotor current

Breakdown
rotor torque

Moment of
Efficiency

Locked
current

Weight
Locked
output

torque

torque
Power

Inertia
speed
Rated

Rated

Rated

factor
Type
Item

load
Full
PN nN TN hN [%] cos jN IN at rated voltage [A] TL/TN IL/IN TB/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] 230V 380V 400V [-] [-] [-] [kgm2] [kg]

2p=2 ns=3000 rpm f=50Hz


1 VTB 56-2A 0,09 0,12 2820 0,30 45 52 62 0,63 0,60 0,35 0,35 2,5 3,4 2,7 0,000076 2,9
2 VTB 56-2B 0,12 0,17 2800 0,41 50 58 65 0,70 0,65 0,38 0,38 2,0 3,0 2,0 0,000095 3,2
3 VTB 63-2A 0,18 0,25 2760 0,62 63 68 70 0,77 0,85 0,50 0,50 2,1 3,4 2,1 0,000175 3,5
4 VTB 63-2B 0,25 0,33 2780 0,85 66 69 72 0,78 1,1 0,65 0,65 2,4 4,0 2,5 0,000235 4,1
5 VTB 71-2A 0,37 0,50 2800 1,25 67 69 71 0,77 1,75 1,0 1,0 2,2 4,4 2,2 0,000389 5,0
6 VTB 71-2B 0,55 0,75 2790 1,88 69 72 75 0,82 2,35 1,35 1,35 2,0 4,0 2,1 0,000484 6,0
7 3VTB 80-2A 0,75 1 2850 2,5 79,0 82,0 82,0 0,82 2,85 1,65 1,65 3,8 6,3 3,8 0,00100 10,6 IE3
8 3VTB 80-2B 1,1 1,5 2840 3,7 82,0 83,0 83,0 0,86 3,8 2,2 2,2 3,7 6,9 3,8 0,00142 11,9 IE3
9 3VTB 90S2 1,5 2 2925 4,9 82,7 84,4 84,2 0,85 5,3 3,2 3,0 2,4 8,1 2,9 0,0014 16,5 IE3
10 3VTB 90L2 2,2 3 2910 7,2 85,4 86,5 85,9 0,86 7,5 4,5 4,3 2,7 8,0 4,0 0,0019 18,5 IE3
11 3VTB 100L2 3 4 2915 9,8 86,9 87,7 87,1 0,85 10,2 6,2 5,8 3,1 9,3 4,1 0,0039 25,0I IE3
12 3VTB 112M2 4 5,5 2925 13 88,0 88,5 88,1 0,89 12,8 7,8 7,4 2,3 8,4 3,2 0,0075 35,5 IE3
13 3VTB 132S2A 5,5 7,5 2940 17,9 87,7 89,2 89,2 0,89 17,4 10,5 10,0 2,6 8,2 3,4 0,014 55,0 IE3
14 3VTB 132S2B 7,5 10 2940 24,4 89,0 90,3 90,1 0,90 23,2 14,1 13,3 2,8 8,5 3,8 0,017 64,0 IE3
15 3VTB 160M2A 11 15 2945 35,7 89,7 91,0 91,2 0,90 33,6 20,4 19,2 2,2 7,3 3,2 0,048 123 IE3
16 3VTB 160M2B 15 20 2945 48,6 89,8 91,9 91,9 0,90 45,5 27,6 26,2 2,2 7,4 3,3 0,059 132 IE3
17 3VTB 160L2 18,5 25 2940 60,1 92,2 92,8 92,4 0,90 55,8 33,8 32,1 2,3 7,7 3,0 0,072 139 IE3
18 3VTB 180M2 22 30 2955 71,1 92,1 92,9 92,7 0,90 66,2 40,1 38,1 3,2 9,2 3,7 0,095 190 IE3
19 3VTB 200L2A 30 40 2965 97 93,1 93,7 93,5 0,90 89 54 51 2,4 7,0 2,8 0,19 275 IE3
20 3VTB 200L2B 37 50 2955 120 93,5 93,8 93,7 0,90 110 67 63 2,2 6,3 2,6 0,20 295 IE3
21 3VTB 225M2 45 60 2972 145 94,2 94,6 94,2 0,88 136 82 78 2,0 6,7 2,6 0,26 385 IE3
22 3VTB 250M2 55 75 2969 177 94,5 94,8 94,5 0,91 161 97 92 2,2 6,9 2,9 0,42 495 IE3
23 3VTB 280S2 75 100 2978 241 94,2 94,8 94,7 0,91 218 132 126 1,8 6,7 2,9 0,76 660 IE3
24 3VTB 280M2 90 125 2979 289 94,5 95,1 95,0 0,91 261 158 150 1,8 7,3 3,1 0,95 690 IE3
25 3VTB 315S2 110 150 2978 353 95,4 95,6 95,2 0,92 315 191 181 1,9 6,9 2,9 0,98 865 IE3
26 3VTB 315M2A 132 175 2977 423 95,8 95,9 95,6 0,92 377 238 217 2,0 7,3 2,7 1,28 970 IE3
27 3VTB 315M2B 160 220 2978 513 95,9 96,1 95,8 0,92 456 276 262 2,2 8,2 3,1 1,57 1118 IE3
28 3VTB 315M2C 200 270 2980 641 95,9 96,1 95,8 0,93 - 341 324 2,3 8,1 3,1 1,74 1185 IE3
29 3VTB 355 ML2A 250 340 2982 801 94,8 95,7 95,8 0,91 - 414 239 1,9 6,8 2,8 2,80 1620 IE3
30 3VTB 355 ML2B 315 430 2982 1009 95,5 96,1 96,2 0,91 - 519 300 2,0 7,3 2,9 3,00 1700 IE3
31 3VTB 355 H2D 355 480 2985 1136 95,2 96,0 96,2 0,91 - 585 338 1,8 7,5 2,8 4,90 2160 IE3
32 VTB 355H2Es 400 540 2985 1280 95,5 96,6 96,7 0,91 - - 656 1,6 8,0 2,8 5,7 2160
33 VTB 400H2Cs 450 610 2983 1441 95,5 96,3 96,5 0,91 - - 741 1,3 6,6 2,6 6,7 2800
34 VTB 400H2Ds 500 680 2985 1600 95,8 96,5 96,6 0,91 - - 821 1,4 7,2 2,8 7,7 2800
35 VTB 400H2Es 560 760 2989 1789 95,9 96,7 96,9 0,90 - - 927 1,7 8,0 3,0 8,7 3100
36 VTB 400H2Es 600 816 2987 1918 96,0 96,8 97,0 0,91 - - 981 1,7 8,0 3,0 8,7 3100

* insulation class F/F

16
General Purpose 3-phase Induction Motors
Totally Enclosed Motors IP 55

rotor current

Breakdown
rotor torque

Moment of
Efficiency

Locked
current

Weight
Locked
output

torque

torque
Power

Inertia
speed
Rated

Rated

Rated

factor
Type
Item

load
Full
PN nN TN hN [%] cos jN IN at rated voltage [A] TL/TN IL/IN TB/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] 230V 380V 400V [-] [-] [-] [kgm2] [kg]

2p=4 ns=1500 rpm f=50Hz


37 VTB 56-4A 0,06 0,08 1400 0,41 40,0 48,0 50,0 0,58 0,52 0,30 0,30 2,0 2,8 2,3 0,00015 2,6
38 VTB 56-4B 0,09 0,12 1400 0,61 54,0 58,0 58,0 0,60 0,70 0,40 0,40 2,1 2,6 2,3 0,00019 2,8
39 VTB 63-4A 0,12 0,17 1380 0,83 56,0 60,0 60,0 0,63 0,80 0,45 0,45 1,9 2,6 2,0 0,00024 3,5
40 VTB 63-4B 0,18 0,25 1340 1,52 52,0 55,0 57,0 0,66 1,2 0,70 0,70 2,0 2,6 2,0 0,00031 4,1
41 VTB 71-4A 0,25 0,33 1380 1,73 60,0 63,0 66,0 0,64 1,5 0,85 0,85 2,0 3,0 2,0 0,00061 5,1
42 VTB 71-4B 0,37 0,50 1370 2,6 64,0 67,0 70,0 0,68 2,2 125 1,25 2,0 3,1 2,1 0,00077 5,8
43 VTB 80-4A 0,55 0,75 1400 3,75 70,0 69,0 73,0 0,69 2,8 1,6 1,6 2,1 3,6 2,1 0,00158 7,5
IE3 44 3VTB 80-4B 0,75 1 1430 5,0 81,5 82,0 82,5 0,64 3,6 2,1 2,1 3,8 5,7 3,8 0,00265 11,0
IE3 45 3VTB 90S4 1,1 1,5 1450 7,2 81,8 84,0 84,1 0,77 4,3 2,6 2,5 2,5 7,6 3,1 0,0036 18,0
IE3 46 3VTB 90L4 1,5 2 1450 9,9 83,9 85,5 85,3 0,78 5,7 3,4 3,3 2,6 8,0 3,2 0,0040 21,0
IE3 47 3VTB 100L4A 2,2 3 1460 14,4 85,0 86,8 86,7 0,79 8,1 4,9 4,6 2,3 7,5 2,9 0,0076 27,5
IE3 48 3VTB 100L4B 3 4 1460 19,6 85,8 87,7 87,7 0,77 11,2 6,7 6,4 2,5 7,8 3,0 0,0086 31,0
IE3 49 3VTB 112M4 4 5,5 1460 26,2 88,5 89,0 88,6 0,80 14,2 8,6 8,1 2,1 7,1 3,1 0,0115 41,5
IE3 50 3VTB 132S4 5,5 7,5 1465 35,7 88,6 89,8 89,6 0,85 18,1 11,0 10,4 2,5 8,5 3,3 0,036 63,0
IE3 51 3VTB 132M4 7,5 10 1465 49,1 89,7 90,6 90,4 0,83 25,1 15,2 14,4 2,9 8,8 3,8 0,042 67,0
IE3 52 3VTB 160M4 11 15 1470 71,5 89,8 91,3 91,4 0,83 36,4 22,0 20,9 2,3 7,3 2,8 0,088 136
IE3 53 3VTB 160L4 15 20 1475 97,1 90,8 92,1 92,1 0,83 49,3 29,8 28,3 2,8 8,1 3,2 0,104 154
IE3 54 3VTB 180M4 18,5 25 1475 120,2 92,1 92,8 92,6 0,85 59,0 35,7 33,9 2,6 7,9 3,0 0,162 190
IE3 55 3VTB 180L4 22 30 1475 142,4 91,4 92,8 93,0 0,83 71,5 43,3 41,1 3,2 8,4 3,4 0,185 200
IE3 56 3VTB 200L4 30 40 1477 194 94,2 94,3 93,8 0,89 90 55 52 2,1 6,4 2,6 0,38 329
IE3 57 3VTB 225S4 37 50 1485 238 94,1 94,4 94,0 0,87 114 69 65 2,0 6,9 2,8 0,51 373
IE3 58 3VTB 225M4 45 60 1483 290 94,4 94,8 94,3 0,88 136 82 78 2,1 7,1 2,7 0,59 410
IE3 59 3VTB 250M4 55 75 1487 353 94,0 94,8 94,7 0,90 162 98 93 2,5 7,6 2,9 1,00 520
IE3 60 3VTB 280S4 75 100 1488 481 93,9 95,0 95,0 0,91 218 132 125 2,0 6,8 2,5 1,37 710
IE3 61 3VTB 280M4 90 125 1491 576 94,9 95,5 95,4 0,89 266 161 153 2,6 8,4 3,0 1,80 761
IE3 62 3VTB 315S4 110 150 1488 706 95,1 95,5 95,4 0,90 322 195 185 2,0 6,6 2,4 2,25 920
IE3 63 3VTB 315M4A 132 175 1489 847 95,6 95,9 95,6 0,91 381 231 219 2,3 7,9 2,8 2,59 1030
IE3 64 3VTB 315M4B 160 220 1490 1026 95,9 96,1 95,8 0,90 466 282 268 2,4 8,5 3,1 2,80 1130
IE3 65 3VTB 315M4C 200 270 1488 1284 95,8 96,2 96,2 0,90 - 351 333 2,4 8,1 2,9 3,46 1205
IE3 66 3VTB 355 ML4A 250 340 1489 1603 95,6 96,1 96,1 0,89 - 422 244 2,0 7,4 2,3 5,30 1700
IE3 67 3VTB 355 ML4B 315 430 1489 2020 96,0 96,4 96,3 0,90 - 525 303 2,3 7,5 2,5 6,40 1830
IE3 68 3VTB 355 H4D 355 480 1488 2278 96,1 96,4 96,3 0,88 - 605 349 1,7 6,4 2,2 7,80 2200
69 VTB 355H4Es 400 540 1489 2566 96,4 96,8 96,7 0,88 - 715 678 1,8 7,0 2,3 8,7 2275
70 VTB 400H4Cs 450 610 1490 2884 96,3 96,9 96,9 0,88 - 796 762 1,6 7,6 2,6 12,3 2920
71 VTB 400H4Ds 500 680 1491 3203 96,2 96,7 96,7 0,88 - 891 848 1,6 7,5 2,6 13,6 3100
72 VTB 400H4Es 560 760 1491 3587 96,6 97,0 97,0 0,87 - 987 958 1,7 7,6 2,6 15,0 3220
73 VTB 400H4Fs 630 850 1491 4035 96,7 97,1 97,1 0,87 - 1114 1076 1,9 8,4 2,8 16,5 3440
74 VTB 450H4Bs 710 960 1492 4545 96,6 97,1 97,1 0,88 - - 6962 1,6 7,0 2,5 27,1 4000
75 VTB 450H4Cs 800 1080 1494 5114 96,8 97,1 97,1 0,89 - - 7742 1,6 6,8 2,6 31,6 4400
76 VTB 450H4Ds 900 1210 1493 6757 96,8 97,2 97,2 0,88 - - 8812 1,0 7,3 2,5 35,4 4620
77 VTB 450H4Es 1000 1350 1493 6397 96,8 97,3 97,3 0,89 - - 9662 1,5 7,3 2,5 38,0 4700
78 VTB 500H4Cs 1120 1510 1495 7155 96,7 97,4 97,4 0,87 - - 11072 0,8 6,9 2,5 58,4 6100
79 VTB 500H4Ds 1250 1680 1495 7985 96,7 97,4 97,5 0,87 - - 12342 0,8 7,5 2,7 65,2 6600
80 VTB 500H4Es 1400 1880 1494 8949 96,9 97,5 97,5 0,88 - - 13672 0,7 6,4 2,4 66,5 6900

2 - at rated voltage 690V

17
General Purpose 3-phase Induction Motors

Totally Enclosed Motors IP 55

rotor current
rotor torque

Breakdown

Moment of
Efficiency

Locked
current

Weight
Locked
output

torque

torque

Inertia
Power
speed
Rated

Rated

Rated

factor
Type
Item

load
Full
PN nN TN hN [%] cos jN IN at rated voltage [A] TL/TN IL/IN TB/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] 230V 380V 400V [-] [-] [-] [kgm2] [kg]

2p=6 ns=1000 rpm f=50Hz

81 VTB 56-6B 0,06 0,08 870 0,64 44 46 50 0,65 1,1 0,65 0,65 1,3 1,8 1,5 0,00019 2,8
82 VTB 63-6A 0,09 0,12 820 1,05 26 32 40 0,75 0,8 0,45 0,45 1,15 1,9 1,3 0,00024 3,5
83 VTB 63-6B 0,12 0,17 870 1,30 38 44 50 0,65 1,15 0,65 0,65 1,3 1,8 1,1 0,00031 4,1
84 VTB 71-6A 0,18 0,25 890 1,93 47 54 57 0,68 1,3 0,75 0,75 1,9 2,6 1,9 0,00074 4,8
85 VTB 71-6B 0,25 0,33 860 2,78 45 52 55 0,79 1,75 1,0 1,0 1,6 2,0 1,6 0,00095 5,6
86 VTB 80-6A 0,37 0,50 910 3,88 61 63 64 0,65 2,4 1,4 1,4 2,0 3,0 2,1 0,00169 7,4
87 VTB 80-6B 0,55 0,75 900 5,84 62 65 67 0,70 3,1 1,8 1,8 1,9 2,7 2,0 0,00207 8,7
88 3VTB 90S6 0,75 1 940 7,6 77,2 79,3 78,9 0,71 3,4 2,0 1,9 2,1 4,5 2,6 0,0032 16 IE3
89 3VTB 90L6 1,1 1,5 940 11,1 79,9 81,9 81,0 0,70 4,9 2,9 2,8 2,1 4,5 2,6 0,0090 19 IE3
90 3VTB 100L6 1,5 2 960 14,9 81,1 82,8 82,5 0,74 6,2 3,7 3,5 2,6 6,2 3,3 0,0100 23,5 IE3
91 3VTB 112M6 2,2 3 960 21,9 83,9 84,9 84,3 0,76 8,6 5,2 5,0 2,1 5,9 2,6 0,0177 34 IE3
92 3VTB 132S6 3 4 965 29,7 85,0 87,2 87,0 0,81 10,7 6,5 6,1 2,2 6,6 2,9 0,0440 54 IE3
93 3VTB 132M6A 4 5,5 965 39,8 89,1 89,2 88,0 0,81 14,1 8,5 8,1 2,3 6,6 3,0 0,0579 62 IE3
94 3VTB 132M6B 5,5 7,5 960 54,7 88,9 89,1 88,0 0,81 19,4 11,7 11,1 2,4 6,7 3,1 0,0637 66 IE3
95 3VTB 160M6 7,5 10 970 73,8 89,0 89,9 89,5 0,82 25,7 15,5 14,8 2,1 6,8 2,9 0,1020 134 IE3
96 3VTB 160L6 11 15 970 108,3 89,6 90,5 90,3 0,82 37,3 22,6 21,4 2,2 7,0 3,0 0,1230 146 IE3
97 3VTB 180L6 15 20 980 146,2 90,0 91,3 91,2 0,81 60,0 30,9 29,3 3,3 7,3 2,8 0,2760 198 IE3
98 3VTB 200L6A 18,5 25 988 179 91,3 92,0 91,7 0,81 63 38 36 2,0 5,8 2,4 0,50 285 IE3
99 3VTB 200L6B 22 30 987 213 91,7 92,2 92,2 0,82 73 44 42 2,0 5,7 2,1 0,64 309 IE3
100 3VTB 225M6 30 40 989 290 92,3 92,9 92,9 0,83 98 53 55 1,9 6,4 2,3 0,89 392 IE3
101 3VTB 250M6 37 50 991 357 92,2 93,4 93,3 0,82 121 73 70 2,0 6,7 2,6 1,23 440 IE3
102 3VTB 280S6 45 60 993 433 92,9 93,8 93,7 0,81 149 90 86 2,3 7,3 2,6 1,70 635 IE3
103 3VTB 280M6 55 75 992 529 93,8 94,4 94,1 0,82 179 108 103 2,3 6,8 2,6 1,90 695 IE3
104 3VTB 315S6 75 100 992 722 94,6 95,0 94,7 0,82 242 147 139 2,4 7,1 2,6 2,40 900 IE3
105 3VTB 315M6A 90 125 993 866 95,1 95,4 95,1 0,82 290 175 167 2,6 7,6 2,7 2,93 965 IE3
106 3VTB 315M6B 110 150 992 1059 95,2 95,6 95,2 0,82 354 214 203 2,8 7,5 2,8 3,46 1110 IE3
107 3VTB 315M6C 132 175 992 1271 95,4 95,8 95,4 0,83 - 253 241 2,5 7,0 2,5 4,21 1230 IE3
108 3VTB 315M6D 160 220 992 1540 95,2 95,7 95,6 0,78 - 310 180 3,3 8,0 2,7 4,36 1235 IE3
109 3VTB 355 ML6A 200 270 989 1931 95,3 95,9 95,8 0,86 - 350 202 2,0 7,1 2,3 7,20 1740 IE3
110 3VTB 355 ML6B 250 340 990 2412 95,5 96,0 95,8 0,86 - 438 253 2,1 7,2 2,4 8,60 1950 IE3
111 3VTB 355 H6C 315 430 992 3033 96,0 96,3 96,1 0,86 - 550 318 2,0 7,1 2,2 12,70 2390 IE3
112 3VTB 355 H6D 355 480 991 3421 95,9 96,3 96,1 0,86 - 620 358 1,9 7,0 2,3 13,60 2500 IE3
113 VTB 400H6Bs 400 540 992 3851 95,6 96,3 96,3 0,84 - - 714 1,7 6,8 2,2 18,2 3050
114 VTB 400H6Cs 450 610 993 4328 95,8 96,3 96,0 0,83 - - 815 1,5 7,5 2,5 19,4 3250
115 VTB 450H6As 500 680 994 4804 96,6 96,9 96,8 0,88 - - 4912 1,2 6,7 2,6 36,5 3800
116 VTB 450H6Bs 560 760 994 5380 96,7 97,0 96,9 0,88 - - 5492 1,2 6,8 2,6 40,6 4300
117 VTB 450H6Cs 630 850 994 6053 96,7 97,1 97,0 0,89 - - 6112 1,3 7,0 2,6 45,0 4500
118 VTB 450H6Ds 710 960 994 6821 96,5 96,8 96,8 0,89 - - 6902 1,4 7,4 2,6 50,0 4890
119 VTB 500H6As 800 1080 995 7678 96,7 97,1 97,0 0,86 - - 8022 0,9 5,8 2,4 61,5 6200
120 VTB 500H6Bs 900 1210 995 8638 96,8 97,1 97,0 0,87 - - 8932 1,0 6,0 2,2 67,5 6550
121 VTB 500H6Cs 1000 1350 995 9598 96,4 97,0 97,1 0,86 - - 10022 1,0 6,4 2,5 70,0 6700
122 VTB 500H6Ds 1120 1510 996 10739 96,4 97,1 97,2 0,85 - - 11342 1,1 7,0 2,6 80,0 7130
123 VTB 500H6Es 1250 1680 996 11985 96,4 97,1 97,2 0,85 - - 12662 1,1 7,1 2,6 84,6 7460

2 - at rated voltage 690V

18
General Purpose 3-phase Induction Motors

Totally Enclosed Motors IP 55

Weight (IMB3)
rotor current
rotor torque

Breakdown

Moment of
Efficiency

Locked

Locked
current

torque
torque
output

Power

inertia
speed
Rated

Rated
Rated

factor
Type
Item

load
Full
PN nN TN hN [%] at % of full load cos jN IN at rated voltage TL/TN IL/IN Tb/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] [A]230V [A]380V [A]400V [-] [-] [-] [kgm2] [kg]

2p=8 ns=750 rpm

124 VTB 63-8A 0,04 0,05 670 0,57 20 31 35 0,60 0,6 0,35 0,35 1,6 1,7 1,7 0,00024 3,5
125 VTB 63-8B 0,06 0,08 660 0,87 20 24 28 0,48 1,1 0,65 0,65 1,4 1,5 1,6 0,000307 4,1
126 VTB 71-8A 0,09 0,12 680 1,26 25 31 35 0,5 1,3 0,75 0,75 1,9 1,9 1,9 0,000736 4,7
127 VTB 71-8B 0,12 0,17 670 1,71 40 45 47 0,63 1,25 0,7 0,7 1,7 1,9 1,8 0,000946 5,6
128 VTB 80-8A 0,18 0,25 680 2,53 43 51 53 0,57 1,55 0,9 0,9 1,8 2,3 2,0 0,001693 7,2
129 VTB 80-8B 0,25 0,33 680 3,51 52 55 57 0,6 2,1 1,2 1,2 1,7 2,5 1,7 0,00207 8,7
130 VTB 90S-8 0,37 0,5 695 5,08 54,2 60,8 63,4 0,59 2,5 1,5 1,4 1,7 2,9 2,3 0,0021 13,4
131 VTB 90L-8 0,55 0,75 675 7,78 60,4 65,3 65 0,64 3,3 2 1,9 1,7 2,8 1,9 0,0024 15,3
132 VTB 100L-8A 0,75 1 710 10,1 65,9 70,5 71,1 0,66 4 2,4 2,3 1,4 3,5 1,9 0,009 23,6
133 VTB 100L-8B 1,1 1,5 705 14,9 67,6 71,8 72,2 0,65 5,9 3,6 3,4 1,6 3,6 1,9 0,01 26,3
134 VTB 112M-8 1,5 2 720 19,9 72,5 76,2 76,8 0,71 6,9 4,2 4,0 1,9 4,6 2,3 0,0192 31
135 VTB 132S-8 2,2 3 710 29,6 75,4 78,2 78 0,74 9,6 5,8 5,5 2,0 4,7 2,4 0,033 53
136 VTB 132M-8 3 4 710 40,4 78,5 80,7 80 0,74 12,7 7,7 7,3 2,3 5,0 3,0 0,044 65
137 VTB 160M-8A 4 5,5 705 54,2 81,5 82,7 81,5 0,76 16,2 9,8 9,3 2,2 5,0 2,7 0,06 85
138 VTB 160M-8B 5,5 7,5 710 74 82,1 83,7 83 0,75 22,2 13,4 12,8 2,7 5,5 3,0 0,077 95
139 VTB 160L-8 7,5 10 705 102 84,5 85,5 84,5 0,78 28,6 17,3 16,4 2,7 5,8 3,0 0,102 115
140 VTB 180L-8 11 15 730 144 87,7 89,2 89 0,76 40,8 24,7 23,5 2,0 5,5 2,4 0,213 165
141 VTB 200L8 15 20 733 195 88,8 90 89,5 0,83 51 30,5 29,1 2,2 5,5 2,1 0,45 255
142 VTB 225S8 18,5 25 735 240 88,8 90 89,5 0,81 64 39 37 2,0 5,6 2,0 0,58 280
143 VTB 225M8 22 30 735 286 90,0 90,8 90,4 0,80 76 46 44 2,0 5,2 1,8 0,68 315
144 VTB 250M8 30 40 738 388 91,0 92 91,5 0,84 98 59 56 2,5 6,3 2,1 1,27 430
145 VTB 280S8 37 50 737 479 92,0 93,1 92,8 0,83 121 73 69 2,0 5,3 1,8 1,47 535
146 VTB 280M8 45 60 737 583 92,0 92,8 92,5 0,84 145 88 84 2,1 5,4 2,0 1,8 590
147 VTB 315S8 55 75 735 715 92,0 93,0 92,7 0,81 184 111 106 2,0 5,3 1,9 2,16 720
148 VTB 315M8A 75 100 737 972 92,5 93,5 93,2 0,82 246 149 142 2,5 6,2 1,9 2,29 750
149 VTB 315M8B 90 125 737 1166 92,5 93,5 93,2 0,82 296 179 170 2,4 6,5 1,9 2,86 840
150 VTB 315M8C1 110 150 737 1425 92,3 93,1 93,3 0,79 375 227 215 2,3 5,4 2,2 3,46 1105
151 VTB 315M8D1 132 175 734 1717 92,7 93,3 93,2 0,81 439 266 252 2,3 5,4 2,2 3,69 1136
152 VTB 355ML8A 160 220 739 2068 95,1 95,5 95,0 0,80 - - 305 1,6 5,8 2,0 7,0 1680
153 VTB 355ML8B 200 270 740 2581 95,1 95,6 95,2 0,79 - - 384 1,8 6,2 2,1 7,7 1750
154 VTB 355H8Ds 250 340 742 3218 95,5 96,0 95,6 0,78 - - 484 1,3 6,0 2,0 12,9 2440
155 VTB 355H8Es 315 430 742 4054 95,6 96,0 95,8 0,78 - - 609 1,3 6,0 2,0 16,0 2590
156 VTB 400H8Ds 355 480 742 4569 95,3 95,9 95,9 0,77 - - 695 1,2 5,8 2,0 18,8 3200
157 VTB 400H8Es 400 540 742 5148 95,4 96,0 96,0 0,77 - - 782 1,2 5,9 2,0 21,0 3350
158 VTB 450H8Bs 450 610 746 5761 95,5 96,3 96,4 0,78 - - 5012 1,0 5,8 2,1 41,6 4400
159 VTB 450H8Cs 500 680 746 6401 95,5 96,3 96,4 0,78 - - 5572 1,0 5,8 2,1 46,0 4600
160 VTB 450H8Ds 560 760 746 7169 95,6 96,4 96,5 0,78 - - 6232 1,0 5,7 2,1 49,0 4770
161 VTB 450H8Es 630 850 746 8065 95,8 96,4 96,5 0,79 - - 6922 1,0 5,6 2,0 53,8 4980
162 VTB 500H8Bs 710 960 746 9089 96,0 96,6 96,7 0,81 - - 7582 1,0 6,0 2,4 92,4 6680
163 VTB 500H8Cs 800 1080 746 10241 96,0 96,6 96,7 0,80 - - 8652 1,1 6,3 2,5 95,8 6800
164 VTB 500H8Ds 900 1210 746 11522 96,1 96,8 96,9 0,80 - - 9712 1,0 6,0 2,4 108 7240
165 VTB 500H8Es 1000 1350 746 12802 96,1 96,8 96,9 0,80 - 10792 1,1 6,5 2,5 118 7570

1 insulation class H
2 at rated voltage 690 V

19
General Purpose 3-phase Induction Motors

Totally Enclosed Motors IP 55

Weight (IMB3)
rotor current
rotor torque

Breakdown

Moment of
Efficiency

Locked

Locked
current

torque
torque
output

Power

inertia
speed
Rated

Rated
Rated

factor
Type
Item

load
Full
PN nN TN hN [%] at % of full load cos jN IN at rated voltage TL/TN IL/IN Tb/TN J
[kW] [HP] [min-1] [Nm] 50% 75% 100% [-] [A]230V [A]380V [A]400V [-] [-] [-] [kgm2] [kg]

2p=10 ns=600 rpm

166 VTB 200L10A 7,5 10 580 123 82,5 84 85 0,68 32,5 19,7 18,7 1,7 3,5 2,1 0,4 240
167 VTB 200L10B 11 15 590 178 84,7 86,7 87,5 0,68 46,5 28,1 26,7 3,2 5,9 2,4 0,47 255
168 VTB 225S10 13 18 592 210 87,5 89,3 90,5 0,67 54 32,5 31 1,8 3,8 2 0,6 280
169 VTB 225M10 15 20 590 243 86 88 89 0,67 63 38 36,5 2,8 5,4 2 0,76 315
170 VTB 225M10z 18,5 25 590 299 84,3 87,1 87,7 0,64 83 50 47,5 2,8 5,5 2,1 0,76 325
171 VTB 250M10 22 30 592 355 87,5 89,6 90 0,70 88 53 50 3 5,8 2 1,27 430
172 VTB 280S10A 30 40 586 489 85,3 87,3 88,8 0,71 119 72 69 2 4,5 1,7 1,35 525
173 VTB 280S10B 37 50 583 606 87 90 91 0,75 136 82 78 1,9 4,5 1,5 1,61 565
174 VTB 280M10 45 60 587 732 88 90,5 91,6 0,76 162 98 93 2 4,5 1,6 2,03 630
175 VTB 315S10 45 60 588 731 90 91,5 92,1 0,71 173 105 99 2 4,1 2 2,16 720
176 VTB 315S10z 55 75 583 901 88 90,5 91,5 0,75 201 122 116 1,7 4,7 1,9 2,86 840
177 VTB 315M10 75 100 583 1229 88 90,5 91,5 0,75 274 166 158 1,8 4,9 1,5 3,01 895
178 VTB 400H10As 200 270 594 3216 94,4 95,1 95,0 0,82 - - 371 1,0 5,4 2,5 25,6 3010
179 VTB 400H10Bs 250 340 594 4019 94,4 95,2 95,2 0,79 - - 480 1,1 5,6 2,6 31,3 3270
180 VTB 450H10As 315 430 594 5064 94,9 95,5 95,5 0,81 - - 3412 1,0 5,9 2,2 49,4 4050
181 VTB 450H10Bs 355 480 594 5708 95,0 95,7 95,7 0,81 - - 3842 1,0 6,0 2,3 53,9 4130
182 VTB 450H10Cs 400 540 594 6431 95,0 95,7 95,7 0,81 - - 4322 1,1 6,4 2,3 58,3 4300
183 VTB 500H10As 450 610 594 7235 95,1 95,8 95,7 0,81 - - 4862 1,4 6,3 2,1 74,1 5420
184 VTB 500H10Bs 500 680 594 8039 95,2 95,9 95,8 0,82 - - 5332 1,5 6,6 2,2 85,5 5700
185 VTB 500H10Cs 560 760 593 9019 95,4 95,9 95,8 0,82 - - 5972 1,3 6,2 2,0 94,2 5950
186 VTB 500H10Ds 630 850 594 10129 95,5 96,0 96,0 0,82 - - 6702 1,7 6,9 2,2 108 6400

2p=12 ns=500 rpm

187 VTB 200L12 9 12 490 175 75,3 80,1 81,8 0,55 50 30,5 28,9 2,7 4,3 2,5 0,47 255
188 VTB 225S12 11 15 490 214 83,1 85,0 86,0 0,63 51 31 29,3 1,7 3,5 1,7 0,58 315
189 VTB 225M12 13 18 475 261 81,5 82,2 82,5 0,59 67 40,5 38,5 1,7 3,5 1,7 0,68 320
190 VTB 225M12z 15 20 491 292 80,5 83,5 84,4 0,58 77 46,5 44 2,7 4,6 1,8 0,68 350
191 VTB 250M12 18,5 25 490 361 84,0 86,0 87,8 0,65 81 49,5 47 1,7 3,5 1,8 1,27 430
192 VTB 280S12 22 30 491 428 86,9 89,2 89,6 0,61 101 61 58 2,3 4,5 1,8 1,47 535
193 VTB 280M12 30 40 490 585 85,6 88,2 89,0 0,62 136 83 78 1,8 3,5 1,8 1,8 570
194 VTB 315S12 37 50 492 718 87,5 89,9 90,4 0,58 177 107 102 2,6 4,5 1,9 2,29 730
195 VTB 315M12A 45 60 490 877 87,9 89,0 90,1 0,58 216 131 124 2 3,5 1,8 2,86 870
196 VTB 315M12B 55 75 490 1072 87,5 90,0 89,5 0,58 266 161 153 2,5 4,4 1,8 3,01 885
197 VTB 450H12As 160 220 495 3087 94,1 95,0 95,0 0,79 - - 308 0,9 5,9 2,6 30,0 3470
198 VTB 450H12Bs 200 270 495 3859 94,7 94,9 94,9 0,80 - - 381 0,9 5,7 2,3 33,7 3600
199 VTB 450H12Cs 250 340 493 4843 94,7 95,0 94,7 0,82 - - 465 0,8 5,1 2,2 40,0 3750

2 - at rated voltage 690 V

As part of our development program, we reserve the right


to alter or amend any of the specifications without giving prior notice.

20
General Purpose 3-phase Induction Motors
Dimensions for FOOT MOUNTED MOTORS - IM B3

A-A

F
D
GA

HD
H
A

HA
E C B K AA
BB A
L AB

Motor type A B C D E F GA H K AA AB BB HA HD L

VTB 56-.A 90 71 36 9j6 20 3h9 10,2 56 5,8 30 110 92 7 154 183


VTB 56-.B 90 71 36 9j6 20 3h9 10,2 56 5,8 30 110 92 7 154 193
VTB 63-.A 100 80 40 11j6 23 4h9 12,5 63 7 36 124 106 8,5 165 200
VTB 63-.B 100 80 40 11j6 23 4h9 12,5 63 7 36 124 106 8,5 165 210
VTB 71-.A 112 90 45 14j6 30 5h9 16 71 7 45 142 116 8 182 223
VTB 71-.B 112 90 45 14j6 30 5h9 16 71 7 45 142 116 8 182 245
VTB 80-.A 125 100 50 19j6 40 6h9 21,5 80 10 55 160 130 9 200 266
VTB 80-.B 125 100 50 19j6 40 6h9 21,5 80 10 55 160 130 9 200 278
3VTB 80-.A 125 100 50 19j6 40 6h9 21,5 80 10 55 160 130 9 199 278
3VTB 80-.B 125 100 50 19j6 40 6h9 21,5 80 10 55 160 130 9 199 306
3VTB 90S-2,4,6 140 100 56 24j6 50 8h9 27 90 10 47 182 153 10 238 331
3VTB 90L-2 140 125 56 24j6 50 8h9 27 90 10 47 182 153 10 238 331
3VTB 90L-4,6 140 125 56 24j6 50 8h9 27 90 10 47 182 153 10 238 356
3VTB 100L-2,6 160 140 63 28j6 60 8h9 31 100 12 52 202 170 12 257 377
3VTB 100L-4A,4B 160 140 63 28j6 60 8h9 31 100 12 52 202 170 12 257 417
3VTB 112M-2,6 190 140 70 28j6 60 8h9 31 112 12 52 222 170 14 280 398
3VTB 112M-4 190 140 70 28j6 60 8h9 31 112 12 52 222 170 14 280 425
3VTB 132S 216 140 89 38k6 80 10h9 41 132 12 61 266 220 18 329 512
3VTB 132M 216 178 89 38k6 80 10h9 41 132 12 61 266 220 18 329 512
3VTB 160M 254 210 108 42k6 110 12h9 45 160 15 81 320 300 25 383 643
3VTB 160L 254 254 108 42k6 110 12h9 45 160 15 81 320 300 25 383 643
3VTB 180M-2,4 279 241 121 48k6 110 14h9 51,5 180 15 92 353 320 27 414 723
3VTB 180L-4,6 279 279 121 48k6 110 14h9 51,5 180 15 92 353 320 27 414 723

MOTORS series VTB 2p=8


Motor type A B C D E F GA H HA K AA AB BB HD L

VTB 90S ... 140 100 56 24j6 50 8h9 27 90 10 10 50 170 153 220 305
VTB 90L ... 140 125 56 24j6 50 8h9 27 90 10 10 50 170 153 220 330
VTB 100L ... 160 140 63 28j6 60 8h9 31 100 14 12 45 200 172 240 376
VTB 112M ... 190 140 70 28j6 60 8h9 31 112 14 12 54 230 174 276 384
VTB 132S ... 216 140 89 38k6 80 10h9 41 132 16 12 56 278 182 310 463
VTB 132S-2B 216 140 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501
VTB 132M ... 216 178 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501
VTB 160M ... 254 210 108 42k6 110 12h9 45 160 20 15 60 305 256 370 612
VTB 160L ... 254 254 108 42k6 110 12h9 45 160 20 15 60 305 300 370 656
VTB 180M ... 279 241 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705
VTB 180L ... 279 279 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705

21
General Purpose 3-phase Induction Motors

Dimensions for FOOT MOUNTED MOTORS - IM B3

HD
A

H
HA
A-A
D

BA1 BA2 AA K
F

GA E C B A
B1 AB
BB
L

Motor type A B B1 C D E F GA H HA K AA AB BA1 BA2 BB HD L

3VTB200 318 305 - 133 55 110 16 59 200 32 19 80 400 113 113 380 520 850
3VTB225S4 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 930
3VTB225M2 356 286 311 149 55 110 16 59 225 34 19 85 440 115 115 380 570 900
3VTB225M4-6 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 930
3VTB250M2 406 349 - 168 60 140 18 64 250 37 24 90 480 135 135 445 635 1010
3VTB250M4-6 406 349 - 168 65 140 18 69 250 37 24 90 480 135 135 445 635 1040
3VTB280S2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 1135
3VTB280S4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 1135
3VTB280M2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 1135
3VTB280M4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 1135
3VTB315S2 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 1235
3VTB315S4-6 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 1265
3VTB315M2A;B 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 1235
3VTB315M4A;B;6A 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 1265
3VTB280M6B 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 1355
3VTB315M2C 508 406 457 216 70 140 20 74,5 315 48 28 135 610 135 205 600 805 1290
3VTB315M4C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 1320
3VTB315M6C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 1320
3VTB315M6D 508 406 457 216 90 170 25 95 315 48 28 135 610 135 205 600 805 1320
3VTB 355 ML (2) 610 560 630 254 80 170 22 85 355 50 28 150 720 250 300 890 935 1580
3VTB 355 ML (4, 6) 610 560 630 254 100 210 28 106 355 50 28 150 720 250 300 890 935 1620
3VTB 355 H (2) 610 900 - 200 70 140 20 74.5 355 45 28 160 730 265 265 1045 995 1800
3VTB 355 H (4, 6) 610 900 - 200 100 210 28 106 355 45 28 160 730 265 265 1045 995 1870

22
General Purpose 3-phase Induction Motors
Dimensions for FOOT MOUNTED MOTORS - IM B3

A-A
AC
F
D

GA

HD
A
HA
H

BA AA K
E C B A
BB AB
L

Motor type A B C D E F GA H HA K AA AB AC BA BB HD L

VTB 200 L8-12 318 305 133 55m6 110 16h9 59 200 32 19 80 400 450 100 380 485 825
VTB 225 S8-12 356 286 149 60m6 140 18h9 64 225 34 19 85 445 505 110 355 535 865
VTB 225 M8-12 356 311 149 60m6 140 18h9 64 225 34 19 85 445 505 110 380 535 890
VTB 250 M8-12 406 349 168 65m6 140 18h9 69 250 36 24 90 495 540 120 420 590 965
VTB 280 S8-12 457 368 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040
VTB 280 M8-12 457 419 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040
VTB 315 S8-12 508 406 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210
VTB 315 M8-12 508 457 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210

Dimensions for FOOT MOUNTED MOTORS - IM B3

AD

A-A
HD

A
D

GA A
H
HA

BA BA AA K
E C B A
BB AB
L

Motor type Poles


A B C D E F GA H HA K AA AB AD BA BB HD L

VTB 355...s 2 610 900 200 70 140 20 74,5 355 45 28 160 730 - 265 1045 995 1800
VTB 355...s 4÷8 610 900 200 100 210 28 106 355 45 28 160 730 - 265 1045 995 1870
VTB 400...s 2 686 1000 224 80 170 22 85 400 50 35 175 840 520 265 1160 1255 1980
VTB 400...s 4÷8 686 1000 224 110 210 28 116 400 50 35 175 840 520 265 1160 1255 1960
VTB 450...s 4÷12 750 1120 254 110 210 28 116 450 60 35 205 940 560 340 1320 1356 2105
VTB 500...s 4÷10 850 1250 280 120 210 32 127 500 70 42 223 1050 560 300 1450 1470 2430

23
General Purpose 3-phase Induction Motors

Dimensions for FLANGE MOUNTED MOTORS - IM B5, IM V1

T LA

HB
A-A A

R=O M
F
D

N
P

GA A S

45
°
E
L 22,5° 45°

Motor type D E F GA M N P LA T HB L S (f) S (holes)

VTB 56-.A 9j6 20 3h9 10,2 100 80j6 120 8 3 98 183 7 4


VTB 56-.B 9j6 20 3h9 10,2 100 80j6 120 8 3 98 193 7 4
VTB 63-.A 11j6 23 4h9 12,5 115 95j6 140 9 3 102 200 10 4
VTB 63-.B 11j6 23 4h9 12,5 115 95j6 140 9 3 102 210 10 4
VTB 71-.A 14j6 30 5h9 16 130 110j6 160 9 3,5 111 223 10 4
VTB 71-.B 14j6 30 5h9 16 130 110j6 160 9 3,5 111 245 10 4
VTB 80-.A 19j6 40 6h9 21,5 165 130j6 200 10 3,5 120 266 12 4
VTB 80-.B 19j6 40 6h9 21,5 165 130j6 200 10 3,5 120 278 12 4
3VTB 80-.A 19j6 40 6h9 21,5 165 130j6 200 10 3,5 119 278 12 4
3VTB 80-.B 19j6 40 6h9 21,5 165 130j6 200 10 3,5 119 306 12 4
3VTB 90S-2,4,6,L2 24j6 50 8h9 27 165 130j6 200 8 3,5 148 331 12 4
3VTB 90L-4,6 24j6 50 8h9 27 165 130j6 200 8 3,5 148 356 12 4
3VTB 100L-2,6 28j6 60 8h9 31 215 180j6 250 11 4 157 377 15 4
3VTB 100L-4A,4B 28j6 60 8h9 31 215 180j6 250 11 4 157 417 15 4
3VTB 112M-2,6 28j6 60 8h9 31 215 180j6 250 12 4 168 398 15 4
3VTB 112M-4 28j6 60 8h9 31 215 180j6 250 12 4 168 425 15 4
3VTB 132S 38k6 80 10h9 41 265 230j6 300 12 4 197 512 15 4
3VTB 132M 38k6 80 10h9 41 265 230j6 300 12 4 197 512 15 4
3VTB 160M 42k6 110 12h9 45 300 250j6 350 13 5 223 643 19 4
3VTB 160L42k6 110 12h9 45 300 250j6 350 13 5 223 643 19 4
3VTB 180M-2,4 48k6 110 14h9 51,5 300 250j6 350 13 5 234 723 19 4
3VTB 180L-4,6 48k6 110 14h9 51,5 300 250j6 350 13 5 234 723 19 4
3VTB 200 55 110 16 59 350 300 400 16,5 5 320 850 19 4
3VTB 225S4 60 140 18 64 400 350 450 18 5 345 930 19 8
3VTB 225M2 55 110 16 59 400 350 450 18 5 345 900 19 8
3VTB 225M4-6 60 140 18 64 400 350 450 18 5 345 930 19 8
3VTB 250M2 60 140 18 64 500 450 550 23 5 385 1010 19 8
3VTB 250M4-6 65 140 18 69 500 450 550 23 5 385 1040 19 8
3VTB 280S2 65 140 18 69 500 450 550 23 5 440 1135 19 8
3VTB 280S4-6 75 140 20 79,5 500 450 550 23 5 440 1135 19 8
3VTB 280M2 65 140 18 69 500 450 550 23 5 440 1135 19 8
3VTB 280M4-6 75 140 20 79,5 500 450 550 23 5 440 1135 19 8
3VTB 315S2* 65 140 18 69 600 550 660 23 6 490 1235 24 8
3VTB 315S4-6* 80 170 22 85 600 550 660 23 6 490 1265 24 8
3VTB 315M2A;B* 65 140 18 69 600 550 660 23 6 490 1235 24 8
3VTB 315M4A;B;6A* 80 170 22 85 600 550 660 23 6 490 1265 24 8
3VTB 315M6B* 80 170 22 85 600 550 660 23 6 490 1355 24 8
3VTB 315M2C* 70 140 20 74,5 600 550 660 23 6 490 1290 24 8
3VTB 315M4C* 80 170 22 85 600 550 660 23 6 490 1320 24 8
3VTB 315M6C* 80 170 22 85 600 550 660 23 6 490 1320 24 8
3VTB 315M6D* 90 170 25 95 600 550 660 23 6 490 1320 24 8
3VTB 355 ML (4 - 6)* 100m6 210 28h9 106 740 680 800 24 6 580 1620 22 8
3VTB 355 H (4 - 6)* 100m6 210 28h9 106 740 680 800 24 6 638 1955 22 8
VTB 355ML8* 100 210 28 106 740 680 800 24 6 580 1620 22 8

* only in vertical position IM V1

24
General Purpose 3-phase Induction Motors

Dimensions for FLANGE MOUNTED MOTORS - IM B5, IM V1


MOTORS series VTB 2p=8

Type of motor D E F GA M N P LA T S HB L

VTB 90S ... 24j6 50 8h9 27 165 130j6 200 8 3,5 12 130 305
VTB 90L ... 24j6 50 8h9 27 165 130j6 200 8 3,5 12 130 330
VTB 100L ... 28j6 60 8h9 31 215 180j6 250 11 4 15 140 376
VTB 112M ... 28j6 60 8h9 31 215 180j6 250 12 4 15 164 384
VTB 132S ... 38k6 80 10h9 41 265 230j6 300 12 4 15 178 463
VTB 132S-2B 38k6 80 10h9 41 265 230j6 300 12 4 15 178 501
VTB 132M ... 38k6 80 10h9 41 265 230j6 300 12 4 15 178 501
VTB 160M ... 42k6 110 12h9 45 300 250j6 350 13 5 19 210 612
VTB 160L ... 42k6 110 12h9 45 300 250j6 350 13 5 19 210 656
VTB 180M ... 48k6 110 14h9 51,5 300 250j6 350 13 5 19 228 705
VTB 180L ... 48k6 110 14h9 51,5 300 250j6 350 13 5 19 228 705

Dimensions for FLANGE MOUNTED MOTORS - IM B5, IM V1

AC
AD

T LA
S

A-A
A M
F
D

N
P

R=O
GA
A

45
°

22,5° 45°
E

Motor type D E F GA AC AD L LA M N P T S
Holes
VTB 200 L8-12 55m6 110 16h9 59 450 340 825 16,5 350 300j6 400 5 18 4
VTB 225 S8-12 60m6 140 18h9 64 505 360 865 18 400 350j6 450 5 18 8
VTB 225 M8-12 60m6 140 18h9 64 505 360 890 18 400 350j6 450 5 18 8
VTB 250 M8-12 65m6 140 18h9 69 540 405 965 19 500 450j6 550 5 18 8
VTB 280 S8-12 75m6 140 20h9 79,5 620 440 1040 20 500 450j6 550 5 18 8
VTB 280 M8-12 75m6 140 20h9 79,5 620 440 1040 20 500 450j6 550 5 18 8
VTB 315 S8-12 80m6 170 22h9 85 620 440 1210 22 600 550j6 660 6 22 8
VTB 315 M8-12 80m6 170 22h9 85 620 440 1210 22 600 550j6 660 6 22 8

25
General Purpose 3-phase Induction Motors

Dimensions for FLANGE MOUNTED MOTORS - IM B5, IM V1


SVh

A-A

F
GA

HB
M
LA

A R=0
T

E
A
S
N
P

Motor type Poles D E F GA HB L LA M N P S T

VTB 355...s* 4÷8 100 210 28 106 640 1955 24 740 680 800 22 6
VTB 400...s* 4÷8 110 210 28 116 725 2016 37 940 880 1000 23 6
VTB 450...s* 4÷12 110 210 28 116 835 2162 30 1080 1000 1150 28 6
VTB 500...s* 4÷12 120 210 32 127 835 2505 30 1080 1000 1150 28 6

* - the SVh motors may operate only in vertical position IM V1.

Dimensions for FOOT/FLANGE MOUNTED MOTORS - IM B35


45°
T LA

S
A-A
A
R=O M
F

HD
4x90°
D

N
P

GA A

HA

H
E C B K AA
BB A
L AB

Motor type A B C D E F GA H K M N P S LA T AA AB BB HA HD L

VTB 56-.A 90 71 36 9j6 20 3h9 10,2 56 8 100 80j6 120 7 8 3 30 110 92 7 154 183
VTB 56-.B 90 71 36 9j6 20 3h9 10,2 56 8 100 80j6 120 7 8 3 30 110 92 7 154 193
VTB 63-.A 100 80 40 11j6 23 4h9 12,5 63 10 115 95j6 140 10 9 3 36 124 106 8,5 165 200
VTB 63-.B 100 80 40 11j6 23 4h9 12,5 63 10 115 95j6 140 10 9 3 36 124 106 8,5 165 210
VTB 71-.A 112 90 45 14j6 30 5h9 16 71 10 130 110j6 160 10 9 3,5 45 142 116 8 182 223
VTB 71-.B 112 90 45 14j6 30 5h9 16 71 10 130 110j6 160 10 9 3,5 45 142 116 8 182 245
VTB 80-.A 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 266
VTB 80-.B 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 278
3VTB 80-.A 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 278
3VTB 80-.B 125 100 50 19j6 40 6h9 21,5 80 10 165 130j6 200 12 10 3,5 55 160 130 9 200 306
3VTB 90S-2,4,6 140 100 56 24j6 50 8h9 27 90 10 165 130j6 200 12 8 3,5 47 182 153 10 238 331
3VTB 90L-2 140 125 56 24j6 50 8h9 27 90 10 165 130j6 200 12 8 3,5 47 182 153 10 238 331
3VTB 90L-4,6 140 125 56 24j6 50 8h9 27 90 10 165 130j6 200 12 8 3,5 47 182 153 10 238 356
3VTB 100L-2,6 160 140 63 28j6 60 8h9 31 100 12 215 180j6 250 15 11 4 52 202 170 12 257 377
3VTB 100L-4A,4B 160 140 63 28j6 60 8h9 31 100 12 215 180j6 250 15 11 4 52 202 170 12 257 417
3VTB 112M-2,6 190 140 70 28j6 60 8h9 31 112 12 215 180j6 250 15 12 4 52 222 170 14 280 398
3VTB 112M-4 190 140 70 28j6 60 8h9 31 112 12 215 180j6 250 15 12 4 52 222 170 14 280 425
3VTB 132S 216 140 89 38k6 80 10h9 41 132 12 265 230j6 300 15 12 4 61 266 220 18 329 512
3VTB 132M 216 178 89 38k6 80 10h9 41 132 12 265 230j6 300 15 12 4 61 266 220 18 329 512
3VTB 160M 254 210 108 42k6 110 12h9 45 160 15 300 250j6 350 19 13 5 81 320 200 25 383 643
3VTB 160L 254 254 108 42k6 110 12h9 45 160 15 300 250j6 350 19 13 5 81 320 300 25 383 643
3VTB 180M 279 241 121 48k6 110 14h9 51,5 180 15 300 250j6 350 19 13 5 92 353 320 27 414 723
3VTB 180L 279 279 121 48k6 110 14h9 51,5 180 15 300 250j6 350 19 13 5 92 353 320 27 414 723

26
General Purpose 3-phase Induction Motors

Dimensions for FOOT/FLANGE MOUNTED MOTORS - IM B35


MOTORS series VTB 2p=8

Motor type A B C D E F GA H HA K AA AB BB HD L LA M N P T S

VTB 90S ... 140 100 56 24j6 50 8h9 27 90 10 10 50 170 153 220 305 8 165 130j6 200 3,5 12
VTB 90L ... 140 125 56 24j6 50 8h9 27 90 10 10 50 170 153 220 330 8 165 130j6 200 3,5 12
VTB 100L ... 160 140 63 28j6 60 8h9 31 100 14 12 45 200 172 240 376 11 215 180j6 250 4 15
VTB 112M ... 190 140 70 28j6 60 8h9 31 112 14 12 54 230 174 276 384 12 215 180j6 250 4 15
VTB 132S ... 216 140 89 38k6 80 10h9 41 132 16 12 56 278 182 310 463 12 265 230j6 300 4 15
VTB 132S-2B 216 140 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501 12 265 230j6 300 4 15
VTB 132M ... 216 178 89 38k6 80 10h9 41 132 16 12 56 278 220 310 501 12 265 230j6 300 4 15
VTB 160M ... 254 210 108 42k6 110 12h9 45 160 20 15 60 305 256 370 612 13 300 250j6 350 5 19
VTB 160L ... 254 254 108 42k6 110 12h9 45 160 20 15 60 305 300 370 656 13 300 250j6 350 5 19
VTB 180M ... 279 241 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705 13 300 250j6 350 5 19
VTB 180L ... 279 279 121 48k6 110 14h9 51,5 180 26 15 70 350 320 408 705 13 300 250j6 350 5 19

Dimensions for FOOT/FLANGE MOUNTED MOTORS - IM B35

T LA

A-A M

HD
A R=0
N
P
D

GA A 45
°

H
45°

HA
22,5°

BA1 BA2 AA K
E C B A
B1 AB
BB
L

Motor type A B B1 C D E F GA H HA K AA AB BA1 BA2 BB HD LA P M N T L S (f) S (holes)

3VTB 200 318 305 - 133 55 110 16 59 200 32 19 80 400 113 113 380 520 16,5 400 350 300 5 850 19 4
3VTB 225S4 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 18 450 400 350 5 930 19 8
3VTB 225M2 356 286 311 149 55 110 16 59 225 34 19 85 440 115 115 380 570 18 450 400 350 5 900 19 8
3VTB 225M4-6 356 286 311 149 60 140 18 64 225 34 19 85 440 115 115 380 570 18 450 400 350 5 930 19 8
3VTB 250M2 406 349 - 168 60 140 18 64 250 37 24 90 480 135 135 445 635 23 550 500 450 5 1010 19 8
3VTB 250M4-6 406 349 - 168 65 140 18 69 250 37 24 90 480 135 135 445 635 23 550 500 450 5 1040 19 8
3VTB 280S2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 280S4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 280M2 457 368 419 190 65 140 18 69 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 280M4-6 457 368 419 190 75 140 20 79,5 280 40 24 105 550 130 165 520 720 23 550 500 450 5 1135 19 8
3VTB 315S2 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1235 24 8
3VTB 315S4-6 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1265 24 8
3VTB 315M2A;B 508 406 457 216 65 140 18 69 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1235 24 8
3VTB 315M4A;B;6A 508 406 457 216 80 170 22 85 315 48 28 120 610 160 160 565 805 23 660 600 550 6 1265 24 8
3VTB 315M6B 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1355 24 8
3VTB 315M2C 508 406 457 216 70 140 20 74,5 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1290 24 8
3VTB 315M4C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1320 24 8
3VTB 315M6C 508 406 457 216 80 170 22 85 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1320 24 8
3VTB 315M6D 508 406 457 216 90 170 25 95 315 48 28 135 610 135 205 600 805 23 660 600 550 6 1320 24 8
3VTB 355 ML (2) 610 560 630 254 80 170 22 85 355 50 28 150 720 250 300 890 935 24 800 740 680 6 1580 22 8
3VTB 355 ML (4,6) 610 560 630 254 100 210 28 106 355 50 28 150 720 250 300 890 935 24 800 740 680 6 1620 22 8
3VTB 355 H (2) 610 900 - 254 70 140 20 74,5 355 45 28 160 730 265 265 1045 995 24 800 740 680 6 1854 22 8
3VTB 355 H (4,6) 610 900 - 254 100 210 28 106 355 45 28 160 730 265 265 1045 995 24 800 740 680 6 1924 22 8
VTB 355 ML8 610 560 630 254 100 210 28 106 355 50 28 150 720 250 300 890 935 24 800 740 680 6 1620 22 8

27
General Purpose 3-phase Induction Motors
Dimensions for FOOT/FLANGE MOUNTED MOTORS - IM B35

A-A

F
D
AC
GA

T LA
S

M
A

HD
N
P

R=O 45
°

HA
H
A 22,5° 45°

BA AA K
E C B A
BB AB
L

Motor type A B C D E F GA H HA K AA AB AC BA BB HD L LA M N P T S
Holes
VTB 200 L8-12 318 305 133 55m6 110 16h9 59 200 32 19 80 400 450 100 380 485 825 16,5 350 300 400 5 18 4
VTB 225 S8-12 356 286 149 60m6 140 18h9 64 225 34 19 85 445 505 110 355 535 865 18 400 350 450 5 18 8
VTB 225 M8-12 356 311 149 60m6 140 18h9 64 225 34 19 85 445 505 110 380 535 890 18 400 350 450 5 18 8
VTB 250 M8-12 406 349 168 65m6 140 18h9 69 250 36 24 90 495 540 120 420 590 965 19 500 450 550 5 18 8
VTB 280 S8-12 457 368 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040 20 500 450 550 5 18 8
VTB 280 M8-12 457 419 190 75m6 140 20h9 79,5 280 40 24 100 560 620 165 520 660 1040 20 500 450 550 5 18 8
VTB 315 S8-12 508 406 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210 22 600 550 660 6 22 8
VTB 315 M8-12 508 457 216 80m6 170 22h9 85 315 46 28 105 610 620 190 560 695 1210 22 600 550 660 6 22 8

A-A AD
D

T LA GA

HD
S

A R=0
M
N
P

A
H
HA

BA BA AA K
E C B A
BB AB
L

Type of Poles
motor A B C D E F GA H HA K AA AB AD BA BB HD L LA M N P S T
VTB 355...s 2 610 900 254 70 140 20 74.5 355 45 28 160 730 344 265 1045 995 1854 24 740 680 800 22 6
VTB 355...s 4÷8 610 900 254 100 210 28 106 355 45 28 160 730 344 265 1045 995 1924 24 740 680 800 22 6
VTB 400...s 2 686 1000 280 80 170 22 85 400 50 35 175 840 520 265 1160 1255 2031 30 940 880 1000 25 6
VTB 400...s 4÷8 686 1000 280 110 210 28 116 400 50 35 175 840 520 265 1160 1255 2016 30 940 880 1000 25 6
VTB 450...s 4÷12 750 1120 315 110 210 28 116 450 60 35 205 940 560 340 1320 1356 2162 30 1080 1000 1150 28 6
VTB 500...s 4÷10 850 1250 355 120 210 32 127 500 70 42 223 1050 560 300 1450 1470 2505 30 1080 1000 1150 286

28
General Purpose 3-phase Induction Motors
Dimensions for FLANGE MOUNTED MOTORS - IM B14

45°

T LE

HB
A
A-A

4x90°
R=O
F

M
N
P
D

GA
A

E
S
L

Motor type Flange D E F GA M N P S T LE HB L

VTB 56- .A1 B14/C1 9j6 20 3h9 10,2 85 70j6 105 M6 2,5 15 98 183
VTB 56- .A2 B14/C2 9j6 20 3h9 10,2 65 50j6 80 M5 2,5 12,5 98 183
VTB 56- .B1 B14/C1 9j6 20 3h9 10,2 85 70j6 105 M6 2,5 15 98 193
VTB 56- .B2 B14/C2 9j6 20 3h9 10,2 65 50j6 80 M5 2,5 12,5 98 193
VTB 63- .A1 B14/C1 11j6 23 4h9 12,5 100 80j6 120 M6 3 14 102 200
VTB 63- .A2 B14/C2 11j6 23 4h9 12,5 75 60j6 90 M5 2,5 9,5 102 200
VTB 63- .B1 B14/C1 11j6 23 4h9 12,5 100 80j6 120 M6 3 14 102 210
VTB 63- .B2 B14/C2 11j6 23 4h9 12,5 75 60j6 90 M5 2,5 9,5 102 210
VTB 71- .A1 B14/C1 14j6 30 5h9 16 115 95j6 140 M8 3 14 111 223
VTB 71- .A2 B14/C2 14j6 30 5h9 16 85 70j6 105 M6 2,5 12 111 223
VTB 71- .B1 B14/C1 14j6 30 5h9 16 115 95j6 140 M8 3 14 111 245
VTB 71- .B2 B14/C2 14j6 30 5h9 16 85 70j6 105 M6 2,5 12 111 245
VTB 80- .A1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 120 266
VTB 80- .A2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 120 266
VTB 80- .B1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 120 278
VTB 80- .B2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 120 278
3VTB 80- .A1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 119 278
3VTB 80- .A2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 119 306
3VTB 80- .B1 B14/C1 19j6 40 6h9 21,5 130 110j6 160 M8 3,5 14 119 278
3VTB 80- .B2 B14/C2 19j6 40 6h9 21,5 100 80j6 120 M6 3 12 119 306
3VTB 90S 2,4,6,L2 B14/C1 24j6 50 8h9 27 130 110j6 160 M8 3,5 10 148 331
3VTB 90S 2,4,6,L2 B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 148 331
3VTB 90L 4,6 B14/C1 24j6 50 8h9 27 130 110j6 160 M8 3,5 10 148 356
3VTB 90L 4,6 B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 148 356
3VTB 100L2,6 B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 157 377
3VTB 100L2,6 B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 157 377
3VTB 100L4A,4B B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 157 417
3VTB 100L4A,4B B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 157 417
3VTB 112M2,6 B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 168 398
3VTB 112M2,6 B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 168 398
3VTB 112M4 B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 168 425
3VTB 112M4 B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 168 425
3VTB 132S B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 197 512
3VTB 132S B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 197 512
3VTB 132M B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 197 512
3VTB 132M B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 197 512

29
General Purpose 3-phase Induction Motors

Dimensions for FLANGE MOUNTED MOTORS - IM B14


MOTORS series VTB 2p=8

45°

T LE

HB
A
A-A

4x90°
R=O
F

M
N
P
D

GA
A

E
S
L

Motor type Flange D E F GA M N P S T LE HB L

VTB 90S ... B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 130 305
VTB 90L ... B14/C1 24j6 50 8h9 27 130 110j6 160 M8 3,5 10 130 330
VTB 90L ... B14/C2 24j6 50 8h9 27 115 95j6 140 M8 3 10 130 330
VTB 100L ... B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 140 376
VTB 100L ... B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 140 376
VTB 112M ... B14/C1 28j6 60 8h9 31 165 130j6 200 M10 3,5 12 164 384
VTB 112M ... B14/C2 28j6 60 8h9 31 130 110j6 160 M8 3,5 12 164 384
VTB 132S ... B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 178 463
VTB 132S ... B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 178 463
VTB 132S-2B B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 178 501
VTB 132S-2B B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 178 501
VTB 132M ... B14/C1 38k6 80 10h9 41 215 180j6 250 M12 4 12 178 501
VTB 132M ... B14/C2 38k6 80 10h9 41 165 130j6 200 M10 3,5 12 178 501
VTB 160M ... B14/C1 42k6 110 12h9 45 265 230j6 300 M12 4 13 210 612
VTB 160M... B14/C2 42k6 110 12h9 45 215 180j6 250 M12 4 20 210 612
VTB 160L ... B14/C1 42k6 110 12h9 45 265 230j6 300 M12 4 13 210 656
VTB 160L ... B14/C2 42k6 110 12h9 45 215 180j6 250 M12 4 20 210 656

30
General Purpose 3-phase Induction Motors

List of Motor parts Frame Size: 56-80


Motor series 3VTB and VTB

3
7
4

6 8
22

5 9

21

12 10

14 11
23 Item Description
20 15 1 terminal box cover
2 rubber gasket
3 terminal board
4 terminal box
19 5 rubber gasket
6 gland
16 13 7 terminal box complete
8 fan cover
9 fan
15 10 tie rod
11 NDE shield
12 stator
13 foot
18 17 14 spring washer
15 bearing
16 rotor
17 DE shield
18 shaft seal
19 key
20 flange B5
21 flange B14/C1
22 flange B14/C2
23 name plate

DE - drive end
NDE - non drive end

31
General Purpose 3-phase Induction Motors

Frame Size: 90÷180 List of Motor parts


Motor series 3VTB and VTB (2p = 8 ÷ 12)

15
17
25
18
20 19

16
7
24 14
13
22 12
11
3
23 10
21
5

Item Description
1 DE shield
2 2 rotor
6 8 3 shaft seal
5 4 shaft seal cover
9 5 bearing
1 6 key
3 7 name plate
4 81 sx foot
91 dx foot
10 NDE shield
11 fan
12 seeger ring
13 fan cover
14 rubber gasket
15 terminal box cover
16 terminal board
17 rubber gasket
18 terminal box
19 glands
20 terminal box complete
21 spring washer
22 stator
232 flange B14/C2
242 flange B14/C1
25 flange B5

1- for frame size 132 - 180 feet can


DE - drive end be screwed or integrated with
NDE - non drive end the motor housing,
2 - only for frame size 90 - 132.

32
General Purpose 3-phase Induction Motors

List of Motor parts Frame Size: 200÷355


Motor series 3VTB

13
12
15 11
10
25 14 24b 21b

24a 16
4b 9
17
18
26

3b

8b
22b
7a 19
4a 7b 23b
20
24a
6

2
Item Description
5 1 DE shield
2 rotor
3a,b shaft seal
22a 23a 4a,b bearing
5 key
6 housing with feet
1
7a,b internal bearing cap
3a 8a 8a,b external bearing cap
9 NDE shield
10 fan
21a
11 seeger ring
12 fan cover
13 terminal box cover
14 terminal board
15 rubber gasket
16 terminal box housing
17 rubber gasket
18 cable glands
19 fan cover support
20 spring washer
21a,b seeger ring
22a,b grease shield
23a,b bearing internal ring
24a,b grease nipple
25 flange B5
26 rubber gasket

DE - drive end
NDE - non drive end

33
General Purpose 3-phase Induction Motors

Frame Size: 200÷315 List of Motor parts


Motor series VTB (2p = 8 ÷ 12)

12
11
10
22
26
13
9

6
7
2 3
5
7 8b
25
23
1
4 24
23
8a 20
22 14
16
19
25 17
18
Item Description
27 15 1 DE shield
2 rotor
3 shaft seal
4 DE bearing
5 key
6 housing with feet
3 24 7 internal bearing cap
8a,b external bearing cap
21 9 NDE shield
10 fan
11 seeger ring
12 fan cover
13 NDE bearing
14 terminal box cover
15 terminal cover support
16 rubber gasket
17 terminal box housing
18 rubber gasket
19 cable glands
20 fan cover support
21 spring washer
22 seeger ring
23 grease shield *
24 bearing internal ring *
25 DE grease nipple
26 NDE grease nipple
27 flange B5

* only for size 315


DE - drive end
NDE - non drive end

34
General Purpose 3-phase Induction Motors

PRODUCT RANGE
Three-phase motors with from 0,04kW up to 1400kW general purpose, pumps,
INDUCTION MOTORS
GENERAL PURPOSE

squirrel-cage rotor fans, compressors,


series VTB. specific requirements relating
High efficiency motors to the highest efficiency
series 2VTB, 3VTB and 4VTB
3-PHASE

(Efficiency classes
IE1, IE2, IE3, IE4)

Single-phase motors with from 0,04kW up to 4kW general purpose,


INDUCTION MOTORS
GENERAL PURPOSE

squirrel-cage rotor pumps,


series VMB, VMC. fans, compressors,
- motors with standard wood machines,
starting torque machines and devices
1-PHASE

- motors with increased for food processing,


starting torque
- motors with high
mixers for building
starting torque.

Three-phase squirrel-cage from 160kW up to 3150kW general industrial use,


INDUCTION MOTORS

high voltage and high efficiency drives used for own needs
motors series VTB with cast-iron of power plants
HIGH VOLTAGE

housing. (pumps, fans, coal mills,


High voltage motors with conveyors)
module construction
(steel/welded housing)
series VTB-E and VTBw.

Three-phase and single-phase from 0,04kW up to 160kW applied in case of necessity


brake motors with to stop the motor suddenly
BRAKE MOTORS

AC and DC brakes.

Three-phase 3-phase from 0,06kW up to 250kW drives adapted for speed


FOREIGN COOLING

induction motors regulation by frequency converter


with foreign cooling.
MOTORS WITH

Increased safety motors. from 0,06kW up to 22kW adapted for operation in


EXPLOSION-PROOF

areas endangered
by explosion (without methane)

Flame-proof motors. from 0,75kW up to 315kW application in an atmosphere


MOTORS

where a mixture of
explosive gas
and vapours may occur

Low voltage NEMA motors from 1HP up to 250HP general industrial application,
SIE series (in compliance with pumps, fans
NEMA MOTORS

the NEMA PREMIUM


requirements).

Traction motors from 50kW up to 1500kW various traction vehicles:


TRACTION MOTORS

and traction generators. trams (including low-deck trams),


trolleybusses,
subway and locomotives

35
VEMAT MOTORI S.r.l. - Registered office: Via Pantano, 2 - 20122 Milano - Italy
Productive unit and administrative offices: Via Gualda, 10 Z.I. - 36075 Montecchio Maggiore (VI) - Italy
Tel. +39 0444 491973 r.a. - Fax +39 0444 491978 - e-mail: [email protected] - www.vemat.it

You might also like