0% found this document useful (0 votes)
28 views

Par-33maa User Guide

The document is a user guide for the PAR-33MAA Remote Controller, detailing its controls, display features, and main menu functions. It includes instructions for setting timers, adjusting temperature ranges, and managing energy-saving modes. Additionally, it provides contact information for Mitsubishi Electric support and notes on product specifications and limitations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views

Par-33maa User Guide

The document is a user guide for the PAR-33MAA Remote Controller, detailing its controls, display features, and main menu functions. It includes instructions for setting timers, adjusting temperature ranges, and managing energy-saving modes. Additionally, it provides contact information for Mitsubishi Electric support and notes on product specifications and limitations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

User Guide

Controls PAR-33MAA
Remote Controller

PAR-33MAA Remote Controller

Menu

Previous Screen

Select

Function Buttons

Power ON/OFF

Controller Display

7 12 13 14 15 16 17 18 1. Mode 12. Buttons locked


2. Setpoint 13. On/off timer enabled
3
3. Clock 14. Weekly timer enabled
6 19
4. Fan speed
8 15. Energy saving mode
9 20 5. Function
10 16. Outdoor in silent mode
6. On/off prohibited
17. Thermistor reading
1 4 7. Mode prohibited
18. Vane settings
8. Setpoint prohibited
9. Filter reset prohibited 19. Louver settings
10. Filter sign 20. Ventilation settings
11 21 2
5 11. Room temperature 21. Setpoint limit

Main Display

The Function Buttons are used to change the


relevant display options
Press F1 to cycle through the modes:
Cooling / Dry / Fan / Auto / Heating

Press F2 to decrease temperature

Press F3 to increase temperature

Press F4 to alternate through fan speeds


F1 F2 F3 F4
User Guide

Controls PAR-33MAA
Remote Controller

Main Menu

Page To view the main menu in order to set schedules,


number
functions and maintenance, press the Menu button
Use the function buttons F1 and F2 to move cursor up and down,
F3 and F4 to change the page

Once you have moved the cursor next to the


option you want, press the Select button

To return to previous screen at any time,


press the Previous Screen button
F1 F2 F3 F4

Main Menu List


Setting and Display Items Setting Details
Vane / Louver / Vent Use to set the vane angle - Select a desired vane setting from five different settings.
(Lossnay) Use to turn On/Off the louver - Select a desired setting from "On" and "Off."
Use to set the amount of ventilation - Select a desired setting from "Off," "Low," and "High."

Timer On/Off timer Use to set the operation On/Off times - Time can be set in 5-minute increments. *Clock setting is required

Auto-Off timer Use to set the Auto-Off time - Time can be set to a value from 30 to 240 in 10-minute increments.

Weekly timer Use to set the weekly operation On/Off times - Up to eight operation patterns can be set for each day.
*Clock setting is required. *Not valid when the On/Off timer is enabled.

Restriction Temp. range Use to restrict the preset temperature range - Different temperature ranges can be set for different operation modes.

Operation lock Use to lock selected functions - The locked functions cannot be operated.

Energy saving* Auto return Use to get the units to operate at the preset temperature after performing energy-save operation for a specified time period -
Time can be set to a value from 30 and 120 in 10-minute increments. * This function will not be valid when the preset temperature ranges are restricted.

Schedule Set the start/stop times to operate the units in the energy-save mode for each day of the week, and set the
energy-saving rate - Up to four energy-save operation patterns can be set for each day. Time can be set in 5-minute increments.
Energy-saving rate can be set to a value from 0% and 50 to 90% in 10% increments. *Clock setting is required.

Night setback Use to make Night setback settings - Select "Yes" to enable the setting, and "No" to disable the setting.
The temperature range and the start/stop times can be set. *Clock setting is required.

Filter information Use to check the filter status - The filter sign can be reset.

Error information Use to check error information when an error occurs - Error code, error source, refrigerant address,
unit model, manufacturing number, contact information (dealer's phone number) can be displayed.
*The unit model, manufacturing number, and contact information need to be registered in advance to be displayed.

Maintenance Manual vane angle Use to set the vane angle for each vane to a fixed position.

Initial setting Clock Use to set the current time.

Main display Use to switch between "Full" and "Basic" modes for the Main display - The default setting is "Full."

Contrast Use to adjust screen contrast.

Language selection Use to select the desired language.

*Function not supported by all models. ‘Not available / Unsupported function’ will appear on display if user selects a function not supported by corresponding indoor unit model.

Telephone: 01707 282880


email: [email protected] web: www.airconditioning.mitsubishielectric.co.uk
UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or
to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any
contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

You might also like