NOA 120 PSF_unlocked

The Miami-Dade County Product Control Section has issued a Notice of Acceptance (NOA) for Cornell Iron Works, Inc.'s Insulated Steel Rolling Door, which is approved for use in Miami-Dade County and other jurisdictions. The product complies with the Florida Building Code and has a missile impact rating for both large and small missiles, with an expiration date of July 9, 2025. The NOA can be revoked if the product fails to meet building code requirements or if there are changes in its materials or manufacturing.

Uploaded by

Cesar Toncolo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views9 pages

NOA 120 PSF_unlocked

The Miami-Dade County Product Control Section has issued a Notice of Acceptance (NOA) for Cornell Iron Works, Inc.'s Insulated Steel Rolling Door, which is approved for use in Miami-Dade County and other jurisdictions. The product complies with the Florida Building Code and has a missile impact rating for both large and small missiles, with an expiration date of July 9, 2025. The NOA can be revoked if the product fails to meet building code requirements or if there are changes in its materials or manufacturing.

Uploaded by

Cesar Toncolo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

MIAMI-DADE COUNTY

PRODUCT CONTROL SECTION


11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Cornell Iron Works, Inc.
24 Elmwood Avenue
Mountaintop, PA 18707
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In
Miami-Dade County) and/ or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product o r
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use o f
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code, including
the High Velocity Hurricane Zone.
DESCRIPTION: Insulated Steel Rolling Door up to 14ft-5in Wide (80 FPS Impact)
APPROVAL DOCUMENT: Drawing No. ES-16-57-CIW, titled “14’-5” Wide 120 PSF 80 FPS Insulated
Rolling Steel Door”, sheets 1 through 6 of 6, dated 01/06/2015, with revision B dated 01/23/2020, prepared
by The Cookson Company, signed and sealed by Shawn Patrick Kelley, P.E. on 03/18/2020, bearing the
Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration
date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer’s name or logo, one of the 2 manufacturing
addresses on drawings, model number, the positive and negative design pressure rating, indicate impact rated
if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test
standards, and the statement reading ‘Miami-Dade County Product Control Approved’ is to be located on the
door’s side track, bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, fo r
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 20-046.19 and consists of this page 1 and evidence pages E-1 and E-2, as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.

NOA-No. 20-0925.09
Expiration Date: July 9, 2025
Approval Date: December 10, 2020
Page 1
Cornell Iron Works, Inc.

NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED

1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s

A. DRAWINGS “Submitted under NOA # 15-0318.08”


1. Drawing No. ES-16-57-CIW, titled “14’-5” Wide 120 PSF 80 FPS Insulated Rolling Steel
Door”, sheets 1 through 6 of 6, dated 01/06/2015, with revision A dated 05/19/2015, prepared
by The Cookson Company, signed and sealed by Joseph H. Dixon, Jr., P.E.

B. TESTS “Submitted under NOA # 15-0318.05”


1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94 (Level ‘E’)
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
4) Forced Entry Test, per FBC, TAS 202-94
5) Tensile Test per ASTM E8-08,
along with marked-up drawings and installation diagram of Thermiser Roll-up Garage Doors,
prepared by Intertek/Architectural Testing, Inc., Test Report No. D1278.02-109-18 , dated
01/29/2014, signed and sealed by Michael D. Stremmel, P.E.
2. Test report on Salt Spray Performance Test per ASTM B117-09 of G90 unpainted and G40
painted samples, prepared by Intertek, Test Report No. G100075502MID-002, dated
05/26/2010, signed and sealed by Rick Curkeet, P.E.
3. Test Report on Ignition Temperature per ASTM D1929 and Flame Spread/ Smoke Density per
ASTM E84 of polyurethane foam, prepared by ETC Laboratories, Repot # ETC-07-1071-
18738.0, dated 03/26/2007, signed and sealed by Joseph L. Doldan, P.E.

C. CALCULATIONS “Submitted under NOA # 15-0318.05”


1. Calculations prepared by Joseph H. Dixon, Jr., P.E., dated 02/02/2015, signed and sealed by
Joseph H. Dixon, Jr., P.E.

D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER)

E. MATERIAL CERTIFICATIONS
1. None.

F. STATEMENTS “Submitted under NOA # 15-0318.08”


1. Private label agreement dated 02/20/2015.
“Submitted under NOA # 15-0318.05”
2. Statement letter of code conformance to 2010 and 5 th edition (2014) FBC issued by Joseph H.
Dixon, Jr., P.E., dated 03/11/2015, signed and sealed by Joseph H. Dixon, Jr., P.E.
3. Statement letter of no financial interest issued by Joseph H. Dixon, Jr., P.E., dated 03/11/2015,
signed and sealed by Joseph H. Dixon, Jr., P.E.

Carlos M. Utrera, P.E.


Product Control Examiner
NOA-No. 20-0925.09
Expiration Date: July 9, 2025
Approval Date: December 10, 2020
E-1
Cornell Iron Works, Inc.

NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED

2. EVIDENCE SUBMITTED UNDER PREVIOUS NOA # 20-0416.19

A. DRAWINGS
1. Drawing No. ES-16-57-CIW, titled “14’-5” Wide 120 PSF 80 FPS Insulated Rolling Steel Door”,
sheets 1 through 6 of 6, dated 01/06/2015, with revision B dated 01/23/2020, prepared by The Cook so n
Company, signed and sealed by Shawn Patrick Kelley, P.E. on 03/18/2020.

B. TESTS
1. None.

C. CALCULATIONS “Submitted under NOA # 18-0125.04”


1. Calculations prepared by Moment Engineering+ Design, LLC, dated 01/12/2018, signed and sealed by
Shawn Patrick Kelley, P.E.

D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER).

E. MATERIAL CERTIFICATIONS
1. None.

F. STATEMENTS
1. Statement letter of code conformance to FBC 6 th Edition (2017) and of no financial interest, d a t ed M arch
21, 2020, issued by Moment Engineering+ Design, LLC, signed and sealed by Shawn Patrick Kelley,
P.E.
2. Private label agreement dated 02/27/2020.

3. NEW EVIDENCE SUBMITTED


A. DRAWINGS
1. None.

B. TESTS
1. None.

C. CALCULATIONS
1. None.

D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER).

E. MATERIAL CERTIFICATIONS
1. None.

F. STATEMENTS
1. Statement letter of code conformance to FBC 7 th Edition (2020) and of no financial interest, dated Au gu st
12, 2020, issued by Moment Engineering + Design, LLC, signed and sealed by Shawn Patrick Kelley,
P.E.

Carlos M. Utrera, P.E.


Product Control Examiner
NOA-No. 20-0925.09
Expiration Date: July 9, 2025
Approval Date: December 10, 2020
E-2
PRODUCT REVISED
as complying with the Florida
Building Code
NOA–No. 20–0925.09
Expiration Date 07/09/2025

By
Miami–Dade Product Control
PRODUCT REVISED
as complying with the Florida
Building Code
NOA–No. 20–0925.09
Expiration Date 07/09/2025

By
Miami–Dade Product Control
PRODUCT REVISED
as complying with the Florida
Building Code
NOA–No. 20–0925.09
Expiration Date 07/09/2025

By
Miami–Dade Product Control
PRODUCT REVISED
as complying with the Florida
Building Code
NOA–No. 20–0925.09
Expiration Date 07/09/2025

By
Miami–Dade Product Control
PRODUCT REVISED
as complying with the Florida
Building Code
NOA–No. 20–0925.09
Expiration Date 07/09/2025

By
Miami–Dade Product Control
PRODUCT REVISED
as complying with the Florida
Building Code
NOA–No. 20–0925.09
Expiration Date 07/09/2025

By
Miami–Dade Product Control

You might also like