PVsyst - Simulation report
Grid-Connected System
Project: exam
Variant: New simulation variant
No 3D scene defined, no shadings
System power: 130 kWp
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: exam
Variant: New simulation variant
PVsyst V7.4.3
VC0, Simulation date:
03/11/23 14:52
PVsyst TRIAL
with v7.4.3
Project summary
Geographical Site Situation Project settings
Cairo Latitude 30.08 °N Albedo 0.20
Egypt Longitude 31.28 °E
Altitude 0m
Time zone UTC+2
Meteo data
Al Imām ash Shāfi‘ī
Meteonorm 8.1 (1996-2015) - Synthetic
System summary
PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 306 units Nb. of units 1 unit
Pnom total 130 kWp Pnom total 110 kWac
Pnom ratio 1.182
Results summary
Produced Energy 222243 kWh/year Specific production 1709 kWh/kWp/year Perf. Ratio PR 83.67 %
PVsyst TRIAL
Project and results summary
Main results
Loss diagram
Predef. graphs
Table of contents
PVsyst TRIAL
PVsyst TRIAL
03/11/23 PVsyst Evaluation mode Page 2/7
Project: exam
Variant: New simulation variant
PVsyst V7.4.3
VC0, Simulation date:
03/11/23 14:52
PVsyst TRIAL
with v7.4.3
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model LR5-54HPH-425M Model SG110-CX
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 425 Wp Unit Nom. Power 110 kWac
Number of PV modules 306 units Number of inverters 9 * MPPT 11% 1 unit
Nominal (STC) 130 kWp Total power 110 kWac
Modules 18 string x 17 In series Operating voltage 200-850 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.18
Pmpp 119 kWp No power sharing between MPPTs
U mpp 491 V
I mpp 242 A
PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 130 kWp Total power 110 kWac
Total 306 modules Number of inverters 1 unit
Module area 598 m² Pnom ratio 1.18
Cell area 550 m²
Array losses
Array Soiling Losses Thermal Loss factor DC wiring losses
Loss Fraction 3.0 % Module temperature according to irradiance Global array res. 22 mΩ
Uc (const) 20.0 W/m²K Loss Fraction 1.0 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
IAM loss factor
Incidence effect (IAM): User defined profile
AC wiring losses
Inv. output line up to injection point
Inverter voltage 400 Vac tri
Loss Fraction 1.78 % at STC
Inverter: SG110-CX
Wire section (1 Inv.) Copper 1 x 3 x 95 mm²
Wires length 113 m
PVsyst TRIAL
03/11/23 PVsyst Evaluation mode Page 3/7
Project: exam
Variant: New simulation variant
PVsyst V7.4.3
VC0, Simulation date:
03/11/23 14:52
PVsyst TRIAL
with v7.4.3
Main results
System Production
Produced Energy 222243 kWh/year Specific production 1709 kWh/kWp/year
Perf. Ratio PR 83.67 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
February 107.3 57.28 15.69 133.6 127.8 15604 15185 0.874
March 158.3 74.44 18.76 180.9 172.9 20586 20021 0.851
April 184.0 84.24 21.77 189.5 180.7 21233 20656 0.838
May 211.0 93.42 25.97 199.1 189.3 21945 21338 0.824
June 218.1 86.63 28.27 196.8 186.7 21463 20864 0.815
July 218.1 85.07 29.71 200.1 189.8 21697 21093 0.811
August 200.3 85.59 29.81 198.5 188.9 21517 20935 0.811
September 169.8 65.30 27.63 188.4 179.7 20428 19871 0.811
October 135.0 63.08 24.63 165.3 158.0 18498 18000 0.837
November 97.7 45.29 19.83 133.3 127.6 15281 14863 0.858
December 86.5 40.80 15.93 124.7 119.5 14622 14220 0.877
Year 1881.3 829.15 22.71 2042.5 1947.5 228491 222243 0.837
PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst TRIAL
03/11/23 PVsyst Evaluation mode Page 4/7
Project: exam
Variant: New simulation variant
PVsyst V7.4.3
VC0, Simulation date:
03/11/23 14:52
PVsyst TRIAL
with v7.4.3
Loss diagram
1881 kWh/m² Global horizontal irradiation
+8.6% Global incident in coll. plane
PVsyst TRIAL
253401 kWh Array nominal energy (at STC effic.)
+0.84% PV loss due to irradiance level
-1.00%
Inverter Loss over nominal inv. voltage
Inverter Loss due to power threshold
Inverter Loss due to voltage threshold
Available Energy at Inverter Output
AC ohmic loss
222243 kWh Energy injected into grid
PVsyst TRIAL
PVsyst TRIAL
03/11/23 PVsyst Evaluation mode Page 5/7
Project: exam
Variant: New simulation variant
PVsyst V7.4.3
VC0, Simulation date:
03/11/23 14:52
PVsyst TRIAL
with v7.4.3
Predef. graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
03/11/23 PVsyst Evaluation mode Page 6/7
PVsyst V7.4.3
VC0, Simulation date:
03/11/23 14:52
PVsyst TRIAL
with v7.4.3
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL