This document is a test certificate issued by Durai & Sons for lifting machines and tackles, specifically for M/S. Sri Vaari Crane Service. The certificate confirms the satisfactory condition and load capacity of a steel wire rope with a safe working load of 10 tons, following thorough examination and testing on June 14, 2024. The next test is due by June 13, 2025.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
2 views
wr2-svcs
This document is a test certificate issued by Durai & Sons for lifting machines and tackles, specifically for M/S. Sri Vaari Crane Service. The certificate confirms the satisfactory condition and load capacity of a steel wire rope with a safe working load of 10 tons, following thorough examination and testing on June 14, 2024. The next test is due by June 13, 2025.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
DURAI&SONS
An ISO 9001:2015 Certified Inspection &Certification Company
Competent Person under Director of Industrial Safety & Health Approval No: H1/2438/2022 Phone: +91 94455 14453/94455 Email: [email protected] No: 145-A.Vinayakar KoilStreet, Nandiambakkam, Chennai-600 120 Test Certificate for Lifting Machines and Liting Tackles Prescribed under Rule 55(a) as per the section29 of Factories Act 1950
T.C: D&S/ SRI VAARI/2024/WR-01 TEST CERTIFICATE Date: 14-JUN-2024
1 Name &Address of the Company: M/S. SRI VAARICRANE SERVICE New No: 5/1.Thirumagal Rice Mill K.K. Kottai Road, Trichy-620 010 2 Distinctive number or make if any and description sufficlent to STEEL WIRE ROPE Identty the Load LIiftdng Wire Rope of the lIfdng Capacity: 10.0Tons tackle Type: Single Legged and both ends Aluminum grumbled Size:30mm dia and 8.0mtr long Id. No: 8221 & 8222 Quantity:02nos 3 Date, when lifting machine, rope or tackle was used in factory 2023 4 Date and No. of certificate relating to any test and examination made under sub-Rule of Rule 60 together wth the name of First Time Inspection person who issue the certtficate 5 Date of each perlodlcal through examination made under clause (a) () or sub-sectlon (1)osectlon 29 of the Act and sub-rule 7 14-JUN-2024 and by whom It was carrled out. 6 Date of anneallng or other best treatment of the chain and other No lifting tackde made under sub rule 6&by whom t was carried out 7 Particularsof any defects found at any such time of thorough examinatkon or after annealing and affecting the safe working No load &the steps taken to remedy such defects. Safe working Load (SWL) as marked on the name plate of theunit 10.0Tons Condtlon of over running devices such as Griping and Looping Check & Found OK splicing etc. 10 Load Test with proof load of 10.0Tons Load Tested Found Satlsfactory 11 Visual Inspectlon of Wre Rope General Condition, Aluminum Grambling and load holding performance check &found Satisfactory 12 Remarks NI 13 Next Test due on or before 13-JUN-2025 /we certifty that on: 14-JUN-2024. I/we have thoroughly examined the abovementioned Wire Rope and that the above is a correct report of the resut. Certifier & SO S.DURA DISH No: H1/2438/2022 OMPETEN PERSO TE