0% found this document useful (0 votes)
11 views7 pages

Mock-up-Wind Loads-2016

This document outlines the wind load calculations for a low-rise building according to ASCE 7-2016 standards. It includes parameters such as building dimensions, basic wind speed, exposure category, and various coefficients used in the calculations. The final design wind pressure is calculated to be 1.08 kN/m² for the main wind force resisting system.

Uploaded by

Mohsin Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views7 pages

Mock-up-Wind Loads-2016

This document outlines the wind load calculations for a low-rise building according to ASCE 7-2016 standards. It includes parameters such as building dimensions, basic wind speed, exposure category, and various coefficients used in the calculations. The final design wind pressure is calculated to be 1.08 kN/m² for the main wind force resisting system.

Uploaded by

Mohsin Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Date 20-Jan-25

Wind Loads Dsn. By s


Anchor
Chk. By sa
As per ASCE 7-2016 Rev. No. 0

Mean Height (h) = 7.20 m Low Rise Building Sec. 6.20 ASCE 7-16
(Eave height may be used if θ<=10°) Sec. 6.5.6.2.2 ASCE 7-16
Roof Slope = 0.00 :10 0.00 Degrees

Length of the building (L) = 12.80 m Horizontal dimension measured parallel to the wind

Width of the building (B) = 2.40 m Horizontal dimension measured normal to the wind

Basic Wind Speed (V) = 169.2 km/hr Ultimate wind speed at 10 mSec. 6.20 ASCE 7-16

Building Category = II Table 6-1 ASCE 7-16

Exposure Category = C Sec. 6.5.6 ASCE 7-16

Structure Type = Main Wind Force Resisting System Table 6-4 ASCE 7-16

2
Ao = 0.00 m Sec. 6.20 ASCE 7-16

2
Ao = Total area of opening in a wall that receives positive external pressure (m )

2
Aoi = 0.00 m Sec. 6.20 ASCE 7-16
Aoi should be set to 0 for open buildings
Aoi = The sum of the areas of opening in the building envelope (Walls & Roof) not including A o (m2)

2
Ag = 0.00 m Sec. 6.20 ASCE 7-16

Ag = The gross area of that wall in which Ao is identified (m 2)

2
Agi = 0.00 m Sec. 6.20 ASCE 7-16
Agi should be set to 0 for open buildings
2
Agi = The sum of the gross surface areas of the building envelope (Walls & Roof) not including Ag (m )

Open Building

Velocity Pressure Exp. Coeff. (K z) = 0.93 For Main Wind Force - Table 6-3 ASCE 7-16
- Resisting system (MWFRS)
Velocity Pressure Exp. Coeff. (K z) = 0.93 For Comp. and Claddings Table 6-3 ASCE 7-16

Topographic Factor (Kzt) = 1.00 Figure 6-4 ASCE 7-16

Directionality Factor (Kd) = 0.85 Table 6-4 ASCE 7-16

Basic Wind Speed (Vs) = 47.00 m/sec V / 3.6

Importance Factor ( I ) = 1.00 Table 6-1 ASCE 7-16

qz = qh = 0.613 x 10-3 Kz Kzt Kd Vs2 I kN/m2 Eqn. 6-15 ASCE 7-16


Enter 'q' value if provided
qz = q h = 0.00 qz = q h = 1.08 kN/m 2 For Main Wind Force Resisting system (MWFRS)

qz = q h = 1.08 kN/m 2 For Components and Claddings

Gust effect factor (G) = 0.85 For Rigid Structures Sec. 6.5.8

Design Wind Pressure (p) = qh [ (Gcpf) - (Gcpi) ] kN/m2 Eqn. 6-18 ASCE 7-16
S 7.2 M
h 7.2 M
B 12.8 M
Lr 2.4 M

S/h 1
B/S 1.77777778
B/S 0.33333333
Lr/S 0.33333333

Cf 1.42

Reduction Factor of Return Corner 0.9

Reduction Factor for Temporary structure 0.8

Note:- The Values are [( GCp + Gcpi )] = q = 1.08 0.85 1.42 0.9 0.8 1.099172119
2
kN/m