removal of external q400
removal of external q400
A. Reference Information
REFERENCE DESIGNATION
TASK 10−11−00−869−801 Static Grounding of the Aircraft
TASK 24−00−00−910−801 Electrical/Electronic Safety Precautions
3. Job Set−Up
Subtask 12−00−06−869−001
Subtask 12−00−06−910−002
B. Obey all the electrical and electronic safety precautions (Refer to TASK 24−00−00−910−801 ).
4. Procedure
Subtask 12−00−06−861−002
WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO MAINTENANCE ON OR NEAR
ELECTRICAL/ELECTRONIC EQUIPMENT. IF YOU DO NOT DO THIS, YOU CAN CAUSE
INJURIES TO PERSONS AND DAMAGE TO THE EQUIPMENT.
A. Remove the external DC electrical power from the aircraft as follows:
(1) Set EXT PWR switch on the DC CONTROL panel (1) to the OFF position.
(2) Set the BATTERY MASTER , MAIN, AUX and STBY switches to the OFF position.
PSM 1−84−2
EFFECTIVITY:
Page 305
See first effectivity on page 305 of 12−00−06 12−00−06 Sep 05/2021
5. Close Out
Subtask 12−00−06−865−006
A. If the AC Contactor Box are in the removed condition, do the procedure that follows:
(1) Remove the tags and close the circuit breakers that follow:
Subtask 12−00−06−410−002
REFERENCE DESIGNATION
113BL Ground Power Receptacle Door
PSM 1−84−2
EFFECTIVITY:
Page 306
See first effectivity on page 305 of 12−00−06 12−00−06 Sep 05/2021
Subtask 12−00−06−941−002
C. Remove all tools, equipment, and unwanted materials from the work area.
PSM 1−84−2
EFFECTIVITY:
Page 307
See first effectivity on page 305 of 12−00−06 12−00−06 Sep 05/2021
A
LEGEND
1. DC Control panel.
2. DC Bus voltage readout (typical).
B 3. DC Ground power receptacle.
DC CONTROL
− −−
PFCS
SPOILERS
LO RUD RI RO
br474a01.dg, sw/gw, may13/2010
LI
L ELEV R ELEV
FWD
PSM 1−84−2
EFFECTIVITY:
Page 308
See first effectivity on page 305 of 12−00−06