The PME family of circuit breaker analyzers offers portable, accurate solutions for evaluating medium and high voltage circuit breakers. These analyzers can record the transition of circuit breaker poles with high resolution and include features for testing synchronization and control mechanisms. The product line includes three models, each with unique capabilities and options for upgrades, ensuring flexibility to meet various technical needs and budgets.

Uploaded by

Erick Brisanet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
14 views3 pages

Pme X00 TX en

The PME family of circuit breaker analyzers offers portable, accurate solutions for evaluating medium and high voltage circuit breakers. These analyzers can record the transition of circuit breaker poles with high resolution and include features for testing synchronization and control mechanisms. The product line includes three models, each with unique capabilities and options for upgrades, ensuring flexibility to meet various technical needs and budgets.

Uploaded by

Erick Brisanet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
CIRCUIT BREAKER ANALYZERS 2 CIRCUIT BREAKER ANALYSIS The PME family of circuit breaker analyzers combine portability, ease of operation and remarkable accuracy for the task of evaluating the condition and performance of medium and high voltage three phase circuit breakers of any kind. These small, lightweight yet sturdy instru- ments will record the transition of the circuit breaker's poles between OPEN and CLOSE posi- tions with a reso- lution of 0.1 milli- seconds to reveal graphically and nu- merically any unba- lance or misallign ment in the three phases. Another two auxiliary inputs allow the recording of the activity by other moving contacts during the same analysis to provide ad- ditional information about the syncronization of important ele- ments in or outside the circuit breaker itself. (SUX Besar i es The recording process can be triggered by the user or by the change of status of a voltage or dry contact signal. The duration of OPEN and CLOSE commads can be set to accurately match that of the circuit breaker’s control device, in order to test the machi- ne’s driving mechanism against requirements. A comprehensive range of options will let you choose the combination that best accommodates your technical needs as well as your budget. Upgradeable The three models composing the PME family of cir- cuit breaker analyzers include alll the essential ele- ments, a complete set of connections, accessories and a few distinctive characteristics, and all of them feature the PME BUS - our contribution to protect your investment with the possibility to upgrade your device's functionality at any time with existing and future plug & play options. PME-SOD-T Leas RECHARGEABLE BATTERY v z RESISTANCE MEASUREMENT J 1 (ON BOARD TOUCH DISPLAY J PRINTER d WHF LAN, USB J 1 HE BUS J J J ‘TRANSDUCER INPUT OPTION v v PME-SOO-TR: THE REFERENCE Designed by experts in switchgear commissioning and maintenance, this best seller set a new standard in portability and efficiency that continues to rule the market nowadays. With onboard touch control, full battery su- pport, contact resistance measurement, results storage & printing and ready for travel transducers, you won't need anything else. s PME-700-TR: NO COMPROMISE Featuring the latest in user interface trends, you can drive it from your personal portable device via WiFi or wired Ethernet. No need of data transfer: your results will be ready for reporting at any time. PME-G00-T: FAST & EASY Link your personal device wirelessly, con- nect the circuit breaker, lauch the test and collect your data. This easy. And in budget. OPTIONAL ACCESSORIES PME-TCE TRANSDUCER INTERFACE Allows the connection of up 103 digital and 4 analog position transducers to the PME BUS. Plug & play ‘operation, PME-ATK TRAVEL ANALYSIS ENTRY KIT A One rotary transducer, one srtcutted mt magnet ok and 9 fll tet adaptor for dese om alometer ain transport bag wth rm to place your PHE-TCE msi PME-ATA ROTARY ANALYSIS SET One retry tansauoet frcuttea ret magnet ok and cam Glametor adapta PME-LT5OA LINEAR TRANSDUCER Wed and teste for near = displacement analysis. CBL-11-PMEXXX LONG CONNECTIONS om ‘meter for are, outdoor AV rent breakers Man , A niact Cat con ; fnitary an contact PP sec avatabi navuaty PMIERESC cls recommended PME-RESC HIGH PRESSURE CLIPS High pressure crocodle ‘ips with stronger weigh Suprt for ger onnedtions Combine timing andcontoct festersoup EuroSMC, S. A. Calle Buril, 69 (Poligono Industrial P-29) 28400 Collado Villalba. Madrid, SPAIN T.: +34 849 8980 F.: +3491 8512553 [email protected] www.smeint.com TECHNICAL CHARACTERISTICS MAIN CONTACT CONNECTIONS Number: 3 Open circuit voltage: 410Vde Test current: 100 mA max. ‘Status theesholds (CLOSED: R <200 PREANSTERTION: 30 0 < R < 1040 OPEN: R> 100. BINARY INPUT Connections: Dry contact mode 2 fully Isolated Open circuit voltage: 8 Vdc Test current: 20 mA max Voltage detection mode Allowed voltage range: 21.5 = $375 Vpk (285 Vcclea) Lower threshold: 21.5 V Upper threshold: 215 V TEST CONTROL Programmable sequences: 0, C, 0.£,€-0, 0-00, C0 Recording length: 2 seconds Coll pulse duration (0 oF C: Pause interval duration: Deterred recording delay: (0+ 2000 miliseconds (0+ 2000 miliseconds (0+ 18 seconds Recording start options Coll command / Binary signal / Main contact status change / Programmable delay ‘TEST RESULTS Graphics zoom 4100, 200, 400, 800 ot 2000 ms: ‘Time resolution: (04 mitisecona Time accuracy 0.05% of reading + 0.4 ms Coll current measurement: Coll current graphics: Contact resistance* (0+ #5000 Apk. Accuracy: 1% + 125 mA ‘ms sampling Range: 10010 + 4.0 Resolution: 01 uO min Accuracy: 0.1% of reading # 4 digit Test current: 10 Ace max. USER INTERFACE Onboard panel ‘Muititanguage, touch sensitive backlighted LoD Printer* Thermal, standard 140 mm (4.3 roll width External Application program on a connected device Networking* Ethernet(t x RJds) + WIFI (access point or infraestructure) Comm ports USB (A & B)*, RS-232", PME BUS, STANDARD PACKAGE "Muitipin S-meter test connections (coll control, main contacts, binary and contact resistance*) and complete set of 4mm crocodile clips. Overvoltage suppression diodes (2-pack) Set of spare fuses 2x thermal paper rolls* Power cord Lightweight bag for instrument, cables and accessories RS-232*, Ehemet, and USB communications cables Test and reporting software Printed users manual and visual gulde to connections in English GENERAL Standards: 1EC-61010, EMC-50081-2, EN-500822 Power supply 90-264 Vea. 6060 Hz Rechargeable batten*: Intemal, 12Vde NEMA Instrument size: ‘340 x 300 x 150 mm (43.3 x44.8 x59 inch) Instrument weight PME-SOO-TR: 8 lg (47.6 Ib) / PME-SOOT: 5.6 kg (12.3 Ib) / PME-7OO-TR: 7 eg (25.4 ke) ‘Temperature: Working: 0 + 65°. Storage: -40 + 70°C Relative humidity (*)im speciic models 95% max (non-condensing) DISTRIBUTED B' 2 i i : g 5 i document maybe chan Please note: duct the continuous research and develooment bv EreSMG,socfcations in tl