0% found this document useful (0 votes)
28 views

Web LCT Guide on RuralLink Key Configurations V1.3

The document is a Web LCT Guide for configuring the RTN 320F in the RuralLink microwave fronthaul solution, detailing various configuration procedures and commands. It includes sections on clock tracing, service management, and bandwidth notifications, among others. The guide is intended for internal use by Huawei Technologies and spans a total of 35 pages.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views

Web LCT Guide on RuralLink Key Configurations V1.3

The document is a Web LCT Guide for configuring the RTN 320F in the RuralLink microwave fronthaul solution, detailing various configuration procedures and commands. It includes sections on clock tracing, service management, and bandwidth notifications, among others. The guide is intended for internal use by Huawei Technologies and spans a total of 35 pages.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 35

Product Name Security Level

OptiX RTN series INTERNAL


Product Version
Total 35 pages
V100R022C10

Web LCT Guide on RuralLink Key


Configurations

Prepared By Jiang Qinyue Date 2022-11-26


Proofread By Zhang Fei, Zhao Jiming, Chen Yong Date 2022-11-28
Reviewed By Xiong Fulin Date 2022-11-28
Approved By Liu Yawen Date 2022-11-28

Huawei Technologies Co., Ltd.


All Rights Reserved
Web LCT Guide on RuralLink Key Configurations INTERNAL

Change History

Date Issue Description Author


2022-11-28 0.1 Completed the draft. Jiang Qinyue
2022-11-28 1.0 Revised the document based on review comments. Jiang Qinyue
2023-01-17 1.1 Added the configuration for low-latency mode. Chen Yong
2023-01-19 1.2 Added the description that bandwidth notification must Dai Jingyu
be configured for microwave.
2023-07-20 1.3 Added the configuration for cascade CA, XPIC, and Chen Yong
EPLA.

2025-03-06 Huawei confidential. No spreading without permission. Page 2 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

Contents

1 Usage Note.......................................................................................................................6
2 Configuring Clock Tracing: Upstream NE (Device on the BBU Side).........................6
3 Configuring Clock Tracing: Downstream NE (Device on the RRU Side)....................7
4 Configuring Time Tracing...............................................................................................8
4.1 Enabling a PTP Port........................................................................................................................ 8
4.2 Enabling 1588 Overheads............................................................................................................... 9

5 Configuring Clock Source Priority...............................................................................10


6 Configuring a PTP Clock Subnet No...........................................................................10
7 Deleting an E-Line or E-LAN Service...........................................................................11
7.1 Querying All E-Line Services......................................................................................................... 11
7.2 Querying All E-LAN Services......................................................................................................... 11
7.3 Deleting an E-Line or E-LAN Service............................................................................................12

8 Changing the Speed of a Service Port to 2.5 Gbps....................................................13


8.1 Deleting the QoS Policy for a Port................................................................................................. 13
8.2 Deleting a 10GE Port..................................................................................................................... 14
8.3 Adding a 2.5GE Port...................................................................................................................... 15

9 Configuring a Passthrough E-Line and Bandwidth Notification...............................16


9.1 Configuring a Passthrough E-Line................................................................................................. 16
9.2 Configuring OAM and Bandwidth Notification................................................................................17
9.2.1 Creating an MD..................................................................................................................... 17
9.2.2 Creating an MA..................................................................................................................... 18
9.2.3 Creating an MEP.................................................................................................................. 19
9.2.4 Configuring a Remote MEP.................................................................................................. 21
9.2.5 Enabling Bandwidth Notification........................................................................................... 23

10 Configuring the Low-Latency Mode..........................................................................24


11 RTN320F: Cascade CA with Intra-Board XPIC and Cascade EPLA........................25
11.1 Networking Example.................................................................................................................... 25
11.2 Enabling the IF Port 2.................................................................................................................. 25
11.3 Configuring the COMBO Port to Work as the CA Cascade Port..................................................26
11.4 Deleting the QoS Policy of the Two IF Ports................................................................................26
11.5 Configuring the RF Port Mode on the Master NE........................................................................26
11.6 Configuring the Multiplexing Mode of the IF Port on the Master NE............................................27
11.7 Configuring Intra-Board XPIC...................................................................................................... 28
11.8 Configuring Cascade CA on the Master NE.................................................................................29

2025-03-06 Huawei confidential. No spreading without permission. Page 3 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11.8.1 Configuring the First CA Cascade Group............................................................................29


11.8.2 Configuring the Second CA Cascade Group.......................................................................31
11.9 Configuring Cascade EPLA on the Maste NE..............................................................................33
11.10 Configuring Cascade EPLA on the Slave NE.............................................................................33

12 Saving the Configuration of the NE...........................................................................34

2025-03-06 Huawei confidential. No spreading without permission. Page 4 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

Web LCT Guide on RuralLink Key Configurations


Keyword: RTN 320F, Web LCT, microwave, BBU, RRU
Abstract: This document uses the RTN 320F as an example to describe the key configuration
items for RuralLink — a microwave fronthaul solution for wireless networks — on the Web LCT.
For details about the basic configuration of microwave links, see the configuration guide of
microwave devices available at http://support.huawei.com.
Terms, Acronyms, and Abbreviations

Acronyms and Abbreviations Full Spelling


RTN Radio transmission node
BBU Baseband processing unit
RRU Remote radio unit

2025-03-06 Huawei confidential. No spreading without permission. Page 5 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

1 Usage Note
This document describes the RTN 320F configurations. The RTN 900 configurations are basically
the same as these for the RTN 320F.
In this document, the IF port 1-DMC5-1 and data port 1-DMC5-5 on the RTN 320F connecting to
the BBU are used as example.

2 Configuring Clock Tracing: Upstream NE (Device on the BBU


Side)
CLI-based configuration:
cfg-set-synclass-ex:1,2,0x01ff0005&0x00f10001
This command configures the clock source priority table, with the first parameter indicating the
slot ID, the second parameter indicating the number of clock sources, and the third parameter
indicating the optional clock source. For the third parameter, the value part 0x00f10001 indicates
the free running mode, and 0x01 of the value part 0x01ff0005 indicates the slot ID (hexadecimal)
and ff0005 of the value part 0x01ff0005 indicates the port ID.

Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 6 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

3 Configuring Clock Tracing: Downstream NE (Device on the


RRU Side)
CLI-based configuration:
cfg-set-synclass-ex:1,3,0x01ff0001&0x01ff0002&0x00f10001
This command configures the clock source priority table, with the first parameter indicating the
slot ID, the second parameter indicating the number of clock sources, and the third parameter
indicating the optional clock source. For the third parameter, the value part 0x00f10001 indicates
the free running mode, and 0x01 of the value part 0x01ff0002 indicates the slot ID (hexadecimal)
and ff0002 of the value part 0x01ff0002 indicates the port ID.
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 7 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

4 Configuring Time Tracing


4.1 Enabling a PTP Port
CLI-based configuration:
cfg-set-ptpenable:1,255,1,enable
cfg-set-ptpenable:1,255,2,enable
cfg-set-ptpenable:1,255,5,enable
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 8 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

4.2 Enabling 1588 Overheads


CLI-based configuration:
radio-cfg-set-1588oh-en:1,255,1,enable
radio-cfg-set-1588oh-en:1,255,2,enable
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 9 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

5 Configuring Clock Source Priority


For the PTP Clock Priority 1 parameter, the value is 140 by default on the wireless network
device (as an upstream device). As a downstream device, the RTN must be configured with a
priority lower than that of the upstream device. A larger value indicates a lower priority and the
range for 1588V2 is 0 to 255. Therefore, this parameter must be set to a value from 141 to 255
(150 in this example). If the value on the wireless network device is changed, this parameter must
be reconfigured.
CLI-based configuration:
cfg-set-ptptimeattr:0xffff,0xff,0xffff,187,254,INTERNAL_OSCILLATOR,150,128
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 10 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

6 Configuring a PTP Clock Subnet No.


The wireless network requires this parameter to be set to 24. If the value on the wireless network
device is changed, this parameter must be reconfigured.
CLI-based configuration:
cfg-set-ptpdomain:24
Web LCT-based configuration:

7 Deleting an E-Line or E-LAN Service


7.1 Querying All E-Line Services
CLI-based configuration:
ethn-cfg-get-vuni:e-line,0,0
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 11 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

7.2 Querying All E-LAN Services


CLI-based configuration:
ethn-cfg-get-vuni:e-lan,0,0
Web LCT-based configuration:

7.3 Deleting an E-Line or E-LAN Service


CLI-based configuration:
ethn-cfg-del-ethserv: ESRV-INDEX
Specify ESRV-INDEX based on the query result above.
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 12 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

8 Changing the Speed of a Service Port to 2.5 Gbps


The port rate of the microwave equipment is determined according to the requirements of a COE.
Currently, the COE needs a port rate of 2.5 Gbps.

8.1 Deleting the QoS Policy for a Port


CLI-based configuration:
ethn-cfg-set-portpolicy:1,255,5,4294967295
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 13 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

8.2 Deleting a 10GE Port


CLI-based configuration:
cfg-del-subbd-port:1,255,5
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 14 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

8.3 Adding a 2.5GE Port


CLI-based configuration:
cfg-add-subbd-port:1,255,5,sdh-opport,ptn-2p5ge
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 15 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

9 Configuring a Passthrough E-Line and Bandwidth


Notification
9.1 Configuring a Passthrough E-Line
CLI-based configuration:
set port1 1,255,1
set port2 1,255,5
set i 3
:trans-begin:unlock
:ethn-cfg-crt-ethserv:$i,$i,"linewxc",disable,e-line
:ethn-cfg-add-vuni:$i,1,root,$port1,0,0
:ethn-cfg-add-vuni:$i,2,root,$port2,0,0
:trans-commit:"create eline"
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 16 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

9.2 Configuring OAM and Bandwidth Notification


9.2.1 Creating an MD
CLI-based configuration:
ethn-cfg-create-ethsrvoam-md:3,"wxc-md",7
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 17 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

9.2.2 Creating an MA
CLI-based configuration:
ethn-cfg-create-ethsrvoam-ma:3,3,"wxc-ma",3
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 18 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

9.2.3 Creating an MEP


MD and MA must be the same, while the MEP ID must be different for the BBU and RRU sides.
In this example, the MEP ID is 3 for the BBU side and 4 for the RRU side.
Configuration of the microwave equipment on the BBU side:
CLI-based configuration:
ethn-cfg-create-ethsrvoam-mep:3,3,3,egress,3,vuni,1,0xffff
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 19 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

Configuration of the microwave equipment on the RRU side:


CLI-based configuration:
ethn-cfg-create-ethsrvoam-mep:3,3,4,egress,3,vuni,1,0xffff
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 20 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

9.2.4 Configuring a Remote MEP


Configuration of the microwave equipment on the BBU side:
CLI-based configuration:
ethn-cfg-add-ethsrvoam-marmep:2,1,1,4
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 21 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

Configuration of the microwave equipment on the RRU side:

2025-03-06 Huawei confidential. No spreading without permission. Page 22 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

CLI-based configuration:
ethn-cfg-add-ethsrvoam-marmep:2,1,1,3
Web LCT-based configuration:

9.2.5 Enabling Bandwidth Notification


CLI-based configuration (Periodic notification by default)
ethn-cfg-set-ethsrvoam-bnstat:3,3,3,enable,7
If non-periodic bandwidth notification was used, change it to periodic notification.
ethn-cfg-set-ethsrvoam-bnpara:3,3,3,period,1,0
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 23 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

10 Configuring the Low-Latency Mode


The low-latency mode can be enabled only when the IF port uses IS8 mode and the channel
bandwidth is 28, 40, 56, 112, or 224 MHz. In addition, the high and low sites must use consistent
low-latency mode configuration.
CLI-based configuration:
radio-cfg-get-link-delay-low:1,255,1
radio-cfg-set-link-delay-low:1,255,1,enable
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 24 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11 RTN 320F: Cascade CA with Intra-Board XPIC and Cascade


EPLA
11.1 Networking Example
Prerequisites:
 The cascade cables are connected correctly in accordance with the following networking
diagram, and the antennas over the air interface have been commissioned successfully.
 Web LCT V100R022C10SPC100 or later is ready.
 NE 1 and NE 2 are configured as the master NE, and NE 3 and NE 4 are configured as the
slave NE. Ports 5 and 7 are inserted with 10GE optical modules.

11.2 Enabling the IF Port 2


IF port 2 on the RTN 320F is disabled by default.

2025-03-06 Huawei confidential. No spreading without permission. Page 25 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11.3 Configuring the COMBO Port to Work as the CA Cascade Port

11.4 Deleting the QoS Policy of the Two IF Ports


This step is necessary for configuring the cascade EPLA protection group.
The example shows the steps for deleting the QoS policy of IF port 1. For IF port 2, perform
similar steps.

11.5 Configuring the RF Port Mode on the Master NE


Perform this step only on the master NE, and retain the default configuration on the slave NE.
1. Right-click on the NE panel and choose RF Model Switch from the shortcut menu.

2025-03-06 Huawei confidential. No spreading without permission. Page 26 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

2. Set the model attribute to MODU (the default value is ODU).

11.6 Configuring the Multiplexing Mode of the IF Port on the Master


NE
Perform this step only on the master NE.
Set Conflux Mode to Share ODU for the IF port by referring to the following example.

2025-03-06 Huawei confidential. No spreading without permission. Page 27 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11.7 Configuring Intra-Board XPIC


Configuring intra-board XPIC on the four NEs, with the parameters configured according to
network planning.
The following example shows how to add a new XPIC protection group. In this step, ensure that
the horizontal or vertical polarization directions are consistent on the four NEs.

If the following figure is shown, the configuration is successful.

2025-03-06 Huawei confidential. No spreading without permission. Page 28 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11.8 Configuring Cascade CA on the Master NE


Configure cascade CA only on the master NE, because the slave NE synchronizes the
configurations automatically over the CA cascade cable.
Configure two CA cascade groups.

11.8.1 Configuring the First CA Cascade Group


1. Click New.
2. Set CA Type to Cascaded.
3. Choose 1-DMD4-1(IF1) for both the local and adjacent NEs.
4. Set CA ID to 1.

2025-03-06 Huawei confidential. No spreading without permission. Page 29 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

5. Click Next Step and configure these parameters based on network planning.

2025-03-06 Huawei confidential. No spreading without permission. Page 30 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11.8.2 Configuring the Second CA Cascade Group


1. Click New.
2. Set CA Type to Cascaded.
3. Choose 1-DMD4-IF2 for both local and adjacent NEs.
4. Set CA ID to 2.

5. Click Next Step and configure these parameters based on network planning.

2025-03-06 Huawei confidential. No spreading without permission. Page 31 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

If the following figure is shown, the configuration is successful.

2025-03-06 Huawei confidential. No spreading without permission. Page 32 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11.9 Configuring Cascade EPLA on the Master NE


Click New and configure the parameters in strict accordance with the following figure.
Parameter planning:
 Set NE role to Master NE.
 Set Main Port to 1(IF1).
 The Selected Service Ports area shows the service port, which is port 6 in this example.
 The Selected Local Members area shows the cascade port, which is port 5 in this example.
 The Selected Slave Ports area shows the slave port, which 1-DMD4-2(IF2) in this example.

If the following figure is shown (after cascade EPLA is also configured on the slave NE), the
configuration is successful.
The cascade EPLA status of the slave NE must also be queried on the master NE.
Port Status and Link Status must be Normal. Otherwise, the cascade EPLA is not correctly
configured.

2025-03-06 Huawei confidential. No spreading without permission. Page 33 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

11.10 Configuring Cascade EPLA on the Slave NE


Click New and configure the parameters in strict accordance with the following figure.
Parameter planning:
 Set NE role to Slave NE.
 Set Main Port to 1(IF1).
 The Selected Service Ports area shows the service port, which is port 6 in this example.
 The Selected Local Members area shows the cascade port, which is port 5 in this example.
 The Selected Slave Ports area shows the slave port, which 1-DMD4-2(IF2) in this example.

If the following figure is shown, the configuration is successful.


The cascade EPLA status can be queried only on the master NE.

12 Saving the Configuration of the NE


CLI-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 34 of 35


Web LCT Guide on RuralLink Key Configurations INTERNAL

dbms-copy-all:drdb,fdb
Web LCT-based configuration:

2025-03-06 Huawei confidential. No spreading without permission. Page 35 of 35