0% found this document useful (0 votes)
6 views

3.DESIGN OF STEEL PURLINS

The document outlines the design calculations for steel purlins in a truss system, including parameters such as load, span, and material properties. Key calculations include wind load, vertical load, and the use of C-Purlins with specific dimensions and spacing. The design is deemed safe based on the interaction diagram and stress checks against material yield strengths.

Uploaded by

Amer Gonzales
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views

3.DESIGN OF STEEL PURLINS

The document outlines the design calculations for steel purlins in a truss system, including parameters such as load, span, and material properties. Key calculations include wind load, vertical load, and the use of C-Purlins with specific dimensions and spacing. The design is deemed safe based on the interaction diagram and stress checks against material yield strengths.

Uploaded by

Amer Gonzales
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DESIGN OF STEEL PURLINS

DATA:

bay of Truss = 3 m. on center


(provide sagrods at midspan)
Fy = 276 Mpa
fy = 230 Mpa
distance of purlins = 0.60 m. on center
height of kingpost = 0.80 m.
span of rafter = 8.02 m
wt. of roofing = 80 Pa
wind pressure = 1440 Pa of vertical surface
Assume weight of purlins = 10.8 kg/m
= 105.95 N/m

DESIGN CALCULATION

pitch = 0.099751
angle of inclination = 11.3 º
2
wt. of purlins = 176.58 N/m
Wind Load:
Pn= 2Psin θ = 542.6873 Kpa
1+sin 2 θ
Total vertical Load = 1697 Pa
Vertical Load(P) = 1018 N/m
Wind Load = 326 N/m
Wn = 1324 N/m
Wt = 199.16 N/m
Mn = 1489 N-m
Mt = 56.0 N-m

Try C-Purlins 2" x 3" @ 0.60m.o.c.

Sx= 13109 mm3


3
Sy= 7689 mm

f = Mn + Mt
Sx 1/2 Sy

Mn/Sx= 113.61
Mt/0.5Sy= 14.57

f= 128.18 Mpa OK
Fb=0.60fy
Fb= 138 Mpa

Using Interaction Diagram:

fbx + fby = 1.0 ; 0.624 + 0.070 = 0.694


0.66Fy 0.75Fy
SAFE
fbx=Mx/Sx ; fby=My/0.5Sy

fbx= 113.6
fby= 14.57